• Title/Summary/Keyword: 방사선 차폐효과

Search Result 148, Processing Time 0.028 seconds

A Study on Dose Distribution around Fletcher-Suit Colpostat Containing Cs-137 Source by a Computer (컴퓨터 의한 Fletcher-Suit Colpostat 주변의 Cs-137의 선량분포에 관한 연구)

  • Kang Wee-Saing
    • Radiation Oncology Journal
    • /
    • v.7 no.2
    • /
    • pp.305-311
    • /
    • 1989
  • Fletcher-Suit colpostat has an internal structure to reduce dose to bladder and rectum. Some programs were developed to calculate dose at any point in water in three dimension around the colpostat containing Cs-137 tube, to find the shielding effect to dose by the internal structure, and to draw isodose curves and iso-shielding effect curves. Computer was an IBM compatible AT with EGA card and language was MS-Basic V6.0, Material, shape and geometry of the strucure, tube and colpostat were considered in algorithm for calculation of dose. Dose rates per unit mg. Ra. eq. in water calculated by a program were stored in auxiliary memory devices and retrieved in another programs. Isodose curves on medial side shrinked. Dose distribution was not symmetric about a transverse axis bisecting the colpostat. Reduction of dose was more excessive on top side than on bottom. Iso-shielding effect curve showed that the shielding effect was higher on top side than on bottom, and that there was shielding effect over almost all area of medial side. Such results were related to both shifted position of tube in the colpostat and asymmetric distribution of active source in the tube. Maximum of shielding effect was $49\%$ on top side and $44\%$ on bottom side. The direction of iso-shielding effect curve was generally radial from the center of active source. In treatment planning using Fletcher-Suit colpostat, the internal structure should be considered to find precise doses to bladder and rectum, etc.

  • PDF

The Design of unevenly leaf width distributed Multileaf Collimator (불균일 폭 분포를 갖는 Multileaf Collimator 설계에 관한 연구)

  • 이병용;장혜숙;조병철
    • Progress in Medical Physics
    • /
    • v.5 no.2
    • /
    • pp.45-48
    • /
    • 1994
  • We have studied about leaf-width distribution of Multileaf Collimator(MLC). We have analyzed 1169 treatment fields from 303 patients who have treated by radiation therapy. From this analysis, we can design an unevenly leaf-width distributed MLC, by placing the smaller leaf widths for more frequent blocking region and the larger for less. The average width of total leaves is 0.8 cm, but the effective block width is 0.5-0.6 cm for frequently blocking region(3-6 cm from the field center).

  • PDF

The Study for Radio Protection According to a Possible Danger of Exposure During low energy X-ray Examination (저 에너지 방사선 검사 시 노출 위험성에 따른 피폭선량 방어연구)

  • Lim, Cheong-Hwan;Jeong, Cheon-Soo
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2011.05a
    • /
    • pp.187-188
    • /
    • 2011
  • 저 에너지 방사선검사 시 부득이하게 방사선 노출을 받게 되는 방사선 작업종사자나 환자의 보호자가 위치와 거리에 따른 방사선 피폭 선량의 감소 방안을 알아보고자 한다. Ion chamber mode 2026c, Reader기 20X6-1800을 사용하여 구강내 검사와 구강외 검사의 각각 검사실과 조정실에서의 관전압의 변화, 관전류와 조사시간의 변화, 조사방향의 변화에 따라 선량을 측정하였다. 그 결과 검사실 안에서는 최고선량이 평균 $702.8{\mu}R$으로 측정 되었으며, 조정실 안에서 측정하였을 경우 $20{\mu}R$이하의 낮은 선량을 보였으며, 후방검사보다 측방검사가 낮은 선량으로 나타났다. 방사선검사 시 위치와 거리에 따른 조사선량을 비교 분석하여, 적절한 거리 확보와 조사되는 중심방사선을 기준으로 측방($90{\sim}135^{\circ}$)에 위치함으로써 방사선 방어에 도움을 줄 것이며, 차폐문을 이용하여 방사선 피폭으로부터 감소 효과를 볼 수 있을 것이다.

  • PDF

Shielding Design Optimization of the HANARO Cold Neutron Triple-Axis Spectrometer and Radiation Dose Measurement (냉중성자 삼축분광장치의 차폐능 최적화 설계 및 선량 측정)

  • Ryu, Ji Myung;Hong, Kwang Pyo;Park, J.M. Sungil;Choi, Young Hyeon;Lee, Kye Hong
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.1
    • /
    • pp.21-29
    • /
    • 2014
  • A new cold neutron triple-axis spectrometer (Cold-TAS) was recently constructed at the 30 MWth research reactor, HANARO. The spectrometer, which is composed of neutron optical components and radiation shield, required a redesign of the segmented monochromator shield due to the lack of adequate support of its weight. To shed some weight, lowering the height of the segmented shield was suggested while adding more radiation shield to the top cover of the monochromator chamber. To investigate the radiological effect of such change, we performed MCNPX simulations of a few different configurations of the Cold-TAS monochromator shield and obtained neutron and photon intensities at 5 reference points just outside the shield. Reducing the 35% of the height of the segmented shield and locating lead 10 cm from the bottom of the top cover made of polyethylene was shown to perform just as well as the original configuration as radiation shield excepting gamma flux at two points. Using gamma map by MCNPX, it was checked that is distribution of gamma. Increased flux had direction to the top and it had longer distance from top of segmented shield. However, because of reducing the 35% of the height, height of dissipated gamma was lower than original geometry. Reducing the 35% of the height of the segmented shield and locating lead 10cm from the bottom of the top cover was selected. After changing geometry, radiation dose was measured by TLD for confirming tester's safety at any condition. Neutron(0.21 ${\mu}Svhr^{-1}$) and gamma(3.69 ${\mu}Svhr^{-1}$) radiation dose were satisfied standard(6.25 ${\mu}Svhr^{-1}$).

The Enhancement of Skin Sparing by Tray Materials for High Energy Photon Beam (고에너지 광자선치료에서 고정판 흡수물질을 이용한 피부보호효과의 향상)

  • Chu, Sung-Sil;Lee, Chang-Geol;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.11 no.2
    • /
    • pp.449-454
    • /
    • 1993
  • The skin sparing effect associated with high energy x-ray or gamma ray beams may be reduce or lost under certain conditions of treatment. Current trends in using large fields. Shield carrying trays, compensating filters, and isocentric methods of treatment have posed problems of increased skin dose which sometimes become a limiting factor in giving adquate tumor doses. We used the shallow ion chamber to measure the phantom surface dose and the physical treatment variables for Co-60 gamma ray, 4MV and 10 MV x-ray beam. The dependence of percent surface dose on field sizes, atomic number of the shielding tray materials and its distance from the surface for 4, 10MV x-rays and Co-60 gamma ray is qualitatively similar. The use of 2 mm thick tin filter is recommended for situations where a low atomic number tray is introduced into the beam at distances less than 15 cm from the surface and with the large field sized for 4 MV x-ray beam. In case of Co-60 gamma ray, the lead glass tray is suitable for enhancement of skin sparing. Also, the filter distance should be as large as possible to achieve substantial skin sparing.

  • PDF

Evaluation of the Apron Effectiveness during Handling Radiopharmaceuticals in PET/CT Work Environment (PET/CT 업무 환경에서 선원 취급 시 Apron의 실효성 평가)

  • Cho, Yong-In;Ye, Soo-Young;Kim, Jung-Hoon
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.237-244
    • /
    • 2015
  • Health professionals in nuclear medicine were known that they get high radiation exposure. To reduce radiation exposure, using shielding materials is needed. In this study, we analyzed the shielding effect about apron during 18F-FDG treatment by using simulation based on Monte Carlo techniques and actual measurement. As a result, absorbed dose distribution of organ varies with handling position of the source. Dose reduction ratio by lead thickness of apron tended to decease, when handling position of the source come close to organ and away from radiation source for simulation. In the case of actual measurement with the dosimetry device, It showed that mean spatial dose distribution was different due to characteristics of dosimetry device. However, spatial dose rate was exponentially reduced according to distance with increasing lead content.

The Usability Evaluation of the Usefulness of Bismuth Shields in PET/CT Examination (PET/CT 검사에서 비스무스(bismuth) 차폐체의 적용에 따른 유용성 평가)

  • Park, Hoon-Hee;Lee, Juyoung;Kim, Ji-Hyeon;Nam, Kun-Sik;Lyu, Kwang-Yeul;Lee, Tae Soo
    • Journal of radiological science and technology
    • /
    • v.37 no.1
    • /
    • pp.49-56
    • /
    • 2014
  • Recently with CT developed, various studies for reduction of exposure dose is underway. Study of bismuth shields in these studies is actively underway, and has already been applied in the clinical. However, the application of the PET/CT examination was not activated. Therefore, through this study, depending on the application of bismuth shields in the PET/CT examination, we identify the quality of the image and the impact on the Standard Uptake Value (SUV). In this study, to apply to the shielding of the breast, by using the bismuth shields that contains 0.06 mm Pb ingredients, was applied to the PET/CT GEMINI TF 64 (Philips Healthcare, Cleveland, USA). Phantom experiments using the NEMA IEC Body Phantom, images were acquired according to the presence or absence of bismuth shields apply. Also, When applying, images were obtained by varying the spacing 0, 1, 2 cm each image set to the interest range in the depth of the phantom by using EBW-NM ver.1.0. When image of the PET Emission acquires, the SUV was in increased depending on the use of bismuth shields, difference in the depth to the surface from deep in the phantom increasingly SUV increased (P<0.005). Also, when using shields, as the more gab decreased, SUV is more increased (P<0.005). Through this study, PET/CT examination by using of bismuth shields which is used as purpose of reduction dose. When using shields, the difference of SUV resulting from the application of bismuth shields exist and that difference when gab is decrease and surface is wider. Therefore, setting spacing of shield should be considered, if considering the reduction of the variation of SUV and image quality, disease of deep organs should be a priority rather than superficial organ disease. Use of bismuth shielding factor considering the standard clinical examination, decrease unnecessary exposure can be expected to be considered.

A Study on Dose Distribution around Fletcher-Suit Colpostat Containing $^{137}Cs$ Source ($^{137}Cs$ 선원을 내포한 Fletcher-Suit Colpostat 주위의 선량분포에 관한 연구)

  • Kang Wee-Saing
    • Radiation Oncology Journal
    • /
    • v.6 no.2
    • /
    • pp.263-268
    • /
    • 1988
  • This paper presents dose distributions in water around Fletcher-Suit colpostat containing $^{137}Cs$ tube, and shielding effect of Internal lead shield. Using ready packed film, author measured dose distribution in water around the colpostat containing cesium source. Nine sheets of films on one side of the colpostat are packed with acryl frames cut out so as to fill water, and irradiated in water by cesium source in the colpostat. Dose distributions on transverse plane and upper plane 0.5cm from upper surface of the colpostat were measured. Shielding effect was greater in upper medial direction than in lower medial direction. And that was the greatest around $30^{\circ}$ from the axis of the colpostat on upper side and around $50^{\circ}$on lower side. In the region 7cm from the center of the colpostat, shielding efficiency was 0.23 to 0.35 on the lower $50^{\circ}$ and 0.26 to 0.42 on the upper $30^{\circ}$, and decreased with increase of distance.

  • PDF

한국원자력연구소 방사선방어기술 개발 및 연구 현황

  • Ha, Jeong-U
    • Journal of Radiation Protection and Research
    • /
    • v.15 no.1
    • /
    • pp.9-13
    • /
    • 1990
  • 1959년 한국원자력연구소가 창립됨과 동시에 &Health Physics&, 즉 보건물리라고 하는 명칭과 조직이 탄생되어, 방사선안전관리의 실무와 보건물리의 연구가 시작되었다. 최초 10년간은 선진제국의 보건물리분야의 연구와 기술을 추적하여 우리나라의 방사선안전관리 기술의 기초를 다지는 시기로서 개인방사선모니터링기술, 환경방사선(능) 모니터링기술 및 방사선방어용계측기기의 교정기술 개발에 중점을 두고 연구개발이 추진되었으며, TRIGA Mark-II 연구용원자로의 가동에 따라 원자로 생체차폐체의 건전성 검증에 관한 유익한 방사선량 측정자료도 얻게 되었다. 즉 이 기간은 방사선안전관리의 체제정비 및 기초기술 확립에 노력한 기간이었다. 1970년대는 원자력 연구개발에 대한 기본방향과 정책의 변경등으로 보건물리 연구조직은 방사선안전관리, 환경연구 그리고 방사화학분야로 분산되었으며, 그로인하여 연구개발활동은 거의 정체되어 겨우 방사선안전관리 실무만이 그 명맥을 유지하였다. 그 결과 우리나라 방사선안전관리 및 그와 관련된 연구개발의 기반이 흔들리게 되었으나, 그러한 환경하에서도 방사선량측정평가기술, 방사선차폐설계기술 및 원자로사고시 피폭선량평가기술의 선진화에 필요한 지식을 얻었으며, 방사선 안전관리에 유익한 실무경험도 축적하게 되었다. 1980년대는 통합된 원자력 연구개발체제의 구축으로 방사선작업종사자 및 일반공중의 피폭저감화 기술개발에 필요한 각종 최신기술을 도입하였고, 관리업무에 있어서도 측정의 정확도와 신뢰성향상 및 새로운 관리기술의 개발에 많은 노력을 한 결과, 유익한성과를 얻게된 기간이다. 특히, 이 기간은 방사선안전관리기술의 선진화를 위한 지식이 축적되어 90년대의 방사선안전관리기술자립화를 위한 전환기로서, 이와같이 축적된 기술은 원자력의 평화적 이용에 크게 기여할 것으로 기대된다.서 dithiothreitol를 투여한 군에서는 우라늄단독투여군에 비해 cretinine의 배설이 상당히 증가하였다(P<0.05). 6. 우라늄오염에 의한 신장의 소견에 있어 우라늄단독투여군은 근위곡세뇨관상피의 공포화 및 종창, microvilli와 brush border의 손실, 세뇨관 상피의 괴사가 관찰되었으며, 간장의 충혈, 중심성 괴사 및 모세관 확장증도 관찰되었다. 그리고 sodium bicarbonate와 생리적 식염수를 병행투여한 군과 우라늄을 투여하고 30분이 지나서 dithiothreitol를 투여한 군에서는 우라늄 단독투여군에 비해 높은 방호효과가 관찰되었으나 다른 실험군에서는 큰 효과가 없는 것으로 나타났다. 결론적으로 우라늄의 체내오염시에는 sodium bicarbonate와 생리적 식염수를 가능한 빨리 병행투여하거나 dithiothreitol을 체내오염후 30분이 지나서 투여하는 방법이 우라늄오염에 대한 제염에 매우 유효할 것으로 생각되며, 특히 우라늄에 의한 인체장해를 유의하게 경감시켜줄 것으로 사료되었다.내의 어떤 부위와도 관계가 되는 것으로 간주되는데 이것이 $(^3H)$ QNB가 $(^3H)$ NMS보다 높은 최대 결합능력 $(B_{max})$을 나타낼 이유이다. (b) 두 종류의 다른 제제에서 우리는 같은 양상의 결과를 관찰하었기에 결점이 많은 homogenates 제제보다는 intact cell aggregates 제제를 수용체 연구에 대한 새로운 실험모형(experiment model)으로 사용할 수 있는 가능성을 제시하고자 한다.$가 38.8%로 가장 많고, 그 다음이 ${\ulcorner}$l9세(歲)이후${\lrcorner}$가 25.2%로서 전체

  • PDF

Effect of Reducing Scattering Radiation Exposure of Medical Staffs When Additional Shielding is Used in Interventional Radiology (중재적 방사선시술에서 부가 차폐체 사용 시 종사자의 산란선 피폭 감소효과)

  • Kim, Min-Jun;Baek, Kang-Nam;Kim, Sungchul
    • Journal of radiological science and technology
    • /
    • v.44 no.6
    • /
    • pp.629-633
    • /
    • 2021
  • This article is designed to look into the radiation exposure dose to each body part and the shielding effect for workers using an additional shielding to reduce their radiation exposured by scattering radiation which is generated in a space between the operating table and lead curtain during interventional radiology(IR) procedures. After placing a human phantom on the table of SIEMENS' angiography machine, the following measurements were taken, depending on the presence of an additional shield of lead equivalent of 0.25 mmPb, manufactured for this purpose: dose to gonad, dose to an area where the personal dosimeter is placed, and dose to an area of eye lens is located. An ion chamber(chamber volume 1,800 cc) was utilized to measure scattering radiation. The two imaging tests were carried out as follows: fluoroscopy of the abdomen (66 kV, 100 mA, 60 seconds) and of the head (70 kV, 65 mA, 60 seconds); and digital subtraction angiography(DSA) of the abdomen (67 kV, 264 mA, 20 seconds) and of the head (79 kV, 300 mA, 20 seconds). In all the experiments, the shielding efficiency of the gonad position was the largest at 59.8%. In case an additional shielding was used as protection against scattering radiation that came through the operating table and the lead curtain during an IR, the radiation shielding efficiency was estimated to be up to 59.8%, leading to a conclusion that its presence may effectively reduce the radiation exposure dose of medical staffs.