• Title/Summary/Keyword: 방사선멸균

Search Result 54, Processing Time 0.028 seconds

A Retrospective Study of Critical Success Factors in Regenerative Endodontic Treatment (재생근관치료의 성공에 영향을 미치는 결정 요인에 대한 후향적 연구)

  • Jeong, Hwakyong;Lee, Nanyoung;Lee, Sangho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.44 no.1
    • /
    • pp.47-55
    • /
    • 2017
  • This study evaluated critical factors influencing the success of regenerative endodontic treatment for necrotic immature permanent teeth. The study enrolled patients who had regenerative endodontic treatment in a necrotic immature permanent tooth through 1-year follow-up. Possible explanatory variables related to the success rates for 46 teeth were age, gender, dental stage at the initial appointment, etiology, treatment information, and clinical and radiographic outcomes. The dental stage at the time of regenerative endodontic treatment did not influence the success rate. The success rate was significantly related to the etiology of the necrotic immature tooth. The success rate according to etiology decreased in the following order: dens evaginatus, caries, and trauma. There was also a significant difference according to the type of antimicrobial. The success rate was influenced by appropriate disinfection of the root canal system, provision of a scaffold, and coronal sealing. Above all, careful case selection is necessary for treating a necrotic immature permanent tooth, especially in cases of trauma.

AN EXPERIMENTAL STUDY ON TISSUE RESPONSE FOLLOWING IMPLANTATION OF THE FREEZE - DRIED AND RADIATION - STERILIZED ALLOGENEIC BONE IN RECTUS ABDOMINICUS MUSCLE (백서 복근에 매식된 동결 건조 및 방사선 멸균처리된 동종골의 조직 반응에 관한 실험적 연구)

  • Lee, Chang-Woo;Yim, Chang-Joon;Lee, Dong-Kuen;Kim, Soo-Nam
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.13 no.3
    • /
    • pp.265-277
    • /
    • 1991
  • In this study, the healing changes of the implanted bone and its surrounding tissues were examined on the histopathologic basis following implantation of the freeze - dried and radiation - sterilized allogeneic bone in Rectus abdominicus of the rat. This study was performed to see the tissue recations after implantation of the freeze - dried and radiation - sterilized allogeneic bone and whether osteogenesis or osteo - induction or osteo - conduction is happened. And the results were as follows : 1. The shape of the implanted allogeneic bone of the 1, 2 - week group specimen was similar to that of normal bone in light - microscopic finding and the atrophy of cellular organells was found in trans - mission electron - microscopic finding. 2. The implanted allogeneic bone was surrounded with the dense fibroconnective tissues, and infiltration of the chronic inflammatory cells gradually became increased. 3. Hyaline degeneration was observed in the surrounding tissue at the 3, 4, 6 - week group specimen. 4. Light - microscopically the resorption of implanted bone became prominent after 4 - week group and the necrosis of allogeneic bone implant became severe with loss of cell components in lacuna. 5. Electron - microscopically, the osteoclast - like cells ere fond after, 2 - week group. It is summarized that the osteo - conduction potential of the bone is remained just after implanting the freeze - dried and radiation - sterilized allogeneic bone on Rectus abdominicus of the rat, but gradually it disappeared with the gradual increse of chronic inflammatory reaction and osteoclastic activity. So it is suggested that the antigenicity of the freeze - dried and radiation - sterilized bone is remained and it has little osteo - conductive activity when it is implanted in the muscle.

  • PDF

THE EFFECT OF STERILIZATION OF GAMMA IRRADIATION ON ALLOGENEIC TISSUE MATERIALS (동종조직에서의 방사선 멸균효과에 대한 연구)

  • Lee, Eun-Young;Kim, Sung-Jin;Park, Woo-Yoon;Kim, Kyoung-Won;Um, In-Woong;Ryu, Ju-Youn
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.27 no.6
    • /
    • pp.523-527
    • /
    • 2005
  • Allograft donations are commonly found to be contaminated. The most of tissue banks has promoted the use of ionizing radiation for the sterilization of biological tissues. The potential for transmission of human infectious diseases and contamination of microorganism has created serious concern for the continued clinical use of hard and soft-tissue allografts. Tissue banks have employed 15-25kGy for sterilization of hard and tendon allografts, which, according to the national standards, approaches the level at which the tissue quality is adversely affected for transplantation. The donations of allogeneic tissues to the Korea Tissue Bank over a 2-year period were reviewed, and the incidence and bacteriology of contamination were detailed. Clinical outcomes were determined for donors who had positive cultures at the time of retrieval and during the processing and they were compared with those of post sterilization. After exposure of the frozen block bone to 25kGy and the processed tissues to 15kGy of gamma irradiation, the authors were able to demonstrate complete inactivation of the bacteria. The aim of this study was to obtain the effects of gamma irradiation and the irradiation dose according to the type of tissue, through conventional microbiologic test without on influence of biocompatibility in allografts. The contamination rate after the final irradiation sterilization is 0% in the processed allografts. This may be due to the fact that the gamma radiation and processing steps are effective to control contamination.

Radio-sensitivity of Contaminated Pathogens in Marinated Beef Rib (Galbi) Treated with ${\gamma}-Irradiation$ and Its Sensory Properties (시판 양념갈비에 오염된 병원성 미생물의 감마선 감수성 및 감마선 조사된 갈비의 관능적 품질특성)

  • Lee, Na-Young;Cho, Cheo-Hoon;Kang, Ho-Jin;Kim, Dong-Soo;Byun, Myung-Woo
    • Korean Journal of Food Science and Technology
    • /
    • v.36 no.1
    • /
    • pp.168-173
    • /
    • 2004
  • Radio-sensitivity of pathogens in commercial marinated beef ribs, Galbi, and effect of irradiation on microbiological safety and sensory properties of marinated beef rib were investigated. Commercial raw marinated beef ribs were highly contaminated by pathogenic microorganisms including Bacillus cereus, Salmonella typhimurium, Escherichia coli, and Staphylococcus aureus, ranged from $10^{3}\;to\;10^{4}\;CFU/g$. Gamma irradiation reduced pathogen count during storage. No viable cells of pathogens were observed in sample irradiated at 7.5 kGy except for Bacillus cereus. Radio-sensitivity of inoculated pathogens in marinated beef ribs and commercial one showed $D_{10}$ value of 0.54-0.60 and 2.15-2.98, respectively, In sensory evaluation irradiated sample showed highest color and overall acceptance among treatments (p<0.05). Results indicate low dose (2.5-5.0 kGy) irradiation is effective for ensuring safety of marinated beef ribs without decreasing sensory quality.

A Convergence Study on the Contamination and Disinfection of General X-ray generator Practical Equipment (일반촬영 실습 장비의 오염 및 소독에 관한 융합적 연구)

  • Park, Gyu-Tae;Kim, Dong-Heun;Park, Sang-Hee;Jung, Won-Hee;Kim, So-Yeon;Hong, Hee-Jin;Son, Na-Ra;Nam, Seoul-Hee;Han, Man-Seok
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.1
    • /
    • pp.51-56
    • /
    • 2020
  • It is going to select one X-ray generating device for diagnosis in a radiography laboratory at K university in Gangwon-do to detect bacteria on the surface contamination of tables, IP cassettes, and lead gowns for medical radiation shielding and to inform students of the need for proper disinfection control and hand hygiene. Then disinfection was carried out with tissue, tissue cleaner and 70% alchol and immediately collected with sterile cotton swabs to assess the contamination distribution status and disinfection effects of the surface. The results of measuring the degree of contamination on the surface showed that the largest number of bacteria were detected in Apron, and the evaluation of the disinfection effects according to surface contamination showed a noticeable effect at 70% Alcohol in IP Cassette, and the disinfection effect was the same for Apron. Therefore, in order to prevent bacterial infections among students, basic hand washing and regular disinfection should be performed before the practice to prevent infection.

A Comparative Study of Production of [68Ga]PSMA-11 with or without Cassette Type Modules (비 카세트 방식과 카세트 방식을 이용한 [68Ga]PSMA-11의 자동 합성 방법 비교)

  • Hyun-Sik, Park;Byeong-Min, Jo;Hyun-Ho, An;Hong-Jin, Lee;Jin-Hyeong, Lee;Gyeong-Jae, Lee;Byung-Chul, Lee;Won-Woo, Lee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.2
    • /
    • pp.15-19
    • /
    • 2022
  • Purpose [68Ga]PSMA-11 is needed the high reproducibility, excellent radiochemical yield and purity. In term of radiation safety, the radiation exposure of operator for its production also should be considered. In this work, we performed a comparative study for the fully automated synthesis of [68Ga]PSMA-11 between non-cassette type and cassette type. Materials and Methods Two different type of modules (TRACERlab FX N pro for non-cassette type and BIKBox for cassette type) were used for the automated production of [68Ga]PSMA-11. According to the previously identified elution profile, Only 2.5 ml with high radioactivity was used for the reaction. After adjusting the pH of the reaction solution with HEPES buffer solution, the precursor was added and reacted with at 95 ℃ for 15 minutes. The reaction mixture was separated and purified using a C18 light cartridge. The product was eluted with 50% EtOH/saline solution and diluted with saline. It was completed by sterilizing filter. In the non-cassette type, the aforementioned process must be prepared directly. However, in the cassette method, synthesis was possible simply by installing a kit that was already completed. Results Both total [68Ga]PSMA-11 production time were 25±3(non-cassette type) and 23±3 minutes(cassette type). The radiochemical yield of the non-cassette type(65.5±5.7%) was higher than that of the cassette type(61.6±4.8%) after sterilization filter. The non-cassette type took about 120 minutes of preparation time before synthesis due to washing of synthesizer and reagent preparation. However, since the cassette type does not require washing and reagent preparation, it took about 20 minutes to prepare before synthesis. Both type of synthesizer had a radiochemical high purity(>99%). Conclusion The non-cassette type production of [68Ga]PSMA-11 showed higher radiochemical yield and lower cost than the cassette type. However, The cassette type has an advantage in terms of preparation time, convenience, and equipment maintenance.

Surgical Treatment of Metastatic Tumor in Pelvis (골반부 전이성 종양의 수술적 치료)

  • Kim, Jae-Do;Park, Woong;Jo, Myung-Rae;Son, Jung-Whan;Lee, Young-Gu
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.10 no.2
    • /
    • pp.61-70
    • /
    • 2004
  • Purpose: We studied to decide the operative indication of the metastatic tumor in pelvis according to the oncologic results, the Eastern Cooperative Oncologic Group (ECOG) performance status and complication. Materials and methods: From May 1994 to May 2003, 9 patients who were performed on palliative treatment and 10 paitents on operative treatment due to metastatic tumor of pelvic bone were investigated. On palliative/operative group, the mean age of patients was 57.6/48.0 years old and the ratio of male to female was 5:4/7:3. Primary origins were 3 cases from kidney, 3 from cervix and 2 of lung, 2 of myeloma, 2 of Non-Hodgkin's Lymphoma, and 1 from breast, bladder, testis, prostate, stomach, liver and retroperitoneal leimyosarcoma respectively. The palliative treatment was performed in 5 cases with radiotherapy, 1 with chemotherapy, 2 with combined chemo-radiotherapy and 1 with percutaneous cementation. The operative methods were 1 case of bone cement insertion after curettage, 2 of Girdlestone with internal hemipelvectomy and 7 of reconstruction after wide excision. Reconstructions were done.: 1 case of bone cementation, 5 of autograft prosthesis composite with irradiation or pastuerization and 1 of saddle prosthesis. We have observed the oncologic results, the ECOG performance status and complication. Results: The oncologic results of palliative/operative groups are NED 0/1, AWD 2/6, DOC 1/2 and DOD 6/1. The ECOG performance status was changed from 1.5 into 4.3 in palliative group and from 2.6 into 2.2 in operative group. The complications were 3 cases of the prosthesis failure and 2 of infection. Conclusion: The indication of operation of metastatic pelvic tumor is decided in consideration of the patient's condition, the grade of malignancy in primary tumor and the life expectancy.

  • PDF

Effects of ionizing and ultraviolet radiation on microbial mutation and DNA damage (전리방사선 및 자외선의 미생물 돌연변이와 DNA 손상에 대한 영향)

  • Nam, Ji-Hyun;Shin, Ji-Hye;Lee, Jung-Yun;Lee, Dong-Hun
    • Korean Journal of Microbiology
    • /
    • v.53 no.1
    • /
    • pp.20-28
    • /
    • 2017
  • Physical sterilization methods using ultraviolet radiation and ionizing radiation such as gamma ray and electron beam are applied in various industry fields due to disinfection effects and economic efficiency but may also cause microbial mutation. In this research, Salmonella enterica and Escherichia coli strains were treated with ionizing and ultraviolet radiation and their survival rate, mutation rate, and DNA damage were studied to evaluate the genetic safety. The survival rate of the strains decreased drastically as the irradiation dose of ultraviolet ray, gamma ray, and electron beam increased, and over 90% of the strain was exterminated at a dosage of $0.40{\sim}25.06mJ/cm^3$, 0.11~0.22 kGy, 0.14~0.53 kGy respectively. In SOS / umu-test, genotoxicity causing DNA damage was identified in all samples. In Ames test, back-mutation rate increased to $3.82{\times}10^{-4}$ and $9.84{\times}10^{-6}$ respectively when exposed to ultraviolet ray and gamma ray. At exposure to ultraviolet ray, gamma ray, and electron beam with dosage of over 99.99% extinction rate of S. enterica TA100, back-mutation rate increased 347 times, 220 times, 0.6 times respectively to the spontaneous back-mutation rate. Rifampicin resistance mutation rate of E. coli CSH100 exposed to ultraviolet ray, gamma ray, and electron beam was $2.46{\times}10^{-6}$, $1.66{\times}10^{-6}$, $4.12{\times}10^{-7}$ respectively. Therefore, gamma radiation is effective in microorganism control from the perspective of disinfection and electron beam has the advantage of sterilizing with little DNA damage and bacterial mutation.

Effects of High Hydrostatic Pressure and Gamma Irradiation on Quality and Microbiological Changes of Kochujang-Gulbi. (고추장굴비의 품질과 저장성에 미치는 초고압처리와 감마선 조사 효과)

  • Kang, Seong-Gook;Park, Nan-Hee;Ko, Do-Ock;Li, Jing-Lei;Kim, Bo-Sub;Park, Yang-Kyun
    • Food Science and Preservation
    • /
    • v.18 no.1
    • /
    • pp.1-6
    • /
    • 2011
  • Kochujang-gulbi, a Korean traditional food, was prepared with kochujang and freeze-dried gulbi slices. Kochujang-gulbi was treated with high hydrostatic pressure (200, 400 and 600 MPa) and gamma-irradiation (7, 10, 20 and 30 KGy) to improve its quality and shelf-life. The pH of high hydrostatic pressure and gamma-irradiation treated kochujang-gulbi samples did not significantly different compared to that of control. However, Hunter L value slightly increased, and Hunter a and b values decreased by high hydrostatic pressure and gamma-irradiation treatment. During storage, the pH and color of high hydrostatic pressure and gamma-irradiation treated kochujang-gulbi samples did not significantly changed. The VBN and TBA level decreased by the increase treatment of high hydrostatic pressure and then slowely increased during storage. The VBN and TBA level of kochujang-gulbi samples treated by the strong gamma ray emission slowely increased during storage. In particular, gamma-irradiation treatment was very effective to sterilize microorganisms when compared to that of high hydrostatic pressure in kochujang-gulbi products. In addition, the high hydrostatic pressure and gamma-irradiation treated kochujang-gulbi samples shown significantly lower total viable cell number than control for the 20 days of storage at room temperature with retort pouch packaging.

Evaluation of periopathogenic bacteria of peri-implantitis using real-time PCR in Koreans: pilot study (한국인의 임플란트 주위 질환에서 real time PCR법을 이용한 치주세균 평가: pilot study)

  • Lee, Mun-Young;Kwon, Eun-Young;Kim, Hyun-Joo;Lee, Ju-Youn;Joo, Ji-Young
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.3
    • /
    • pp.186-195
    • /
    • 2018
  • Purpose: We performed quantitative and qualitative analysis of typical periodontal bacteria using real time PCR method to investigate the microbiological difference according to the severity of peri-implant disease in Koreans. Materials and Methods: Total of 60 implants were divided into three groups (healthy group, peri-implant mucositis group, peri-implantitis group) through periapical radiographs and clinical indices. The evaluated clinical parameters were pocket depth, plaque index, suppuration and bleeding on probing. Using a sterilized curette instrument, microbial samples were collected from the subgingival plaque and real-time PCR was performed on five periodontal bacteria. The relative expression levels of microorganisms were compared by comparative delta-CT method. Results: The relative expression levels of E. corrodens and T. denticola were significantly higher in the peri-implantitis group (P < 0.017). On the other hand, the relative expression level of F. nucleatum and P. gingivalis was relatively high in the healthy implant group regardless of the severity of disease. P. intermedia was significantly lower in the healthy implant group (P < 0.017). Conclusion: Periodontal bacteria were detected in Koreans with peri-implant diseases, but there was no microbiological distribution similar to periodontitis.