• Title/Summary/Keyword: 방사선 조사영역

Search Result 298, Processing Time 0.042 seconds

Dosimetric evaluation of using in-house BoS Frame Fixation Tool for the Head and Neck Cancer Patient (두경부암 환자의 양성자 치료 시 사용하는 자체 제작한 BoS Frame 고정장치의 선량학적 유용성 평가)

  • Kim, kwang suk;Jo, kwang hyun;Choi, byeon ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.1
    • /
    • pp.35-46
    • /
    • 2016
  • Purpose : BoS(Base of Skull) Frame, the fixation tool which is used for the proton of brain cancer increases the lateral penumbra by increasing the airgap (the distance between patient and beam jet), due to the collision of the beam of the posterior oblique direction. Thus, we manufactured the fixation tool per se for improving the limits of BoS frame, and we'd like to evaluate the utility of the manufactured fixation tool throughout this study. Materials and Methods : We've selected the 3 patients of brain cancer who have received the proton therapy from our hospital, and also selected the 6 beam angles; for this, we've selected the beam angle of the posterior oblique direction. We' ve measured the planned BoS frame and the distance of Snout for each beam which are planned for the treatment of the patient using the BoS frame. After this, we've proceeded with the set-up that is above the location which was recommended by the manufacturer of the BoS frame, at the same beam angle of the same patient, by using our in-house Bos frame fixation tool. The set-up was above 21 cm toward the superior direction, compared to the situation when the BoS frame was only used with the basic couch. After that, we've stacked the snout to the BoS frame as much as possible, and measured the distance of snout. We've also measured the airgap, based on the gap of that snout distance; and we've proceeded the normalization based on each dose (100% of each dose), after that, we've conducted the comparative analysis of lateral penumbra. Moreover, we've established the treatment plan according to the changed airgap which has been transformed to the Raystation 5.0 proton therapy planning system, and we've conducted the comparative analysis of DVH(Dose Volume Histogram). Results : When comparing the result before using the in-house Bos frame fixation tool which was manufactured for each beam angle with the result after using the fixation tool, we could figure out that airgap than when not used in accordance with the use of the in-house Bos frame fixation tool was reduced by 5.4 cm ~ 15.4 cm, respectively angle. The reduced snout distance means the airgap. Lateral Penumbra could reduce left, right, 0.1 cm ~ 0.4 cm by an angle in accordance with decreasing the airgap while using each beam angle in-house Bos frame fixation tool. Due to the reduced lateral penumbra, Lt.eyeball, Lt.lens, Lt. hippocampus, Lt. cochlea, Rt. eyeball, Rt. lens, Rt. cochlea, Rt. hippocampus, stem that can be seen that the dose is decreased by 0 CGE ~ 4.4 CGE. Conclusion : It was possible to reduced the airgap by using our in-house Bos frame fixation tool for the proton therapy; as a result, it was possible to figure out that the lateral penumbra reduced. Moreover, it was also possible to check through the comparative analysis of the treatment plan that when we reduce the lateral penumbra, the reduction of the unnecessary irradiation for the normal tissues. Therefore, Using the posterior oblique the Brain cancer proton therapy should be preceded by decreasing the airgap, by using our in-house Bos frame fixation tool; also, the continuous efforts for reducing the airgap as much as possible for the proton therapy of other area will be necessary as well.

  • PDF

The Effects of the Food Labeling Home Economics Instruction applying ARCS Motivation Teaching Strategy on Middle School Students' Learning Motivation, Recognition and Use of Food Labels (ARCS 동기유발 전략을 적용한 가정과 식품표시 수업이 중학생의 학습동기와 식품표시에 대한 인식 및 활용도에 미치는 효과)

  • Yeo, Soo-Kyoung;Chae, Jung-Hyun
    • Journal of Korean Home Economics Education Association
    • /
    • v.23 no.1
    • /
    • pp.113-141
    • /
    • 2011
  • The purpose of this study was to examine the effects of home economics instruction in food labeling using a motivational(ARCS-Attention, Relevance, Confidence, and Satisfaction) strategy to increase middle school students' learning motivation, recognition and use of food labels. To achieve this purpose, teaching-learning plans of food label instruction using a motivation(ARCS) strategy were developed over four class periods using a pretest-posttest experimental design. The experiment was conducted across two groups as follows: 4 experimental groups that received the motivation(ARCS) strategy instruction, and 3 comparative groups that received lecture type instruction. The pretest-posttest scores of the experimental and comparative groups were compared. The 203 data of questionnaires for the experiment were analyzed and evaluated by Analysis of Covariance(ANCOVA) using SPSS Win 12,0. The results of this study were as follows: First, teaching-learning plans, learning materials, and teacher reference materials for the home economics food label instruction that applied the motivation(ARCS) strategy were developed in five subject areas: nutrition labels, food additives, genetically modified food, irradiated food, and food quality verification labels. Second, students' learning motivation of the two groups showed statistically meaningful differences. Home economics instruction using a motivation(ARCS) strategy was more effective in increasing students' learning motivation than lecture type instruction. Third, as a result of ANCOVA which regulated the recognition of food labels in the pre-experimental design, the recognition of food labels in the post-experimental design showed the meaningful differences depending on the instruction style(motivation strategy and lecture type instruction). In addition, comprehensibility, practical use and educational necessity of food label details showed statistically meaningful differences. Home economics instruction using motivation(ARCS) strategy was more effective than lecture type instruction in improving students' recognition of food labeling. Fourth, as a result of ANCOVA which regulated the use of food labels in the pre-experimental stage, the use of food labels in the post-experimental stage showed meaningful differences between experimental and comparative groups depending on the instruction style. Therefore, home economics instruction in food labeling using motivation(ARCS) strategy was more effective than lecture type instruction in increasing students' use of food labels.

  • PDF

Evaluation of static fracture resistances and patterns of pulpless tooth restored with poly-ether-ketone-ketone (PEKK) post (Poly-ether-ketone-ketone (PEKK) 포스트로 수복한 근관 치료 치아의 정적 파절 저항성 및 파절 형태에 관한 평가)

  • Park, Ha Eun;Lee, Cheol Won;Lee, Won Sup;Yang, Sung Eun;Lee, Su Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.2
    • /
    • pp.127-133
    • /
    • 2019
  • Purpose: The purpose of present study was to investigate fracture strength and mode of failure of endodontically treated teeth restored with metal cast post-core system, prefabricated fiber post system, and newly introduced polyetherketoneketone (PEKK) post-core system. Materials and methods: A total of 21 mandibular premolar were randomly grouped into 3 groups of 7 each according to the post material. Group A was for metal cast post core; Group B for prefabricated glass fiber post and resin core; and Group C for milled PEKK post cores. All specimens were restored with metal crown. The fracture strength of each specimen was measured by applying a static load of 135-degree to the tooth at 2 mm/min crosshead speed using a universal testing machine. After the fracture strength measurement, the mode of failure was observed. The results were analyzed using Kruscal-Wallis test and post hoc Mann-Whitney U test at confidence interval ${\alpha}=.05$. Results: Fracture resistance of PEKK post core was lower than those of cast metal post and fiber reinforced post with composite resin core. In the aspect of fracture mode most of the root fracture occurred in the metal post core, whereas the post detachment occurred mainly in the fiber reinforced post. In the case of PEKK post core, teeth and post were fractured together. Conclusion: It is necessary to select appropriate materials of post for extensively damaged teeth restoration and clinical application of the PEKK post seems to require more research on improvement of strength.

The efficacy and safety of transcatheter closure of atrial septal defect with Amplatzer septal occluder in young children less than 3 years of age (3세 미만 심방중격결손 소아에서 Amplatzer 기구 폐쇄술의 안전성 및 효용성)

  • Lee, Soo Hyun;Choi, Deok Young;Kim, Nam Kyun;Choi, Jae Young;Sul, Jun Hee
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.4
    • /
    • pp.494-498
    • /
    • 2009
  • Purpose : Applicability of transcatheter closure of atrial septal defect (ASD) has been expanded by accumulation of clinical experiences and evolutions of the device. This study was performed to evaluate the safety and efficacy of transcatheter closure of ASD with Amplatzer septal occluder (ASO) in young children less than 3 years of age. Methods : From May 2003 to December 2005, 295 patients underwent transcatheter closure of ASD with ASO in the Severance Cardiovascular Hospital, Yonsei University Health System. Among them, 51 patients less than 3 years of age were enrolled in this study. We investigated procedural success rate, rate of residual shunt, frequency of complications, procedure/fluoroscopy time, and need of modified techniques for device implantation. Results : The median age was 2.1 years and median body weight was 12 kg. Implantation of device was successful in 50 patients (98%). Seven patients (15%) showed a small residual shunt 1 day after the procedure, but complete occlusion had been documented at 6 month follow-up in all patients (100%). The pulmonary to systemic flow ratio (Qp/Qs), peak systolic pulmonary artery pressure, and peak systolic right ventricular pressure had decreased significantly after closure of ASD. There were 2 complications including device embolization (1, 2%) and temporary groin hematoma (1, 2%). Conclusion : Transcatheter closure of ASD with ASO can be performed with satisfactory results and acceptable risk even in young children less than 3 years of age. We could suggest that even in very young children with ASD, there is no need to wait until they grow to a sufficient size for the transcatheter closure.

Development of Video Image-Guided Setup (VIGS) System for Tomotherapy: Preliminary Study (단층치료용 비디오 영상기반 셋업 장치의 개발: 예비연구)

  • Kim, Jin Sung;Ju, Sang Gyu;Hong, Chae Seon;Jeong, Jaewon;Son, Kihong;Shin, Jung Suk;Shin, Eunheak;Ahn, Sung Hwan;Han, Youngyih;Choi, Doo Ho
    • Progress in Medical Physics
    • /
    • v.24 no.2
    • /
    • pp.85-91
    • /
    • 2013
  • At present, megavoltage computed tomography (MVCT) is the only method used to correct the position of tomotherapy patients. MVCT produces extra radiation, in addition to the radiation used for treatment, and repositioning also takes up much of the total treatment time. To address these issues, we suggest the use of a video image-guided setup (VIGS) system for correcting the position of tomotherapy patients. We developed an in-house program to correct the exact position of patients using two orthogonal images obtained from two video cameras installed at $90^{\circ}$ and fastened inside the tomotherapy gantry. The system is programmed to make automatic registration possible with the use of edge detection of the user-defined region of interest (ROI). A head-and-neck patient is then simulated using a humanoid phantom. After taking the computed tomography (CT) image, tomotherapy planning is performed. To mimic a clinical treatment course, we used an immobilization device to position the phantom on the tomotherapy couch and, using MVCT, corrected its position to match the one captured when the treatment was planned. Video images of the corrected position were used as reference images for the VIGS system. First, the position was repeatedly corrected 10 times using MVCT, and based on the saved reference video image, the patient position was then corrected 10 times using the VIGS method. Thereafter, the results of the two correction methods were compared. The results demonstrated that patient positioning using a video-imaging method ($41.7{\pm}11.2$ seconds) significantly reduces the overall time of the MVCT method ($420{\pm}6$ seconds) (p<0.05). However, there was no meaningful difference in accuracy between the two methods (x=0.11 mm, y=0.27 mm, z=0.58 mm, p>0.05). Because VIGS provides a more accurate result and reduces the required time, compared with the MVCT method, it is expected to manage the overall tomotherapy treatment process more efficiently.

Manufacturing Techniques of Bronze Seated Bodhisattva Statue of Goseongsa Temple in Gangjin (강진 고성사 청동보살좌상의 제작기술 연구)

  • LEE Seungchan;BAE Gowoon;CHUNG Kwangyong
    • Korean Journal of Heritage: History & Science
    • /
    • v.57 no.1
    • /
    • pp.146-159
    • /
    • 2024
  • In this study, a study on the production technology of the Buddha statue and the production of raw material origin was conducted through scientific analysis on the Bronze seated Bodhisattva Statue of Goseongsa Temple, a treasure. As a result of microstructure analysis through a metal microscope, it was confirmed that the microstructure of the Bronze seated Bodhisattva Statue of Goseongsa Temple was a process-type dendritic structure, and the casting structure of bronze was well represented, so it was manufactured through casting. Subsequently, as a result of analyzing the alloy composition ratio through SEM-EDS, it was identified as a ternary alloy with 81.26 wt% of copper (Cu) and 16.42 wt% of tin (Sn) and 1.72 wt% of lead (Pb). The results of the analysis of lead isotope ratios using a thermal ionization mass spectrometer (TIMS) were substituted into the distribution of lead isotope ratios on the Korean Peninsula, it was shown in corresponding to Jeolla-do and Chungcheong-do regions and North and South Gyeongsang Province. This suggests that the raw materials used in their production were likely sourced from the mines around Goseong Temple in Gangjin. Despite the fact that the statue is a medium and large Buddha with a total height of 51 centimeters, 1.72 wt% of lead (Pb) was found as a result of alloy composition ratio analysis, which showed a similar composition to the lead content ratio of small bronze and gilt-bronze Buddha statues. Therefore, we compared and analyzed the results of the analysis of the composition ratio of the alloys of bronze and gilt bronze statues, which has been scientifically analyzed with a compositional age similar to that of the Bronze seated Bodhisattva Statue of Goseongsa Temple. Comparison results, Various factors, such as the size of the Buddha statue as well as its stylistic characteristics and the age of composition, may exist in determining the alloy composition ratio of the bronze and gilt bronze Buddha statues, and it was confirmed that the alloy composition ratio or casting technology was properly adjusted when the Buddha statue was created. In other words, it is judged that a more comprehensive system of Buddha statue production technology should be investigated by conducting archaeological and art history studies on stylistic characteristics and age of composition, as well as scientific analysis results such as observation of internal structure, microstructure observation, and analysis of alloy composition ratio using radiation transmission irradiation.

The causative organisms of pediatric empyema in Korea (소아 농흉 원인균에 대한 다기관 연구(1999. 9-2004. 8))

  • Yum, Hye-yung;Kim, Woo Kyung;Kim, Jin Tak;Kim, Hyun Hee;Rha, Yeong Ho;Park, Yong Min;Sohn, Myung Hyun;Ahn, Kang Mo;Lee, Soo Young;Hong, Su Jong;Lee, Hae Ran
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.1
    • /
    • pp.33-39
    • /
    • 2007
  • Purpose : In spite of medical advances, empyema is a serious complication of pneumonia in children. Vaccination practices and antibiotic prescribing practices promote the change of clinical manifestations of empyema and causative organisms. So we made a nationwide clinical observation of 122 cases of empyema in children from 32 hospitals during the 5 year period from September 1999 to August 2004. Methods : Demographic data, and clinical information on the course and management of empyema patients were collected retrospectively from medical records in secondary and tertiary hospitals in Korea. Results : One hundred twenty two patients were enrolled from 35 hospitals. The most frequent age group was 1-3 years, accounting for 48 percent of all cases. The male to female sex ratio was 1.2:1. The main symptoms were cough, fever, respiratory difficulty, lethargy and chest pain in order of frequency. Hematologic findings on admission revealed decreased hemoglobin levels ($10.4{\pm}1.6g/dL$) and increased leukocyte counts ($16,234.3{\pm}10,601.8/{\mu}L$). Pleural fluid obtained from patients showed high leukocyte counts ($30,365.8{\pm}64,073.0/{\mu}L$), high protein levels ($522.3{\pm}1582.3g/dL$), and low glucose levels ($88.1{\pm}523.5mg/dL$). Findings from pleural fluid cultures were positive in 80 cases(65.6 percent). The most common causative agent was Streptococcus pneumoniae. The majority of patients were treated with antibiotics and closed drainage. Some patients needed open drainage (16.4 percent) or decortication (3.3 percent). The mean duration of hospitalization was $28.6{\pm}15.3days$. Conclusion : We analyzed childhood empyema patients during a period of 5 years in Korean children. The most frequent age group was 1-3 years and the most common causative agent was Streptococcus pneumoniaeiae. The majority of patients were treated with antibiotics and close drainage.

Dosimetry of the Low Fluence Fast Neutron Beams for Boron Neutron Capture Therapy (붕소-중성자 포획치료를 위한 미세 속중성자 선량 특성 연구)

  • Lee, Dong-Han;Ji, Young-Hoon;Lee, Dong-Hoon;Park, Hyun-Joo;Lee, Suk;Lee, Kyung-Hoo;Suh, So-Heigh;Kim, Mi-Sook;Cho, Chul-Koo;Yoo, Seong-Yul;Yu, Hyung-Jun;Gwak, Ho-Shin;Rhee, Chang-Hun
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.66-73
    • /
    • 2001
  • Purpose : For the research of Boron Neutron Capture Therapy (BNCT), fast neutrons generated from the MC-50 cyclotron with maximum energy of 34.4 MeV in Korea Cancer Center Hospital were moderated by 70 cm paraffin and then the dose characteristics were investigated. Using these results, we hope to establish the protocol about dose measurement of epi-thermal neutron, to make a basis of dose characteristic of epi-thermal neutron emitted from nuclear reactor, and to find feasibility about accelerator-based BNCT. Method and Materials : For measuring the absorbed dose and dose distribution of fast neutron beams, we used Unidos 10005 (PTW, Germany) electrometer and IC-17 (Far West, USA), IC-18, ElC-1 ion chambers manufactured by A-150 plastic and used IC-l7M ion chamber manufactured by magnesium for gamma dose. There chambers were flushed with tissue equivalent gas and argon gas and then the flow rate was S co per minute. Using Monte Carlo N-Particle (MCNP) code, transport program in mixed field with neutron, photon, electron, two dimensional dose and energy fluence distribution was calculated and there results were compared with measured results. Results : The absorbed dose of fast neutron beams was $6.47\times10^{-3}$ cGy per 1 MU at the 4 cm depth of the water phantom, which is assumed to be effective depth for BNCT. The magnitude of gamma contamination intermingled with fast neutron beams was $65.2{\pm}0.9\%$ at the same depth. In the dose distribution according to the depth of water, the neutron dose decreased linearly and the gamma dose decreased exponentially as the depth was deepened. The factor expressed energy level, $D_{20}/D_{10}$, of the total dose was 0.718. Conclusion : Through the direct measurement using the two ion chambers, which is made different wall materials, and computer calculation of isodose distribution using MCNP simulation method, we have found the dose characteristics of low fluence fast neutron beams. If the power supply and the target material, which generate high voltage and current, will be developed and gamma contamination was reduced by lead or bismuth, we think, it may be possible to accelerator-based BNCT.

  • PDF