• Title/Summary/Keyword: 방사선 위험성

Search Result 290, Processing Time 0.022 seconds

Polygonal Model Analysis on Occupational Exposure Record of Radiation Workers by Work Field (업종별 방사선작업종사자 피폭 기록 다각형 모델 분석 연구)

  • Je-Wan Park;Ji-Young Han;Yong-Min Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.2
    • /
    • pp.277-284
    • /
    • 2023
  • Since the radiological risk is different depending on the working environment, protection measures and policies must be developed through analysis of the field area environment. Evaluating the characteristics of the field area that uses radiation should be conducted through comparative analysis with other industries, not just the numerical value of the field area. In this study, evaluation factors were derived from exposure records by the department to compare radiation occupational exposure records by sector. And then, we developed a polygonal model for comparative analysis and applied them to eight work fields through ten evaluation factors. Based on the occupational exposure record in 2020, a polygonal model was applied to compare and evaluate the characteristics of the radiation work area. Through this, the usefulness of the polygonal model was confirmed, and protection policy measures for the industry were proposed.

Radiological Risk Assessment for $^{99m}Tc$ Generator using Uncertainty Analysis (불확실성 분석을 이용한 $^{99m}Tc$ 발생기 사용의 방사선위험도 평가)

  • Jang, H.K.;Kim, J.Y.;Lee, J.K.
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.2
    • /
    • pp.129-139
    • /
    • 2004
  • Recently, much attentions are paid to the risk associated with increased uses of medium size radiation sources in medical and industrial fields. In this study, radiation risks to the worker and to the general public due to $^{99m}Tc$ generator were assessed for both normal and accident conditions. Based on the event tree technique, exposure scenarios for various situations were derived. Uncertainty analysis based on the Monte-Carlo technique was applied to the risk assessment for workers and members of the public in the vicinity of the work place. In addition, sensitivity analysis was performed on each of the five independent input parameters to identify importance of the parameters with respect to the resulting risk. Because the frequencies of normal tasks are fat higher than those of accidents, the total risk associated with normal tasks were higher than the accident risk. The annual dose due to normal tasks were $0.6mSv\;y^{-1}$ for workers and $0.014mSv\;y^{-1}$ for public, while in accident conditions $3.96mSv\;y^{-1}\;and\;0.0016mSv\;y^{-1}$, respectively. Uncertainty range of accident risk was higher by 10 times than that of normal risk. Sensitivity analysis revealed that source strength, working distance and working time were crucial factors affecting risk. This risk analysis methodology and its results will contribute to establishment of risk-informed regulation for medium and large radioactive sources.

Development of Radiation Shield with Environmentally-Friendly Materials ; Ⅰ: Comparison and Evaluation of Fiber, Rubber, Silicon in the Radiation Shielding Sheet (친환경 소재의 의료 방사선 차폐 시트 개발 ; I: 섬유, 고무, 실리콘 소재 차폐 시트의 성능 비교평가)

  • Kim, Seon-Chil;Park, Myeong-Hwan
    • Journal of radiological science and technology
    • /
    • v.33 no.2
    • /
    • pp.121-126
    • /
    • 2010
  • Traditionally, lead has been primarily used to shield the radiation in the hospital, because of its soft texture, durability and cost effectiveness. However, lead can be dangerous because of its toxicity when exposed to the human body, and it is classified as a heavy metal like cadmium, mercury, and arsenic etc. In order to compensate its noxious properties on the human body, researchers are trying to develop a radiation shield which has similar shielding efficiency and can also be manufactured in any form. In this study, sulfuric acid barium was mixed with fiber, rubber, and silicon all of which are harmless to the human body, tested, and evaluated for its ability of medical radiation shield. The result of this study showed that the sheet containing silicon and barium has the strongest shielding abilities.

A Risk Assessment for A Korean Standard Nuclear Power Plant (한국표준형 원전의 중대사고시 MACCS 코드를 이용한 위험성평가)

  • Hwang, Seok-Won;Jae, Moo-Sung
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.3
    • /
    • pp.189-197
    • /
    • 2003
  • The Level 3 PSA being termed accident consequence analysis is defined to assess effects on health and environment caused by radioisotopes released from severe accidents of nuclear power plants. In this study consequence analysis on health effects depending on release characteristics of radioisotopes has been peformed using the 3 MACCS code in severe accidents. The results of this study may contribute to identifying the relative importance of various parameters occurred in consequence analysis as well as to assessing risk reduction accident management strategies. Especially three parameters for the purpose of consequence analysis, such as the release height, the heat content, and the duration time, are used to analyze the variation of early fatalities and latent cancer fatalities. Also, in this study risk assessment using the concept, 'products of uncertainty and consequences', has been performed using consequence of MACCS and frequency on source term category 19 scenarios from IPE (Individual Plant Examination) analysis.

새천년 : 가치, 위험의 인식 그리고 과학기술의 주요역할

  • Korea Radioisotope Association
    • Radioisotope journal
    • /
    • v.16 no.3
    • /
    • pp.89-95
    • /
    • 2001
  • 방사선방호 및 방사성 폐기물 유출 및 산물에 대한 관리는 새 천년의 공공정책, 종사자교육 및 기술개발에 있어 매우 중요하다. 자유, 지탱능력, 투명성 그리고 기술로부터 오는 이익과 위험에 대한 의사결정에의 대중 참여 등에 대한 가치 남용은 새 천년의 공공 정책 의사결정 체계를 형성하게 될 것이다. 위험의 확인과 평가, 그리고 위험 관리에 대한 의사전달시 초기에 제3자를 개입시키는 것이 유용하다. 특정 환경문제를 더 넓은 공중보건과 생태계의 항목에 포함시키는 것은 모두에게 도움이 될 것이며, 또한 귀중한 자원을 가장 효과적으로 사용하기 위해 더 나은 결정을 도와줄 것이며, 과정과 결과에 대한 대중의 신뢰를 높혀줄 것이다.

  • PDF

A Study on the Secondary Carcinogenesis Rate of Vestibular Schwannoma Disease using Glass Dosimeter (유리선량계를 이용한 청신경초종 질환의 2차 발암률에 관한 연구)

  • Joo-Ah Lee;Gi-Hong Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.2
    • /
    • pp.243-248
    • /
    • 2023
  • This study aims to analyze the secondary carcinogenesis rate caused by exposure of organs at risk of damage using a glass dosimeter during radiosurgery in vestibular schwannoma disease. Using a pediatric phantom of human tissue equivalent material, the volume of the tumor was set to a total of three volumes: 0.506 cm3, 1.008 cm3, and 2.032 cm3, and a radiosurgery plan was established with an average dose of 18.4 ± 3.4 Gy. After mounting the human body phantom on the table of surgical equipment, glass dosimeters were placed on the right eye, left eye, thyroid gland, thymus, right lung, and left lung to measure the exposure dose, respectively. In this study, the incidence of secondary cancer due to exposure to damaged organs during gamma knife radiosurgery in vestibular schwannoma disease with the largest tumor volume of 2.032 cm3 was measured with a glass dosimeter. This study studies the risk of secondary radiation exposure dose that can occur during stereotactic radiosurgery, and it is considered that it will be used as basic data in the field of radiation damage related to the stochastic effect of radiation in the future.

A Study on Radiation Exposure using Nominal Risk Coefficients (명목위험계수를 활용한 방사선 피폭에 관한 연구)

  • Joo-Ah Lee;Jong-Gil Kwak;Cheol-Min Jeon
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.4
    • /
    • pp.383-389
    • /
    • 2024
  • In this study, we aimed to analyze the probability of secondary cancer occurring in the abdomen, a normal organ, due to photoneutron exposure during intensity-modulated radiotherapy for prostate cancer. The design of the radiation treatment plan for prostate cancer was established as a daily prescription dose of 220 cGy, a total of 35 treatments, and 7700 cGy. The experimental equipment was a True Beam STx (Varian, USA) linear accelerator from Varian. The energy used in the experiment was 15 MV, and the treatment plan was designed so that the photoneutron dose would be generated within the planning target volume (PTV). The radiation treatment plan was an Eclipse System (Varian Ver. 10.0, USA), and the number of irradiation portals was set to 5 to 9. The irradiation angle was designed so that 95% of the prescription dose area was set to 0 to 320°, and the number of beamlets per irradiation portal was set to 100. The optically stimulated luminescence dosimeter used in this study to measure the dose of photoneutrons was designed to measure photoneutron doses by coating 6LiCO3 on a device containing aluminum oxide components. It was studied that there is a minimum of 7.07 to 11 cases per 1,000 people with secondary cancer due to the photoneutron dose to the abdomen during intensity-modulated radiotherapy. In this study, we studied the risk of secondary radiation dose that may occur during intensity-modulated radiotherapy, and we expect that this will be used as meaningful data related to the probabilistic effects of radiation in the future.

Perception Survey of Nuclear Power after the Nuclear Plant and Thyroid Cancer Controversy (원자력발전소와 갑상선암 논란 이후 원자력에 대한 인식 조사)

  • Lee, Jae-Heon;Park, Eun-tae
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.1
    • /
    • pp.19-25
    • /
    • 2017
  • In this study, in order to analyze the general awareness of the nuclear power according to the controversy of thyroid cancer around nuclear plant, we investigated risks, preference and economics regarding type of power, and awareness of pre-post nucl ear power targeting the Busan Metropolitan residents. As a result, there has been a change in people's awareness of nuclear power as a result of the controversy thyroid cancer around nuclear plant. Especially, there was the greatest increase in the risk factors compared to before the event(p<0.05). Negative awareness of nuclear risk was shown to be expressed differently accor ding to the difference between groups. It is thought that this is due to the different prior experience of each individuals or obtained information through the interaction with others rather than on scientific and objective grounds. In order to establish a nuclear power policy considering the level of the people in the future, it seems that the efforts to understand the attitudes and opinions of people about nuclear power and above all, a scientific trust in nuclear power should be guaranteed.

Development of a Medical Radiation Simulator System for Education and Proposal of a Research Model (교육용 의료방사선 시뮬레이터 시스템 개발 및 연구 모델 제안)

  • Chang-Hwa Han;Young-Hwang Jeon;Jae-Bok Han;Chang-gi Kong;Jong-Nam Song
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.459-464
    • /
    • 2023
  • Due to the development of advanced technology, a lot of digital radiographic equipment has been developed, which is very helpful for accurate diagnosis and treatment, and it is very important to train personnel who have acquired professional knowledge in order to use it safely and effectively. Students are exposed to the risk of radiation exposure in radiography training using diagnostic X-ray equipment, and some educational institutions do not use X-ray equipment due to management difficulties in accordance with the Nuclear Safety Act. As a solution to this, this study developed a medical radiation simulator for education that does not generate radiation by using a vision sensor and self-developed software. Through this, educational institutions can reduce the burden of administrative implementation according to the law, and students can obtain a high level of educational effects in a healthy practice environment without radiation exposure.

Research on the Operation of Safeguards Equipment in Extreme Environmental Conditions (극한 환경 내 안전조치 장비 운영에 관한 연구)

  • Jiyoung Han;Suhui Park;Jewan Park;Yongmin Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1189-1195
    • /
    • 2023
  • In scenarios involving inspections and verifications of nuclear facilities, ensuring the proper functioning of on-site safeguards equipment is crucial. There have been precedents in Kazakhstan where equipment failed to operate properly due to extremly cold temperatures, and the year-round minimum temperature at North Korea's Punggye-ri nuclear test site is approximately minus 30 degrees Celsius. To ensure the proper functioning of equipment in extreme environments for on-site verification of nuclear activities on the Korean Peninsula, relevant research is necessary. This includes confirming the functionality of equipment used in inspections and verifications, as well as analyzing factors that may disrupt their normal operation. This study aims to conduct a risk analysis for the normal operation of equipment in extreme environments and develop criteria and procedures for environmental-based performance testing. To achieve this, we conducted a risk analysis based on IAEA safeguards, analyzed the utilization of equipment, and performed a risk analysis associated with transportation for on-site verification considering the environmental characteristics of the Korean Peninsula. Furthermore, we provided performance testing criteria and procedures. The research results can be utilized as reference material in the verification and monitoring processes of nuclear activities.