• Title/Summary/Keyword: 배기 계산

Search Result 169, Processing Time 0.021 seconds

An Analysis of the Loss of Residual Heat Removal System Event for Pressurized Water Reactor at Reduced Inventory Operation (가압경수로의 저수위 운전시 잔열제거계통 상실사고에 대한 분석)

  • Han, Kee-Soo;Song, Jin-Ho
    • Nuclear Engineering and Technology
    • /
    • v.27 no.5
    • /
    • pp.645-660
    • /
    • 1995
  • The loss of Residual Heat Removal System (RHRS) event during reduced inventory operation for the Korean Standard Nuclear Power Plants (KSNPPS) is simulated by RELAP5/MOD3 and RELAP5/MOD3.1 Tn cases are considered : Base case for an intact Reactor Coolant System (RCS) with no tent and a vent case for an open system. Comparative simulations of base case are peformed by RELAP5/MOD3 and RELAP5/MOD3. 1 computer codes. The results of too simulations are generally in good qualitative and quantitative agreement. However, since the results of RELAP5/MOD3 simulation reveals the deficiency of RELAP5/MOD3 wall heat model, the RELAP5/AOD3.1 computer code is used for the simulation of the vent case. The analysis result of base case show that two steam generators are insufficient to remove decay heat at one day after shutdown, where the RCS is closed. The RCS pressure increased continuously and reached the RCS temporary boundaries design pressure of 0.24 MPa around 4,000 seconds. In the vent case with a flow capacity equivalent to three times the capacity of Pressurizer Safety Valve (PSV), it is shown that the RCS Pressure does not reach 0.24 MPa and core uncovery does not occur until 10,000 seconds. The detailed discussions on the results of this study suggest the feasibility of RELAP5/AOD3.1 as an analysis tool for the simulation of the loss of RHRS event at reduced inventory operation. The results of this study also provide insight for the determination of proper vent capacity.

  • PDF

수소 배기용 저온 흡착(Cryo-Sorption) 펌프의 열설계

  • 조용섭;최병호
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.45-45
    • /
    • 1999
  • 한국원자력연구소에서 개발중인 KSTAR 중성입자입사 (NBI) 가열장치의 이온원을 시험하기 위한 진공 챔버 (높이 1.2m, 폭 1.2m, 길이 2.4m)의 수소 배기는 저온 흡착 펌프를 제작하여 이용할 계획이다. 흡착제는 활성탄으로 하고, 흡착제의 냉각은 20K 12W Cold Head를 이용한다. 이 흡착제가 부착된 무산소동판을 액체 질소로 냉각된 Chevron Baffle로 열차폐한다. 이 흡착제가 수소를 배기하기 위해서는 15K 이하로 냉각이 되어야 하므로, 이에 대한 열설계가 중요하다. 흡착판에 가해지는 열부하를 평가하고, 이 열부하에서 흡착판 온도가 15K 이하가 되도록 열설계를 수행하였다. 열부하 중 가장 큰 것은 Ghevron을 통해 들어오는 복사열로, Chevron의 복사율 및 난반사도에 따라 MOnte Calro 법 전산코드를 작성하여 복사열을 계산하였다. 크기 500mm x 400mm인 흡착판에 대한 시험 결과를 바탕으로 열설계에 대한 타당성 검증 및 크기 800mm x 1400mm인 흡착판에 대해 열설계 내용에 대해 발표한다.

  • PDF

수소 배기용 저온 흡착 (Cryo-Sorption) 펌프의 열설계

  • 조용섭;최병호
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.127-127
    • /
    • 1999
  • 한국원자력연구소에서 개발중인 KSTAR 중성입자입사(NBI) 가열장치의 이온원을 시험하기 위한 진공챔버(높이 1.2m, 폭 1.2m, 길이 2.4m)의 수소 배기는 저온 흡착펌프를 제작하여 이용할 계획이다. 흡착제는 활성탄으로 하고, 흡착제의 냉각은 20K 12W Cold Head를 이용한다. 이 흡착제가 부착된 무산소동판을 액체 질소로 냉각된 Chevron Baffle로 열차폐한다. 이 흡착제가 수소를 배기하기 위해서는 15K 이하로 냉각이 되어야 하므로, 이에 대한 열설계가 중요하다. 흡착판에 가해지는 열부하를 평가하고, 이 열부하에서 흡착판 온도가 15K 이하가 되도록 열설계를 수행하였다. 열부하 중 가장 큰 것은 Chevron을 통해 들어오는 복사열로 Chevron의 복사율 및 난반사도에 따라 Monter Carlo법 전산 코드를 작성하여 복사열을 계산하였다. 크기 500mmx400mm인 흡착판에 대한 시험 결과를 바탕으로 열설계에 대한 타당성 검증 및 크기 800mmx1400mm인 흡착판에 대해 열설계 내용에 대해 발표한다.

  • PDF

A Numerical Simulation of Smoke Control in Daegu Subway Stations II. Air Flowrate of Extraction System (대구 지하철역 제연의 문제점과 대책 II. 배기방식 제연설비의 풍량)

    • Fire Science and Engineering
    • /
    • v.17 no.4
    • /
    • pp.105-110
    • /
    • 2003
  • In Part II, the temperature and smoke particle distributions of the extraction system, which yielded the best smoke removal performance among the three smoke control systems in Part I, for extraction flowrates of 0.6∼2.4 ㎥/s and two fire sizes of 200 ㎾ and 2 ㎿ were presented. The same numerical method was utilized to the same computational domain and configurations as Part I. It was shown that the extraction flowrate affects the smoke control performance significantly, and that a similar trend in improving the smoke removal performance with the increasing extraction flowrate between the two fire sizes. An extraction flowrate of 2.4 ㎥/s or higher was required for the temperature in the escape route less than $^{\circ}C$ for the given situations.

Fundamental design consideration for optimum performance in altitude test cell facility (고공시험설비의 전체 사양을 결정하는 시험부를 중심으로 설비개발시의 주요 고려사항)

  • Choi, Kyoung-Ho;Lee, Jung-Hyung;Owino, George;Lee, Dae-Soo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.411-415
    • /
    • 2008
  • This paper presents on design factor considered in an altitude test cell facility to determine the best sizing to optimize exhaust diffuser pressure recovery and the exact cooling load required to be supplied under transient operation. Engine simulation was performed to analyse the exhaust gas temperature, exit mass flow rate, specific fuel consumption and exhaust velocity helpful in determining secondary mass air flow and the mixed air temperature entering the ejector. based on this, the amount of cooling load was deduced. It was found that improved pressure recovery reduces operational cost(air supply facility, cooling water).

  • PDF

Preliminary Experimental Study for Water Recovery and Particulate Matter Reduction through a Hybrid System that Combines Exhaust Cooling and Absorption from Ships (선박배출 배기냉각과 흡수식이 결합된 하이브리드 시스템을 통한 물 회수 및 미세먼지 저감을 위한 기초실험연구)

  • Youngmin Kim;Donggil Shin;Younghyun Ryu
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.7
    • /
    • pp.1252-1258
    • /
    • 2022
  • The exhaust gas from the marine engines include a quantity of water vapor and particulate matter. The total particulate matter includes filterable particulate matter (FPM) and condensable particulate matter (CPM) that condense after releasing into the atmosphere. The portion of CPM is higher than that of FPM that is removable through the filter before discharging. An experimental setup for waste heat and water recovery and removal of CPM in the exhaust gas was tested using an industrial gas boiler in the laboratory. The water and CPM in the exhaust gas were removed through the first stage of cooling method and further removed through the second stage of absorption method. The efficiencies of water recovery were 73% after the first stage of cooling method and 90% after the second stage of absorption method. At the same time, the CPM was removed by 80-90% through the processes. The waste heat recovered could be used to process heat, and the water recovered could be used to process water in the ship. Furthermore, the CPM, which is a major source of the particulate matter but not subject to administrative regulation, could be removed effectively.

Pressure Measurement in a Cavity for Flat panel Display (평판디스플레이용 패널의 진공도 측정)

  • 조영래;문제도;오재열;정효수
    • Journal of the Korean Vacuum Society
    • /
    • v.4 no.3
    • /
    • pp.247-252
    • /
    • 1995
  • 진공측정용 센서의 크기보다 더 작은 미세소자 내부의 진공도를 계산에 의해 간접적으로 구하는 방법을 제시하였다. 평판디스플레이용 진공판넬의 설계에 본 연구의 결과를 적용하는 방법에 대해 연구하였으며, 패널의 진공도는 패널과 배기장치의 형상에 강하게 의존하였다.

  • PDF

복사열 교란에 대한 고체 추진제 응답 함수의 FM 방법에 의한 수치적 계산

  • 김성인;이창진
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1999.04a
    • /
    • pp.22-22
    • /
    • 1999
  • 교란에 대한 고체 추진제의 연소율의 반등에 대한 이해는 고성능 추진제를 설계하는데 매우 중요한 요소이다. 그 동안의 연구는 고체 추진제의 표면에서 발생하는 교란이 매우 작은 크기로 발생한다는 선형적인 가정을 사용하여 이론적인 응답 함수를 구하였다. 특히 실험실에서 행해지는 교란에 대한 추진제의 응답 함수를 구하기 위하여 이용한 비집촉식 교란 방법을 사용하였다. 이 경우 추진제 표면으로 전달되는 복사열 전달의 크기는 레이저에 의한 복사 일전달과 기체 영의 화염에 의한 열전달을 동시에 고려하여야 한다. 그러나 언급하였던 것처럼 대부분의 이론적 연구는 추진제 표면의 온도 구매가 단열인 것으로 가정하여 진행하였다. 이러한 가정을 기체 영역으로부터 추진제로 전달되는 열전달 량이 작은 점소화초기 등에서 타당한 가정이나, 기체 영역에서 연소가 활발하게 진행되는 경우에는 비합리적인 가정이다. 본 연구에서는. 추진제의 응축 영역에서 분포 화학 반응이 발생하여, 기체 영역에서 화학반응에 의한 연소가 진행되는 경우, 복사 열전달의 교란에 대한 추진제의 응답함수를 수치적으로 계산하였다. 이때 기체 영역에서 발생하는 연소 반응은 De Luca 등에 의하여 제안된 실험적 모델인 $\alpha$ $\beta$ ${\gamma}$ 화염 모델을 사용하였으며, 추진제 표면에서의 열전달 균형에 의한 경계 조건을 사용하였다. 그러나 외부로부터 입사되는 복사광 레이저와 기체 영역의 상호 간섭은 고려하지 않았다. 수치 계산에 의한 응답 함수의 특징은 단열 조건이 사용된 이론적 응답 함수에 비하여 낮은 값을 나타내었으며, 최대치를 보이는 주파수 영역도 이론 함수에 비하여 다른 값을 보여주고 있다.연구 분석 결과 기술적 문제점으로는 배기 가스온도가 낮은데 따른 출구 부분의 Bearing, Sealing이 문제가 될 수 있다고 판단되며 배기 가스 자체에 대기 공기중에 함유되어 있던 습기가 얼어붙는(Icing화) 문제가 발생하기 때문에 배기가스의 Icing을 방지하기 위하여 압축기 끝단에서 공기를 추출하여 배기부분에 송출할 필요성이 있는 것으로 판단되었다. 출구가스의 기체 유동속도가 매우 빠르므로 (100-l10m.sec) 이를 완화하기 위한 디퓨저의 설계가 요구된다고 판단된다. 또 연소기 후방에 물을 주입하는 경우 열교환기 및 기타 부분품에 발생할 수 있는 부식 및 열교환 효율 저하도 간과할 수 없는 문제로 파악되었다. 이러한 기술적 문제가 적절히 해결되는 경우 비활성 가스 제너레이터는 민수용으로는 대형 빌딩, 산림, 유조선 등의 화재에 매우 적절히 사용되어 질 수 있을 뿐 아니라 군사적으로도 군사작전 중 및 공군 기지의 화재 그리고 지하벙커에 설치되어 있는 고급 첨단 군사 장비 등의 화재 뿐 아니라 대간첩작전 등에 효과적으로 활용될 수 있을 것으로 판단된다.가 작으며, 본 연소관에 충전된 RDX/AP계 추진제의 경우 추진제의 습기투과에 의한 추진제 물성 변화는 미미한 것으로 나타났다.의 향상으로, 음성개선에 효과적이라고 사료되었으며, 이 방법이 편측 성대마비 환자의 효과적인 음성개선의 치료방법의 하나로 응용될 수 있으리라 생각된다..7%), 혈액투석, 식도부분절제술 및 위루술·위회장문합술을 시행한 경우가 각 1례(2.9%)씩이었다. 13) 심각한 합병증은 9례(26.5%)에서 보였는데 그중 식도협착증이 6례(17.6%), 급성신부전증 1례(2.9%), 종격동기흉과 폐염이 병발한 경우와 폐염이 각 1례(2.9%)였다. 14

  • PDF