• Title/Summary/Keyword: 배관 진단

Search Result 105, Processing Time 0.028 seconds

The Generation of Torsional Waves and the Pipe Diagnosis Using Magnetostrictive Transducers (자기변형 트랜스듀서를 이용한 유도 비틀림파의 발생 및 배관의 이상진단)

  • 김윤영;박찬일;한순우;조승현
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.2
    • /
    • pp.144-149
    • /
    • 2004
  • The objective of this investigation is to develop an efficient method to generate and measure torsional waves in non-ferromagnetic waveguides by using magnetostrictive transducers. In existing methods using a nickel strip that is attached circumferentially to the test specimen, large current input to the magnetostrictive transducer often generates undesired wave modes in addition to the desired torsional wave. However, we propose a new method to generate the torsional waves without being accompanied with other undesirable wane modes regardless of the input current magnitude. The specific transducer configuration is suggested and its performance is also checked through a series of experiments.

The generation of torsional waves and the pipe diagnosis using magnetostrictive transducers (자왜 트랜스듀서를 이용한 유도 비틀림파의 발생 및 배관의 이상진단)

  • 박찬일;한순우;조승현;김윤영
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.544-548
    • /
    • 2003
  • The objective of this investigation is to develop an efficient method to generate and measure torsional waves in non-ferromagnetic waveguides by using magnetostrictive transducers. In existing methods using a nickel strip that is attached circumferentially to the test specimen such as aluminum pipes, large current input to the magnetostrictive transducer often generates undesired wave modes in addition to desired torsional wave. However, we propose an improved method to generate the torsional waves without being accompanied by other undesirable wave modes regardless of the input current magnitude. The specific transducer configuration and its performance will be presented in the present investigation.

  • PDF

A study on the architecture of a deep neural network to reduce the variance of predicted values in a regression problem (회귀 문제에서 예측값들의 분산을 줄이기 위한 딥뉴럴 네트워크 구조 연구)

  • Kim, Jonghwan;Yeo, Doyeob
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2022.07a
    • /
    • pp.11-14
    • /
    • 2022
  • 본 논문에서는 회귀 문제에서 예측값들의 분산을 줄이기 위한 딥뉴럴 네트워크 구조를 제안한다. 일반적인 회귀 문제에서 딥뉴럴 네트워크 학습 시, 하나의 입력에 대한 레이블 값을 이용하여 학습한다. 본 눈문에서는 하나의 입력에 대한 레이블 값뿐만 아니라 두 입력에 대한 레이블 값들의 차이를 학습시키는 딥뉴럴 네트워크 구조를 제안한다. 통계학 이론을 통하여 예측값들의 분산이 줄어든다는 것을 증명한다. 또한, 배관 곡관의 감육두께를 예측하는 문제를 통해 제안된 네트워크의 성능을 검증한다. 일반적인 딥뉴럴 네트워크 구조를 이용하였을 때에 비하여 제안한 네트워크 구조를 이용하였을 때, 회귀 문제의 예측값들의 분산이 감소함을 확인한다.

  • PDF

Mechanism Diagnosis and Avoidance Design on Transient Acoustic Vibration of Reheater Water Supply Piping in Supercritical Boiler (초임계 보일러 재열기 급수 공급배관의 과도 음향진동 진단 및 회피설계)

  • Kim, Yeon-Whan;Bae, Yong-Chae;Kim, Jae-Won;Lee, Doo-Young;Heo, Hae-Yong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.5
    • /
    • pp.385-393
    • /
    • 2013
  • In this paper, the mechanism identification and the avoidance measures on the phenomena of transient acoustic vibration amplified at the water-supply piping system to regulate the steam temperature of the boiler reheater in 500MW class supercritical power plant are presented. The pressure pulsation waves induced by the impeller passing of two feed-water pumps with five blades are coincident with the local acoustic modes of boiler reheater water-supply piping system. There are the phenomena amplified at the peaks of 5X, 10X, 15X and 20X in spectrums of piping vibration, sound pressure, and the feed-water's pressure pulsation waves. The shut-off device is installed in the piping system for the interception of pressure pulsation waves transmitted from two feed-water pumps and the modified design change of the piping layout is applied for the acoustic resonance avoidance. The acoustic natural frequencies are separated from the harmonics of pressure pulsation waves induced by the pump impellers passing through the design change of the span length. The acoustic vibration is gone by resonance avoidance measures. As a result, more than 20 dBA reduction is achieved from 100 dBA to 80 dBA.

Real Time Image Acquisition System using a Image Intensifier and Position Error Verification (영상증배관을 이용한 실시간 영상획득시스템과 위치오차검증)

  • Lee, Dong-Hoon;Kim, Nam-Hoon;Jeong, Jong-Beom
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.11 no.4
    • /
    • pp.331-338
    • /
    • 2017
  • In this study, a portable x-ray generator was manufactured and a real-time image acquisition system was constructed using the image intensifier from the generated generator. We have developed a real - time position error verification system that can verify whether the artificial joint position is different from the initial image from the acquired image. The template image of the region of interest is extracted from the reference image using the pattern matching technique and compared with the image to be compared. As a result, It is shown that real - time position error verification is achieved by displaying the difference angle. This system is portable type, has a self-shielding facility, and the output of the irradiation device can be manufactured in a small size of 1kw and can be used as a portable type. In case of emergency patients in the non-destructive field for industrial use, It has proved effective for use in small areas such as feet.

Monte Carlo Simulations of Detection Efficiency and Position Resolution of NaI(TI)-PMT Detector used in Small Gamma Camera (소형 감마카메라 제작에 사용되는 NaI(TI)- 광전자증배관 검출기의 민감도와 위치 분해능 특성 연구를 위한 몬테카를로 시뮬레이션)

  • Kim, Jong-Ho;Choi, Yong;Kim, Jun-Young;Im, Ki-Chun;Kim, Sang-Eun;Choi, Yeon-Sung;Joo, Kwan-Sik;Kim, Young-Jin;Kim, Byung-Tae
    • Progress in Medical Physics
    • /
    • v.8 no.2
    • /
    • pp.67-76
    • /
    • 1997
  • We studied optical behavior of scintillation light generated in NaI(TI) crystal using Monte Carlo simulation method. The simulation was performed for the model of NaI(TI) scintillator (size: 60 mm ${\times}$ 60 mm ${\times}$ 6 mm) using an optical tracking code. The sensitivity as a function of surface treatment (Ground, Polished, Metal-0.95RC, Polished-0.98RC, Painted- 0.98RC) of the incident surface of the scintillator was compared. The effects of NaI(TI) scintillator thickness and the refractive index of light guide optically coupling between the NaI(TI) scintillator and photomultiplier tube (PMT) were simulated. We also evaluated intrinsic position resolution of the system by calculating the spread of scintillation light generated. The sensitivities of the system having the surface treatment of Ground, Polished, Metal-0.95RC, Polished-0.98RC and Painted-0.98RC were 70.9%, 73.9%, 78.6%, 80.1% and 85.2%, respectively, and the surface treatment of Painted-0.98RC allowed the highest sensitivity. As increasing the thickness of scintillation crystal and light guide, the sensitivity of the system was decreased. As the refractive index of light guide increases, the sensitivity was increased. The intrinsic position resolution of the system was estimated to be 1.2 mm in horizontal and vertical directions. In this study, the performance of NaI(TI)-PMT detector system was evaluated using Monte Carlo simulation. Based on the results, we concluded that the NaI(TI)-PMT detector array is a favorable configuration for small gamma camera imaging breast tumor using Tc-99m labeled radiopharmaceuticals.

  • PDF

Evaluation of Shear Deformation Energy and Fatigue Performance of Single-layer and Multi-layer Metal Bellows (단층 및 다층 금속 벨로우즈의 전단 변형 에너지 및 피로성능 평가)

  • Kyeong-Seok Lee;Jin-Seok Yu;Young-Soo Jeong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.28 no.1
    • /
    • pp.39-45
    • /
    • 2024
  • Seismic safety of expansion joints for piping systems has been underscored by water pipe ruptures and leaks resulting from the Gyeongju and Pohang earthquakes. Metal bellows in piping systems are applied to prevent damage from earthquakes and road subsidence in soft ground. Designed with a series of corrugated segments called convolutions, metal bellows exhibit flexibility to accommodate displacements. Several studies have examined variations in convolution shapes and layers based on the intended performance to be evaluated. Nonetheless, the research on the seismic performance of complex bellows having multiple corrugation heights is limited. In this study, monotonic loading tests, cyclic loading tests, and fatigue tests were conducted to evaluate the shear performance in seismic conditions, of metal bellows with variable convolution heights. Single- and triple-layer bellows were considered for the experimentation. The results reveal that triple-layer bellows exhibit larger maximum deformation and fatigue life than single-layer bellows. However, the high stiffness of triple-layer bellows in resisting internal pressure poses certain disadvantages. The convolutions are less flexible at lower displacements and experience leakage at a rate related to the variable height of the convolutions in certain conditions. At lower deformation rates, the fatigue life is rated higher as the number of layers increase. It converges to a similar fatigue life at higher deformation rates.

Acceptance Test and Quality Control of Radiotherapy Treatment Simulator (의료용 모의치료기의 품질관리에 관한 연구)

  • 신동호;박성용;신동오;최진호;김유현;권수일
    • Progress in Medical Physics
    • /
    • v.13 no.2
    • /
    • pp.90-97
    • /
    • 2002
  • The simulator which has a identical geometry with radiotherapy equipments, is a essential equipment to accomplish optimized radiotherapy plan through simulation by using diagnostic low energy X-ray. A Radiotherapy simulator has a combined technology from the therapeutic and diagnostic radiology and needs a periodical test for mechanical and optical properties, X-ray generator, image intensifier of simulator to keep the proper maintenance and radiation safety. Hence, tests were done and classified as i) mechanical and optical parameter for the gantry, collimator, and couch ii) key performance of the X-ray generator such as a kVp, mAs, and timer iii) performance of the image intensifier such as a resolution and contrast for three kinds of simulator, common use in clinic. The above result of tests will be applied to the acceptance test and periodical quality assurance procedure.

  • PDF

Performance Analysis of Friction Damper Considering the Change of the Vertical Force (수직력의 변화를 고려한 마찰댐퍼의 거동 분석)

  • Cho, Sung Gook;Park, Woong Ki;Yi, Seong-Tae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.1
    • /
    • pp.59-66
    • /
    • 2017
  • In this paper, to protect the piping in nuclear power plants and various plant facilities, we have developed a damper using the friction method and carried out a study to analyze the performance. Friction typed damper means a device for attenuating vibration by generating a frictional force to the bearing and the shaft by applying a compressive force to the MER-Spring. In order to analyze the performance of the damper, the properties of MER-Spring and friction materials were analyzed, a study on the effects of friction was carried out, and the behavior of this equation was established. And, to determine whether deformation of the material and to examine the reliability of the behavior equation established, prototypes was produced and, through a performance test and finite element analysis of a damper made of specimens, they were analyzed. As a result, it is noted that the reliability of the material was confirmed, the coefficient of friction have to be adjusted according to the velocity, cyclic loading test and finite element analysis results show exhibits excellent results. In addition, a review of the dynamic loads in the future shall be performed for the usage in more broad fields.

In-depth investigation and improvement of cathodic protection system for water pipelines (상수도관로 전기방식 시스템의 진단 및 개선 사례)

  • Han, Chang-Dong;Lee, Seung-Yong;Jang, Jeong-Ho;Lee, Sang-Gun;Choi, Jun;Kim, Tea-Ho;Jung, Sung-Won;Li, Seon-Yeob
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2015_2016
    • /
    • 2009
  • 전기방식이 실시되고 있는 상수도 관로는 관의 노후화, 코팅의 열화, 부적절한 방식시스템의 적용 및 타 시설물과의 간섭 등으로 부분적으로 방식전위 미달구간이 존재한다. 이러한 방식전위 미달구간에 대하여 토양환경 측정 및 방식소요전류량 산정, 간섭 시험 등을 통하여 토양환경은 부식이 '발생하는 구간' 및 '미약하게 발생'하는 구간으로 나타났다. 임시 가통전 시험을 통하여 방식소요전류량을 구할 수 있었다. 간섭영향 시험으로 간섭 여부 및 전식 발생지점을 추정할 수 있다. 현장 측정 결과와 설계기준을 바탕으로 적절한 전기방식 보강 계획을 수립하여 현장에 부분적으로 설치하였으며 방식상태를 분석하였다. 단순히 설계된 소요전류량만을 증가시키는 방안보다 부분적인 방식보강 및 주변 배관 상태를 고려하여 적절한 통합 방식방안을 적용하는 것이 더 효율적인 것으로 나타났다.

  • PDF