• Title/Summary/Keyword: 방사선사진

Search Result 1,111, Processing Time 0.033 seconds

Development of Immobilization Devices for Patients with Pelvic Malignancies and a Feasibility Evaluation during Radiotherapy (골반부 암 환자를 위한 고정기구 개발 및 방사선치료 시 효용성 평가)

  • Park, Jong-Min;Park, Yang-Kyun;Cho, Woong;Park, Charn-Il;Ha, Sung-Whan
    • Radiation Oncology Journal
    • /
    • v.25 no.2
    • /
    • pp.134-144
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: Immobilization devices that improve the setup reproducibility of pelvic cancer patients and that provide comfort to patients during radiotherapy were designed and the feasibility of the devices was evaluated. $\underline{Materials\;and\;Methods}$: A customized device was designed to immobilize a knee, thigh, and foot of a patient. Sixty-one patients with prostate cancer were selected and were divided into two groups-with or without devices. The setup errors were measured with respect to bony landmarks. The difference between digitally reconstructed radiographs (DRR) and simulation films, and the differences between DRR and portal films were measured. $\underline{Results}$: The left-right (LR), anterior-posterior (AP) and craniocaudal (CC) errors between the DRR and simulation films were $1.5{\pm}0.9\;mm$, $3.0{\pm}3.6\;mm$, and $1.6{\pm}0.9\;mm$, respectively without devices. The errors were reduced to $1.3{\pm}1.9\;mm$, $1.8{\pm}1.5\;mm$ and $1.1{\pm}1.1\;mm$, respectively with the devices. The errors between DRR and portal films were $1.6{\pm}1.2\;mm$, $4.0{\pm}4.1\;mm$, and $4.2{\pm}5.5\;mm$, respectively without the devices and were reduced to $1.0{\pm}1.8\;mm$, $1.2{\pm}0.9\;mm$, and $1.2{\pm}0.8\;mm$, respectively, with the devices. The standard deviations among the portal films were 1.1 mm, 2.1 mm, and 1.0 mm at each axis without the devices and 0.9 mm, 1.6 mm and 0.8 mm with the devices. The percentage of setup errors larger than 3 mm and 5 mm were significantly reduced by use of the immobilization devices. $\underline{Conclusion}$: The designed devices improved the setup reproducibility for all three directions and significantly reduced critical setup errors.

Study on the Manufacturing of Horizontal plate armour Excavated from Mangi-Sanseong(Castle) with X-ray Radiograph (방사선투과시험에 의한 망이산성 횡장판갑(橫長板甲)의 제작기법 연구)

  • Kim, Hyunjoung;Kim, Midori;Oh, Kwangseob;Lee, Yangsu;Cho, Namchul
    • Conservation Science in Museum
    • /
    • v.7
    • /
    • pp.11-24
    • /
    • 2006
  • Plate armour is an important cultural property that reflects the ancient weaponry and the manufacturing technology of ironware as they are. Among the kinds of iron armour, horizontal plate armour has been very rarely excavated, and there are a few artifacts in their unimpaired shape like the plate armour excavated from Mangisanseong. This report reviews the manufacturing technology of ancient plate armour through its radiograph using appliable nondestructive irradiation and scientific conservation treatment. The seven-tiered plate armour excavated from Mangisanseong has ring hinge to open and shut the right side neck guard. The readout result of radiograph proved iron safety guard of Godaepan (a plate that links neck plate and horizontal plate) and leather safety guard of the right armpit with plate overlap and perforation interval; perforations that seem to have linked shoulder strap on wearing the armour are also observed. In particular, it is identified that the perforation and riveting technique avoided the connection of more than three plates with a rivet. This is an important material to illustrate the best use of function of plate armour overcoming its limit.

Correlation Between Degree of Torn Rotator Cuff in MRI and Degenerative Change of Acromion and Greater Tuberosity in Simple Radiography (단순 방사선 사진에서 견봉 및 상완골 대결절의 퇴행성 변화와 MRI상 회전근 개 파열 정도와의 연관성)

  • Choi, Jung-Yun;Yum, Jae-Kwang;Song, Min-Cheol
    • Clinics in Shoulder and Elbow
    • /
    • v.16 no.1
    • /
    • pp.1-9
    • /
    • 2013
  • Purpose: The purpose of this study is to analyze the correlation between the degree of torn rotator cuff as recorded by MRI and degenerative change of acromion and greater tuberosity of humerus determined by simple radiographs. Materials and Methods: Of the 518 cases included in this study, a group of 234 cases had a chronic rotator cuff tear and a control group of 284 cases had an intact rotator cuff in shoulder MRI. The degree of degenerative changes was classified according to the length of spur and morphological change of acromion and greater tuberosity through the true anteroposterior simple radiograph in supraspinatus outlet view. The degree of tear (partial-thickness or full-thickness tear) and the size of complete rotator cuff tear were analyzed according to the MRI findings of shoulder. The authors also evaluated the correlation between the degree and size of torn rotator cuff and the degenerative change of acromion and greater tuberosity. Results: There were significant differences in the size and extent of torn rotator cuff according to the age, sex and degenerative change of acromion and greater tuberosity of humerus (p<0.001). More degenerative changes of acromion and greater tuberosity in simple shoulder radiographs showed the increased degree and size of torn rotator cuff (p<0.001). In addition, the higher degree and larger size of torn rotator cuff were noted in older age subjects (p<0.001) and in the female group (p<0.001). Conclusion: More degenerative changes of acromion and greater tuberosity in simple shoulder radiographs showed the increased degree and size of torn rotator cuff. Therefore, if a high degree of degenerative change of the acromion and greater tuberosity on simple radiograph is noted, the possibility of degenerative rotator cuff tear should be considered. In addition, the age and sex could be associative factors for larger size of torn rotator cuff.

Widening of Bony Tunnel after ACL Reconstruction Using Hamstring Tendon with Ligament Anchor(LA) Screw (슬괵건 및 LA나사를 이용한 관절경적 전방 십자 인대 재건술 후 골터널의 확장)

  • Song Eun Kyoo;Yoon Taek Rim;Jung Jong Wook;Jeong Kwang Cheul
    • Journal of the Korean Arthroscopy Society
    • /
    • v.5 no.2
    • /
    • pp.69-73
    • /
    • 2001
  • Purpose : To evaluate the clinical results and widening of bony tunnel after anterior cruciate ligament(ACL) reconstruction using hamstring tendon with Ligament Anchor(LA) screw, which is newly designed fur fixation of graft into femur. Materials and Methods : Fifty eight patients who were followed up at least more than 2 years after ACL reconstruction with four strands of Hamstring tendon were included in this study. The graft was fixed with LA screw at femoral tunnel and with bioabsorbable interference screw at tibial tunnel. The average period of follow-up was 28 months. The clinical results such as physical examination and Lysholm knee score and radiological results. widening of bony tunnel and instrumented anterior laxity test with $Telos^{\circledR}$(Telos stress device; Austin & Associates, Inc., Polston, US) were evaluated. Results . The Lysholm knee score was 60.0 in average preoperatively and improved to 94.0 in average at follow up. On the Lachman test, there were mild(+) instability in 16 cases, moderate(++) in 24, severe(+++) in 18 preoperatively. 50 cases were converted to negative and 8 to mild instability at follow up. On instrumented anterior laxity test with $Telos^{\circledR}$, side to side difference in 20 lb was 12.9mm in average preoperatively, and was decreased to 3.1mm in average follow-up. The femoral tunnel was widened from 10.6mm postoperatively to 12.7mm$(21.1\%)$ at follow up on antero-posterior plane and from 10.7mm to 12.4mm$(16.5\%)$ on lateral plane. Tibial tunnels was also widened from 9.8mm to 11.8mm$(20.7\%)$ on antero-posterior plane and from 9.9mm to 11.7mm$(18.9\%)$ in lateral plane. Conclusion : ACL reconstruction with hamstring tendon and LA screw was one of the choice of grafts and fixatives in restoring knee stability and in improving clinical results with little complications such as excessive widening of bony tunnel.

  • PDF

Evaluation of Cancer Detection Efficiency by Means of Hybrid and Inverse Filter in Chest Radiography (디지털 흉부 방사선 영상에서 Hybrid Filter와 Inverse Filter를 적용한 종양의 검출능 평가)

  • Kim, Youn-Young;Kim, Tae-Young;Kim, Hyun-Ji;Park, Min-Seock;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.36 no.4
    • /
    • pp.319-326
    • /
    • 2013
  • The purpose of this study is to evaluate usefulness of Hybrid image and Inverse image about detection of tumor shadow in chest radiography using ROC analysis. Original images of 60 cases are selected from Standards digital image date base issued by the Japanese Society of Radiological Technology. Through computer language of C, Inverse images of 60 cases and Hybrid image of 30 cases are made. The continues reading experiment was conducted. In the case of inverse image were observed by 5 radiographer and 2 radiologist. In the case of In case of Hybrid image were observed by 3 student radiographer and 2 experienced radiographer. ROC curve are constructed using ROCKIT Program made by Metz. In Inverse image, a Az of average ROC curve was increases from 0.742 of original image to 0.775 of inverse image. In normal cases, the effect of the detrimental is same to that of the beneficial, however In abnormal cases, the beneficial effect is greater than detrimental effect. However in Hybrid image, a Az of average ROC curve was decreases from 0.5253 of original image to 0.4868 of Hybrid image. In Normal cases, the effect of the detrimental is greater than that of the Beneficial, however In abnormal cases, the Beneficial effect is greater than detrimental effect. The inverse image can be more positively considered for the detecting of tumor than the hybrid image.

Quantification of Experimentally Induced-Pleural Effusion in Beagle Dogs: Radiography versus CT and Ultrasonography (비글견에서 실험적으로 유발한 흉수의 정량 평가: 방사선, 컴퓨터단층촬영 및 초음파 검사 비교)

  • Lee, Ki-Ja;O, I-Se;Jeong, Seong-Mok;Lee, Hee-Chun;Park, Seong-Jun;Lee, Young-Won;Choi, Ho-Jung
    • Journal of Veterinary Clinics
    • /
    • v.25 no.2
    • /
    • pp.96-101
    • /
    • 2008
  • This study was performed to quantify the pleural effusion in radiography, ultrasonography and computed tomography(CT) and to evaluate and compare the usefulness of these methods. Normal saline of 10 ml/kg was infused into the pleural space until a final loading volume of 60 ml/kg body weight was reached in six Beagle dogs. The radiographic examination was performed for the detection and quantification of pleural effusion. On the ultrasonographic study, the maximum perpendicular distance was measured between the surface of the lung and the thoracic wall to evaluate pleural effusion. On the CT image, pleural effusion was evaluated as the perpendicular distance to the thoracic surface in the maximum pleural effusion volume on any transverse images with soft tissue window. Statistical analysis was performed using linear regression test. The volume of pleural effusion and measurements of radiography and ultrasonography had no statistical relationship. However, a significant correlation was identified between the volume of pleural effusion and the depth at right ($r^2=0.715$), left ($r^2=0.745$), and mean right and left depth ($r^2=0.844$) on the CT images. All of the thoracic radiographs, ultrasonography, and CT are useful in recognition of pleural effusion. In quantification of pleural effusion, the CT measurement method is superior to radiographic and ultrasonographic measurements.

Reproducibility and reliability of head posture obtained by the outer canthus indicator (Outer Canthus Indicator를 이용한 두부 자세 기록법의 재현성)

  • Kim, Young-Jae;Sohn, Byong-Wha;Lee, Kee-Joon
    • The korean journal of orthodontics
    • /
    • v.40 no.2
    • /
    • pp.77-86
    • /
    • 2010
  • Objective: The purposes of this study were to evaluate the reproducibility and reliability of head posture obtained by registering outer canthus as a soft tissue landmark with the Outer Canthus Indicator (OCI). Methods: Twenty-one adults with normal facial morphology were enrolled in this study (mean age $27.5\;{\pm}\;1.72$ years). To register initial head posture, height of the outer canthus from the ear rod plane was measured using OCI. Head posture was reproduced by moving the head upwards and downwards until the outer canthus was in a straight line with the indicator set at a registered height. After the head posture is reproduced by two operators after two days, lateral photographs were taken. Computerized photometric analyses of the photographs were performed. Results: The head rotations around the transverse axis were $0.69\;{\pm}\;0.43^{\circ}$, $0.98\;{\pm}\;0.65^{\circ}$ from each of the two operators. Standard errors were $0.09^{\circ}$ and $0.14^{\circ}$ each, which were similar to results from past research findings. There were no significant differences between the data from the two operators (p > 0.05). There were no correlations between the head rotation around the horizontal and vertical axes (p > 0.05). Conclusions: The present study suggests that OCI-registered head posture may minimize errors from vertical head rotation in cephalometry and photometry.