• Title/Summary/Keyword: 방사선학적 평가

Search Result 775, Processing Time 0.037 seconds

Usefulness of the Pleural Fluid Adenosine Deaminase with Lymphocyte/Neutrophil Ratio in the Diagnosis of Tuberculous Pleurisy for a Region of Intermediate Prevalence of Tuberculosis (중등도 결핵 유병률 지역에서 결핵성흉막염 진단에 있어 흉수 아데노신 탈아미노효소와 림프구/호중구 비의 유용성)

  • Kim, Chang Hwan;Mo, Eun Kyung;Park, Sung Hoon;Hwang, Yong Il;Jang, Seung Hun;Park, Yong Bum;Kim, Cheol Hong;Kim, Dong-Gyu;Lee, Myung Goo;Hyun, In Gyu;Jung, Ki-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.66 no.6
    • /
    • pp.437-443
    • /
    • 2009
  • Background: The aim of this study was to consider the significance of pleural fluid adenosine deaminase (ADA) activity combined with lymphocyte/neutrophil (L/N) ratio in the diagnosis of tuberculous pleurisy (TBpl) in a region of intermediate prevalence of tuberculosis (TB). Methods: We collected data from 388 patients with exudative pleural effusions. The final diagnoses were compared to the results from our diagnostic method using pleural fluid ADA and L/N ratio. Results: 108 patients had a final diagnosis of TBpl; 102 cases had high levels of ADA ($\geq$40 IU/L). When we considered ADA $\geq$40 IU/L as a diagnostic criterion, the sensitivity was 94.4%, specificity 87.5%, and posttest posttest probability 74.5%. However, when we considered ADA $\geq$40 IU/L combined with the L/N ratio $\geq$0.75 as a diagnostic criterion, the specificity and post-test probability were rose to 97.5% and 93%, respectively. The other causes of high ADA and L/N ratios were lymphoma and metastatic carcinoma, but mass-like lesions were found on the chest radiographs or CT scans. Conclusion: To evaluate the causes of exudative pleural effusions in a region of intermediate prevalence of tuberculosis, we recommend measuring the pleural fluid ADA and L/N ratio first. If the result is high and malignancies are not suspected, it may be diagnostic of TBpl.

VCUG Studies on the Clinical Usefulness of Aids (VCUG 보조기구의 임상적 유용성에 관한 고찰)

  • Choe, Dea yeon;Kim, Dong hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.7
    • /
    • pp.529-533
    • /
    • 2015
  • VCUG(Voiding Cystourethrography) study is being performed to check urinary reflex symptom from bladder to ureter or kidney in the method of filling the bladder with radiation opaque contrast agent. However, VCUG study have been performed impersonally, patients have to be naked and open their legs and then void. This method is so impersonal that it is immediately needed to improve the way of testing and crete new aid. Therefore, this study through producing underwear for VCUG, analysis and compares the test time of VCUG, patient radiation dose and patient satisfaction. The target of this study was 79 Male and Female patients who visited genitourinary clinic of PNUYH for their VCUG tests AXIUM Iconos R200(Siemens Medical System : Germany) and self-produced plastic underwears made by vinyl and plasic molding machine were used. The 79 patient were divided into two groups : experiment of patient and comparison group of we patient (using aid) in order to compare, testing time, DAP (dose area product) and patient satisfaction. There was time reduction, from 35.3min of comparison group to 27.8min experimentation group by 7.5min decrease. And comparison group of $4566.6{\mu}Gym^2$(DAP) decreased experimental group (using aid) of $3411.9{\mu}Gym^2$ by $1154.7{\mu}Gym^2$. In the case of patients satisfaction study, anxiety had a drop by 3.45 of comparison group to 2.51 experimentation group by 0.94 decrease. in experimental group. And shame had a drop by 4.02 of comparison group to 3.08 experimentation group by 0.94 increase. in experimental group. Difference of the smooth voiding had a drop by 1.90 of comparison group to 2.84 experimentation group by 0.94 increase. in experimental group. In addition satisfaction had a rise by 1.19 in experimental group. There were also other opinions of uncomfortableness on it and troublesome to wear. VCUG is one of the sensitive care required test. Therefore staff and the aid can give patients such comfortable and the aid can consentive on voiding. As a result test time and DAP can be reduced. It is needed to make testing at more comfortable for patients.

Limited Open Reduction and Internal Fixation of the Tibial Pilon Fractures (제한 절개를 통한 관혈적 정복 및 내고정술을 이용한 경골 Pilon 골절의 치료)

  • Kang, Chung-Nam;Kim, Jong-Oh;Kim, Dong-Wook;Koh, Young-Do;Ko, Sang-Hun;Yoo, Jae-Doo;Hwang, Jun-Ho
    • Journal of Korean Foot and Ankle Society
    • /
    • v.1 no.2
    • /
    • pp.102-111
    • /
    • 1997
  • The tibial Pilon fracture, which is defined as a comminuted intraarticular fracture of the distal tibia, is difficult to manage because high axial compression and rotational forces to the ankle joint result in impaction, severe comminution, metaphyseal disruption and soft tissue damage. There are variable methods of treatment such as manipulation and cast, calcaneal traction and cast, external fixation, pin and plaster, limited open reduction and external fixation, and open reduction and rigid internal fixation. Though most of authors reported better result after a surgical treatment. than that of conservative treatment, many complications such as posttraumatic arthritis and soft tissue problem still remain troublesome. We have reviewed 19 cases of the tibial Pilon fractures in 18 patients which were treated with limited open reduction and internal fixation from September 1993 to May 1996. The results were as follows: 1. The fractures were classified into five types according to the system of Ovadia and Beals, and the most frequent type was type 3 (53%). The most common cause of injury was traffic accident (47%). 2. All of the cases of type 1 and 2, in which the injury of the ankle joint was less severe, revealed good or excellent clinical results. But in type 4 and 5, because the injury is much severe and accurate reduction is difficult, the clinical results were unsatisfaetory. 3. The most frequent complication was posttraumatic osteoarthritis, and which developed in second frequent complication, was developed m the three cases of type 3 in which the radiographic results were less than fair, but there were no correlation with the clinical results. 4. We could markedly reduce the complications related to the soft tissue problem of Pilon fracture by treatment with limited open reduction and internal fixation, and consider that this is a good method of treatment of Pilon fracture when the injury is less severe and accurate reduction is possible.

  • PDF

Evaluation of Temperature and Humidity of a Thermo-Hygrostat of PET/CT Equipment using a Temperature and Humidity Sensor(BME 280) (온·습도센서(BME 280 센서)를 이용한 PET/CT 장비의 항온 항습기 온·습도 평가)

  • Ryu, Chan-Ju;Kim, Jeong-A;Kim, Jun-Su;Yun, Geun-Yeong;Heo, Seung-Hui;Hong, Seong-Jong
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.1
    • /
    • pp.15-22
    • /
    • 2020
  • PET(Positron Emission Tomography) devices are used as PET/CT or PET/MRI devices fused with the devices of CT or MRI for obtaining anatomical information. Therefore, the devices are constructed in circular ring-type structure whose length of gantry(the main part of filming) becomes wider and the interior depth becomes longer in comparison to other common medical equipments. scintillator, one of the components in PET devices, is inside the gantry, and as it is consisted of crystal which is sensitive to the change of temperature and humidity, large temperature change can cause the scintillator to be damaged. Though scintillator located inside the gantry maintains temperature and humidity with a thermo-hygrostat, changes in temperature and humidity are expected due to structural reasons. The output value was measured by dividing the inside of the gantry of the PET/CT device into six zones, each of which an Adafruit BME 280 temperature and humidity sensor was placed at. A thermo-hygrostat keeps the temperature and humidity constant in the PET/CT room. As the measured value of temperature and humidity of the sensor was obtained, the measured value of temperature and humidity appeared in the thermohygrostat was taken at the same time. Comparing the average measured values of temperature and humidity measured at each six zones with the average values of the thermo-hygrostat results in a difference of 2.71℃ in temperature and 21.5% in humidity. The measured temperature and humidity of PET Gantry is out of domestic quality control range. According to the results of the study, if there is continuous change in temperature and humidity in the future, the aging of the scintillator mounted in the PET Gantry is expected to be aging, so it is necessary to find a way to properly maintain the temperature and humidity inside the Gantry structure.

Comparison of the Quality of Gamma Ray- or Electron Beam-irradiated Minced Pork and Pork Patties (감마선 또는 전자선 조사된 분쇄돈육과 돈육패티의 저장 중 품질특성 비교)

  • Song, Beom-Seok;Park, Jin-Gyu;Kim, Wang-Geun;Kim, Jae-Hun;Choi, Jong-Il;Yoon, Yo-Han;Byun, Myung-Woo;Kim, Cheon-Jei;Lee, Ju-Woon
    • Food Science of Animal Resources
    • /
    • v.29 no.2
    • /
    • pp.194-202
    • /
    • 2009
  • This study was conducted to determine the effects of gamma and e-beam irradiation on the quality of minced pork and pork patties. Each sample was irradiated at 5 to 20kGy, and its quality characteristics were then evaluated during storage at 30. The results of the total bacterial populations in the minced-pork and pork patty samples showed that the antimicrobial effect of gamma irradiation was superior to that of e-beam irradiation. The 2-thiobarbituric acid reactive substances (TBARS) value of all the samples significantly increased (p<0.05) as the irradiation dose and storage period increased. In addition, the gamma-irradiated (GI) samples had higher (p<0.05) TBARS values than the e-beam-irradiated (EI) samples. The volatile basic nitrogen contents of the GI samples were lower (p<0.05) than those of the EI samples. The color values, such as the $L^*$(brightness), $a^*$(redness), and $b^*$(yellowness) of the minced pork and pork patties, were increased (p<0.05) by irradiation. The hardness and sensory properties, such as the color, chewiness, taste, and overall acceptability of the pork patties, were decreased when the irradiation dose increased, and the hardness and sensory scores of the GI samples were lower than those of the EI samples.

Improvement of Diagnostic Accuracy by Standardization in Diuretic Renal Scan (소아 이뇨 신장스캔에서 검사 표준화에 의한 폐쇄 진단 성능 향상)

  • Hyun, In-Young;Lee, Dong-Soo;Lee, Kyung-Han;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon;Kim, Kwang-Myung;Choi, Hwang;Choi, Yong
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.4
    • /
    • pp.497-503
    • /
    • 1995
  • We evaluated diagnostic accuracy of diuretic renal scan with standardization in 45 childrens(107 hydronephrotic kidneys) with 91 diuretic assessments. Sensitivity was 100%, specificity was 78%, and accuracy was 84% in 49 hydronephrotic kidneys with standardization. Diuretic renal scan without standardization, sensitivity was 100%, specificity was 38%, and accuracy was 57 % in 58 hydronephrotic kidneys. The false-positive results were observed in 25 cases without standardization, and in 8 cases with standardization. In diuretic renal scans without standardization, the causes of false-positive results were 10 early injection of lasix before mixing of radioactivity in pelvocalyceal system, 4 full bladder, 2 markedly dilated pelvocalyceal systems postpyeloplsty, 6 extrarenal pelvis, and 3 immature kidneys of neonates. In diuretic renal scans with standardization the causes of false-positive results were 2 markedly dilated systems postpyeloplsty, 2 extrarenal pelvis, 1 immature kidney of neonate, and 2 severe venal dysfunction, 1 vesicoureteral reflux. In diuretic renal scan without standardization the false-positive results by inadequate study were common, but false-positive results by inadequate study were not found after standardization. The false-positive results by dilated pelvocalyceal systems postpyeloplsty, extrarenal pelvis, and immature kidneys of neonates were not dissolved after standardization. In conclusion, diagnostic accuracy of diuretic renal scan with standardization was useful in children with renal outflow tract obstruction by improving specificity significantly.

  • PDF

Influence of Ischemic Lesions on $^{99m}Tc$-HMPAO SPECT Findings in the Diagnosis of Alzheimer's Disease ($^{99m}Tc$-HMPAO SPECT를 이용한 알쯔하이머병의 진단에서 허혈성 뇌병변이 미치는 영향)

  • Lee, Kyung-Han;Lee, Myung-Chul;Lee, Dong-Soo;Kwon, June-Soo;Kim, Jong-Ho;Chung, June-Key;Woo, Jong-In;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.3
    • /
    • pp.282-292
    • /
    • 1994
  • Brain perfusion SPECT shows typical regional perfusion abnormalities in Alzheimer's disease(AD) and is useful for its diagnosis. However, there is also arguement that these patterns show significant overlap with other causes, and the accuracy for SPECT in differentiating AD has shown conflicting results. We postulate that the variation in re-ported results are partly due to a difference in patient or control selection with special reference to the mixture of ischemic cerebral disease in the studied population. To deter-mine the effect of ischemic lesions and the nature of control subjects on SPECT studies for AD, we performed $^{99m}Tc$-HMPAO single photon emission computed tomography (SPECT) in 11 probable AD patients with a low (<4) Hachinski ischemic score and 12 non-demented age matched controls. Magnetic resonance imaging(MRI) disclosed ischemic cerebral lesions in 27% (3/11) of the PAD group and 25% (3/12) of the control group. Regional perfusion indices were quantitated from the SPECT images as follows and the distribution of perfusion indices from both groups were compared. This was repeated with controls after excluding those with significant ischemic lesions by MRI : regional perfusion index = average regional count/average cerebellar count All PAD patients showed perfusion abnormality in SPECT. However, 53% (10/12) of controls also showed perfusion at-normalities, and no pattern could reliably differentiate the two groups. After excluding controls with significant cerebral ischemia, the difference in temporal and parietal perfusion index was increased. A decreased tempore-parietal and any parietal or temporal per-fusion index had a sensitivity of 18% and 36% in detecting AD, respectively. When using a separate group of normal age mathced controls, the indices showed an even more difference in the temporal and parietal lobes and the sensitivity of a decreased tempore-parietal and any parietal or temporal perfusion index had a sensitivity of 36% and 55% in detecting AD, respectively. Thus, the type of control with special reference to the pres-once of ischemic cerebral lesions contribute significantly to the accuracy of perfusion SPECT in diagnosing AD. This nay have particular importance in the diagnosis of AD in populations where the prevalance of cerebrovascular disease is high.

  • PDF

Nontuberculous Mycobacterial pulmonary Infection in Immunocompetent Patients (면역적격자에서 비결핵마이코박테리아의 폐감염)

  • Lee, Hyo-Won;Kim, Mi-Na;Shim, Tae-Sun;Bai, Gill-Han;Pai, Chik-Hyun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.2
    • /
    • pp.173-182
    • /
    • 2002
  • Background : Nontuberculous mycobacteria (NTM) have usually been considered to be contaminants of colonizers when isolated from respiratory specimens in Korea, where there is a high prevalence of tuberculosis and a low rate of HIV infections. Therefore, there has been few studies on the clinical significance of NTM species in immunocompetent patients were investigated. Methods : Thirty-five NTM isolates, for which species identification was requested by the treating physicians during 1999 at the Asan Medical Center, were retrospectively analyzed. They were identified to the species level by mycolic acid analysis using high-performance liquid chromatography. The medical records of the patients with the NTM isolates were reviewed to identify those patients who met the American Thoracic Society (ATS)'s criteria for mycobacterial pulmonary infection. Their antimicrobial susceptibility data were compared with the clinical outcomes. Results : The NTM were identified as M. intracellulare (6 isolates), M. avium (5), M. abscessus (5), M. gordonae (5), M. terrae complex (4), M. szulgai (2), M. kansasii (2), M. fortuitum (2), M. peregrinum (1), M. mucogenicum (1), M. celatum (1), and M. chelonae (1). All 35 patients showed clinical symptoms and signs of chronic lung disease, but none had a HIV infections; 16 (45.7%) patients were found to be compatible with a NTM pulmonary infection according to the ATS criteria, 5 and 4 cases were affected with M. intracellulare and M. abscessus, respectively; 8 patients had a history of pulmonary tuberculosis. 13 patients received antimycobacterial therapy for an average of 21 months and 9 patients were treated with second-line drugs. Only 4 patients had improved radiologically. Conclusion : A NTM should be considered a potential pathogen of pulmonary infections in immunocompetent patients with chronic pulmonary diseases. Most NTM infections were left untreated for a prolonged period and showed a poor outcome as a result, M. intracellulare and M. abscessus were the two most frequent causes of NTM pulmonary infections in this study. Species identification and antimycobacterial susceptibility tests based on the species are needed for the optimum management of a NTM pulmonary infection in patients.

Pelvic MRI Application to the Dosimetric Analysis in Brachytherapy of Uterine Cervix Carcinoma (자궁경부암의 강내조사치료에 있어서 흠수선량평가시 골반강 자기공명사진의 응용)

  • Chung, Woong-Ki;Nah, Byung-Sik;Ahn, Sung-Ja
    • Radiation Oncology Journal
    • /
    • v.15 no.1
    • /
    • pp.57-64
    • /
    • 1997
  • Purpose : Before we report the results of curative radiotherapy in cervix cancer patients, we review the significance and safety of our dose specification methods in the brachytherapy system to have the insight of the potential Predictive value of doses at specified points. Matersials and Methods : We analyze the 리5 cases of cervix cancer patients treated with intracavitary brachytherapy in the lateral simulation film we draw the isodose curve and observe the absorbed dose rate of point A, the reference point of bladder(SBD) and rectum(SRD). In the sagittal view of Pelvic MRI film we demarcate the tumor volume(TV) and determine whether the prescription dose curve of point A covers the tumor volume adequately by drawing the isodose curve as correctly as possible. Also we estimate the maximum Point dose of bladder(MBD) and rectum(MRD) and calculate the inclusion area where the absorbed dose rate is higher than that of point A in the bladder(HBV) and rectum(HRV), respectively. Results : Of forty-five cases, the isodose curve of point A seems to cover tumor volume optimally in only 24(53%). The optimal tumor coverage seems to be associated not with the stage of the disease but with the tumor volume. There is no statistically significant association between SBD/SRD and MBD/MRD, respectively. SRD has statistically marginally significant association with HRV, while TV has statistically significant association with HBV and HRV. Conclusion : Our current treatment calculation methods seem to have the defect in the aspects of the nonoptimal coverage of the bulky tumor and the inappropriate estimation of bladder dose. We therefore need to modify the applicator geometry to optimize the dose distribution at the position of lower tandem source. Also it appears that the position of the bladder in relation to the applicators needs to be defined individually to define 'hot spots'.

  • PDF

EFFECT OF DECALCIFIED FREEZE-DRIED ALLOGENEIC BONE GRAFT(DFDB) ON THE JAW DEFECTS AFTER CYST ENUCLEATION (낭종 적출후 악골 결손부 치유에 관한 동종골 이식 효과에 관한 연구)

  • Lee, Dong-Keun;Min, Seung-Ki;Kwon, Kyung-Hwan;Sung, Hun-Mo;Park, Hwa-Kyu;Kang, Mun-Jeong;Sin, Ki-Young
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.21 no.4
    • /
    • pp.360-365
    • /
    • 1999
  • This study was aimed to suggest to better treatment method of jaw cyst that the maximum diameter was wider than 3cm, using different treatment and clinical and radiographic result. We divided the 60 patients into three groups, group A(20 patients) were treated with cyst enucleation and Decalcified Freeze-Dried Allogeneic Bone(DFDB) graft, group B(20 patients) were treated with cyst enucleation and autogenous bone graft, group C(20 patients) were treated with only cyst enucleation. Each group was evaluated with panoramic radiograph and clinical sign & symptom at pre-op and post-op(immediate, 6, 12, 24, 36 month). Bone density was evaluated with disital densitometer. The result was as follows : 1. Post-Op infection was higher in group C(4 pts.) than in group A(1 pt.) and B(1 pt.) 2. Post-Op gingival recession was higher in group C(3 Pts.) than in group A(1 pt.) and B(1 pt.) 3. Anatomic distortion was higher in group C(3 Pt.) than in group A(1 Pt.), and B(1 pt.) 4. Reoperation was done in two patients who were in group C 5. There were donor site morbidity in two patients 6. There was no significant difference between group A and B in their bony density in their follow up period(p>0.05). 7. There were significant differences between group A, B and group C in their bony density until post-op 24 months but a little differences at post-op 36 months(P<0.01)

  • PDF