Quality Assurance of Leaf Speed for Dynamic Multileaf Collimator (MLC) Using Dynalog Files (Dynalog file을 이용한 동적다엽조준기의 Leaf 속도 정도관리 평가)

  • Kim, Joo Seob;Ahn, Woo Sang;Lee, Woo Suk;Park, Sung Ho;Choi, Wonsik;Shin, Seong Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.305-312
    • /
    • 2014
  • Purpose : The purpose of this study is to analyze the mechanical and leaf speed accuracy of the dynamic multileaf collimator (DMLC) and determine the appropriate period of quality assurance (QA). Materials and Methods : The quality assurance of the DMLC equipped with Millennium 120 leaves has been performed total 92 times from January 2012 to June 2014. The the accuracy of leaf position and isocenter coincidence for MLC were checked using the graph paper and Gafchromic EBT film, respectively. The stability of leaf speed was verified using a test file requiring the leaves to reach maximum leaf speed during the gantry rotation. At the end of every leaf speed QA, dynamic dynalog files created by MLC controller were analyzed using dynalog file viewer software. This file concludes the information about the planned versus actual position for all leaves and provides error RMS (root-mean square) for individual leaf deviations and error histogram for all leaf deviations. In this study, the data obtained from the leaf speed QA were used to screen the performance degradation of leaf speed and determine the need for motor replacement. Results : The leaf position accuracy and isocenteric coincidence of MLC was observed within a tolerance range recommanded from TG-142 reports. Total number of motor replacement were 56 motors over whole QA period. For all motors replaced from QA, gradually increased patterns of error RMS values were much more than suddenly increased patterns of error RMS values. Average error RMS values of gradually and suddenly increased patterns were 0.298 cm and 0.273 cm, respectively. However, The average error RMS values were within 0.35 cm recommended by the vendor, motors were replaced according to the criteria of no counts with misplacement > 1 cm. On average, motor replacement for gradually increased patterns of error RMS values 22 days. 28 motors were replaced regardless of the leaf speed QA. Conclusion : This study performed the periodic MLC QA for analyzing the mechanical and leaf speed accuracy of the dynamic multileaf collimator (DMLC). The leaf position accuracy and isocenteric coincidence showed whthin of MLC evaluation is observed within the tolerance value recommanded by TG-142 report. Based on the result obtained from leaf speed QA, we have concluded that QA protocol of leaf speed for DMLC was performed at least bimonthly in order to screen the performance of leaf speed. The periodic QA protocol can help to ensure for delivering accurate IMRT treatment to patients maintaining the performance of leaf speed.

Methodological Issues in Socio-Economic Assessment of the Hydrogen Economy Development (수소경제로 이행을 위한 사회경제적 영향평가 방법론)

  • Kim, Ho-Seok
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.586-591
    • /
    • 2005
  • 우리나라는 에너지의 안정적 공급과 에너지이용 과정에서 발생하는 환경적, 안보적 외부성을 최소화하는 에너지수급 구조를 마련하기 위해 2003년 12월 '제2차 신재생에너지 기술개발 및 이용보급 기본계획(2003-2012)'을 발표하였다. 이 계획에서는 2011년까지 전체 TPES의 $5\%$를 신재생에너지로 공급하는 것을 정책목표로 수립하고 수소, 태양광 그리고 풍력기술을 중점적으로 추진하기로 하였다. 특히 수소부문에서는 주택 및 건물용, 발전용, 수송용 연료전지의 개발을 중심으로 개발하여 세계 기술시장의 $20\%$를 확보한다는 계획을 발표하였다. 이러한 기술 잠재력을 기반으로 우리 정부도 미국이나 일본과 같이 수소경제로의 전환을 준비하고 있으며 2020년대 이후 우리나라의 에너지부문은 새로운 국면에 접어들 것으로 전망된다. 에너지나 환경기술의 효과적 인 개발을 위해서는 이들 기술의 직접적인 비용측면에 대한 분석 즉 경제성 평가와 새로운 기술변화로 인한 중장기적인 사회경제적 영향평가가 선행되어야 한다. 이러한 평가는 대상 기술의 사회경제적 파급효과가 광범위할수록 더욱 복잡한 분석이 요구된다. 본 연구의 주제인 수소에너지기술은 지금까지 이용되던 것과는 전혀 새로운 에너지캐리어(carrier)를 개발하는 것으로 에너지부문 및 여타 다른 산업부문이 공유하고 있는 에너지 관련 인프라의 전면적인 조정이 요구되며 에너지 이용과 관련된 사회경제적 측면의 급속한 변화를 수반한다. 본 연구는 수소경제로의 이행에 대한 사회경제적 영향평가의 방법론적 요소들과 기법을 제시한다."중등도 독성"으로 나타났다 이상의 결과는 전기도금을 이용하여 교정용 선재의 직경을 증가시키는 방법이 임상에 적용되기 위해서는 세포독성을 줄이기 위한 추가의 연구가 필요함을 시사하였다.의하게 가장 낮은 정지. 운동 마찰력을 보였고 브라켓-호선 각도가 증가함에 따라 유의하게 정지, 운동 마찰력도 증가하였다 (P<0.001)%$ 낮추지만(p value=0.260) 평균 $D_{max}$는 거의동일 하여($0.3\%$ 감소, p value=0.867), 전통적인 방법보다 우수성이 크게는 없는 것으로 평가되었다. 그러나 환자의 체곡선이 보상체와 잘 일치하는 경우에는 DII가 $18\%$까지 감소하였다. 결론 : Multistatic field 방법은 모든 환자에 대하여 선량분포의 균일성을 전반적으로 향상시키는 효과적인 방법으로 평가되는 반면 공용보상체의 사용은 보상체의 크기가 환자의 체 윤곽과 잘 일치하는 경우만 효과적으로, 적용의 범위에는 한계가 있는 방법으로 평가되었다.비교하여 계통에 따르는 차이가 있음을 알 수 있었다. 그러므로 가임기 여성의 방사선 진단 및 치료시 Rugh의 10일 법칙을 적용하여 착상전기 방사선 조사로 인한 부작용들을 적극적으로 예방하는 것이 매우 중요하다고 생각한다.equirements of the prematured infants during the early weeks of life. 모든 치근단 수준에서 비표준화 medium 크기 master cone 사용군이 ISO 표준화 규격의 master cone 사용군에 비해

  • PDF

Verification of Dose Distribution for Stereotactic Radiosurgery with a Linear Accelerator (선형가속기를 이용한 방사선 수술의 선량분포의 실험적 확인)

  • Park Kyung Ran;Kim Kye Jun;Chu Sung Sil;Lee Jong Young;Joh Chul Woo;Lee Chang Geol;Suh Chang Ok;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.11 no.2
    • /
    • pp.421-430
    • /
    • 1993
  • The calculation of dose distribution in multiple arc stereotactic radiotherapy is a three-dimensional problem and, therefore, the three-dimensional dose calculation algorithm is important and the algorithm's accuracy and reliability should be confirmed experimentally. The aim of this study is to verify the dose distribution of stereotactic radiosurgery experimentally and to investigate the effect of the beam quality, the number of arcs of radiation, and the tertiary collimation on the resulting dose distribution. Film dosimetry with phantom measurements was done to get the three-dimensional orthogonal isodose distribution. All experiments were carried out with a 6 MV X-ray, except for the study of the effects of beam energy on dose distribution, which was done for X-ray energies of 6 and 15 MV. The irradiation technique was from 4 to 11 arcs at intervals of from 15 to 45 degrees between each arc with various field sizes with additional circular collimator. The dose distributions of square field with linear accelerator collimator compared with the dose distributions obtained using circular field with tertiary collimator. The parameters used for comparing the results were the shape of the isodose curve, dose fall-offs fom $90\%$ to $50\%$ and from $90\%\;to\;20\%$ isodose line for the steepest and shallowest profile, and $A=\frac{90\%\;isodose\;area}{50\%\;isodose\;area-90\%\;isodose\;area}$(modified from Chierego). This ratio may be considered as being proportional to the sparing of normal tissue around the target volume. The effect of beam energy in 6 and 15 MV X-ray indicated that the shapes of isodose curves were the same. The value of ratio A and the steepest and shallowest dose fall-offs for 6 MV X-ray was minimally better than that for 15 MV X-ray. These data illustrated that an increase in the dimensions of the field from 10 to 28 mm in diameter did not significantly change the isodose distribution. There was no significant difference in dose gradient and the shape of isodose curve regardless of the number of arcs for field sizes of 10, 21, and 32 mm in diameter. The shape of isodose curves was more circular in circular field and square in square field. And the dose gradient for the circular field was slightly better than that for the square field.

  • PDF

Design and Application of Acrylic Electron Wedge to Improve Dose Inhomogeneities at the Junction of Electron Fields (전자선 조사야 결합부분의 선량분포 개선을 위한 Acrylic Electron Wedge의 제작 및 사용)

  • Kim Young Bum;Kwon Young Ho;Whang Woong Ku;Kim You Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.10 no.1
    • /
    • pp.60-68
    • /
    • 1998
  • Treatment of a large diseased area with electron often requires the use of two or more adjoining fields. In such cases, not only electron beam divergence and lateral scattering but also fields overlapping and separation may lead to significant dose inhomogeneities(${\pm}20\%$) at the field junction area. In this study, we made Acrylic Electron Wedges to improve dose homogeneities(${\pm}5\%$) in these junction areas and considered application it to clinical practices. All measurements were made using 6, 9, 12, 16, 20MeV Electron beams from a linear accelerator for a $10{\times}10cm$ field at 100cm SSD. Adding a 1 mm sheet of acryl gradually from 1 mm to 15 mm, We acquired central axis depth dose beam profile and isodose curves in water phantom. As a result, for all energies, the practical range was reduced by approximately the same distance as the thickness of the acryl insert, e.g. a 1 mm thick acryl insert reduce the practical range by approximately 1 mm. For every mm thickness of acryl inserted, the beam energy was reduced by approximately 0.2MeV. These effects were almost independent of beam energy and field size. The use of Acrylic Electron Wedges produced a small increase $(less\;than\;3\%)\;in\;the\;surface\;dose\;and\;a\;small\;Increase(less\;than\;1\%)$ in X-ray contamination. For acryl inserts, thickness of 3 mm or greater, the penumbra width increased nearly linear for all energies and isodose curves near the beam edge were nearly parallel with the incident beam direction, and penumbra width was $35\;mm{\sim}40\;mm$. We decide heel thickness and angle of the wedge at this point. These data provide the information necessary to design Acrylic Electron Wedge which can be use to improve dose uniformity at electron field junctions and it will be effectively applicated in clinical practices.

  • PDF

Studies on the Relationship between Radiosensitivity and Mutation Induction in Soybean (대두의 방사선감수성과 돌연변이 출현양상에 관한 연구)

  • Kwon, S.H.;Won, J.L.
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.26 no.4
    • /
    • pp.318-323
    • /
    • 1981
  • This study was conducted to establish an effective radiation treatment and selection method for induced mutants in M_1 population of soybean treated with gamma-ray. About 64% of total M_1 plants was reduced in plant height up to 50 - 60% and among which 60 - 70% of the plants were contained mutations in M_2 generation. About 60% of the MI plants have born 6 - 15 seeds per plant and 50 - 60% of their progenies produced mutants in M_2 generation. Positive correlation between plant height and number of seeds per plant in M_1 population was found. Higher visible macro-mutation rate in M_2 was observed in the groups of reduced plant height and seed number in the M_1 generation, whereas the frequency of chlorophyll mutation was increased in the group of less damaged plants. The size of mutation sector was increased with reduction in number of seeds per M_1 plant and the mutants were occurred at random in all the parts of M_1 plants. For the effective selection of mutants in soybean mutation breeding, the M_1 seeds should be harvested from the radiation damaged M_1 plants with the application of higher doses of mutagens, and handling M_2 generation by bulk population method is recommendable.

  • PDF

The Results of Curative Radiotherapy for the Uterine Cervical Cancer (자궁경부암의 근치적 방사선치료 성적)

  • Kim, Hyoung-Jin;Kim, Jung-Soo;Kwon, Hyoung-Cheol;Kim, Jin-Kee;Oh, Byung-Chan
    • Radiation Oncology Journal
    • /
    • v.14 no.3
    • /
    • pp.191-199
    • /
    • 1996
  • Purpose : To evaluate 5-year survival rate, patterns of failure and complications of cervical cancer treatment, fifty nine patients treated by curative radiotherapy for the uterine cervical cancer were analyzed retrospectively. Materials and Methods : From March 1986 to May 1990, fifty nine patients with histologically proven uterine cervical cancer were analyzed. According to FIGO stage, there were 2 patients ($3.4\%$) in stage Ib, 2 patients ($3.4\%$) in stage IIa, 31 patients ($52.5\%$) in stage IIb, 15 patients ($25.4\%$) in stage IIIb, 9 patients ($15.3\%$) in stage IV. External RT was per formed by 6 MVLINAC with daily 1.8 Gy, 5 times per week and followed by ICR. A point dose of ICR was calculated to 30-43.66 Gy (median: 34.6 Gy). These techniques delivered total A Point dose of 80.4 to 109.8 Gy (median: 85 Gy). Patients had been followed up from 2 to 110 months (median: 61 months) Results : The overall 5-year survival rate & disease free survival rate were $55.9\%$ and $55.0\%$ respectively. According to FIGO stage, the 5-year survival rate for less than IIa, IIb, IIIb, IV were $75.0\%$, $74.8\%$, $26.7\%$, $33.3\%$, respectively. In univariate analysis, the 5-year survival rate for stage IIb and below versus stage IIIa and above revealed $74.8\%$, $29.2\%$ respectively (P<0.005). According to the hemoglobin level during RT, the 5-rear survival rate of was $73.3\%$ for patients with Hg 10 gm/dL or higher, in contrast to $0\%$ for those with lower than 10 gm/dL (p<0.005). In 18 patients with nonbulky tumor (<5cm), the 5-year survival rates were $71.8\%$. The 5-rear survival rates for 18 patients with 5 cm or greater in tumor diameter were $22.2\%$ (p<0.005). The 5-year survival rate for Patient age of above 50 years and below were $65.3\%$ $34.2\%$ respectively (p<0.05). ECOG performance status. pathologic finding, total dose, total treatment time were not statistically significant factors. The significant prognostic factors affecting overall 5-year survival rate by multivariate analysis showed the hemoglobin level during RT (P=0.0001), tumor size (p=0.0390), FIGO stage (p=0.0468). Total recurrence rate was $23.7\%$ local failure $15.2\%$ (9/59), distant metastasis $6.8\%$ (4/59), local and distant metastasis $1.7\%$ (1/59). According to the RTOG/EORTC Soma Scales, the late complication rate was $23.8\%$ (14/59) The late complication rate of colorectum and genitourinary tract were $15.3\%$ (9/59), $8.5\%$ (5/59), respectively: 10 patients ($17.0\%$) were grade 2, 3 Patients ($5.1\%$) were grade 3 and one patient ($1.7\%$) was grade 4. The late complications were radiation proctitis, rectal bleeding, radiation colitis, diarrhea and radiation cystitis in decreasing order. Conclusion : For improvement of therapeutic results, prospective randomized trials are recomended to discover new prognostic factors and more aggressive radiation therapeutic methods are needed for poor prognostic patients. The adjuvant chemotherapy or radiation-sensitizing agents must be considered to inhibit regional and distant metastasis.

  • PDF

Daily Setup Uncertainties and Organ Motion Based on the Tomoimages in Prostatic Radiotherapy (전립선암 치료 시 Tomoimage에 기초한 Setup 오차에 관한 고찰)

  • Cho, Jeong-Hee;Lee, Sang-Kyu;Kim, Sei-Joon;Na, Soo-Kyung
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.99-106
    • /
    • 2007
  • Purpose: The patient's position and anatomy during the treatment course little bit varies to some extend due to setup uncertainties and organ motions. These factors could affected to not only the dose coverage of the gross tumor but over dosage of normal tissue. Setup uncertainties and organ motions can be minimized by precise patient positioning and rigid immobilization device but some anatomical site such as prostate, the internal organ motion due to physiological processes are challenge. In planning procedure, the clinical target volume is a little bit enlarged to create a planning target volume that accounts for setup uncertainties and organ motion as well. These uncertainties lead to differences between the calculated dose by treatment planning system and the actually delivered dose. The purpose of this study was to evaluate the differences of interfractional displacement of organ and GTV based on the tomoimages. Materials and Methods: Over the course of 3 months, 3 patients, those who has applied rectal balloon, treated for prostatic cancer patient's tomoimage were studied. During the treatment sessions 26 tomoimages per patient, Total 76 tomoimages were collected. Tomoimage had been taken everyday after initial setup with lead marker attached on the patient's skin center to comparing with C-T simulation images. Tomoimage was taken after rectal balloon inflated with 60 cc of air for prostate gland immobilization for daily treatment just before treatment and it was used routinely in each case. The intrarectal balloon was inserted to a depth of 6 cm from the anal verge. MVCT image was taken with 5 mm slice thickness after the intrarectal balloon in place and inflated. For this study, lead balls are used to guide the registration between the MVCT and CT simulation images. There are three image fusion methods in the tomotherapy, bone technique, bone/tissue technique, and full image technique. We used all this 3 methods to analysis the setup errors. Initially, image fusions were based on the visual alignment of lead ball, CT anatomy and CT simulation contours and then the radiation therapist registered the MVCT images with the CT simulation images based on the bone based, rectal balloon based and GTV based respectively and registered image was compared with each others. The average and standard deviation of each X, Y, Z and rotation from the initial planning center was calculated for each patient. The image fusions were based on the visual alignment of lead ball, CT anatomy and CT simulation contours. Results: There was a significant difference in the mean variations of the rectal balloon among the methods. Statistical results based on the bone fusion shows that maximum x-direction shift was 8 mm and 4.2 mm to the y-direction. It was statistically significant (P=<0.0001) in balloon based fusion, maximum X and Y shift was 6 mm, 16mm respectively. One patient's result was more than 16 mm shift and that was derived from the rectal expansions due to the bowl gas and stool. GTV based fusion results ranging from 2.7 to 6.6 mm to the x-direction and 4.3$\sim$7.8 mm to the y-direction respectively. We have checked rotational error in this study but there are no significant differences among fusion methods and the result was 0.37$\pm$0.36 in bone based fusion and 0.34$\pm$0.38 in GTV based fusion.

  • PDF

Development of Simple and Rapid Radioactivity Analysis for Thorium Series in the Products Containing Naturally Occurring Radioactive Materials (NORM) (천연방사성물질(NORM)을 함유한 가공제품 내 토륨계열 방사능 평가를 위한 간단/신속 분석법 개발)

  • Yoo, Jaeryong;Park, Seyoung;Yoon, Seokwon;Ha, Wi-Ho;Lee, Jaekook;Kim, Kwang Pyo
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.1
    • /
    • pp.71-79
    • /
    • 2016
  • Background: It is necessary to analyze radioactivity of naturally occurring radioactive materials (NORM) in products to ensure radiological safety required by Natural Radiation Safety Management Act. The pretreatments for the existing analysis methods require high technology and time. Such destructive pretreatments including grinding and dissolution of samples make impossible to reuse products. We developed a rapid and simple procedure of radioactivity analysis for thorium series in the products containing NORM. Materials and Methods: The developed method requires non-destructive or minimized pretreatment. Radioactivity of the product without pretreatment is initially measured using gamma spectroscopy and then the measured radioactivity is adjusted by considering material composition, mass density, and geometrical shape of the product. The radioactivity adjustment can be made using scaling factors, which is derived by radiation transport Monte Carlo simulation. Necklace, bracelet, male health care product, and tile for health mat were selected as representative products for this study. The products are commonly used by the public and directly contacted with human body and thus resulting in high radiation exposure to the user. Results and Discussion: The scaling factors were derived using MCNPX code and the values ranged from 0.31 to 0.47. If radioactivity of the products is measured without pretreatment, the thorium series may be overestimated by up to 2.8 times. If scaling factors are applied, the difference in radioactivity estimates are reduced to 3-24%. Conclusion : The developed procedure in this study can be used for other products with various materials and shapes and thus ensuring radiological safety.

Neutron fluence measurement at HANARO using fluence monitor method (Fluence Monitor를 이용한 HANARO 노심 내 중성자 플루언스 측정)

  • Lee, Seung-Kyu;Jo, Kwang-Ho;Choo, Kee-Nam;Park, Jin-Suk;Kim, Yong-Kyun
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.4
    • /
    • pp.200-208
    • /
    • 2011
  • The neutron fluence measurement and evaluation technology is very important for material irradiation test. The most essential technology in this study is the neutron irradiation evaluation method using a fluence monitor. The fluence monitors were fabricated with metal wires of the purity ${\geq}$ 99.9%, whose dimensions were 0.1mm diameter, about 3 mm length, and around 150-200 ${\mu}g$ mass range. Three wire samples (Fe, Ni, Ti) were prepared for one irradiation aluminum capsule. Five capsules were irradiated in the OR5 hole of the HANARO reactor at 30 MW power for about 25 days. After irradiation tests, radiation activities were measured with the high purity germanium (HPGe) detector. The reaction rates were calculated by using the measured radiation activity data, and then neutron fluence were obtained from the reaction rates and the weighted neutron cross section with calculated neutron spectrum at the fluence monitor position.

Development of $^{166}Ho$-Stent for the Treatment of Esophageal Cancer (식도암 치료용 $^{166}Ho$-Stent 개발)

  • Park, Kyung-Bae;Kim, Young-Mi;Kim, Kyung-Hwa;Shin, Byung-Chul;Park, Woong-Woo;Han, Kwang-Hee;Chung, Young-Ju;Choi, Sang-Mu;Lee, Jong-Doo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.1
    • /
    • pp.62-73
    • /
    • 2000
  • Purpose: Esophageal cancer patients have a difficulty in the intake of meals through the blocked esophageal lumen, which is caused by an ingrowth of cancer cells and largely influences on the prognosis. It is reported that esophageal cancer has a very low survival rate due to the lack of nourishment and immunity as the result of this. In this study a new radioactive stent, which prevents tumor ingrowth and restenosis by additional radiation treatment, has been developed. Materials and Methods: Using ${\ulcorner}HANARO{\lrcorner}$ research reactor, the radioactive stent assembly ($^{166}Ho$-SA) was prepared by covering the metallic stent with a radioactive sleeve by means of a post-irradiation and pre-irradiation methods. Results: Scanning electron microscopy and autoradiography exhibited that the distribution of $^{165/166}Ho\;(NO_3)$ compounds in polyurethane matrix was homogeneous. A geometrical model of the esophagus considering its structural properties, was developed for the computer simulation of energy deposition to the esophageal wall. The dose distributions of $^{166}Ho$-stent were calculated by means of the EGS4 code system. The sources are considered to be distributed uniformly on the surface in the form of a cylinder with a diameter of 20 mm and length of 40 mm. As an animal experiment, when radioactive stent developed in this study was inserted into the esophagus of a Mongrel dog, tissue destruction and widening of the esophageal lumen were observed. Conclusion: We have developed a new radioactive stent comprising of a radioactive tubular sleeve covering the metallic stent, which emits homogeneous radiation. If it is inserted into the blocked or narrowed lumen, it can lead to local destruction of the tumor due to irradiation effect with dilatation resulting from self-expansion of the metallic property. Accordingly, it is expected that restenosis esophageal lumen by the continuous ingrowth and infiltration of cancer after insertion of our radioactive stent will be decreased remarkably.

  • PDF