• Title/Summary/Keyword: 방법론 평가

Search Result 3,687, Processing Time 0.138 seconds

Second look arthroscopic findings after microfracture surgery in osteoarthritic knee (퇴행성 슬관절염에서 미세천공술 후 이차 관절경 소견)

  • Bae, Dae Kyung;Kim, Jin Moon;Lee, Jeong Heui;Park, Yong Koo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.3 no.2
    • /
    • pp.85-90
    • /
    • 1999
  • Purpose : The purpose of this study is to evaluate the clinical and histological results of the osteoarthritic patients who had second look arthroscopy after microfracture surgery. Materials and Methods : From Oct. 1997 to Dec. 1998, 46 patients, 48 knees were treated by microfracture technique. In the 22 patients, 24 knees, 'second-look' arthroscopies and biopsies were performed at 6 months following microfracture. Three patients were men and 19 patients were women. Average age of the patients were 58 years (range, 40-75 years). The average follow up period was 12 months(7-20 months). We analysed clinical results according to the nine-point scale. Also we observed type II collagen formation with immunohistochemical staining. Results : Clinical results were excellent in 83% and good in 17%. Among the 24 knees, more than 80% areas of chondral defect were covered with regenerated cartilage in 21 knees. Histologically, the regenerated tissue appears to be a hybrid of hyaline cartilage and fibrocartilage. Regenerated cartilage contains variable amount of type II collagen with immunohistochemical staining. Conclusion : Most of the patients had significant improvement clinically. 'Second-look' showed that the chondral defect areas were covered with newly grown grayish white tissue. Microfracture in the full thickness chondral defect provides and enriched environment for cartilaginous tissue regeneration.

  • PDF

Feasibility Study of Dose Evaluation of Stereotactic Radiosurgery using GafChromic $EBT^{(R)}$ Film (GafChromic $EBT^{(R)}$ 필름을 이용한 뇌정위방사선치료의 선량분석 가능성 평가)

  • Jang, Eun-Sung;Lee, Chul-Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.27-33
    • /
    • 2007
  • Purpose: We have performed SRS (stereotactic radiosurgery) for avm (arterry vein malformation) and brain cancer. In order to verify dose and localization of SRS, dose distributions from TPS ($X-Knife^{(R)}$ 3.0, Radionics, USA) and GafChromic $EBT^{(R)}$ film in a head phantom were compared. Materials and Methods: In this study, head and neck region of conventional humanoid phantom was modified by substituting one of 2.5 cm slap with five 0.5 cm acrylic plates to stack the GafChromic $EBT^{(R)}$ film slice by slice with 5 mm intervals. Four films and five acrylic plates were cut along the contour of head phantom in axial plane. The head phantom was fixed with SRS head ring and adapted SRS localizer as same as real SRS procedure. CT images of the head phantom were acquired in 5 mm slice intervals as film interval. Five arc 6 MV photon beams using the SRS cone with 2 cm diameter were delivered 300 cGy to the target in the phantom. Ten small pieces of the film were exposed to 0, 50, 100, 200, 300, 400, 500, 600, 700, 800, 900 cGy, respectively to calibrate the GafChromic $EBT^{(R)}$ film. The films in the phantom were digitized after 24 hours and its linearity was calibrated. The pixel values of the film were converted to the dose and compared with the dose distribution from the TPS calculation. Results: Calibration curve for the GafChromic $EBT^{(R)}$ film was linear up to 900 cGy. The R2 value was better than 0.992. Discrepancy between calculated from $X-Knife^{(R)}$ 3.0 and measured dose distributions with the film was less than 5% through all slices. Conclusion: It was possible to evaluate every slice of humanoid phantom by stacking the GafChromic EBT film which is suitable for 2 dimensional dosimetry, It was found that film dosimetry using the GafChromic $EBT^{(R)}$ film is feasible for routine dosimetric QA of stereotactic radiosurgery.

  • PDF

Measuring the Economic Impact of Item Descriptions on Sales Performance (온라인 상품 판매 성과에 영향을 미치는 상품 소개글 효과 측정 기법)

  • Lee, Dongwon;Park, Sung-Hyuk;Moon, Songchun
    • Journal of Intelligence and Information Systems
    • /
    • v.18 no.4
    • /
    • pp.1-17
    • /
    • 2012
  • Personalized smart devices such as smartphones and smart pads are widely used. Unlike traditional feature phones, theses smart devices allow users to choose a variety of functions, which support not only daily experiences but also business operations. Actually, there exist a huge number of applications accessible by smart device users in online and mobile application markets. Users can choose apps that fit their own tastes and needs, which is impossible for conventional phone users. With the increase in app demand, the tastes and needs of app users are becoming more diverse. To meet these requirements, numerous apps with diverse functions are being released on the market, which leads to fierce competition. Unlike offline markets, online markets have a limitation in that purchasing decisions should be made without experiencing the items. Therefore, online customers rely more on item-related information that can be seen on the item page in which online markets commonly provide details about each item. Customers can feel confident about the quality of an item through the online information and decide whether to purchase it. The same is true of online app markets. To win the sales competition against other apps that perform similar functions, app developers need to focus on writing app descriptions to attract the attention of customers. If we can measure the effect of app descriptions on sales without regard to the app's price and quality, app descriptions that facilitate the sale of apps can be identified. This study intends to provide such a quantitative result for app developers who want to promote the sales of their apps. For this purpose, we collected app details including the descriptions written in Korean from one of the largest app markets in Korea, and then extracted keywords from the descriptions. Next, the impact of the keywords on sales performance was measured through our econometric model. Through this analysis, we were able to analyze the impact of each keyword itself, apart from that of the design or quality. The keywords, comprised of the attribute and evaluation of each app, are extracted by a morpheme analyzer. Our model with the keywords as its input variables was established to analyze their impact on sales performance. A regression analysis was conducted for each category in which apps are included. This analysis was required because we found the keywords, which are emphasized in app descriptions, different category-by-category. The analysis conducted not only for free apps but also for paid apps showed which keywords have more impact on sales performance for each type of app. In the analysis of paid apps in the education category, keywords such as 'search+easy' and 'words+abundant' showed higher effectiveness. In the same category, free apps whose keywords emphasize the quality of apps showed higher sales performance. One interesting fact is that keywords describing not only the app but also the need for the app have asignificant impact. Language learning apps, regardless of whether they are sold free or paid, showed higher sales performance by including the keywords 'foreign language study+important'. This result shows that motivation for the purchase affected sales. While item reviews are widely researched in online markets, item descriptions are not very actively studied. In the case of the mobile app markets, newly introduced apps may not have many item reviews because of the low quantity sold. In such cases, item descriptions can be regarded more important when customers make a decision about purchasing items. This study is the first trial to quantitatively analyze the relationship between an item description and its impact on sales performance. The results show that our research framework successfully provides a list of the most effective sales key terms with the estimates of their effectiveness. Although this study is performed for a specified type of item (i.e., mobile apps), our model can be applied to almost all of the items traded in online markets.

Soil Loss and Pollutant Load Estimation in Sacheon River Watershed using a Geographic Information System (GIS를 이용한 동해안 하천유역의 토양유실량과 오염부하량 평가 -사천천을 중심으로-)

  • Cho, Jae-Heon;Yeon, Je-Chul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.7
    • /
    • pp.1331-1343
    • /
    • 2000
  • Through the integration of USLE and GIS, the methodology to estimate the soil loss was developed, and applicated to the Sacheon river in Gangrung. Using GIS, spatial analysis such as watershed boundary determination, flow routing. slope steepness calculation was done. Spatial information from the GIS application was given for each grid. With soil and land use map, information about soil classification and land use was given for each grid too. Based upon these data, thematic maps about the factors of USLE were made. We estimated the soil loss by overlaying the thematic maps. In this manner, we can assess the degree of soil loss for each grid using GIS. Annual average soil loss of Sacheon river watershed is 1.36 ton/ha/yr. Soil loss in forest, dry field, and paddy field is 0.15 ton/ha/yr, 27.04 ton/ha/yr, 0.78 ton/ha/yr respectively. The area of dry field, which is 4% of total area, is $2.4km^2$. But total soil loss of dry field is 6561 ton/yr, and it occupies 84.9 % of total soil loss eroded in Sacheon river watershed. Comparing with the 11.2 ton/ha/yr of an average soil loss tolerance for cropland, provision for the soil loss in dry field is necessary. Run-off and water quality of Sacheon river were measured two times in flood season: from July 24, 1998 to July 28 and from September 29 to October 1. As the run-off of the river increased, SS, TN, TP concentrations and pollutant loadings increased. SS, TN, TP loads of Sacheon river discharged during the 2 heavy rains were 21%, 39%, and 19% of the total pollutant loadings generated in the Sacheon river watershed for one year. We can see that much pollutants are discharged in short period of flood season.

  • PDF

Manufacture of Daily Check Device and Efficiency Evaluation for Daily Q.A (일일 정도관리를 위한 Daily Check Device의 제작 및 효율성 평가)

  • Kim Chan-Yong;Jae Young-Wan;Park Heung-Deuk;Lee Jae-Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.2
    • /
    • pp.105-111
    • /
    • 2005
  • Purpose : Daily Q.A is the important step which must be preceded in a radiation treatment. Specially, radiation output measurement and laser alignment, SSD indicator related to a patient set-up recurrence must be confirmed for a reasonable radiation treatment. Daily Q.A proceeds correctness and a prompt way, and needs an objective measurement basis. Manufacture of the device which can facilitate confirmation of output measurement and appliances check at one time was requested. Materials and Methods : Produced the phantom formal daily check device which can confirm a lot of appliances check (output measurement and laser alignment. field size, SSD indicator) with one time of set up at a time, and measurement observed a linear accelerator (4 machine) for four months and evaluated efficiency. Results : We were able to confirm an laser alignment, field size, SSD indicator check at the same time, and out put measurement was possible with the same set up, so daily Q.A time was reduced, and we were able to confirm an objective basis about each item measurement. As a result of having measured for four months, output measurement within ${\pm}2%$, and measured laser alignment, field size, SSD indicator in range within ${\pm}1mm$. Conclusion : We can enforce output measurement and appliances check conveniently, and time was reduced and was able to raise efficiency of business. We were able to bring a cost reduction by substitution expensive commercialized equipment. Further It is necessary to makes a product as strong and slight materials, and improve convenience of use.

  • PDF

Imaging dose evaluations on Image Guided Radiation Therapy (영상유도방사선치료시 확인 영상의 흡수선량평가)

  • Hwang, Sun Boong;Kim, Ki Hwan;kim, il Hwan;Kim, Woong;Im, Hyeong Seo;Han, Su Chul;Kang, Jin Mook;Kim, Jinho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.1-11
    • /
    • 2015
  • Purpose : Evaluating absorbed dose related to 2D and 3D imaging confirmation devices Materials and Methods : According to the radiographic projection conditions, absorbed doses are measured that 3 glass dosimeters attached to the centers of 0', 90', 180' and 270' in the head, thorax and abdomen each with Rando phantom are used in field size $26.6{\times}20$, $15{\times}15$. In the same way, absorbed doses are measured for width 16cm and 10cm of CBCT each. OBI(version 1.5) system and calibrated glass dosimeters are used for the measurement. Results : AP projection for 2D imaging check, In $0^{\circ}$ degree absorbed doses measured in the head were $1.44{\pm}0.26mGy$ with the field size $26.6{\times}20$, $1.17{\pm}0.02mGy$ with the field size $15{\times}15$. With the same method, absorbed doses in the thorax were $3.08{\pm}0.86mGy$ to $0.57{\pm}0.02mGy$ by reducing field size. In the abdomen, absorbed dose were reduced $8.19{\pm}0.54mGy$ to $4.19{\pm}0.09mGy$. Finally according to the field size, absorbed doses has decreased by average 5~12%. With Lateral projection, absorbed doses showed average 5~8% decrease. CBCT for 3D imaging check, CBDI in the head were $4.39{\pm}0.11mGy$ to $3.99{\pm}0.13mGy$ by reducing the width 16cm to 10cm. In the same way in thorax the absorbed dose were reduced $34.88{\pm}0.93(10.48{\pm}0.09)mGy$ to $31.01{\pm}0.3(9.30{\pm}0.09)mGy$ and $35.99{\pm}1.86mGy$ to $32.27{\pm}1.35mGy$ in the abdomen. With variation of width 16cm and 10cm, they showed 8~11% decrease. Conclusion : By means of reducing 2D field size, absorbed dose were decreased average 5~12% in 3D width size 8~11%. So that it is necessary for radiation therapists to recognize systematical management for absorbed dose for Imaging confirmation. and also for frequent CBCT, it is considered whether or not prescribed dose for RT refer to imaging dose.

  • PDF

Accuracy evaluation of treatment plan according to CT scan range in Head and Neck Tomotherapy (두경부 토모테라피 치료 시 CT scan range에 따른 치료계획의 정확성 평가)

  • Kwon, Dong Yeol;Kim, Jin Man;Chae, Moon Ki;Park, Tae Yang;Seo, Sung Gook;Kim, Jong Sik
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.2
    • /
    • pp.13-24
    • /
    • 2019
  • Purpose: CT scan range is insufficient for various reasons in head and neck Tomotherapy®. To solve that problem, Re-CT simulation is good because CT scan range affects accurate dose calculations, but there are problems such as increased exposure dose, inconvenience, and a change in treatment schedule. We would like to evaluate the minimum CT scan range required by changing the plan setup parameter of the existing CT scan range. Materials and methods: CT Simulator(Discovery CT590 RT, GE, USA) and In House Head & Neck Phantom are used, CT image was acquired by increasing the image range from 0.25cm to 3.0cm at the end of the target. The target and normal organs were registered in the Head & Neck Phantom and the treatment plan was designed using ACCURAY Precision®. Prescription doses are Daily 2.2Gy, 27 Fxs, Total Dose 59.4Gy. Target is designed to 95%~107% of prescription dose and normal organ dose is designed according to SMC Protocol. Under the same treatment plan conditions, Treatment plans were designed by using five methods(Fixed-1cm, Fixed-2.5cm, Fixed-5cm, Dynamic-2.5cm Dynamic-5cm) and two pitches(0.43, 0.287). The accuracy of dose delivery for each treatment plan was analyzed by using EBT3 film and RIT(Complete Version 6.7, RIT, USA). Results: The accurate treatment plan that satisfying the prescribed dose of Target and the tolerance dose in normal organs(SMC Protocol) require scan range of at least 0.25cm for Fixed-1cm, 0.75cm for Fixed-2.5cm, 1cm for Dynamic-2.5cm, and 1.75cm for Fixed-5cm and Dynamic-5cm. As a result of AnalysisAnalysis by RIT. The accuracy of dose delivery was less than 3% error in the treatment plan that satisfied the SMC Protocol. Conclusion: In case of insufficient CT scan range in head and neck Tomotherapy®, It was possible to make an accurate treatment plan by adjusting the FW among the setup parameter. If the parameter recommended by this author is applied according to CT scan range and is decide whether to re-CT or not, the efficiency of the task and the exposure dose of the patient are reduced.

Airway Narrowing Patterns during Obstructive Sleep Apnea : Airway CT and Multi-level Airway Pressure Monitoring (수면무호흡 중에 관찰된 다양한 기도협착의 형태:상기도 CT 및 상기도 압력 측정법)

  • Jeong, Seung-Cheol;Hong, Seung-Bong;Kyung, Seung-Hyun;Kim, Hoo-Won
    • Sleep Medicine and Psychophysiology
    • /
    • v.7 no.1
    • /
    • pp.18-26
    • /
    • 2000
  • Objectives: To investigate the airway narrowing patterns by multi-level airway pressure(MAP) monitoring during sleep and to evaluate the value of CT scan taken during waking and sleep apneic periods to identify the level of airway narrowing(LAN) in patients with obstructive sleep apnea syndrome(OSAS). Methods: Eleven patients with OSAS underwent a night polysomnography with continuous MAP monitoring by 4-sensor(placed at nasopharynx, caudal-uvula, hypopharynx, esophagus) or 2-sensor(placed at caudal-uvula and esophagus) catheter. All patients had cine CT at five levels of high retro and alatal, low retropalatal, retroglossal, epiglottis and hypopharynx during awake and sleep periods. In each patient, LAN determined by CT scan($LAN_{CT}$) during sleep apnea was compared with LAN by MAP monitoring($LAN_{MAP}$). Results: MAP monitoring showed that four patients(36%) had a single pattern of LAN while the other seven patients(64%) showed two or more different LANs in different apneic episodes. Velopharynx was the most common level of frequently observed airway narrowing during sleep apnea(63.6%). However, a single pattern of airway narrowing was more frequent(72.7%) in airway CT during sleep apnea. Velopharynx was the most common narrowest level also in apneic CT(66%). In comparing $LAN_{CT}$ with $LAN_{MAP}$, the $LAN_{CT}$ of five patients(45.5%) were high-concordant, those of another five(45.5%) low-concordant, and that of one(9%) discordant with $LAN_{MAP}$. Conclusions: Cine CT scan during the awake state or sleep apnea may not reflect the LAN correctly in OSAS because most patients showed two or more different airway narrowing patterns during different episodes of sleep apnea in each patient.

  • PDF

The Study About Intra-Familial Transmission of the Neurological Soft Signs in Schizophrenia (정신분열병에서 연성 신경학적 징후의 가족내 전달에 관한 연구)

  • Yoo, Sujung;Choi, Yongrak;Lee, Sangick;Shin, Chuljin;Kim, Siekyeong;Son, Jungwoo
    • Korean Journal of Biological Psychiatry
    • /
    • v.15 no.2
    • /
    • pp.83-91
    • /
    • 2008
  • Objectives : Neurological soft signs have been regarded as endophenotypes associated with the genetic basis of schizophrenia. This study was to investigate the intra-familial correlations of the neurological soft signs according to their genetic loading. Methods : Schizophrenic patients(N=14) were included, who had one parent with a family history of schizophrenia and the other without it. Genetic loading was determined by the patient's family history of schizophrenia using the Family Interview for Genetic Studies(FIGS). These parents were subdivided into two groups. The first group was designated as 'presumed carriers'(N=9) of genetic loading, who had one or more schizophreic firstor second-degree relatives. The second group was designated as 'presumed non-carriers'(N=11) of genetic loading, who had no schizophrenic first- or second-degree relatives. Normal controls(N=12) consisted of people without schizophrenic relatives. NSS were evaluated using the Neurological Evaluation Scale-Korean Version (NES-K), and the intra-familial correlations of NSS were tested using the Intra-Class Coefficients(ICC) method. Results : The scores of Motor Coordination subdimension of NES-K were significantly correlated between the patients and their presumed carriers(ICC=.804, p=.016), but not significantly correlated between the patients and their presumed noncarriers. In other subdimensions of NES-K, no significant correlation were found between the patients and their parents regardless of the genetic loading. But, there were no statistically significant differences in the scores of Motor Coordination subdimension of NES-K between the patients and controls. Conclusion : This study did not prove that the neurological soft signs might be an endophenotype of schizophrenia that cosegregate with the genetic loading. The future study using more subjects than this would be needed.

  • PDF

Clinical Evaluation of Patients with Unilateral Non-functioning Kidney on $^{99m}Tc-DMSA$ scan ($^{99m}Tc-DMSA$ 스캔에서 일측성으로 동위원소 섭취가 안되는 환아들에 대한 임상적 고찰)

  • Bae Hyun-Chul;Kim Hyun-Young;Kim Pyung-Kil;Han Sang-Won
    • Childhood Kidney Diseases
    • /
    • v.1 no.1
    • /
    • pp.31-37
    • /
    • 1997
  • The DMSA scan is a useful radiologic study in diagnosis of morphologic and functional diseases of kidney. We evaluated the distribution of sex and age, clinical manifestations, diagnosis, combined diseases, treatment and prognosis of the 61 patients with non-functioning kidney(no isotope uptake or uptake below 5% in DMSA scan) who admitted in our hospital from 1980 to 1995. The proportion of patients under 1 year old age was 46%. Sex ratio was 1.4:1 with male predominance. Most diagnosis of non-functioning kidneys were congenital such as multicystic dysplastic kidney, hydronephrosis due to ureteropelvic junction obstruction, renal agenesis and renal hypoplasia. In order of frequency thirty one percent of them were previously detected on antenatal ultrasonogram. Treatment consisted of operation in 47.5%, mostly nephrectomy and 32.8% of patients were followed up at OPD base without definite treatment. The most common combined diseases was hydronephrosis, in 4patients who had both kidneys inveloved progressed to chronic renal failure, but the prognosis in most cases were good. It is important to evaluate renal diseases in perinatal periods, and we believe that highly sensitive diagnostic study contribute to early treatment plan and thus to good prognosis.

  • PDF