• Title/Summary/Keyword: 방사선 조사영역

Search Result 298, Processing Time 0.034 seconds

The Study for Radio Protection According to a Possible Danger of Exposure During dental X-ray Examination (치과 방사선 검사 시 노출 위험성에 따른 피폭선량 방어연구)

  • Lim, Cheong-Hwan;Kim, Seung-Chul;Jung, Hong-Ryang;Hong, Dong-Hee;You, In-Gyu;Jeong, Cheon-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.5
    • /
    • pp.237-244
    • /
    • 2011
  • Generally, X-ray examinations for dentistry use low energy radiation. It explains that the radiations are mainly absorbed to a human body because of the weak permeability. We made up some counterplans for decrease in radiation exposure, when guardians and radiologists are overexposed owing to unavoidable circumstances. The equipments for the test are GX-770 and CRANEX TOME CEPH which are used for various exams. Besides we measured the radiations in the projection room and in the control room using model 2026c and 20X6-1800. According to the test, the measurement value in the control room was low dose below $20{\mu}R$, the maximum dose in the projection room was $702.8{\mu}R$ and the measurement value of back dose was higher than lateral one. As the result, if we use a shielding door, it's effective for radioprotection and when we didn't prepare protectors, we should secure appropriate distance and be situated at the side area($90{\sim}135^{\circ}$) on the basis of centeral radiation. That way will provide valuable aid for radioprotection.

Development of Error Analysis Program for Phase-based Respiratory Gating Radiation Therapy (위상기반 호흡연동 방사선치료 시 오차 분석 프로그램 개발)

  • Song, Ju-Young;Nah, Byung-Sik;Chung, Woong-Ki;Ahn, Sung-Ja;Nam, Taek-Keun;Yoon, Mi-Sun
    • Progress in Medical Physics
    • /
    • v.17 no.3
    • /
    • pp.136-143
    • /
    • 2006
  • The respiratory gating radiation therapy which Irradiates only in the stable respiratory period with analyzing the periodic motion of a reflective marker on the patient's abdomen has been applied to the precise radiation treatment in order to minimize the effect of organ motion induced by the respiration. This respiratory gating system establishes irradiation region using the amplitude-based or phase-based method. Although phase-based method Is preferred because of the stability in the real treatment conditions, it has some limits to explain the exact correlation between the marker motion and organ motion. Even when the variation of amplitude which can introduce target motion considered as an error is produced, the phase-based method has the possibility to irradiate including the error positions. In this study, the error analysis program was developed for the verification of the tumor position's variation correlated with the variation of marker's amplitude which can be occurred during a phase-based respiratory sating treatment. The analysis program was tested with a virtual treatment record file and with a record file using moving phantom which were modified considering the irregular amplitude's variation simulating the real clinical situations. In both cases, accurate discrimination of error points and error calculation were produced. When the treatment record files of a real patient were analyzed with the program, the accurate recognition and calculation of the error points were also verified. The analysis program developed in this study will be applied as a useful tool for the analysis of errors due to the irregular variation of patients' respiration during the phase-base respiratory gating radiation treatment.

  • PDF

Electrical conduction phenomena of OPP film irradiated by $Co^60-\gamma$ rays ($Co^60-\gamma$선으로 조사된 이축 연신 폴리프로필렌 필름의 전기전도 현상)

  • 박승협;박영제;이준웅
    • Electrical & Electronic Materials
    • /
    • v.4 no.2
    • /
    • pp.132-142
    • /
    • 1991
  • 본 연구에서는 유기절연재료의 재방사선 재료개발을 위한다는 측면에서 두께 15[.mu.m]의 이축 연신 폴리프로필렌 필름을 시료로 선정하여 Co$^{60}$-.gamma.으로 조사시켜 온도 25-55[.deg.C], 전계 10-250[MV/m]사이에서 방사선 조사량 변화에 따른 전기전도현상을 연구하였다. 조사된 시료의 전기전도는 온도에 크게 의존하여 전계의 증가와 더불어 각기 다른 전도기구 특성을 갖는 4개의 영역으로 구분되었는데 각 영역별로 조사선량 변화에 따른 하전입자들의 거동상황을 규명하고 기초적인 제 물성정수를 결정하였다.

  • PDF

Automatic Heart Segmentation in a Cardiac Ultrasound Image (초음파 심장 영상에서 자동 심장 분할 방법)

  • Lee, Jae-Jun;Kim, Dong-Sung
    • Journal of KIISE:Software and Applications
    • /
    • v.33 no.4
    • /
    • pp.418-426
    • /
    • 2006
  • This paper proposes a robust and efficient segmentation method for a cardiac ultrasound image taken from a probe inserted into the heart in surgery. The method consists of three steps: initial boundary extraction, whole boundary modification using confidence competition, and local boundary modification using the rolling spoke method. Firstly, the initial boundary is extracted with threshold regions along the global spokes emitted from the center of an ultrasound probe. Secondly, high confidence boundary edges are detected along the global spokes by competing among initial boundary candidate and new candidates achieved by edge and appearance information. finally, the boundary is modified by rolling local spokes along concave regions that are difficult to extract using the global spokes. The proposed method produces promising segmentation results for the ultrasound cardiac images acquired during surgery.

A Study on Characteristic of Glass Dosimeter According to Graded Change of Tube Current (유리선량계의 단계별 관전류량 변화에 따른 특성연구)

  • Son, Jin-Hyun;Kim, Seong-Ho;Mun, Hyun-Jun;Kim, Lyun-Kyun;Son, In-Hwa;Kim, Young-Jun;Min, Jung-Whan;Kim, Ki-Won
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.135-141
    • /
    • 2014
  • This study was evaluated the linearity and reproducibility according to dose, and reproducibility according to delay time by changing tube current amount (5 mAs, 10 mAs, 16 mAs, 20 mAs, 25 mAs, 32 mAs respectively, which are low energy radiations) using Glass Dosimeter (GD) and piranha semiconductor dosimeter which are used for measuring exposure dose. Measurements of radiation dose were performed using external detector of piranha 657 which is multi-function QA device (RTI Electronic, Sweden). Conditions of measurement were 80 kVp, SSD 100 cm and exposure region is $10cm{\times}10cm$. Glass dosimeter was exposed to radiation. Twenty-four glass dosimeters were divided into six groups (5 mAs, 10 mAs, 16 mAs, 20 mAs, 25 mAs, 32 mAs respectively), then measured. This study was resulted by measuring the linearity and reproducibility according to change of tube current in low energy field. In dose characteristic of GD, this study could be useful as previous study with regard to dose characteristic according to change of tube voltage in low energy field.

Perineal Skin Toxicity according to Irradiation Technique in Radiotherapy of Anal Cancer (항문암의 방사선치료 시 방사선 조사 기법에 따른 회음부 피부 독성)

  • You, Sei-Hwan;Seong, Jin-Sil;Koom, Woong-Sub
    • Radiation Oncology Journal
    • /
    • v.26 no.4
    • /
    • pp.222-228
    • /
    • 2008
  • Purpose: Various treatment techniques have been attempted for the radiotherapy of anal cancer because of acute side effects such as perineal skin reactions. This study was performed to investigate an optimal radiotherapy technique in anal cancer. Materials and Methods: The study subjects included 35 patients who underwent definitive concurrent chemoradiotherapy for anal cancer in Yonsei Cancer Center between 1990 and 2007. The patients' clinical data, including irradiation technique, were reviewed retrospectively. The primary lesion, regional lymph nodes, and both inguinal lymph nodes were irradiated by $41.4{\sim}45\;Gy$ with a conventional schedule, followed by a boost does to the primary lesion or metastatic lymph nodes. The radiotherapy technique was classified into four categories according to the irradiation field and number of portals. In turn, acute skin reactions associated with the treatment interruption period were investigated according to each of the four techniques. Results: 28 patients (80.0%) had grade 2 radiation dermatitis or greater, whereas 10 patients (28.6%) had grade 3 radiation dermatitis or greater during radiotherapy. Radiation dermatitis and the treatment interruption period were relatively lower in patients belonging to the posterior-right-left 3 x-ray field with inguinal electron boost and in patients belonging to electron thunderbird techniques. The interruption periods were $8.2{\pm}10.2$ and $5.7{\pm}7.7$ for the two technique groups, respectively. Twenty-seven patients (77.1%) went into complete remission at 1 month after radiotherapy and the overall 5 year survival rates were 67.7%. Conclusion: Field size and beam arrangement can affect patients' compliance in anal cancer radiotherapy, whereas a small x-ray field for the perineum seems to be helpful by decreasing severe radiation dermatitis.

A Study on the Characteristics of Therapy Radiation Detector with Diode (다이오드를 이용한 치료방사선 검출기의 특성에 관한 연구)

  • 이동훈;지영훈
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.2
    • /
    • pp.129-138
    • /
    • 1995
  • High-energy and high-dose X-ray and electron beam have been used in radiation therapy after developing particle accelerators. It is recommended to irradiate patients exect real dose for improving therapy effectiveness by International Committee on Radiation Units and Measurement. The radiation detector for daily beam checks of medical accelerators is described. Using thirteen silicon diodes, we have designed the diode detector providing information about calibration, beam symmetry, flatness, stability variation according to radiation damage, time and general quality assurance for both photon and eletron beams. we also compared these measurement values with those of using ionization chamber, film and semiconductor dosimeter.

  • PDF

Morphological Changes of Stomach Tissue on NPO(nil per os) of Rats Treated Single Irradiation (방사선 단일조사가 금식시킨 흰쥐 위에 미치는 형태학적 변화)

  • Kim, Boo-Soon
    • Journal of radiological science and technology
    • /
    • v.21 no.1
    • /
    • pp.69-78
    • /
    • 1998
  • In this study, I examined the morphological influence of radiation on rats stomach tissue, the difference between NPO and CON(contrast) in the rats stomach was measured after a single irradiation to 15 Gy dose, the results follow; In histological observation; focal congestion and epithelial denudation were observed from NPO rats of a day after irradiation. Fibrosis was showed from both of NPO and CON rats of 28day after irradiation, but in it's area, NPO rats have been more wider than CON rats. In PAS reaction; secreted mucin was reacted very weakly from both of NPO and CON rats of 7 days and 14 days after irradiation, whereas CON rats of 28 days after irradiation were reacted like to control rats. On the basis of this results, we know obviously that NPO will be a factor of stomach abnomalities while hospital patients are treated with high-energy irradiation.

  • PDF

Radiation-induced Pulmonary Toxicity following Adjuvant Radiotherapy for Breast Cancer (유방암 환자에서 보조적 방사선치료 후의 폐 손상)

  • Moon, Sung-Ho;Kim, Tae-Jung;Eom, Keun-Young;Kim, Jee-Hyun;Kim, Sung-Won;Kim, Jae-Sung;Kim, In-Ah
    • Radiation Oncology Journal
    • /
    • v.25 no.2
    • /
    • pp.109-117
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: To evaluate the incidences and potential predictive factors for symptomatic radiation pneumonitis (SRP) and radiographic pulmonary toxicity (RPT) following adjuvant radiotherapy (RT) for patients with breast cancer. A particular focus was made to correlate RPT with the dose volume histogram (DVH) parameters based on three-dimensional RT planning (3D-RTP) data. $\underline{Materials\;and\;Methods}$: From September 2003 through February 2006, 171 patients with breast cancer were treated with adjuvant RT following breast surgery. A radiation dose of 50.4 Gy was delivered with tangential photon fields on the whole breast or chest wall. A single anterior oblique photon field for supraclavicular (SCL) nodes was added if indicated. Serial follow-up chest radiographs were reviewed by a chest radiologist. Radiation Therapy Oncology Group (RTOG) toxicity criteria were used for grading SRP and a modified World Health Organization (WHO) grading system was used to evaluate RPT. The overall percentage of the ipsilateral lung volume that received ${\geq}15\;Gy\;(V_{15}),\;20\;Gy\;(V_{20})$, and $30\;Gy\;(V_{30})$ and the mean lung dose (MLD) were calculated. We divided the ipsilateral lung into two territories, and defined separate DVH parameters, i.e., $V_{15\;TNGT},\;V_{20\;TNGT},\;V_{30\;TNGT},\;MLD_{TNGT}$, and $V_{15\;SCL},\;V_{20\;SCL},\;V_{30SCL},\;MLD_{SCL}$ to assess the relationship between these parameters and RPT. $\underline{Results}$: Four patients (2.1%) developed SRP (three with grade 3 and one with grade 2, respectively). There was no significant association of SRP with clinical parameters such as, age, pre-existing lung disease, smoking, chemotherapy, hormonal therapy and regional RT. When 137 patients treated with 3D-RTP were evaluated, 13.9% developed RPT in the tangent (TNGT) territory and 49.2% of 59 patients with regional RT developed RPT in the SCL territory. Regional RT (p<0.001) and age (p=0.039) was significantly correlated with RPT. All DVH parameters except for $V_{15\;TNGT}$ showed a significant correlation with RPT (p<0.05). $MLD_{TNGT}$ was a better predictor for RPT for the TNGT territory than $V_{15\;SCL}$ for the SCL territory. $\underline{Conclusion}$: The incidence of SRP was acceptable with the RT technique that was used. Age and regional RT were significant factors to predict RPT. The DVH parameter was good predictor for RPT for the SCL territory while $MLD_{TNGT}$ was a better predictor for RPT for the TNGT territory.