• Title/Summary/Keyword: 배관제작

Search Result 159, Processing Time 0.028 seconds

Effect of tack of Fusion Defects on Short-Term Performance of Polyethylene Electrofusion Joints (폴리에틸렌 배관 전기융착부 단기성능 평가를 위한 융합물량 영향 평가)

  • Kil, Seong-Hee;Kwon, Jeong-Rock;Jo, Ji-Hwan
    • Journal of Energy Engineering
    • /
    • v.14 no.2 s.42
    • /
    • pp.153-158
    • /
    • 2005
  • In order to investigate the short-term performance of polyethylene electrofusion joints, the mechanical tests and stress analysis have been conducted to the artificially defected weld joints. The defects of lack of fusion with a square-type were fabricated with 10, 20, 30, 40, 50, 60$\%$ size of the width of heat-ing wire zone, respectively. In this defect sires range, both tensile and bending test results showed the dependence of defect size to the electrofusion joints performance, but both sustained pressure and crush test results didn't. The numerical stress analysis results including the soil and internal pressures, tensile and bend-ing stresses clearly showed the dependence of fusion defect size. Based on both mechanical test and stress analysis results, the maximum acceptable defect size in polyethylene electrofusion joints is discussed.

Development of a Multi-Channel Ultrasonic Testing System for Automated Ultrasonic Pipe Inspection of Nuclear Power Plant (원전 배관 자동 초음파 검사를 위한 다채널 초음파 시스템 개발)

  • Lee, Hee-Jong;Cho, Chan-Hee;Cho, Hyun-Joon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.2
    • /
    • pp.145-152
    • /
    • 2009
  • Currently almost all in-service-inspection techniques, applied in domestic nuclear power plants, are partial to field inspection technique. These kinds of techniques are related to managing nuclear power plants by the operation of foreign-produced inspection devices. There have been so many needsfor development of native in-service-inspection device because there is no native diagnosis device for nuclear power plant inspection yet in Korea. In this research, we developed several core techniques to make an automated ultrasonic pipe inspection system for nuclear power plants. A high performance multi-channel ultrasonic pulser/receiver module, an A/D converter module and a digital main CPU module were developed and the performance of the developed modules was verified. The S/N ratio, noise level and signal acquisition performance of the developed modules showed proper level as we designed in the beginning.

Experimental Study for the Reinforcement of District Heating Pipe (지역난방 열배관 강화를 위한 실증시험 연구)

  • Kim, Jaemin;Kim, Jooyong;Cho, Chongdu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.3
    • /
    • pp.245-252
    • /
    • 2016
  • In this study, an alternative bend design is proposed to overcome the aging problem in piping bends. In this design, the foam pad is not included. Finite element analysis was performed based on the total pipe diameter. From this analysis, the shape of the Shear Control Ring (SCR) was determined. Temperature, stress, and other data of the proposed reinforced pipe were acquired and analyzed after the test was performed. The value of the thermal stress for the reinforced steel pipe satisfied the required standard without the foam pad based on the manufacturing of the reinforced fitting and construction site of the test. The reinforcement provided a shear strength level for the foam pad that resulted in maximum shear stress less than stress based on the original foam pad applied at the pipe bend. Additionally, an increasing factor of safety effect for the reinforced fitting application was discovered.

Design and Manufacture of the air mixing system for supersonic ground test facility (초음속 지상추진시험설비의 공기 혼합시스템 설계 및 제작)

  • Lee, Yagn-Ji;Kang, Sang-Hun;Yang, Soo-Seok
    • Aerospace Engineering and Technology
    • /
    • v.7 no.1
    • /
    • pp.40-48
    • /
    • 2008
  • Air mixing system which is composed of air pressure control system, hot pipe system and air mixer, is the facility for mixing hot air($1000^{\circ}C$, 10kg/s) from storage air heater (SAH) and decompressed air($20^{\circ}C$, 15kg/s) from high pressure air supply system. Air pressure control system reduce the pressure of the air, from 32MPa to 3.5 MPa and supply the decompressed air to air mixer. The hot pipe system supply hot air from SAH to air mixer which mix hot with the decompressed air from air pressure control system. Fully mixed air flow rate is 25kg/s and mixed temperature is up to $400^{\circ}C$. So, we can expand the operating envelop of the supersonic ground test facility to low Mach number and low altitude region.

  • PDF

The Manufacture of Digital X-ray Devices and Implementation of Image Processing Algorithm (디지털 X-ray 장치 제작 및 영상 처리 알고리즘 구현)

  • Kim, So-young;Park, Seung-woo;Lee, Dong-hoon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.21 no.4
    • /
    • pp.195-201
    • /
    • 2020
  • This study studied scoliosis, one of the most common modern diseases caused by lifestyle patterns of office workers sitting in front of computers all day and modern people who use smart phones frequently. Scoliosis is a typical complication that takes more than 80% of the nation's total population at least once. X-ray are used to test for these complications. X-ray, a non-destructive testing method that allows scoliosis to be easily performed and filmed in various areas such as the chest, abdomen and bone without contrast agents or other instruments. We uses NI DAQ to miniaturize digital X-ray imaging devices and image intensifier in self-shielding housing with Vision Assistant for drawing lines to the top and the bottom of the spine to acquire angles, i.e. curvature in real-time. In this way, the research was conducted to see scoliosis patients and their condition easily and to help rapid treatment for solving the problem of posture correction in modern people.

Effects of Scintillation Crystal Surface Treatments on Small Gamma Camera Imaging (섬광체 옆 표면처리가 소형 감마카메라 영상에 미치는 효과)

  • Kim, J. H.;Choi, Y.;Kim, J. Y.;Oh, C. H.;Kim, S. E.;Choe, Y. S.;Lee, K. H.;Joo, K. S.;Kim, B. T.
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.6
    • /
    • pp.515-521
    • /
    • 1999
  • Scintillator crystal is an important part and detcrmines performance characteristics of the gamma camera. We investigated the offects of scintillation crystal surface treatment on gamma camera imaging. Nal(TI) and Csl(Tl) scintillators. 20 mm diameter and 10 mm thickness, applied with two different surface treatments, white and black reflcetors, were applied to Nal(Tl) and Csl(Ti). The optical properties of generated scintillation light were evaluated by Monte Carlo simulation method and by actual measurement using a position sensitive photomultiplier tube (PSPMT). We measured sensitivity, energy resolution and spatial resolution of gamma camera with the various scintillators coupled to a PSPMT. In the simulation. Nal(Tl)-white prosented the best sensitivity. In the measurements, the sensitivities and the intrinsic spatial resolutions of Nal(Tl)-white, Nal(Tl)-black. CsI(Tl)-white, CsI(Tl)-black were 2920, 2322, 1754, 1401 cps/$\mu$ci and 5.2, 4.5, 7.0, 6.3 mm FWHM. respectively. Their intrinsic energy resolutions were mesured 12.5, 23.5, 20.5, 33.3% FWHM at 140 keV Tc-99m. In this study, we investigated the offects of a side surface treatment of the scintillator on the gamma camera imaging. Simulation and measurement prescnted similat trends. Based on the results, we concluded that the surface of th NaI(Tl)seintillator must be treated by absorptive materials in order to develop the gamma camera having good spatial resolution.

  • PDF

Fabrication of Fiber-optics Detector for Measuring Radioactive Waste (방사성 오염도 측정을 위한 광섬유 검출기 제작)

  • Kim, Jeong-Ho;Joo, Koan-Sik
    • Journal of IKEEE
    • /
    • v.19 no.3
    • /
    • pp.282-287
    • /
    • 2015
  • In this study, an optical fiber detector was constructed by using a Ce:GAGG scintillator, optical fiber, and photomultiplier. The single crystal size of the scintillator was set to $3{\times}3{\times}20mm^3$ after simulating the counting efficiency of gamma rays in the scintillator by using the MCNPX code. The constructed detector used the standard gamma ray sources $^{137}Cs$ and $^{133}Ba$ to measure radiation and analyze the spectral characteristics of gamma rays. The resulting trend curve showed excellent linearity with an R-squared value of 0.99741, and the detector characteristics were found to vary 2% or less with distance based on comparison with the MCNPX value. Furthermore, the spectroscopic analysis of the gamma ray energy from the single-ray and mixed-ray sources showed that $^{137}Cs$ had its peak energy at 662 keV, and $^{133}Ba$ had at 356 keV. It seems that if the fiber-optics detector is used, working hours and exposure of worker can be reduced.

Current Issues on the Oil UST Management and Future Directions for the Prevention of the Subsurface Contamination (현행 주유소 지하유류저장시설 관리의 문제점과 토양${\cdot}$지하수 오염 방지를 위한 개선방안 연구)

  • Kim Meejeong
    • Journal of Soil and Groundwater Environment
    • /
    • v.9 no.4
    • /
    • pp.62-73
    • /
    • 2004
  • The current status and problems of UST management in gas stations were reviewed, and suggestions were made for possible improvement of UST management. Regulations and programs relevant through the whole life cycle of the UST, such as construction, installation, operation, and disclosure are insufficient to prevent oil release. The UST requirements are less stringent compared to those of the U.S. and EU members. Current soil test does not seem to be practically effective in detecting soil contamination caused by oil release. The potential for subsurface contamination due to oil release from the UST is estimated from available data other than soil test results. Much higher following future directions and suggestions are made to improve current unsatisfactory UST management: Firstly, increasing the UST requirements - establishing more stringent standards for new UST facilities, and adding new regulatory requirements for existing UST facilities; secondly, replacing current soil test with the tank and piping tests; thirdly, reinforcing programs for supervising the tank construction and installation; fourthly, constructing a system in which independent gas stations can properly manage the USTs; and lastly, educating UST owners and operators, and constructing DB of UST facilities.

Defect Depth Measurement of Straight Pipe Specimen Using Shearography (전단간섭계를 이용한 직관시험편의 결함 깊이 측정)

  • Chang, Ho-Seob;Kim, Kyung-Suk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.2
    • /
    • pp.170-176
    • /
    • 2012
  • In the nuclear industry, wall thinning defect of straight pipe occur the enormous loss in life evaluation and safety evaluation. To use non-destructive technique, we measure deformation, vibration, defect evaluation. But, this techniques are a weak that is the measurement of the wide area is difficult and the time is caught long. In the secondary side of nuclear power plants mostly used steel pipe, artificiality wall thinning defect make in the side and different thickness make to the each other, wall thinning defect part of deformation measure by using shearography. In addition, optical measurement through deformation, vibration, defect evaluation evaluate pipe and thickness defects of pressure vessel is to evaluate quantitatively. By shearography interferometry to measure the pipe's internal wall thinning defect and the variation of pressure use the proposed technique, the quantitative defect is to evaluate the thickness of the surplus. The amount of deformation use thickness of surplus prediction of the actual thickness defect and approximately 7 percent error by ensure reliability. According to pressure the amount of deformation and the thickness of the surplus through DB construction, nuclear power plant pipe use wall thinning part soundness evaluation. In this study, pressure vessel of thickness defect measure proposed nuclear pipe of wall thinning defect prediction and integrity assessment technology development. As a basic research defected theory and experiment, pressure vessel of advanced stability and soundness and maintainability is expected to contribute foundation establishment.

Flexural Behavior of Hybrid Beam of Reduced Story Height (층고 절감을 위한 하이브리드 보의 휨 거동에 관한 실험적 연구)

  • Hong, Sung-Gul;Yang, Dong-Hyun;Jung, Jong-Hyun;Yim, Byung-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.5
    • /
    • pp.557-567
    • /
    • 2007
  • In underground parking lots of apartment housing, the story height is increased by $300{\sim}400mm$ because of various ducts for HVAC. In order to reduce this story height, this study proposed the 'hybrid beam', which is composed of PC beam with embedded steel beam and insitu concrete. The depth of the hybrid beam is reduced by 300 mm and then the steel beam is embedded over the length of reduced depth to compensate for the loss of strength. Then, we performed the large-scale structural tests on 9 specimens and investigated the flexural behavior of the specimens. The parameters of tests were the shape of steel beam section, the length of the reduced depth, the stage of construction, the effects of slab and shear connectors. The test results showed that the specimens, after the insitu concrete has cured, has the flexural capacity which exceeds the required design capacity regardless of other parameters. On the other hand, the specimens of construction stage do not have sufficient strength. Based on these results, it is thought that the proposed hybrid beam with reduced depth is applicable to the underground parking lots of apartment housing as long as the support is placed at construction stage.