• Title/Summary/Keyword: 방염

Search Result 179, Processing Time 0.026 seconds

A Study on the Flame Resistance and Combustion Characteristics of MDF Plywood (MDF합판의 방염 및 연소특성에 관한 연구)

  • Kim, In-Beom
    • Korean Chemical Engineering Research
    • /
    • v.52 no.2
    • /
    • pp.256-260
    • /
    • 2014
  • Interior of the building is used as a MDF plywood if there is a fire in order to delay the ignition, flame retardant paint, flame retardant solution and flame retardant film are being handled by the flame retardant. Combustion characteristics anf flame retardant performance results can be summarized as follows: General film with a sample showed that short of the criteria in terms of carbonation area, and the results of flame retardant paint, flame retardant solution and flame retardant film products satisfied the criteria. Toxic gases generated in the combustion process results in a film samples using a high incidence of carbon monoxide and the creation of a smoke could be seen. This confirm that is estimated that result from incomplete combustion of PVC film that attach, and displays high toxicity index and hazard class relatively.

방염도료의 신뢰성 평가법 개발

  • Choe, Jeong-Jin;Park, Yun-Mi
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.84-85
    • /
    • 2013
  • 방염제품의 내구신뢰성은 국민의 화재 안전성 확보를 위한 필수 불가결의 요소로 이들 제품의 내구성능 예측은 방염성능의 지속적 유지를 위한 방염시설물 유지 관리 측면에서도 상당히 중요하다. 본 논문에서는 방염도료의 내구신뢰성 예측 및 확보를 위한 방염도료 가속수명법에 관한 연구로써, 방염도료의 고장 원인분석을 진행하였으며, 현장시험 및 현장 모사 실내 가속촉진시험을 진행하였다. 실내 가속촉진시험은 방염도료의 현장 주고장모드인 온 습도 사이클 시험으로 진행하였으며, 시험 척도로서 화학발광을 분석하여 적용하였으며 현장 데이터와 실내 촉진데이터와의 상관성 규명을 위하여 Mitab 등의 통계적 기법을 이용하여 고장유형 및 상관성을 규명하였다.

  • PDF

A Study on the Flame Retardant Performance and Toxicity of the Painting Wood Painted with Flame Retardant Solution (방염처리된 단청목재의 방염성능 및 유독성에 관한 연구)

  • Kim, In-Beom;Hyun, Seong-Ho
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.66-71
    • /
    • 2009
  • In this study, I evaluated toxicity that analyze performance of flame-retardant about flame-retardant painting wood and combustion gas that is based on the toxicity index. Processing condition of flame retardant solution and treatment method of samples didn't affect greatly to performance of flame retardant. Occurrence of combustion gas showed a almost similar result from the sample which spraying flame retardant solution and toxicity corresponds to high level, Hazard Class III, and the flame retardant solution saturation sample which makes put out Hazard Class II which is a low toxicity relatively.

A Study on Flame Retardant Performance of Vertical Blind and Roll Screen (버티칼 브라인드와 롤 스크린의 방염성능 유지에 관한 연구)

  • Jeong, Hyun Gyu;Cho, Woncheol;Lee, Tae Sik
    • Journal of Korean Society of societal Security
    • /
    • v.3 no.2
    • /
    • pp.41-46
    • /
    • 2010
  • This study focuses on two points. First, I have examined the difference on combustion between flame-retardant and non flame-retardant products including vertical blinds and roll screens that are widely used as a substitute for fabric curtains. The second point is to see how long flame-retardant goods can be durable, that is, flame retardant durability after washing in liquid. the experiment on the flame-retardant ability before and after washing of vertical blinds and roll screens that have been used for a long time in fire protection construct. Comparing and analyzing domestic and foreign laws on flame-retardant after the experiment on durability of these products. I aim to draw necessity for increased application of internal laws and regulations on flame-retardant and show how to improve the point at issue. According to the result, clear differences in performance and safety were observed between flame-retardant and non flame-retardant products. flame-retardant materials can prevent things from fire spread without igniting but melting when they've met flame and burnt, In contrast, non flame-retardant material for experiment which size is 120cm long takes less than 3 minutes only to be completely destroyed by fire. However, it was expected for flame-retardant durability of flame-retardant blinds which are not washable to decrease flame-retardant durability after being washed with water, there was no sharp difference. so it is demonstrated that flame-retardant blinds can keep flame-retardant durability. accordingly through the strict course of product we are concerned about keeping durability.

  • PDF

Flame Retardancy of Wood Products by Spreading Concentration and Impregnation Time of Flame Retardant (방염제의 도포량과 침지시간 차이에 따른 목재제품의 방염성능)

  • PARK, Sohyun;HAN, Yeonjung;SON, Dong Won
    • Journal of the Korean Wood Science and Technology
    • /
    • v.48 no.4
    • /
    • pp.417-430
    • /
    • 2020
  • The flame retardancy, such as carbonized length and area, of four plank type wood products by the spreading concentration and impregnation time of flame retardant were measured according to standard of the Nation Fire Agency in Republic of Korea. To measure the flame retardancy, Korean pine plywood, Japanese larch plywood, Japanese cypress planks, and perforated birch plywood boards were treated with self-development flame retardant by 300 and 500 g/㎡ spreading concentration and those were compared with control specimen. In general, the flame retardant performance of wood products improved as the spreading concentration of flame retardant increased. Except for Japanese larch plywood, there was no significant difference in the flame retardant performance by the spreading concentration. The flame retardant performance of perforated birch plywood board was positively correlated up to 60 minutes of impregnation time, but then gradually decreased. These results about the flame retardancy of wood products by spreading concentration and impregnation time were expected to be basic data for improving flame-retardant treated wood.

A Study on the Improvement of Fire Resistant performance Test about onsite Treated Materials (현장방염처리물품의 성능검사 개선에 관한 연구)

  • Lee, Sung-Eun;Kim, Hwang-Jin;Oh, Kyu-Hyung
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.124-127
    • /
    • 2008
  • 현장방염처리 물품의 방염성능평가시 실내 인테리어 공사가 끝난 후 시험 시료를 채취하여 연소시험을 실시하게 되어있다. 그러나 이러한 절차로 인해 검사 소요시간이 길어지고 여러 민원이 발생하여 이를 대처할 시험 방법이 필요하다. 따라서 연소시험 대신 도막두께 측정 시험 방법을 도입하여 방염성능평가에 따른 문제점들을 해결하고자 한다. 도막두께 측정 시험의 경우 도막두께 측정용 라벨을 방염도료를 칠해야 하는 합판이나 목재 위에 붙이고 도료 작업이 끝나고 나면 관할 소방서에 이 라벨을 떼어서 제출하여 기준 도막 두께와 비교 측정하였을 때 기준 도막두께보다 두꺼우면 방염성능을 인정해주고 만약 기준 도막두께보다 얇게 칠해지면 현장 검사 또는 시료 채취 후 연소시험을 병행하여 검사함으로서 안전하고, 책임 있는 방염성능 시공을 할 수 있도록 관리 감독할 수 있을 것이다.

  • PDF

Study for Vacuum Pressure Device for Flame Retardancy Pre-process of Wood (목재의 방염 선처리를 위한 진공가압장치에 대한 연구)

  • Kim, In-Beom;Cha, Jeong-Min;Hyun, Seong-Ho
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.408-411
    • /
    • 2012
  • 본 연구는 일상적으로 사용되고 있는 목재류와 섬유 및 플라스틱 등의 방염처리방법 중에서 목재와 같은 방염처리대상물을 방염화하는 방법으로 사용되고 있는 방염선처리 공정을 기준으로 하여 내장재 및 다양한 목재 활용제품에 대해 판매자가 사전에 방염처리를 진행할 수 있는 방염처리장치의 개발과 이를 활용한 제품의 방염성능 확인에 대한 결과를 설명하고 있으며 현장에서의 요구에 맞도록 설계된 장치를 통해 제품의 방염성능이 개선됨을 확인할 수 있었다.

  • PDF

A study on Combustion Characteristics of textiles flame retardant treatment (방염처리된 섬유류의 연소특성 연구)

  • Cha, Jeong Min;Kim, In Beom;Hyun, Seong Ho
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.156-157
    • /
    • 2013
  • 본 연구는 일상에서 사용되고 있는 섬유에 대하여 방염액을 사용한 후처리방법에 의해 방염처리를 진행하였을 때 섬유류의 구성비에 따른 방염성능 및 연소특성을 파악해 보고자 연구를 수행하였으며 화학섬유의 구성비 및 면의 함량에 따라 후처리의 방염성능이 달라짐을 확인할 수 있었다.

  • PDF

Fire Spreading Prevention of Straw-roofing House in Folk Village by Flame Resistant Treatment (민속마을 초가집의 방염에 의한 화재확산방지)

  • Park, Ho-Chun;Kim, Hwang-Jin;Lee, Seung-Hyun;Lee, Sung-Eun;Oh, Kyu-Hyung
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.52-57
    • /
    • 2010
  • Fire protection countermeasure were considered on the straw thatched roof and wooden structure. For the fire resistant treatment, rice straw was soaked in the fire resistant liquid with different soaking time. After treatment, some rice straw sample was washed with water then the rice straws were tested to check the fire resistance performance. And the wood was soaked in the fire resistant liquid at an atmospheric pressure, vacuum-pressure condition and painted with brush on the surface. To analyse the fire resistant performance of rice straw, ignition delay time was measured under the radiant heat flux of cone heater. And the fire resistant performance of wood samples were tested with 45 degree fire resistant test apparatus and cone heater. Based on the cone heater test, the rice straw which most easily ignitable material shows the longer ignition delay time than not treated ones and even in the water washed straw show a longer ignition delay time than not treated ones. And fire resistant treated woods of vacuum-pressure treated sample showed the most excellent performance on fire resistance. And the fire resistant treated by brush and soaking showed a longer ignition delay time than not treated ones. From this experiment, it was found that a fire resistant treatment of rice straw and wood of the house can be protected from the fire spread.

Flame Retardant and Weather Proof Characteristic of Dan-Chung Treated Wooden by Flame Retardant Performance (방염처리 방법에 따른 단청목재의 방염 및 내후특성)

  • Park, Cheul-Woo;Hong, Sang-Wan;Lee, Jong-Kyun;Lim, Nam-Gi
    • Journal of the Korea Institute of Building Construction
    • /
    • v.13 no.2
    • /
    • pp.122-130
    • /
    • 2013
  • One of recent methods to protect wooden cultural assets from fire, there is the flame retardation which is applied directly to wood and it is to prevent fire through securing flame resistance for the material and delaying combustion when failed fire in advance and then to gain time for people in the room to evacuate and it has same goal with the Korean Fire Service Act by protecting life and property. However, in case of spraying flame retardant on the colored surface of the wooden cultural assets, there are continuous problems of decoloration, efflorescence and water absorbtion after sometime and accordingly there increases danger of damages of cultural assets. So when treating with flame retardant on wooden cultural assets, there has to be no problems on dancheong after sometime and securing sustainable methods for flmae retardation should be preceded. Accordingly, this study aims to provide basic sources for selecting proper flame retardation methods by evaluating and analyzing flame retardation capabilities according to types of flame retardants which are frequently used nowadays and spraying them on the dancheong-painted surface and confirming if there is no problem on the dancheong and wood after sometime and if flame retardation effect is sustainable with its quality and capability through precise analysis.