• Title/Summary/Keyword: 방열율

Search Result 35, Processing Time 0.026 seconds

Implementation of Electrical and Optical characteristics based on new packaging in UV LED (UV LED의 광효율 및 방열성능 향상을 위한 new packaging 특성 연구)

  • Kim, Byoung Chol;Park, Byeong Seon;Kim, Hyeong-Jin;Kim, Yong-Kab
    • Smart Media Journal
    • /
    • v.11 no.9
    • /
    • pp.21-29
    • /
    • 2022
  • Ultra Violet(UV) is gradually being replaced with LED instead of general UV lamps. However, the light efficiency of UV LED is still lower than that of the general lamp, and the light efficiency is also low. Due to the current environment and technical problems of UV lamps, the LED replacements are gradually being made. In this study, a new package design and analysis were performed to increase the lifetime and performance of UV LEDs. A new packaging for UV LED were designed and implemented. The new packaging for UV LED was constructed to improve light efficiency. And the electrical and optical characteristics were analyzed respectively. To improve the optical efficiency in UV LED package, the Al has been used based on high reflectivity and applying the optimal lens focusing. Compared to the existing silver Ag, the light efficiency was improved by about 30% or more, and it was confirmed that the light output degradation characteristic was improved by about 10% in the newly applied optical device chip.

Comparative Study on the Thermal Insulation of Membrane LNG CCS by Heat Transfer Analysis (열전달 해석을 이용한 멤브레인형 LNG 화물창의 단열구조 성능비교)

  • Hwang, Se-Yun;Lee, Jang-Hyun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.1
    • /
    • pp.53-60
    • /
    • 2016
  • This study discusses the thermal insulation capacity of variant of NO96 LNG (liquefied natural gas) cargo containment insulation system. Changing the insulation materials and the insulation layers of conventional GTT NO96 containment system, The thermal resistance and BOR(boil off rate) caused by the heat transfer between cryogenic and environmental temperature is discussed. Therefore, thermal analysis of LNG CCS(cargo containment system) is carried out to determine the insulation capabilities. Also, BOR is evaluated in terms of the total amount of heat invaded into CCS(cargo containment system). Variant of NO96 CCS such as NO96, NO96GW and NO96L3 membrane type during laden voyage is selected for the comparative study. Finite element model for heat transfer analysis is conducted by employing the equivalent thermal resistance model to simplify the complex insulation layers. Finally the results for each variant model are relatively compared and discussed to minimize the BOR.

On-Board Black Body Thermal Design and On-Orbit Thermal Analysis for Non-Uniformity Correction of Space Imagers (영상센서의 비균일 출력특성 교정용 흑체의 열설계 및 궤도 열해석)

  • Oh, Hyun-Ung;Shin, So-Min;Hong, Ju-Sung;Lee, Min-Kyu
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.10
    • /
    • pp.1020-1025
    • /
    • 2010
  • On-board black body is used for radiation temperature calibration of spaceborne radiometers and imaging systems. The thermal design of black body proposed in this study is basically composed of heaters to heat-up the black body from low to high temperature during the calibration, heat pipe to transfer residual heat on the black body just after calibration to radiator on the S/C and heaters on the radiator to keep the certain temperature range of the black body during non-calibration. In the present work, the effectiveness of thermal design of on-board black body has been investigated by on-orbit thermal analysis.

A Study of Dust Effect on Performance of Heat Exchangers with Louver and Wavy Fins (루버형과 파형핀 열교환기에서 분진이 성능에 미치는 영향에 관한 연구)

  • Lee, Young-Lim;Hwang, Soon-Ho
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.4
    • /
    • pp.126-132
    • /
    • 2009
  • Automotive heat exchangers use louver fins for their high efficiency. However, the efficiency can significantly drop for constructional vehicles or heavy equipments due to dust deposited on the louver fins with narrow slits. Thus it is necessary to develop new fins that lead to less fouling, so that a better performance can be achieved after exposure to a dusty environment over long period of time. New wavy fins were considered in the study and numerically analysed to compare with louver fins in the areas of air-side pressure drop, heat release rate, and particulate deposition. In addition, an experiment was done on the pressure drop and the particulate deposition. The results showed that the wavy fins would be a better choice for long-term use due to the excellent dust-proof performance in comparison to louver fins, in spite of the initial inferior performance of heat release.

Numerical study on the thermal performance of passively cooled hybrid fins (수동적으로 냉각되는 하이브리드 휜들의 열성능에 대한 수치적 연구)

  • Jeon, Mun Soo;Kim, Kyoung Joon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.8
    • /
    • pp.816-821
    • /
    • 2013
  • This paper reports numerical study results with respect to the thermal performance of various hybrid fins (HFs) and a pin fin (PF) passively cooled under natural convection state. Investigated HFs are a basic hybrid fin (BHF), a hollow hybrid fin (HHF), and a solid hybrid fin (SHF). CFD models for both HFs and the PF have been developed to explore their thermal performance under various heat dissipations. Thermal performances of fins have been analyzed by quantifying array-based heat transfer coefficients, $h_a$, and mass-based heat transfer coefficients, $h_m$, for each fin. Study results show that $h_a$ of the SHF is 23% greater than that of the PF. $h_m$ of the HHF is found to be even 140% greater than that of the PF, and the HHF is found to be 40% better than the BHF in terms of the mass-based performance, $h_{m{\cdot}}$.

Numerical Study on the Thermal Design of Lunar Terrain Imager System Loaded on the Korea Pathfinder Lunar Orbiter (시험용 달 궤도선의 광학탑재체 시스템 열설계에 대한 수치해석적 연구)

  • Kim, Taig Young;Chang, Su-Young;Heo, Haeng-Pal
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.47 no.4
    • /
    • pp.309-318
    • /
    • 2019
  • The thermal design of the Lunar Terrain Imager (LUTI) on the Korean Pathfinder Lunar Orbiter (KPLO) was performed and the soundness of the thermal design was verified by thermal analysis. The thermal environment of the lunar mission orbit should be reflected in the thermal design because the IR radiation of the lunar surface is important, unlike the earth orbit. The components or modules exposed to the outside of the satellite are insulated with MLI as much as possible, but the camera tube and the radiator are functionally exposed, so the thermal shield using the concept of radiation shape factor is mounted on the front to mitigate IR radiation. The IR emissivity is important in the front side of the radiator that receives little solar radiation, and components that are susceptible to thermal deformation such as the tube use a radiation heater to minimize the temperature gradient. Through the investigation of computational results, it was confirmed that the thermal design of LUTI is stable in various situations.

Cooling Performance of Horizontal Type Geothermal Heat Pump System for Protected Horticulture (시설원예를 위한 수평형 지열 히트펌프의 냉방성능 해석)

  • Ryou, Young-Sun;Kang, Youn-Ku;Kang, Geum-Chun;Kim, Young-Joong;Paek, Yee
    • Journal of Bio-Environment Control
    • /
    • v.17 no.2
    • /
    • pp.90-95
    • /
    • 2008
  • It has become a big matter of concerns that the skill and measures against reduction of energy and cost for heating a protected horticultural greenhouse were prepared. But in these days necessity of cooling a protected horticultural greenhouse is on the rise from partial high value added farm products. In this study, therefore, a horizontal type geothermal heat pump system with 10 RT scale to heat and cool a protected horticultural greenhouse and be considered to be cheaper than a vertical type geothermal heat pump system was installed in greenhouse with area of $240\;m^2$. And cooling performances of this system were analysed. As condenser outlet temperature of heat transfer medium fluid rose from $40^{\circ}C$ to $58^{\circ}C$, power consumption of the heat pump was an upturn from 11.5 kW to 15 kW and high pressure rose from 1,617 kPa to 2,450 kPa. Cooling COP had the trend that the higher the ground temperature at 1.75 m went, the lower the COP went. The COP was 2.7 at ground temperature at 1.75 m depth of $25.5^{\circ}C$ and 2.0 at the temperature of $33.5^{\circ}C$ and the heat extraction rate from the greenhouse were 28.8 kW, 26.5 kW respectively at the same ground temperature range. 8 hours after the heat pump was operated, the temperature of ground at 60 cm and 150 cm depth buried a geothermal heat exchanger rose $14.3^{\circ}C$, $15.3^{\circ}C$ respectively, but the temperature of ground at the same depth not buried rose $2.4^{\circ}C$, $4.3^{\circ}C$ respectively. The temperature of heat transfer medium fluid fell $7.5^{\circ}C$ after the fluid passed through geothermal heat exchanger and the fluid rejected average 46 kW to the 1.5 m depth ground. It analyzed the geothermal heat exchanger rejected average 36.8 W/m of the geothermal heat exchanger. Fan coil units in the greenhouse extracted average 28.2 kW from the greenhouse air and the temperature of heat transfer medium fluid rose $4.2^{\circ}C$after the fluid passing through fan coil units. It was analyzed the accumulation energy of thermal storage thank was 321 MJ in 3 hours and the rejection energy of the tank was 313 MJ in 4 hours.

탄소섬유 상 Seed 입자의 결정구조에 따른 은나노구조체 형상 제어

  • Lee, Su-Min;Lee, Jae-Hyeok;Kim, Gwang-Beom;Kim, Seon-Min
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.383-383
    • /
    • 2012
  • 최근 나노 소재의 활용 가능성이 확대되어감에 따라 다양한 소재의 나노구조체에 대한 연구가 진행되어 왔다. 그 중 은(Silver)은 열전도율과 전기전도율이 가장 우수한 금속으로 다양한 형태의 은 나노 입자를 형성할 수 있고. 이를 탄소, 비석, 고분자 등의 기판에 다양한 방법으로 성장시키는 연구가 진행되었다. 기판으로 사용되는 재료 중 탄소 복합소재는 내열성, 화학적 안정성, 열전도성, 저열팽창성에 따른 치수 안정성, 유연성 등의 우수한 특징을 지니고 있으며 최근까지 방열 소재로서 활용되고 있다. 본 연구에서는 탄소섬유의 표면에 다양한 결정 구조를 가지는 Ag seed 입자를 형성하고 폴리올 공정을 통하여 와이어 형태의 나노구조체를 성장시켜 그 형상제어 특성을 FE-SEM을 통하여 확인하였다.

  • PDF

Development of Automatic Control System for Midnight Electric Ondol (축열식 전기온돌 공급시간자동제어시스템)

  • Park, S.;Jung, B.;Yu, S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.369-371
    • /
    • 2002
  • 기저부하조성 및 부하율 망상을 위한 심야 전력요금제도의 정착으로 최근 심야전력축열기기의 보급이 활성화되고 있다. 그러나 모든 심야전력축열기기들이 심야요금개시시간대인 22:00경에 동시에 가동됨에 따라 23:00경에 심야전력 부하가 최대에 이르러 전력피크가 발생하여 한전의 수요관리에 어려움을 주고 있다. 따라서 이 피크 부하를 심야전력 공급시간대의 저부하 시간대로 분산시킬 수 있는 심야전력기기 공급시간제어장치가 필요하게 되었으며, 이미 축열식전기보일러와 축열식 전기온수기에는 개발 보급되고 있는 실정이다. 이 논문에서는 다른 심야전력축열기기와는 달리 자연방열의 바닥축열난방방식인 축열식전기온돌의 공급시간자동제어장치 알고리즘을 실증실험을 통해서 검증하였다.

  • PDF

Development of Design Technology for Combined and Cogeneration Power Plant (복합열병합 발전 플랜트의 설계기술 개발사업의 추진 전략)

  • 오군섭
    • Journal of the KSME
    • /
    • v.35 no.6
    • /
    • pp.542-553
    • /
    • 1995
  • 복합열병합 발전 플랜트의 장점은 도시 근교에 발전 플랜트를 간단히 건설할 수 있으며, 공해를 크게 줄이면서 독립적인 발전이 가능하다는 측면에서 신도시, 신공업단지, 도서지방 등에서 아주 유리한 것으로 알려져 있다. 또한 가스 터빈 배기열을 이용하여 대규모 주거 지역이나 공업 단 지내에서 필요한 난\ulcorner냉방열이나 공업열원으로의 활용이 손쉬우며, 주변 시설이 복잡하지 않고, 개선된 연소기술에 의하여 공해를 크게 줄일 수 있다. 최근 들어 분당\ulcorner일산\ulcorner부천 지역 등에 열병합 플랜트가 건설되고 있으나 거의 모든 설계기술은 외국 기술에 의존되고 있으며, 국산화 율도 극히 저조하여 '93년도에 완공된 부천 화력(473MW)의 경우 약 30% 정도이다. 복합열병합 발전 시스템은 가스 터빈, 스팀 터빈 등의 터보기계 기술을 근간으로 하며, 열회수장치 및 열교 환장치의 설계기술, 각종 제어기술 등의 종합 설계기술로서 이미 선진국에서는 실용화된지 오 래되었으며 우리 나라에도 여러 종류의 플랜트가 도입되어 사용되고 있다.

  • PDF