• Title/Summary/Keyword: 방사에너지

Search Result 751, Processing Time 0.02 seconds

Simulation of Asymmetric Fuel Thermal Behavior Using 3D Gap Conductance Model (3 차원 간극 열전도도 모델을 이용한 핵연료봉의 열적 비대칭 거동 해석)

  • Kang, Chang Hak;Lee, Sung Uk;Yang, Dong Yol;Kim, Hyo Chan;Yang, Yong Sik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.3
    • /
    • pp.249-257
    • /
    • 2015
  • A fuel assembly consists of fuel rods composed of pellets (UO2) and a cladding tube (Zircaloy). The role of the fuel rods in the reactor is to generate heat by nuclear fission, as well as to retain fission products during operation. A simulation method using a computer program was used to evaluate the safety of the nuclear fuel rods. This computer program has been called the fuel performance code. In the analysis of a light water reactor fuel rod, the gap conductance, which depended on the distance between the pellets and cladding tube, mainly influenced the thermomechanical behavior of the fuel rod. In this work, a 3D gap element was proposed to simulate the thermo-mechanical behavior of the nuclear fuel rod, considering the gap conductance. To implement the proposed 3D gap element, a 3D thermo-mechanical module was also developed using FORTRAN90. The asymmetric characteristics of the nuclear fuel rod, such as the MPS (missing pellet surface) and eccentricity, were simulated to evaluate the proposed 3D gap element.

Effect of Ni Catalyst Thickness on Carbon Nanotube Growth Synthesized by Hot-filament PECVD (Ni 촉매층의 두께가 탄소나노튜브의 성장 형태에 미치는 영향)

  • Kim, Jung-Tae;Park, Yong-Seob;Kim, Hyung-Jin;Choi, Eun-Chang;Hong, Byung-You
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.2
    • /
    • pp.128-133
    • /
    • 2007
  • In this study, we observed the shapes of CNTs formed with the thinckness of catalyst. Catalyst layer was grown by magnetron sputtering method and the thickness of Ni catalyst is the range from 20 to 80 nm. Also, the synthesis of CNT with Ni catalyst thickness was grown by hot-filament PECVD method. And, we investigated the composition of CNTs by using EDS measurement, also observed the shapes of CNTs by using HRTEM and FESEM measurements. In the result, through the TEM analysis, we observed the empty inside of CNTs and the multiwall CNTs, also confirmed the tip of CNT containing Ni. The composition of CNTs are consisted of an element of C, Ti, and Ni. As you shown the growth shapes of CNTs, the pretreatment of the catalyst before te growth of CNTs changed the particle size of the catalysts and grown the CNTs of the different shapes. Consequently, the best vertically alined and well-arranged CNTs exhibited from the substrate deposited at the catalyst thickness of 40 nm.

An Application of $^{13}C$ Tracer for the Determination of Size Fractionated Primary Productivity in Upper Stream of Lake Shihwa ($^{13}C$ 추적자를 사용한 시화호 상류역에서의 식물플랑크톤 크기에 따른 1차생산성 측정에 관한 연구)

  • Lee, Yeon-Jung;Kim, Min-Seob;Won, Eun-Ji;Shin, Kyung-Hoon
    • Korean Journal of Ecology and Environment
    • /
    • v.39 no.1 s.115
    • /
    • pp.93-99
    • /
    • 2006
  • Primary productivity was determined by using $^{13}C$ tracer according to different cell size of phytoplank-ton through in situ incubation experiments in upper stream of the Lake Shihwa. The average concentration of chlorophyll a was 14 ${\mu}g\;L^{-1}$ demonstrating an eutrophic water. The ratio of POC/Chl-a was lower than 30, reflecting that the origin of organic matter might be mainly phytoplankton. The primary productivity was 93.9 mgC m^{-2}\;d^{-1}$ at St. 1, which was about 40-fold lower than the average value of the lake (3,972 mgC m^{-2}\;d^{-1}$) determined by Choi et al. (1997) before opening of gate but it was higher than the average primary productivity (3.98 mgC m^{-2}\;d^{-1}$) reported by KOWACO in 1993 before constructing dam. The fractionated size (20 ${\sim}$ 53 ${\mu}m$) of phytoplankton community account for 51% of total primary productivity, indicating the highest assimilation rate. This study suggest that $^{13}C$ tracer methodology should be applied as a useful approach for the water ecological research in the future.

Effects of Gas Background Temperature Difference(Emissivity) on OGI(Optical Gas Image) Clarity (가스의 배경 온도 차이(방사율)가 OGI(Optical Gas Image)의 선명도에 미치는 영향)

  • Park, Su-Ri;Han, Sang-Wook;Kim, Byung-Jick;Hong, Cheol-Jae
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.5
    • /
    • pp.1-8
    • /
    • 2017
  • Currently gas safety management in the industrial field has been done by LDAR as contact method or methane leak detector as non-contact method. But LDAR method requires a lot of man-power and methane leak detector have the limitation of methane only. Therefore the Research on the OGI(optical gas image) has big attention by industry. This research was undertaken to see the effect of background temperature difference of gas cloud on the clarity of OGI. The background temperature control panel was constructed to cool down the background temperature. OGI was taken at the various methane gas ejection rate and the designed temperature difference. The experimental results showed that the OGI(when the temperature difference is $-6^{\circ}C$) is more clear thane the OGI(when the temperature difference is zero). To quantify the clarity difference, MATLAB's RGB analysis method was employed. The RGB value of the OGI at ${\Delta}T-6^{\circ}C$ was 20% lower than the OGI at ${\Delta}T0^{\circ}C$. The clarity difference by T difference can be explained by the total radiation law. When the background temperature of the gas is lower than the air temperature, the radiation energy coming into the OGI lens is increasing. As the energy is increasing, the OGI image becomes clear.

Integrated Ray Tracing Model for In-Orbit Optical Performance Simulation for GOCI (통합적 광추적 모델에 의한 해양탑재체 GOCI의 궤도 상 광학 성능 검증)

  • Ham, Seon-Jeong;Lee, Jae-Min;Kim, Seong-Hui;Yun, Hyeong-Sik;Gang, Geum-Sil;Myeong, Hwan-Chun;Kim, Seok-Hwan
    • Journal of Satellite, Information and Communications
    • /
    • v.1 no.2
    • /
    • pp.1-7
    • /
    • 2006
  • GOCi (Geostationary Ocean Color Imager) is one of the COMS payloads that KARI is currently developing and scheduled to be in operation from around 2008. Its primary objective is to monitor the Korean coastal water environmental condition. We report the current progress in development of the integrated optical model as one of the key analysis tools for the GOCI in-orbit performance verification. The model includes the Sun as the emitting light source. The curved Earth surface section of 2500 km x 2500 km includingthe Korean peninsular os defined as a Lambertian scattering surface consisted of land and sea surface. From its geostationary orbit, the GOCI optical system observes the reflected light from the surfaces with varying reflectance representing the changes in its environmental conditions. The optical ray tracing technique was used to demonstrate the GOCI in-orbit performances such as red tide detection. The computational concept, simulation results and its implications to the on-going development of GOCI are presented.

  • PDF

Feature Vector Extraction and Classification Performance Comparison According to Various Settings of Classifiers for Fault Detection and Classification of Induction Motor (유도 전동기의 고장 검출 및 분류를 위한 특징 벡터 추출과 분류기의 다양한 설정에 따른 분류 성능 비교)

  • Kang, Myeong-Su;Nguyen, Thu-Ngoc;Kim, Yong-Min;Kim, Cheol-Hong;Kim, Jong-Myon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.30 no.8
    • /
    • pp.446-460
    • /
    • 2011
  • The use of induction motors has been recently increasing with automation in aeronautical and automotive industries, and it playes a significant role. This has motivated that many researchers have studied on developing fault detection and classification systems of an induction motor in order to minimize economical damage caused by its fault. With this reason, this paper proposed feature vector extraction methods based on STE (short-time energy)+SVD (singular value decomposition) and DCT (discrete cosine transform)+SVD techniques to early detect and diagnose faults of induction motors, and classified faults of an induction motor into different types of them by using extracted features as inputs of BPNN (back propagation neural network) and multi-layer SVM (support vector machine). When BPNN and multi-lay SVM are used as classifiers for fault classification, there are many settings that affect classification performance: the number of input layers, the number of hidden layers and learning algorithms for BPNN, and standard deviation values of Gaussian radial basis function for multi-layer SVM. Therefore, this paper quantitatively simulated to find appropriate settings for those classifiers yielding higher classification performance than others.

A Case Study on Impact Factor of Bridge in Tunnels Subjected to Moving Vehicle Load (터널내 교량의 이동차량하중 작용시 충격계수에 대한 사례연구)

  • 김재민;이중건;이익효;이두화
    • Tunnel and Underground Space
    • /
    • v.9 no.3
    • /
    • pp.185-193
    • /
    • 1999
  • This paper presents results of dynamic analysis for a bridge in intersection part of two tunnels subjected to moving vehicle load. Since such a bridge system is very unusual due to the fact that it is located in tunnel, the dynamic characteristics of the structure can not be assumed as conventional one. The structure investigated in this study it a reinforced concrete bridge in the intersection part of Namsan Tunnel-1 and Tunnel-2 in Seoul. It is supported by temporary steel structure which shall be constructed during the period of replacing lining in Tunnel-2. Dynamic analysis was carried out for the system using a finite element model constructed by general purpose FE program SAP2000. For this purpose, the structure, lining of tunnels, and surrounding rock were represented by finite elements, while the rock region it truncated and on its outer boundary viscous dampers were placed to simulate radiation of elastic waves generated tunnels. Several types of vehicle with various driving velocities were considered in this analysis. The FE model including vehicle loadings was verified by comparing calculated peak particle velocity with the measured one. From the analysis, the impart factor for the bridge was estimated as 0.21, which indicates that the use of upper bound for the impact factor in design code is reasonable for this kind of bridge system.

  • PDF

A Study on Quantitative Thickness Evaluation Using Film Density Variation in Film Radiography (Film Radiography에서 농도차를 이용한 정량적 두께 평가에 관한 연구)

  • Lee, Sung-Sik;Lee, Jeong-Ki;Kim, Young-H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.5
    • /
    • pp.356-362
    • /
    • 1999
  • Based on the assumption that film density increases exponentially with exposure in the industrial radiographic film. an equation representing the characteristic curves of industrial radiographic films and a new density-thickness relation are suggested. The accuracy and reliability of the suggested relation has been tested using radiographs of a carbon steel step wedge with known thickness variation by polychromatic X-ray and ${\gamma}$-ray ($Ir^{192}$). The experimental results were well agreed to the proposed relation in the range of film densities from 1.0 to 3.5 and it was more accurate than the conventional relation. It is also found that ${\gamma}$-ray is more effective in this purpose than polychromatic X-ray, which results in variation of effective linear absorption coefficient due to beam hardening effect as thickness increases. Therefore using the equation and experimentally determined parameters the quantitative evaluation of thickness variation is possible and it can be used to evaluate the depth of local corrosion of pressure vessels in plants.

  • PDF

Analysis of Counting Rate according to Presence or Absence of Detector's Protector in Beta-rays Measurement using Geiger-Muller Counter (Geiger-Muller 계수관을 이용한 베타선측정에서 디텍터 보호유무에 따른 계수율 분석)

  • Jang, Ji-Yong;Jeong, Moon-Taeg;Song, Jong-Nam;Ha, Jae-Jun;Han, Jae-Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.31-37
    • /
    • 2018
  • In the surface contamination test using the end-window Geiger-Muller type counter, the wrap is used as a method for protecting the detector exposed to the outside in order to measure the beta-rays. We analyze the effect of this method on the measurement rate and the correction factor, and wanted to make it clear to radiation workers that excessive use of the wrap can affect the measured value of the beta-rays. The experimental method was to compare and analyze the change of the beta-rays measurement counting rate and the calibration factor according to the wrap thickness using the beta-rays with different energy of 3 KBq, 1.5 KBq and 0.3 KBq. The subjects of this study were the end-window Geiger-Muller type counter which were held at the calibration center certified by Korea Laboratory Accreditation Scheme (KOLAS) in March 2012, Cl-36 (Chlorine) and Sr-90 (Strontium) were used as the source of beta radiation. The measurement counting rate decreased with increasing wrap thickness, and the calibration factor increased with increasing wrap thickness. Since the changes of the measurement counting rate and the calibration factors can reduce the accuracy of the instrument readings, but also have a significant impact on detector contamination and damage, so there is a need to find out what thickness of wrap is most effective. If we using a wraps with thickness that show a low rate of change of the measurement counting rate and the calibration factor, it will protect the detector and minimize the effect on the measured value of the beta-rays.

Professional Nursing Quality Assurance (전문직 간호의 질적보장)

  • Kim, Hea-Sook
    • Journal of Korean Academy of Nursing
    • /
    • v.22 no.2
    • /
    • pp.248-259
    • /
    • 1992
  • 질적 보장은 전문직 종사자에 의하여 수혜받는 대상자를 보호하기 위하여 전적으로 필요한 프로그램이다. 이러한 질적보장을 통하여 전문직의 자율성과 책임을 튼튼히 할 수 있는 의무는 전문직 종사자 모두의 관심사가 되어야 한다. 미국에 있어서 질적 간호에 대한 관심은 이제 새로운 이유가 아니다. Beyers(1988)는 건강체계 지도자 사이에 가장 중요한 문제로 강조하는 것이 수혜자의 이용의 용이성(Access), 숫가(Cost) 그리고 질적인 제공(Quality)이 라고 피력 하였다. 미국 건강사업 평가자와 조정자(Regulator)들은 질(Quality)을 위한 자율적인 프로그램에 많은 에너지를 투입하여 전반적인 건강사업 즉 의료계의 질보장, 더 나아가서는 간호의 질을 향상 시키기 위한 많은 프로그램을 분석 연구한다. 이 논문은 간호에 있어서 질적 보장을 위한 내용으로 주요점은 질적 보장에 사용되는 용어, 역사적 배경, 질적 보장을 강조하는 이유, 질적 보장제도의 개발, 질 사정(euali assessment)과 질적 보장에 있어서 간호 전문직 개입을 차례대로 설명하였다. 구미의 경우 1970년대부터 간호직에 있어서는 질적보장제도개발에 우선순위를 두게되어 미 간호협회에서는 Professional Standards Review Organizations (PSRO)에 근거하여 간호실무를 위한 표준을 내어놓았다. 질적보장을 위한 평가방법으로 구조, 과정, 결과 그리고 수혜자가 간호계획을 세우는데 사정에 참여하는 방법 등 4가지를 간략하게 설명하였다. 질적 보장을 향상시키기 위해서는 전문직과 공공의료기간이 서로 협동체가 되어 중추역할을 해야함을 강조하고 이렇게 서로 협력하므로써만이 비로서 우리의 목적을 성취할 수 있다고 생각된다.구 등이 이용된다. $^{166}$ Ho, $^{198}$ Au, $^{32}$P, $^{90}$ Y, $^{169}$ Er, $^{186}$ Rc, $^{131}$ I, $^{211}$ At 등 의 방사성 핵종의 교질, 미소구 또는 단세포군 항체표지 형태로 직접 종양내 또는 공동이나 체강에 투여하는 치료법이 있다. 류마치스 관절염의 슬관절에 $^{165}$ Dy colloid를 주사하는 $^{166}$ Ho-MAA도 활발히 이용되고 있다. and computed groundwater levels. 본 논문에서는 가파른 산사면에서 산사태의 발생을 예측하기 위한 수문학적 인 지하수 흐름 모델을 개발하였다. 이 모델은 물리적인 개념에 기본하였으며, Lumped-parameter를 이용하였다. 개발된 지하수 흐름 모델은 두 모델을 조합하여 구성되어 있으며, 비포화대 흐름을 위해서는 수정된 abcd 모델을, 포화대 흐름에 대해서는 시간 지체 효과를 고려할 수 있는 선형 저수지 모델을 이용하였다. 지하수 흐름 모델은 토층의 두께, 산사면의 경사각, 포화투수계수, 잠재 증발산 량과 같은 불확실한 상수들과 a, b, c, 그리고 K와 같은 자유모델변수들을 가진다. 자유모델변수들은 유입-유출 자료들로부터 평가할 수 있으며, 이를 위해서 본 논문에서는 Gauss-Newton 방법을 이용한 Bard 알고리즘을 사용하였다. 서울 구로구 시흥동 산사태 발생 지역의 산사면에 대하여 개발된 모델을 적용하여 예제 해석을 수행함으로써, 지하수 흐름 모델이 산사태 발생

  • PDF