• Title/Summary/Keyword: 방사선량 측정기

Search Result 38, Processing Time 0.038 seconds

Comparison of Skin Dose Measurement Using Glass Dosimeter and Diode for Breast Cancer Patients (유리 선량계와 다이오드 측정기를 이용한 유방암 환자의 체표면 선량측정 비교)

  • Ko, Young-Eun;Park, Sung-Ho;Choi, Byoung-Joon;Kim, Hee-Sun;Noh, Young-Ju
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.9-13
    • /
    • 2008
  • The purpose of this study was to measure the skin dose using the glass dosimeter and diode and to compare those measurements to the planned skin dose from the treatment planning system. For the reproducibility of the glass dosimeter (ASAHI TECHNO GLASS CIRPORATION, Japan), the same dose was irradiated to 40 glass dosimeters three times, among which 28 with the reproducibility within 3% were selected for the use of this study. For each of 27 breast cancer patients, the glass dosimeters and diodes were attached to 4 different locations on the skin to measure the dose during treatment. All the patients received one fraction of 180 cGy each. The maximum difference of measurements between the glass dosimeter and diode at the same location was 3.2%. Comparing with the planned skin dose from the treatment planning system (Eclipse v6.5, Varian, USA), the dose measured by the glass dosimeter and the diodeshowed on an average 3.4% and 2.3% difference, respectively. The measured doses were always less than the planned skin dose. This may be due to the specific errors of both detectors. Also, the difference may be caused by the fact that since the skin where the detectors were attached is pretty moveable, it was not fix the detectors on the skin.

  • PDF

The development of a high level radiation detector for reactor inspection robot (원자로 검사 로봇용 고준위 방사선 측정기 구현)

  • Lee, Nam-Ho;Cho, Jai-Wan;Kim, Seung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.05a
    • /
    • pp.278-280
    • /
    • 2005
  • 원자력발전소 내 원자로의 유지보수 작업을 수행하는 수중로봇은 고준위 방사선에 노출되고, 이로 인해 전자 장치의 오동작 및 고장이 유발될 수 있다. 따라서 허용 방사선량을 초과하지 않도록 피폭되는 누적 방사선량을 실시간으로 모니터링하는 장치가 필수적이다. 본 연구에서는 펄스형의 SiC 포토 다이오드와 선량 기억형인 MOSFET를 다중 방사선 센서로 사용하여 넘은 범위의 방사선 준위의 측정이 가능하고 측정 신뢰도가 향상된 고준위 방사선 측정기를 구현하였다. 이 장치는 측정 원리가 상이한 두 센서를 동일한 방사선 측정에 이용함으로써 방사선 측정의 안정성과 정확성이 향상된 것이 특징이다.

  • PDF

전신방사선조사(TBI)시 다이오드측정기(Diode detector) 및 열형광선량계(TLD)를 이용하여 측정한 골조직 선량감쇠에 대한 고찰

  • 임현실;이정진;장인기;김완선
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.29 no.1
    • /
    • pp.6-11
    • /
    • 2003
  • 목적 : 전신방사선조사(TBI)시 균등한 선량을 조사할 목적으로 사용되는 각 신체부위별 보상체(compensator) 두께의 결정은 열형광선량계(TLD)를 이용하여 표면선량(surface dose)을 측정하고, 심부선량(depth dose)으로 환산하는 방법을 주로 이용한다. 그러나 이와 같은 방법은 골(bone) 조직에 대한 선량감쇠(dose attenuation)의 영향이 고려되지 않아 신체중심부에서의 정확한 심부선량을 알 수가 없다. 이에 본 연구

  • PDF

Evaluation on the radiation exposure from activated wedge filter (10MV 이상 고에너지 사용시 wedge filler의 방사화가 작업환경에 미치는 영향평가)

  • Lee HwaJung;Kim DaeYoung;Kim WonTaek;Lee KangHyeok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.2
    • /
    • pp.69-79
    • /
    • 2004
  • In the process of photon treatments, linear accelerators with energies higher than 10 MV produce neutrons through the (${\gamma}$, n) interactions with the composite materials of the linac head md these materials further produce the induced radiations. We investigate the possible risks from these induced radiations especially in the wedge filters to the radiation workers. Wedge filters are used to modify the isodose profiles in the radiation treatment using the linear accelerator and always be handled by the radiation workers. For the background radiation, we measured the radiation in both the waiting room and the outside of the building for two hospitals, S and H. The results of S hospital were $0.11\;{\mu}Sv/hr$ and $0.10\;{\mu}Sv/hr$ for waiting room and outside respectively, and in the case of H hospital, they were $0.12\;{\mu}Sv/hr$ and $0.11\;{\mu}Sv/hr$. Using a survey meter, we measured the radiation from wedge filters inserted in 10 MV and 15 MV Siemens linear accelerators. The time series measurements were done in ${\sim}1$ minutes after exposure of 5 Gy of monitor units for the field size of $25{\times}25cm^2$. The starting value of 10 MV machine was about $3.26\;{\mu}Sv/hr$, which was three times higher than that of 10 MV. The measured radiation was from $^{28}Al$ and $^{53}Fe$ with a half life of 3.5 min. If the treatment patients are $20{\sim}50$ per day and the number of process of wedge filter change per patient is one or two, the annual dose equivalent is $0.08{\sim}0.4\;mSv$ for 10 MV, and $0.27{\sim}1.36\;mSv$ for 15 MV, which are in the range of dose equivalent limits of radiation workers.

  • PDF

Comparison of the Measured Radiation Dose-rate by the Ionization Chamber and GM(Geiger-Müller) Counter After Radioactive Iodine Therapy in Differentiated Thyroid Cancer Patients (분화성 갑상선암환자의 방사성 요오드 치료시 전리함과 Geiger-Muller계수관에서 방사선량률 측정값 비교)

  • Park, Kwang-hun;Kim, Kgu-hwan
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.565-570
    • /
    • 2016
  • Radioactive iodine($^{131}I$) treatment reduces recurrence and increases survival in patients with differentiated thyroid cancer. However, it is important in terms of radiation safety management to measure the radiation dose rate generated from the patient because the radiation emitted from the patient may cause the exposure. Research methods, it measured radiation dose-rate according to the elapsed time from 1 m from the upper abdomen of the patient by intake of radioactive iodine. Directly comparing the changes over time, high dose rate sensitivity and efficiency is statistically significant, and higher chamber than GM counter(p<0.05). Low dose rate sensitivity and efficiency in the chamber had lower levels than gm counter, but not statistically significant(p>0.05). In this study confirmed the characteristics of calibrated ionization chamber and GM counter according to the radiation intensity during high-dose radioactive iodine therapy by measuring the accurate and rapid radiation dose rate to the patient explains, discharged patients will be reduced to worry about radiation hazard of family and others person.

A Study on the dose distribution and the accuracy of the system for small fields of high energy x-rays (고에너지 X-선 소조사야의 선량분포 및 계측에 관한 연구)

  • 이호남;지광수;김재휴;지영훈
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.7 no.1
    • /
    • pp.32-44
    • /
    • 1995
  • I. 제 목 고에너지 X-선 소조사야의 선량분포 및 계측에 관한 연구 II. 연구의 목적 및 중요성 최근 수술이 어려운 뇌종양등에 대한 방사선수술법(Radiosurgery)이 관심의 대상이 되고 있다. 방사선수술법은 크게 나누어 200여개의 Co-60이 장착된 장치(Gamma Knife)를 이용하는 방법과, X-선치료기를 이용하는 방법은 몇개의 보조기구를 설치하면 가능한 매우 경제적인 방법이다. 따라서 Microtron을 이용한 방사선수술의 기초자료확보를 위하여 소조사야에 대한 선량과 선량분포의 측정 및 계산을 실시하였다. III. 연구의 내용 및 범위 Microtron으로부터 조사되는 6MV, 10MV, 21MV X-선의 지름 3cm이하 소조사야에 대한 정확한 선량 및 선량분포 자료를 확보하기 위해, 가. Microtron치료기와 보조장치등에 대한 정밀도 계측 및 평가 나. 보조 Collimator의 적당한 크기와 재료의 선택 및 설계, 제작. 다. 에너지와 조사야 크기 각각에 대한 여러측정장치(Ion chamber, Diode detector, TLD 및 Film등)를 이용한 선량 및 선량분포 측정. 라. 측정값들의 비교, 검토 및 측정된 자료에 의한 선량 및 선량분포의 계산을 수행했다. IV. 연구결과 및 활용에 대한 건의 본 연구에서 얻은 결과는 다음과 같다. 가. Microtron치료기와 보조장치등의 정확도의 허용 오차범위내에서 잘 일치하였다. 나. 보조 collimater adpator는 총 길이 24cm로 하였으며 재질로는 두랄미늄을 사용하였고, 보조 collimator는 low melting alloy를 사용하였으며 소조사야 크기의 정확도는 0.5mm이내에서 매우 잘 일치 하였다. 다. 방사선 수술법의 에너지 선택에 중요한 요소중의 하나인 penumbra는 6MV X-선에서 가장 적게 나타났으며 라. 소조사면에 대한 깊이-선량 백분율곡선은 모든 에너지에서 조사면이 작아질수록 표면으로 이동하는 경향을 보였다. 이상의 결과로부터 방사선 수술을 시행할 경우 수십억원에 이르는 장비의 도입이나 새로운 시설 없이 Microtron에서 조사되는 고에너지 X-선을 이용할 수 있을 것으로 사료된다. 또한 새로 구입한 측정기나 보조 Collimator를 이용하여 소조사야에 대한 선량측정기술을 습득함으로써 일반적인 소조사야의 방사선치료나 회전치료등에 활용할 수 있다.

  • PDF

Developement of Radiation Measuring System using Wireless Communication (무선통신을 이용한 방사선측정 시스템 개발)

  • Lee, Bong-Jae;Chang, Si-Young
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.2
    • /
    • pp.85-95
    • /
    • 1995
  • Radiation measuring system using wireless communication method with single channel has been diveloped and tested. In this system, radiation signals from GM tube are transformed into digital pulses in pulse processing circuit and modulated in FSK (frequency shift keying) circuit for digital communication and then wirelessly transmitted to a receiving unit. The digital pulses received are then demodulated in FSK circuit and converted into radiation dose/dose rate in the data acquisition unit to display on the screen of a personal computer. The performance of this system was evaluated by using both a pulse generator and a standard radiation source(Cs-137). In both cases, digital pulses with 5V were observed in pulse processing circuit without distortion of their shape through wireless communication system. The experimental results of radiation measurement by this system after several test-irradiation of GM detector to a standard radiation source(Cs-137), showed good agreement with irradiation dose rate within 10% difference, and proved that this system could be effectively utillized as radiation measuring instrument. It is expected that this wireless radiation measuring system developed for the first time in Korea, can be used as a radiation monitor as well as a personal dosimeter if we can further improve this system to adopt wireless multichannel communication system.

  • PDF

High speed 3D position detection of radiation using CCD camera (CCD 카메라를 이용한 방사선원 3차원 위치 고속 측정기)

  • Lee, Nam-Ho;Kim, Seung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.433-435
    • /
    • 2005
  • 광변환 물질을 사용하여 X-선이나 감마방사선을 가시광으로 변환한 다음 CCD 카메라를 통하여 광량을 측정하면 방사선의 양을 간접적으로 측정할 수 있다. 본 연구에서는 CCD형 비상대용 로봇용 고속 삼차원 방사선 위치 탐지장치에서 방사선 위치 센싱의 핵심 역할을 수행하는 CCD 방사선 탐지부를 간접 방사선 측정 방법을 응용하여 고안하고 구현한 다음 이에 대한 방사선 특성시험을 수행하였다. 시험 결과로 부터 구현한 CCD형 방사선 센서가 방사선 위치 및 선량 탐지장치로 활용 가능성이 충분함 확인하였다.

  • PDF