• Title/Summary/Keyword: 방수규격

Search Result 15, Processing Time 0.028 seconds

Design of Interface Specification for Smart Buoys in Maritime Environment (해상 환경에 적합한 스마트 항로표지용 인터페이스 규격 설계)

  • Junsu Kim;Yangseop Kim;Sungyoon Cho;Donghyun Kim;Kiwon Kwon
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2023.11a
    • /
    • pp.180-181
    • /
    • 2023
  • 본 논문은 해양 환경에서 항로표지 내에 탑재되는 등명기, 배터리, BMS, 통신장치 등의 전원 공급 및 각 모듈들 간의 유선 데이터 통신에 사용할 수 있는 커넥터 인터페이스 규격을 제시한다. 제안하는 규격은 M12 커넥터 규격을 이용하여 내구성을 확보하고 방수방진을 지원한다. 이를 통해 극한의 온·습도에 노출되며 태풍, 파도 등의 변수가 많은 해양 환경에서의 안정적인 연결성 유지를 기대할 수 있다.

  • PDF

An Empirical Study on the Standard Re-establishment of Water Discharge Performance for the Fire Engine Pump (소방차 펌프의 방수성능 기준 재정립을 위한 실증적 연구)

  • Min, Se-Hong;Kwon, Yong-Joon
    • Fire Science and Engineering
    • /
    • v.26 no.5
    • /
    • pp.85-91
    • /
    • 2012
  • This paper analyzed firefighting officers' use situations such as the use time, maximum working pressure, hose diameter, etc. of fire pumps at fire sites and carried out various performance tests by pressures, hose diameters and quantities of fire pumps based on its results because the waterproof performance criterion for a fire pump installed in a fire engine is different from the operation situations at the site and is not clearly prescribed. As a result of site survey, the site uses a higher pressure than the standard water discharge pressure (0.85 MPa) or the high-pressure water discharge pressure (1.4 MPa) prescribed by the approval Standard of the fire pump performance on fire truck. In addition, as a result of pump performance test, the discharged water flow rate, water discharge pressure, etc. was measured to be very different from the currently prescribed the approval standard depending on the hose diameter and firefighting nozzle, so the result of this study proposes a new standard.

Design Guide of Surface and Watertight LED Luminaires for Naval Vessels (함정용 노출.방수형 LED 조명기구의 설계 방안)

  • Kil, Gyung-Suk;Kim, Il-Kwon;Cho, Hyang-Eun;Kwon, Hyuk-Sang;Cho, Heung-Gi
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.5
    • /
    • pp.654-660
    • /
    • 2011
  • This paper dealt with a design guide of LED luminaires to replace the surface and watertight fluorescent lamp (FL) fixtures for naval vessels. Several standards such as Korean Industrial Standard (KS), Korea Defence Standard (KDS) and US Military Standard (MIL) were compared in terms of safety and performance of lighting fixtures. The electrical and optical characteristics like power consumption, total luminous flux, and illumination distribution of the FL fixtures were experimentally analyzed to acquire design rules for LED luminaires. Based on the results, four types of LED luminaires were fabricated, and we proposed a design guide of LED luminaires for naval vessels which save power consumption of 44~51 [%] and increase total luminous flux of 8~13 [%].

PE의 요철형 PANEL을 이용한 방수. 방식 공법에 관한 연구

  • 박태인;김두환
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1999.06a
    • /
    • pp.187-191
    • /
    • 1999
  • 공사현장에서 사용하고있는 거푸집의 대체를 오랫동안 연구 끝에 가로(60cm) 세로(120cm)의 규격의 PE-FORM을 개발한바 있으나, 일반 건설 현장에서 어떠한 형태의 구조물 시공을 위한 형틀을 제작함에 있어 통상적으로 기존 합판거푸집을 사용하고 있으나, 현재 국내에서 사용되고 있는 합판은 전량 수입에 의존하고 있어 외화낭비가 심할 뿐 아니라 평균 2-3회 정도밖에 사용하지 못해 자원 낭비를 초래하고 있으며, 합판 거푸집을 사용한 경우, 목공이 구조물의 형태에 맞춰 FORM을 일일이 제작해야하므로 시간과 비용의 소모가 크고 또한 FRP-FORM, EURO-FORM, STEEL-FORM GANG-FORM SYSTEM-FORM 등 구조물의 성격 형태에 따라 각종 개량된 거푸집을 사용한다고 해도 그것은 단순한 구조물의 형상을 만들어 내기 위한 형틀로써만이 이용되고 있을 뿐, 그 이상의 목적으로는 활용 할 수 없기 때문에 구조물의 특성상 방수 방식의 기능이 요구될 경우, 거푸집 해체 후 벽체의 내부 또는 외부에 액체, 몰탈, 에폭시, 쉬트 방수등 별도의 후속 공정이 추가되 번거로움이 있는 반면, 그 효과는 기대에 크게 미치지 못하고 있는 점을 착안, 수년 전부터 연구에 착수, 콘크리트 구조체의 방수ㆍ방식 문제를 해결 할 수 있는 획기적인 공법의 PE-PANEL의 요철형 거푸집 및 방수ㆍ방식공법을 개발해내는데 성공함으로써 지금까지 난제로만 여겨졌던 목재 거푸집의 대체 자재개발과 아울러 거푸집 겸 콘크리트 표면의 마감 처리을 동시에 해결한 매우 혁신적인 신기술이라 할 수 있다. (중략)

  • PDF

A Study on the Quality Control Plan for Waterproof Construction in Apartment Houses (공동주택 방수공사 품질관리 방안 마련에 관한 연구)

  • Kim, Kwang-Ki;Kim, Byoungil
    • Journal of the Korea Institute of Building Construction
    • /
    • v.24 no.1
    • /
    • pp.109-120
    • /
    • 2024
  • For successful waterproofing construction, it is very important to secure construction quality as well as material performance of waterproofing materials used in construction. Due to the long-term cost reduction policy following the economic downturn in the construction market, most construction companies are using general low-priced waterproof materials rather than high-quality waterproof materials without clear quality control standards. Without clear education on construction, construction is being carried out with meaning only on construction activities. In addition, the waterproofing method applied in combination is a situation where water leakage occurs due to waterproofing failure due to insufficient construction quality because the construction method is complicated. Therefore, it is necessary to review the quality control measures(design, materials, construction) for successful waterproofing work and improve problems that are derived so that stable waterproofing work can be done. In order to expect the leakage prevention effect of a building, first, it is required to select appropriate materials for each part of the building and environment in the design stage, and the selected materials must satisfy all items of the Korean Industrial Standard(KS). Second, to secure the quality of waterproofing construction, sincere construction by workers is required. In this paper, we tried to describe "review of waterproof design", "constructor education", "site inspection", and "criticism(correction/supplementation)" as quality control measures after material selection.

Investigation on Products and Regulation of Flexible Adhesive Rubber Asphalt Type Sealant for the Development of Korea-China Joint Standard (점착유연형 고무아스팔트계 씰재의 한중 공동 품질관리 규정 개발을 위한 제품 및 기술기준 현황 조사)

  • An, Ki-Won;Kim, Dong-Bum;Choi, Su-Young;He, Xing-Yang;Oh, Sang-Keun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.7 no.4
    • /
    • pp.323-332
    • /
    • 2019
  • Non-curable rubberized polymer asphalt waterproof coating materials in Korea and China are manufactured without advanced quality control techniques and common standard, And they are exposed consistent water leakage problems. Import and application of Korean waterproofing products and installation methods is difficult in the present situation as the Chinese standard(JC/T 2428) is different in nature with the Korean counterpart products, And quality assurance is inevitable based on mutual standards. In order to resolve this issue, alternatives such as using standards provided by the ISO (International Organization for Standardization) are generally employed, but there is no such ISO standard as a waterproof material for non-curable rubberized polymer asphalt material. Furthermore, it is unreasonable to develop the ISO standard for rubber asphalt seals for exchange in terms of time and cost. This study proposes that the establishment of a quality standard that can be applied for both countries will be required via an joint international standard that outlines the properties of materials if applied in mutual trade exchange.

A Design of the Cat's Eye System with Low Power Consumption Using Solar Energy (태양광을 이용한 저전력의 LED 표지병 설계)

  • Kim, Keun-Sik;Kim, Jong-Hoon
    • Journal of Digital Convergence
    • /
    • v.14 no.1
    • /
    • pp.181-187
    • /
    • 2016
  • Typical Retro-reflectors installed on road have problems such as limiting a driver's visibility at night when it is foggy or rainy. On the other hand, LED illuminated studs, called cat's eye system, extends a driver's visibility under these conditions. In this paper, we present a design of the LED cat's eye system using solar energy that can sustain vehicles with about 30-ton weight and is compliant with the IP68 code for water proof as IEC standard 60529. In addition, we propose a scheme of designing a LED driving circuit consuming low power to take into accounts cold weather or rainy season with limited sunlight. This LED cat's eye studs is currently installed and used on expressway and bike route nationally as well as overseas.

Verification and Improvement of Structural Behavior Response Performance Evaluation Method for the Standard Establishment of Adhesive Composite Waterproofing Sheets (점착형 복합 방수시트의 표준(안)제정을 위한 구조물 거동대응성능 시험방법 개선 및 검증 평가 연구)

  • Kim, Soo-Yeon;Park, Jong-Sun;Oh, Sang-Keun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.4
    • /
    • pp.377-386
    • /
    • 2021
  • In April 2019, this study was enacted as a test method for the performance of waterproof layers in an environment where complex deterioration and structural behavior are simultaneously applied, but some existing standards were implemented to point out the errors of the method that should be supplemented. Thus, in establishing standards for (tentative) adhesive waterproofing sheets, field workability and quantification of test results were studied on the structural behavior response performance test methods included as test items. In addition, the performance evaluation of adhesive-type composite waterproof sheets was conducted based on the considered contents to review improvements such as applicability as an item of standard standards and field workability related problems.

A Study on Introduction to Performance based Design of Sprinkler Installation on Risk Level for Individual Occupancy in Korea (공간용도별 위험등급기반의 스프링클러헤드 성능 설계기법의 국내적용 연구)

  • Lee, Young-Jae;Park, Hyung-Joo
    • Fire Science and Engineering
    • /
    • v.26 no.2
    • /
    • pp.1-10
    • /
    • 2012
  • While a performance based sprinkler design method has been widely used in UK and USA according to fire hazards of occupancies, Korean fire safety industry could not yet accept it due to nonstandardization on risk level of various occupancy. Even only two or three spray pattern sprinkler was produced in Korea fire safety industry, therefore, various spray pattern sprinklers have not yet introduced to major occupancies. Spray pattern sprinklers with one of two K value have been used in all occupancies in Korea Market. UK and USA's Fire industry should produced the spray sprinklers with various K-factors and protection area due to performance based sprinkler design requirement. Therefore the fire load density for main occupancies has been investigated in order to compare with installation standard in advanced countries. Eventually a lot of variations in orifice and K factors of standard heads were set up including special heads needed for high hazard areas such as large drop type, enlarged orifice type and early suppression fast response.

A study on the Properties of Composite Systems Using Polymer-Modified Mortar and Epoxy Resins for Waterproofing and Anti-Corrosion of Concrete Structures (시멘트 혼입 폴리머와 에폭시수지를 복합한 수처리 콘크리트구조물용 방수방식재료의 성능평가에 관한 연구)

  • Bae Kee-Sun;Jang Sung-Joo;Oh Sang-Keun
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.1 s.85
    • /
    • pp.3-10
    • /
    • 2005
  • The purpose of this study is to investigate the properties of composite systems using polymer cement and epoxy resins for waterproofing and anti-corrosion to concrete structures such as water supply facilities and sewage-works. For the waterproofing and anti-corrosion of concrete structures, there can be required various properties such as absorption capacity and water permeability, adhesion and tensile strength, hair crack-resistance, impact-resistance, repeated low and high temperature test and chemical resistance, soundness for drinking water, soundness for drinking water and etc. In this study these engineering properties of composite systems using polymer-modified mortar and epoxy resins were examined and could be confirmed to satisfy the guidelines of KS. Especially, it was turn out that the adhesion properties was excellent and high crack-resistance up to 1.49 mm will be perform.