• Title/Summary/Keyword: 방사선 해부학

Search Result 99, Processing Time 0.033 seconds

EFFECTS ON THE ENLARGEMENT RATIOS DUE TO CHANGES OF HEAD POSTURE ON LATERAL HEADFILMS (측두 규격방사선사진 촬영시 두부의 위치변화가 확대율에 미치는 영향)

  • Seo, Young-Hun;Choi, Yeong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.1
    • /
    • pp.185-194
    • /
    • 2001
  • This study was designed to evaluate the effects of angulation changes of head posture on the enlargement ratios of a lateral headfilm depending on the vortical or horizontal rotation of the objects. A device was constructed to measure regional changes of enlargement ratios. The device was held within the cephalostat and cephalograms recorded at each measured degrees of the device tilting, vertically and horizontally. The enlargement ratios of the horizontal, vertical, and angular measurements on the films taken at each tilted angulations were obtained and compared with those on the films taken without rotation. In summary, the enlargement ratios of the horizontal linear measurements were decreased during horizontal rotations. The enlargement ratios of vortical measurements of the right side on the film were increased and those of the left side were decreased by the horizontal rotations. Enlargement ratios of horizontal measurements were affected further than those of vertical measurements by the same angular changes of the horizontal rotations. Therefore, a disruption of parallelism between the object's midsagittal plane and the film could result in distortion of the image while vertical rotation around the object's porionic axis would not significantly affect the enlargement ratios on the headfilm.

  • PDF

The evaluation for usefulness of the custom made immobilization device for the anteroperitoneal resection patients with rectal cancer (복 회음부 절제술 환자를 위한 고정용구 제작 및 유용성 평가)

  • Yang Oh Nam;Lee Woo Seok;Hong Tack Kyun;Jo Young Pil;Yun Hwa Ryong;Kim Jung Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.15 no.1
    • /
    • pp.61-65
    • /
    • 2003
  • I. Purpose Patient immobilization is essential factor for successful radiation therapy and major problem is reproducibility to maintain patient position during total radiation therapy period. Purpose of this study is evaluation for usefulness of the custom made immobilization device for the anteroperitoneal resection patients with rectal cancer II. Materials and Methods The object of this study were patients who underwent anteroperitoneal resection and undergo radiation therapy at present with rectal cancer. We made immobilization device for patient individually and analyzed its set up reproducibility, patient position deviation and errors. III. Results There was $5mm{\sim}10mm$ deviation in patient position without individual immobilization device, but we improved the deviation within few mm limitation with individual immobilization device. IV. Conclusion Custom made immobilization device was very helpful for anteroperitoneal resection patient with rectal cancer. We improved the patient position deviation within few mm limitation, shorten the set up time and we could give the comfort to patients.

  • PDF

The Latest Trend of Dynamic MR Defecography for the Chronic Constipation Patient (만성 기능성 변비 환자에서 동적 MR Defecography의 최신동향)

  • Yoon, Seok-Hwan
    • Journal of radiological science and technology
    • /
    • v.27 no.4
    • /
    • pp.17-21
    • /
    • 2004
  • With advancement of the medical imaging technology, the dynamic pelvic MRI (magnetic resonance imaging) has been introduced and used for dynamic MR defecography to improved diagnosis of the patients. At the early stage of its use, it was mostly used to diagnose enterocele or cystocele, then its use was extended to diagnose the organ prolapse and other dysfunctional pelvis organs. There now have been many reports of other diseases such as the functional constipation and others. This paper introduces the pelvis MRI and the dynamic MR defecography and reports the future trend in their clinical applications. Until recently, the studies with pelvic MRI were mostly focused on observing the movement of the pelvis in the supine position. Yang and 26 others reported good result in observing the patients with the pelvic organ prolapse by using the pubococcygeal line as the anatomical index. Using the fast gradient recalled acquisition (fast GRASS), they compared cystocoele, genitourinary prolapse, enterocoele and rectocoele with the control group. Kruyt et al. observed the posterior compartment and reported that MRI was more helpful than the fluoroscopy. Healy et al. applied the dynamic MRI test on the patients with constipation or incontinence as well as the control group without those symptoms. Since then, MRI technology has further advance by Lienemann, who was able to attain the more detailed images using the fast T2 weighted turbo spin echo technology, and others. If its limitation in diagnosing intussusception and the like, since the observation can be made only from the supine position, can be overcome with open MR or others, it is envisages that the method can eventually replace the radiological defecography.

  • PDF

A comparative study of initial lateral cephalometric characteristics: mandibular setback surgery only versus mandibular setback surgery with advancement genioplasty (하악 후퇴술과 전진 이부성형술이 시행된 III급 부정교합자의 초진 시 측모 두부 방사선사진 특성에 관한 연구)

  • Kim, Jae-Sik;Kim, Jung-Il;Kang, Seung-Goo
    • The korean journal of orthodontics
    • /
    • v.38 no.1
    • /
    • pp.41-51
    • /
    • 2008
  • Objective: The aim of this study was to compare the initial lateral cephalometric characteristics in two groups of patients: those that had mandibular setback surgery only and those that had mandibular setback surgery with advancement genioplasty. Methods: The lateral cephalograms of thirty-one patients were studied. Twenty-one Class III patients (group A) had only madibular setback surgery Twelve Class III patients (group B) had mandibular setback surgery with advancement genioplasty. Results: Differences between two groups were found in N-Me, ANS-Me, Occlusal Plane angle, Palatal Plane to U1, Mandibular Plane to L1, Mandibular Plane to L6, SN to U1, Sn-Stms, and Pog' projection. Compared to group A, group B showed more linguoversion and extrusion of upper incisors, more extrusion of lower incisors and lower first molar, and more steepness of the occlusal plane. N-Me, ANS-Me, and Sn-Stms were also longer in group B. But Pog' projection was shorter than group A. Conclusion: We conclude that certain initial lateral cephalometric characteristics may help indicate the inclusion of advancement genioplasty when mandibular setback surgery is planned in skeletal Class III patients.

Development of Medical Image Quality Assessment Tool Based on Chest X-ray (흉부 X-ray 기반 의료영상 품질평가 보조 도구 개발)

  • Gi-Hyeon Nam;Dong-Yeon Yoo;Yang-Gon Kim;Joo-Sung Sun;Jung-Won Lee
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.12 no.6
    • /
    • pp.243-250
    • /
    • 2023
  • Chest X-ray is radiological examination for xeamining the lungs and haert, and is particularly widely used for diagnosing lung disease. Since the quality of these chest X-rays can affect the doctor's diagnosis, the process of evaluating the quality must necessarily go through. This process can involve the subjectivity of radiologists and is manual, so it takes a lot of time and csot. Therefore, in this paper, based on the chest X-ray quality assessment guidelines used in clinical settings, we propose a tool that automates the five quality assessments of artificial shadow, coverage, patient posture, inspiratory level, and permeability. The proposed tool reduces the time and cost required for quality judgment, and can be further utilized in the pre-processing process of selecting high-quality learning data for the development of a learning model for diagnosing chest lesions.

Concurrent Degenerative Cervical and Lumbar Spondylolisthesis (경추 및 요추 퇴행성 척추전위증의 병발성 유병률)

  • Park, Moon Soo;Hwang, Ji-Hyo;Kim, Tae-Hwan;Oh, Jae Keun;Chang, Ho Guen;Kim, Hyung Joon;Park, Kun-Tae;Lim, Jin Kyu;Riew, K. Daniel
    • Journal of Korean Society of Spine Surgery
    • /
    • v.25 no.4
    • /
    • pp.154-159
    • /
    • 2018
  • Study Design: Retrospective radiographic study. Objective: To evaluate the characteristics of concurrent degenerative cervical and lumbar spondylolisthesis. Summary of Literature Review: Concurrent degenerative cervical and lumbar spondylotic diseases have been reported. Given that severe spondylosis can result in spondylolisthesis, one might expect that concurrent spondylolisthesis of the cervical and lumbar spines might also be prevalent. However, the incidence of spondylolistheses in the lumbar and cervical spines might differ due to anatomical differences between the 2 areas. Nonetheless, there is minimal information in the literature concerning the incidence of concurrent cervical and lumbar spondylolisthesis. Material and Methods: We evaluated standing cervical and lumbar lateral radiographs of 2510 patients with spondylosis. Concurrence, age group, gender, and direction of spondylolisthesis were evaluated. Lumbar spondylolisthesis was defined as at least Meyerding grade I and degenerative cervical spondylolisthesis was defined as over 2 mm of displacement on standing lateral radiographs. Results: Lumbar spondylolisthesis was found in 125 patients (5.0%) and cervical spondylolisthesis was found in 193 patients (7.7%). Seventeen patients had both degenerative cervical and lumbar spondylolistheses (0.7%). Lumbar spondylolisthesis is a risk factor for coexisting cervical spondylolisthesis. Lumbar spondylolisthesis was more common in females than males, independent of advancing age. In contrast, degenerative cervical spondylolisthesis was more common in older patients, independent of gender. Anterolisthesis was more common in the lumbar spine. Retrolisthesis was more common in the cervical spine. Conclusions: There was a higher prevalence of degenerative cervical spondylolisthesis in patients with degenerative lumbar spondylolisthesis.

Importance of integrating Bioinformation and Health Informatics for Healthcare

  • 곽연식
    • Proceedings of the Korean Society for Bioinformatics Conference
    • /
    • 2002.06a
    • /
    • pp.89-104
    • /
    • 2002
  • 유전체연구사업단은 국내에서 발병 및 사망빈도가 가장 높은 위암과 간암의 퇴치를 목적으로 국가적 특목전략사업으로 연구를 추진하고 있다. 이와 별도로 보건복지부에서는 22개의 중요 질병별 유전체 연구센터를 전국적으로 추진하고 있다. 따라서, 연구가 성공적으로 진행되면 각 연구소에서 독자적으로 개발하여 제공하는 생명정보의 양은 거의 무한에 이를 것이다. 그러나 생명정보는 환자진료에 도움을 주기 위해서는 궁극적으로 임상정보와 함께 유기적으로 통합되어야 한다. 임상정보와의 통합을 위해서는 의료기관의 진료정보와 연구소의 생명정보가 연계되어 엄밀한 임상실험이 추가적으로 실시되어야 한다. 뿐만 아니라 생명정보학의 발전을 위해서는 연구대상의 임상정보가 공유되어야 한다. 유전체정보를 이용하는 생명정보학(Bioinformatics)은 각 국가마다 전략사업으로 간주하여 막대한 투자가 이루어지는 새로운 분야이다. 현재 선진국에서 개발 사용 중인 시스템의 연간 사용료가 고가이므로 국내 도입은 거의 불가능하거나 또는 매우 비효율적이다. 유전체 또는 생명정보의 임상활용 및 생명정보연구를 위한 임상정보 공유를 위해서는 우선 다음의 사항이 개발되어야 한다. 1) 다음과 같은 개별환자의 정보를 각 의료기관에서 제공 받아 저장 활용한다. - 진찰 및 임상소견, 수술기록, 경과기록, 검사결과 (임상병리, 해부병리, 방사선 등), - 영상정보 (X-ray, CT, MRI, 초음파, 전자현미경, 그래픽 등), - 환자개인기록(병력, 과거력, 가족력, 알러지 등), - 예방접종 기록 2) 각 연구소에서 첨단기술을 이용하여 개발되는 생명정보를 임상에 활용하기 위해서는 유전체연구센타와 병원간에 임상정보와 유전체 분석정보의 공유가 필수적으로 발생하게 됨으로, 유전체 정보와 임상정보의 통합은 미래 의료환경에 필수기능이 될 것이다. 3) 각 생명공학 연구소에서 사용하는 첨단 분석 장비와 생명공학 정보시스템의 자동 연계가 필요하다. 현재 국내에는 전국적인 초고속정보망이 가동되어 웹을 기반으로 하는 생명정보의 공유는 기술적으로 문제가 될 수 없으나 임상정보의 유전체연구에 그리고 유전체연구정보의 임상활용은 다양한 문제를 내포하고 있다. 이에 영상을 포함한 환자정보의 유전체연구센터와 병원정보시스템과의 효율적인 연계통합 운영을 위해 국내에서는 초기 도입단계에 있는 국제적인 보건의료정보의 표준인 Health Level 7 (textural information 공유), DICOM (image 및 wave 공유), 관련 ISO표준, WHO의 ICD9/10 (질병분류), LOINC (검사 및 관련용어), SNOMED International (의학용어) 등을 활용하여야 한다.

  • PDF

A cephalometric study on the relationship between mandibular opening movement and morphology of craniofacial skeleton (아동의 개구운동과 두개안면골격형태의 상관성 -측모두부방사선 계측법적 연구-)

  • Kim, Min-Shil;Chung, Kyu-Rhim
    • The korean journal of orthodontics
    • /
    • v.30 no.3 s.80
    • /
    • pp.297-306
    • /
    • 2000
  • Lateral cephalometric X-ray films in maximal intercuspation and maximal opening of 68 children were taken and analyzed to examine the pattern of condylar movement and to study the relationship between opening movement and morphologic factors of craniofacial skeleton. The results were as follows : 1. The mean value of maximal opening capacity was 47.1mm, condylar moving distance was 18.1mm, horizontal condyle movement was 17.5mm, vertical condyle movement was 3.8mm and condylar moving angle was $13.1^{\circ}$. 2. The maximal opening capacity had positive relationship with the length of anterior cranial base, mandible and maxillary complex and with posterior facial height and had negative relationship with articular angle, sagittal jaw relationship. 3. Vertical condyle movement and condylar moving angle had positive relationship with articular angle and had negative relationship with gonial angle. 4. Horizontal condyle movement and condylar moving distance had positive relationship with the length of maxillary complex.

  • PDF

An Evaluation Method of X-ray Imaging System Resolution for Non-Engineers (비공학도를 위한 X-ray 영상촬영 시스템 해상력 평가 방법)

  • Woo, Jung-Eun;Lee, Yong-Geum;Bae, Seok-Hwan;Kim, Yong-Gwon
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.309-314
    • /
    • 2012
  • Nowadays, digital Radiography (DR) systems are widely used in clinical sites and substitute the analog-film x-ray imaging systems. The resolution of DR images depends on several factors such as characteristic contrast and motion of the object, the focal spot size and the quality of x-ray beam, x-ray scattering, the performance of the DR detector (x-ray conversion efficiency, the intrinsic resolution). The DR detector is composed of an x-ray capturing element, a coupling element and a collecting element, which systematically affect the system resolution. Generally speaking, the resolution of a medical imaging system is the discrimination ability of anatomical structures. Modulation transfer function (MTF) is widely used for the quantification of the resolution performance for an imaging system. MTF is defined as the frequency response of the imaging system to the input of a point spread function and can be obtained by doing Fourier transform of a line spread function, which is extracted from a test image. In clinic, radiologic technologists, who are in charge of system maintenance and quality control, have to evaluate or make routine check on their imaging system. However, it is not an easy task for the radiologic technologists to measure MTF accurately due to lack of their engineering and mathematical backgrounds. The objective of this study is to develop and provide for radiologic technologists a medical system imaging evaluation tool, so that they can measure and quantify system performance easily.

Study on 3D Printer Production of Auxiliary Device for Upper Limb for Medical Imaging Test (의료영상 검사를 위한 상지 보조기구의 3D 프린터 제작 연구)

  • Kim, Hyeong-Gyun;Yoon, Jae-Ho;Choi, Seong-Dae
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.389-394
    • /
    • 2015
  • There is a progressive development in the medical imaging technology, especially of descriptive capability for anatomical structure of human body thanks to advancement of information technology and medical devices. But however maintenance of correct posture is essential for the medical imaging checkup on the shoulder joint requiring rotation of the upper limb due to the complexity of human body. In the cases of MRI examination, long duration and fixed posture are critical, as failure to comply with them leads to minimal possibility of reproducibility only with the efforts of the examiner and will of the patient. Thus, this study aimed to develop an auxiliary device that enables rotation of the upper limb as well as fixing it at quantitative angles for medical imaging examination capable of providing diagnostic values. An auxiliary device has been developed based on the results of precedent studies, by designing a 3D model with the CATIA software, an engineering application, and producing it with the 3D printer. The printer is Objet350 Connex from Stratasys, and acrylonitrile- butadiene-styrene(ABS) is used as the material of the device. Dimensions are $120{\times}150{\times}190mm$, with the inner diameter of the handle being 125.9 mm. The auxiliary device has 4 components including the body (outside), handle (inside), fixture terminal and the connection part. The body and handle have the gap of 2.1 mm for smooth rotation, while the 360 degree of scales have been etched on the handle so that the angle required for observation may be recorded per patient for traceability and dual examination.