• Title/Summary/Keyword: 방법론 평가

Search Result 3,687, Processing Time 0.032 seconds

The Conceptual Intersection between the Old and the New and the Transformation of the Traditional Knowledge System (신구(新舊) 관념의 교차와 전통 지식 체계의 변용)

  • Lee, Haenghoon
    • The Journal of Korean Philosophical History
    • /
    • no.32
    • /
    • pp.215-249
    • /
    • 2011
  • This essay reflects on the modernity of Korea by examining the transformation of the traditional knowledge system from a historico-semantic perspective with its focus on the opposition and collision of the old and the new conception occurred in the early period(1890~1910) of the acceptance of the Western modern civilization. With scientific success, trick of reason, Christianity and evolutionary view of history, the Western modernity regarded itself as a peak of civilization and forced the non-Western societies into the world system in which they came to be considered as 'barbarism(野蠻)' or 'half-enlightened(半開).' The East Asian civilization, which had its own history for several centuries, became degraded as kind of delusion and old-fashioned customs from which it ought to free itself. The Western civilization presented itself as exemplary future which East Asian people should achieve, while East Asian past traditions came to be conceived as just unnecessary vestiges which it was better to wipe out. It can be said that East Asian modernization was established through the propagation and acceptance of the modern products of the Western civilization rather than through the preservation of its past experience and pursuit of the new at the same time. Accordingly, it is difficult to apply directly to East Asian societies Koselleck's hypothesis; while mapping out his Basic Concept of History, he assumed that, in the so-called 'age of saddle,' semantic struggle over concepts becomes active between the past experience and the horizon of expectation on the future, and concepts undergoes 'temporalization', 'democratization', 'ideologization', 'politicization.'The struggle over the old and new conceptions in Korea was most noticeable in the opposition of the Neo-Confucian scholars of Hwangseongsinmun and the theorists of civilization of Doknipsinmun. The opposition and struggle demanded the change of understanding in every field, but there was difference of opinion over the conception of the past traditional knowledge system. For the theorists of civilization, 'the old(舊)' was not just 'past' and 'old-fashioned' things, but rather an obstacle to the building of new civilization. On the other hand, it contained the possibility of regeneration(新) for the Neo-Confucian scholars; that is, they suggested finding a guide into tomorrow by taking lessons from the past. The traditional knowledge system lost their holy status of learning(聖學) in the process of its change into a 'new learning(新學),' and religion and religious tradition also weakened. The traditional knowledge system could change itself into modern learning by accepting scientific methodology which pursues objectivity and rationality. This transformation of the traditional knowledge system and 'the formation of the new learning from the old learning' was accompanied by the intersection between the old and new conceptions. It is necessary to pay attention to the role played by the concept of Sil(hak)(實學) or Practical Learning in the intersection of the old and new conceptions. Various modern media published before and after the 20th century show clearly the multi-layered development of the old and new conceptions, and it is noticeable that 'Sil(hak)' as conceptual frame of reference contributed to the transformation of the traditional knowledge system into the new learning. Although Silhak often designated, or was even considered equivalent to, the Western learning, Neo-Confucian scholars reinterpreted the concept of 'Silhak' which the theorists of civilization had monopolized until then, and opened the way to change the traditional knowledge system into the new learning. They re-appropriated the concept of Silhak, and enabled it to be invested with values, which were losing their own status due to the overwhelming scientific technology. With Japanese occupation of Korea by force, the attempt to transform the traditional knowledge system independently was obliged to reach its own limit, but its theory of 'making new learning from old one' can be considered to get over both the contradiction of Dondoseogi(東道西器: principle of preserving Eastern philosophy while accepting Western technology) and the de-subjectivity of the theory of civilization. While developing its own logic, the theory of Dongdoseogi was compelled to bring in the contradiction of considering the indivisible(道and 器) as divisible, though it tried to cope with the reality where the principle of morality and that of competition were opposed each other and the ideologies of 'evolution' and 'progress' prevailed. On the other hand, the theory of civilization was not free from the criticism that it brought about a crack in subjectivity due to its internalization of the West, cutting itself off from the traditional knowledge system.

Scalp Dose Evaluation According Radiation Therapy Technique of Whole Brain Radiation Therapy (전뇌 방사선치료 시 치료방법에 따른 두피선량평가)

  • Jang, Joon-Yung;Park, Soo-Yun;Kim, Jong-Sik;Choi, Byeong-Gi;Song, Gi-Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.2
    • /
    • pp.103-108
    • /
    • 2011
  • Purpose: Opposing portal irradiation with helmet field shape that has been given to a patient with brain metastasis can cause excess dose in patient's scalp, resulting in hair loss. For this reason, this study is to quantitatively analyze scalp dose for effective prevention of hair loss by comparing opposing portal irradiation with scalp-shielding shape and tomotherapy designed to protect patient's scalp with conventional radiation therapy. Materials and Methods: Scalp dose was measured by using three therapies (HELMET, MLC, TOMO) after five thermo-luminescence dosimeters were positioned along center line of frontal lobe by using RANDO Phantom. Scalp dose and change in dose distribution were compared and analyzed with DVH after radiation therapy plan was made by using Radiation Treatment Planning System (Pinnacle3, Philips Medical System, USA) and 6 MV X-ray (Clinac 6EX, VARIAN, USA). Results: When surface dose of scalp by using thermo-luminescence dosimeters was measured, it was revealed that scalp dose decreased by average 87.44% at each point in MLC technique and that scalp dose decreased by average 88.03% at each point in TOMO compared with HELMET field therapy. In addition, when percentage of volume (V95%, V100%, V105% of prescribed dose) was calculated by using Dose Volume Histogram (DVH) in order to evaluate the existence or nonexistence of hotspot in scalp as to three therapies (HELMET, MLC, TOMO), it was revealed that MLC technique and TOMO plan had good dose coverage and did not have hot spot. Conclusion: Reducing hair loss of a patient who receives whole brain radiotherapy treatment can make a contribution to improve life quality of the patient. It is expected that making good use of opposing portal irradiation with scalp-shielding shape and tomotherapy to protect scalp of a patient based on this study will reduce hair loss of a patient.

  • PDF

Dose Comparison of Treatment Plans Using Different Ir-192 Sources and Treatment Planning Systems for Intracavitary HDR Brachytherapy (고선량률 강내 근접치료에 사용되는 Ir-192 선원과 치료계획 시스템간의 계산선량 비교)

  • Park, Dong-Wook;Kim, Young-Seok;Park, Sung-Ho;Choi, Eun-Kyung;Kim, Jong-Hoon;Lee, Sang-Wook;Song, Si-Yeol;Ahn, Seung-Do;Noh, Young-Joo
    • Progress in Medical Physics
    • /
    • v.20 no.1
    • /
    • pp.1-6
    • /
    • 2009
  • For HDR intracavitary brachytherapy with ovoids and a tandem, we compared the dose discrepancy of treatment plans using two different Ir-192 sources (microSelectron, Varian) and generated on two different treatment planning systems (PLATO, BrachyVision). The treatment plans of ten patient treated from Oct. 2007 to Jan. 2008 were selected for these comparisons. For the comparison of dose calculation using different sources, the average discrepancies were $-0.91{\pm}0.09%$, $-0.27{\pm}0.07%$, $0.22{\pm}0.39%$, and $0.88{\pm}0.37%$ in total treatment time and at B-point and ICRU bladder and rectum reference point, respectively. Comparing the two systems, the average dose discrepancies between treatment planning programs were $-0.22{\pm}0.42%$, $-0.25{\pm}0.29%$, $-0.23{\pm}0.63%$, and $-0.17{\pm}0.76%$, and the average dose discrepancies between positioning methods (PLATO with film and BrachyVision with digitial image) were $-0.61{\pm}0.59%$, $-0.77{\pm}0.45%$, $-0.72{\pm}1.70%$, and $0.35{\pm}2.82%$ at A-point, B-point, and ICRU bladder and rectum reference points, respectively. The rectal dose discrepancies between two systems were reached 5.87%. The difference in the dwell position expected by each TPS are mainly affected by the differences in the positioning method in TPSs and have an effect on dose calculations of rectal and bladder located in AP direction.

  • PDF

Deep inspiration breath-hold (DIBH) 적용한 림프절이 포함된 왼편 유방암의 방사선 치료계획에 따른 주변 장기 선량 평가

  • Jeong, Da-Lee;Gang, Hyo-Seok;Choe, Byeong-Jun;Park, Sang-Jun;Lee, Geon-Ho;Lee, Du-Sang;An, Min-U;Jeon, Myeong-Su
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.27-35
    • /
    • 2017
  • Purpose: On the left side, breast cancer patients have more side effects than those on the right side because of unnecessary doses in normal organs such as heart and lung. DIBH is performed to reduce this. To evaluate the dose of peripheral organs in the left breast cancer including supraclavicular lymph nodes and internal mammary lymph nodes according to the treatment planning method of Conventional Radiation Therapy, Intensity Modulated Radiation Therapy and Volumetric Modulated Arc Therapy. Materials and Methods: We performed CT-simulation using free breathing and deep inspiration breath-hold technique for 8 patients including left supraclavicular lymph nodes and internal mammary lymph nodes. Based on the acquired CT images, the contour of the body is drawn and the convention is performed so that $95%{\leftarrow}PTV$, $Dmax{\leftarrow}110%$. Conventional Radiation Therapy used a one portal technique on the supraclavicular lymph node and used a field in field technique tangential beam on the breast. Intensity Modulated Radiation Therapy was composed of 7 static fields. Volumetric Modulated Arc Therapy was planned using 2 ARC with a turning radius of $290^{\circ}$ to $179^{\circ}$. The peripheral normal organs dose was analyzed by referring to the dose volume of Eclipse. Results: By applying the deep inspiration breath-hold technique, the mean interval between the heart and chest wall increased $1.6{\pm}0.6cm$. The mean dose of lung was $19.2{\pm}1.0Gy$, which was the smallest value in Intensity Modulated Radiation Therapy. The V30 (%) of the heart was $2.0{\pm}1.9$, which was the smallest value in Intensity Modulated Radiation Therapy. In the left anterior descending coronary artery, the dose was $25.4{\pm}5.4Gy$, which was the smallest in Intensity Modulated Radiation Therapy. The maximum dose value of the Right breast was $29.7{\pm}4.3Gy$ at Intensity Modulated Radiation Therapy. Conclusion: When comparing the values of surrounding normal organs, Intensity Modulated Radiation Therapy and Volumetric Modulated Arc Therapy were applicable values for treatment. Among them, Intensity Modulated Radiation Therapy is considered to be a suitable treatment planning method.

  • PDF

Workplace Friendship and Organizational Effectiveness of Dental Hygienists (치과의료기관 근무자들의 프렌드십과 조직효과성 관계 연구)

  • Yoo, Youngsuk;Seo, Youngjoon;Kim, Sungho
    • Journal of dental hygiene science
    • /
    • v.12 no.6
    • /
    • pp.644-651
    • /
    • 2012
  • This study purports to measure the level of work friendship in dental clinic and examines the friendship's effect on the organizational effectiveness. Data were collected from workers who worked in dental clinic located in Seoul and Gyeonggi areas by self-administered questionnaires from early in October till lately in September, 2009 through direct interview and e-mail. Among 250 questionnaires, 240 responses were returned, and 17 copies with an inaccurate answer were excluded. Finally 223 responses were analyzed through SPSS program. The study revealed that the work friendship in dental clinic has enormous influence on job satisfaction, occupational commitment, intent to leave, stress etc. The results imply that the managers of the dental clinics need to create an organizational climate which emphasizes on a good relationship among members and have them take part in various committees or informal activities.

Effect of Human Implantable Medical Devices on Dose and Image Quality during Chest Radiography using Automatic Exposure Control (자동노출제어를 적용한 흉부 방사선 검사 시 인체 이식형 의료기기가 선량과 화질에 미치는 영향)

  • Kang-Min Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.3
    • /
    • pp.257-265
    • /
    • 2024
  • In this study, we applied AEC(Auto Exposure Control), which is used in many chest examinations, to evaluate whether medical devices inserted into the body affect the dose and image quality of chest images. After attaching three HIMD(Human implantable medical devices) to the ion chamber, the Monte Carlo methodology-based program PCXMC(PC Program for X-ray Monte Carlo) 2.0 was applied to measure the effective dose by inputting the DAP(Dose Ares Product) value derived from the Pacemaker and CRT and Chemoport Additionally, to evaluate image quality, we set three regions of interest and one noise region on the chest and measured SNR and CNR. The final study results showed significant differences in DAP and Effective dose. There was a significant difference between Pacemaker and CRT when AEC was applied and not applied. (p<0.05) When applied, the dose increased by 37% for Pacemaekr and 52% for CRT. Chemoport showed a 10% increase in effective dose depending on whether AEC was applied, but there was no significant difference. (p>0.05) In the image quality evaluation, there was no significant difference in image quality between all HIMD insertions and AEC applied or not. (p>0.05) Therefore, when the HIMD was inserted into the chest during a chest x ray and overlapped with the ion chamber sensor, the effective dose increased, and there was no difference in image quality even at a low dose without AEC. Therefore, when performing a chest X-ray examination of a patient with a HIMD inserted, it is considered that performing the examination without applying AEC is a method that can be considered to reduce the patient's radiation exposure.

Quality Assurance of Leaf Speed for Dynamic Multileaf Collimator (MLC) Using Dynalog Files (Dynalog file을 이용한 동적다엽조준기의 Leaf 속도 정도관리 평가)

  • Kim, Joo Seob;Ahn, Woo Sang;Lee, Woo Suk;Park, Sung Ho;Choi, Wonsik;Shin, Seong Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.305-312
    • /
    • 2014
  • Purpose : The purpose of this study is to analyze the mechanical and leaf speed accuracy of the dynamic multileaf collimator (DMLC) and determine the appropriate period of quality assurance (QA). Materials and Methods : The quality assurance of the DMLC equipped with Millennium 120 leaves has been performed total 92 times from January 2012 to June 2014. The the accuracy of leaf position and isocenter coincidence for MLC were checked using the graph paper and Gafchromic EBT film, respectively. The stability of leaf speed was verified using a test file requiring the leaves to reach maximum leaf speed during the gantry rotation. At the end of every leaf speed QA, dynamic dynalog files created by MLC controller were analyzed using dynalog file viewer software. This file concludes the information about the planned versus actual position for all leaves and provides error RMS (root-mean square) for individual leaf deviations and error histogram for all leaf deviations. In this study, the data obtained from the leaf speed QA were used to screen the performance degradation of leaf speed and determine the need for motor replacement. Results : The leaf position accuracy and isocenteric coincidence of MLC was observed within a tolerance range recommanded from TG-142 reports. Total number of motor replacement were 56 motors over whole QA period. For all motors replaced from QA, gradually increased patterns of error RMS values were much more than suddenly increased patterns of error RMS values. Average error RMS values of gradually and suddenly increased patterns were 0.298 cm and 0.273 cm, respectively. However, The average error RMS values were within 0.35 cm recommended by the vendor, motors were replaced according to the criteria of no counts with misplacement > 1 cm. On average, motor replacement for gradually increased patterns of error RMS values 22 days. 28 motors were replaced regardless of the leaf speed QA. Conclusion : This study performed the periodic MLC QA for analyzing the mechanical and leaf speed accuracy of the dynamic multileaf collimator (DMLC). The leaf position accuracy and isocenteric coincidence showed whthin of MLC evaluation is observed within the tolerance value recommanded by TG-142 report. Based on the result obtained from leaf speed QA, we have concluded that QA protocol of leaf speed for DMLC was performed at least bimonthly in order to screen the performance of leaf speed. The periodic QA protocol can help to ensure for delivering accurate IMRT treatment to patients maintaining the performance of leaf speed.

A Study on Usefulness of Clinical Application of Metal Artifact Reduction Algorithm in Radiotherapy (방사선치료 시 Metal artifact reduction Algorithm의 임상적용 유용성평가)

  • Park, Ja Ram;Kim, Min Su;Kim, Jeong Mi;Chung, Hyeon Suk;Lee, Chung Hwan;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.9-17
    • /
    • 2017
  • Purpose: The tissue description and electron density indicated by the Computed Tomography(CT) number (also known as Hounsfield Unit) in radiotherapy are important in ensuring the accuracy of CT-based computerized radiotherapy planning. The internal metal implants, however, not only reduce the accuracy of CT number but also introduce uncertainty into tissue description, leading to development of many clinical algorithms for reducing metal artifacts. The purpose of this study was, therefore, to investigate the accuracy and the clinical applicability by analyzing date from SMART MAR (GE) used in our institution. Methode: and material: For assessment of images, the original images were obtained after forming ROIs with identical volumes by using CIRS ED phantom and inserting rods of six tissues and then non-SMART MAR and SMART MAR images were obtained and compared in terms of CT number and SD value. For determination of the difference in dose by the changes in CT number due to metal artifacts, the original images were obtained by forming PTV at two sites of CIRS ED phantom CT images with Computerized Treatment Planning (CTP system), the identical treatment plans were established for non-SMART MAR and SMART MAR images by obtaining unilateral and bilateral titanium insertion images, and mean doses, Homogeneity Index(HI), and Conformity Index(CI) for both PTVs were compared. The absorbed doses at both sites were measured by calculating the dose conversion constant (cCy/nC) from ylinder acrylic phantom, 0.125cc ionchamber, and electrometer and obtaining non-SMART MAR and SMART MAR images from images resulting from insertions of unilateral and bilateral titanium rods, and compared with point doses from CTP. Result: The results of image assessment showed that the CT number of SMART MAR images compared to those of non-SMART MAR images were more close to those of original images, and the SD decreased more in SMART compared to non-SMART ones. The results of dose determinations showed that the mean doses, HI and CI of non-SMART MAR images compared to those of SMART MAR images were more close to those of original images, however the differences did not reach statistical significance. The results of absorbed dose measurement showed that the difference between actual absorbed dose and point dose on CTP in absorbed dose were 2.69 and 3.63 % in non-SMRT MAR images, however decreased to 0.56 and 0.68 %, respectively in SMART MAR images. Conclusion: The application of SMART MAR in CT images from patients with metal implants improved quality of images, being demonstrated by improvement in accuracy of CT number and decrease in SD, therefore it is considered that this method is useful in dose calculation and forming contour between tumor and normal tissues.

  • PDF

Dose Evaluation of Dental Artifacts Using MVCT in Head and Neck (두경부암 환자의 MVCT를 이용한 치아 인공물 보정에 따른 선량평가)

  • Shin, Chung Hun;Yun, In Ha;Jeon, Su Dong;Kim, Jeong Mi;Kim, Ho Jin;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.2
    • /
    • pp.25-31
    • /
    • 2019
  • Purpose: Metals induce metal artifact during CT-image for therapy planning, and it occurs images distortion, which affects the volumetric measurement and radiation calculation. In the case of using megavoltage computed tomography(MVCT), the volume of metals can be measured as similar to true volume due to minimal metal artifact outcome. In this study, radiation assessment was conducted by comparing teeth volume from images of kVCT and MVCT of head and neck cancer patients, then assigning to kVCT image to calculate radiation after obtaining the similar volume of true teeth volume from MVCT. Also, formal IR image was able to verify the accuracy of radiation calculation. Material and method: 5 head and neck cancer patients who had intensity-modulated radiation therapy from Radixact® Series were of the subject in this study. Calculations of radiation when constraining true teeth volume out of kVCT image(A-CT) and when designated specific HU after teeth assigned using MVCT image were compared with formal IR image. Treatment planning was devised at the same constraints and mean dose was measured at the radiation assess points. The points were anterior of the teeth, between PTV and the teeth, the interior of PTV near the teeth, and the teeth where 5cm distance from PTV. Result: A difference of metals volume from kVCT and MVCT image was mean 3.49±2.61cc, maximum 7.43cc. PTV was limited to where the internal teeth were fully contained. The results of PTV dose evaluation showed that the average CI value of the kVCT treatment planning without the artifact correction was 0.86, and the average CI value of the kVCT with the artifact correction using MVCT image was 0.9. Conclusion: When the Treatment Planning was made without correction of metal artifacts, the dose of PTV was underestimated, indicating that dose uncertainty occurred. When the computerized treatment plan was made without correction of metal artifacts, the dose of PTV was underestimated, indicating that dose uncertainty occurred.

Prognostic Value of p53 Overexpression in Patients with Pathologic Stage I Non-small Cell Lung Cancer (제 1기 비소세포폐암 환자에서 p53 과발현과 예후의 관계)

  • Um, Sang-Won;Kim, Hojoong;Kwon, O Jung;Han, Joungho;Shim, Young Mog
    • Tuberculosis and Respiratory Diseases
    • /
    • v.65 no.6
    • /
    • pp.487-494
    • /
    • 2008
  • Background: Chromosome 17p allele losses and mutations of p53 gene are the most common genetic abnormalities in lung cancer. The purposes of this study were to evaluate the factors associated with p53 protein overexpression and to evaluate its prognostic value in patients with pathologic stage I non-small cell lung cancer (NSCLC). Methods: This is a retrospective review for the patients who underwent surgical resection at Samsung Medical Center between Jan 2003 and Jun 2004. Immunohistochemical staining for p53 protein was performed on tumor tissues from patients with lung cancer. The p53 overexpression was evaluated in relation to age, sex, smoking history, histology and pathologic stage by univariate and multivariate analyses. The disease-free survival (DFS), disease-specific survival (DSS) and overall survival (OS) were analyzed using the Kaplan-Meier methods and the differences in DFS, DSS and OS were assessed by using the log-rank tests. Results: A total of 125 patients were included in the analysis and a median frequency of p53 expression in tumor tissue was 10%. The p53 overexpression (${\geq}10%$) was more common in squamous cell carcinoma (66%) than in adenocarcinoma (38%, p=0.002). The p53 overexpression was more common in pathologic stage IB (59%) than in IA (38%, p=0.002). Patients with p53-overexpressing tumor (27 years) smoked more years compared with those without it (20 years, p=0.032). Smoking history ${\geq}25$ pack-years was more common in patients with p53 overexpression (58%) than in those without it (38%, p=0.024). In the multivariate analysis, only histology was significantly associated with p53 overexpression. However, there were no significant differences of DFS, DSS and OS in relation to p53 status. Conclusion: The p53 overexpression was associated with histology, pathologic stage and smoking history in patients with pathologic stage I NSCLC. However, the p53 overexpression was not associated with patient's survival.