• Title/Summary/Keyword: 방동제

Search Result 8, Processing Time 0.025 seconds

Compressive Strength and Fluidity of Low Temperature Curable Mortar Using High Early Strength Cement According to Types of Anti-freezer, Accelerator for Freeze Protection and Water Reducing Agent (조강형시멘트를 사용한 저온경화형 모르타르의 압축강도 및 유동특성에 미치는 방동제, 내한촉진제 및 감수제의 영향)

  • Park, Jung-Hoon;Ki, Kyoung-Kuk;Lee, Han-Seung;Kim, Hyeong-Cheol;Choi, Hyun-Kuk;Min, Tae-Beom
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.5
    • /
    • pp.405-412
    • /
    • 2016
  • In order to examine the possibility of practical use of concrete at low-temperature environment using high early strength cement with cold resistance admixture, an experimental study on workability, freezing temperature and compressive strength of the mortar with different types of anti-freezer, water reducing agent and accelerator for freeze protection at low-temperature were evaluated. Compressive strength was increased in use of anti-freezer, especially SN anti-freezer was higher than CN anti-freezer. 0min flow was increased, the 20min flow was decreased. And 20min flow was improved in use of FR, RT water reducing agent. CF, LS accelerator for freeze protection, regardless of the type of water reducing agent, compressive strength was increased.

Freezing Temperature Properties of Anti-freeze Agency in Domestic (국내 시판 방동제의 동결온도 특성)

  • Noh, Sang-Kyun;Lee, Gun-Cheol;Cho, Byoung-Young;Kim, Young-Geun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.383-384
    • /
    • 2010
  • This study was investigated freezing temperature measurement method and freezing temperature properties of anti-freeze agency in the domestic. Anti-freeze agency kinds were intended for nitrous acid. Anti-freeze agency with water dilution ratio was showed range of $-4.9{\sim}-6.3^{\circ}C$ in case of 1:3, $-3.3{\sim}-4.2^{\circ}C$ in case of 1:5, $-2.1{\sim}-3.3^{\circ}C$ in case of 1:7.

  • PDF

Study on the Quality Properties of Anti Freeze Agent manufactured in Korea (국내 시판 방동제의 품질 특성에 관한 조사)

  • Lee, Gun-Cheol;Noh, Sang-Kyun;Cho, Byoung-Young;Kim, Young-Geun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.333-334
    • /
    • 2010
  • In this paper, quality variations of commercially available anti-freezers manufactured in Korea are studied. This study is focused on the effect of the use of anti freezer on strength recovery of cement mortar under low curing temperature. As expected, regardless of types of anti freezer, the use of antifreezer protects the water from freezing under low curing temperature.

  • PDF

A Experimental Study on Early Age Compressive Strength of Cement Mortar Using Anti Freezer and Hardening Accelerator at low temperature (방동제와 경화촉진제를 사용한 저온환경하 모르타르의 초기압축강도에 관한 실험적 연구)

  • Kim, Mok-Kyu;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.135-136
    • /
    • 2014
  • In this study, the experimental study on the early age compressive strength of cement mortar using anti freezer and hardening accelerator at low temperature was conducted. For this study, all of materials for experiment were kept in a low temperature for 24 hours before mortar mixing. After mortar curing at low temperature, compressive strength was measured at the early ages. Furthermore, properties of hardened cement material was analysed using TG-DTA and MIP.

  • PDF

Fundamental Properties of Magnesia-Prosphate Composite Considering Mix Conditions and Curing Temperature (배합조건 및 양생온도에 따른 마그네시아 인산염 복합체의 기초물성 평가)

  • Cho, Hyun Woo;Kang, Su Tae;Shin, Hyun Seop;Lee, Jang Hwa
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.6
    • /
    • pp.163-170
    • /
    • 2012
  • With the advantage of a rapid exothermic reaction property, jet set concrete may be used as a cold weather concrete because it can reach the required strength before being damaged by cold weathers. And it can be hardened more quickly if the field temperature is properly compensated by heating. Because ordinary concrete cannot be hardened well under sub-zero temperatures, anti-freeze agents are typically added to prevent the frost damage and to ensure the proper hardening of concrete. While the addition of a large amount of anti-freeze agent is effective to prevent concrete from freezing and accelerates cement hydration resulting in shortening the setting time and enhancing the initial strength, it induces problems in long-term strength growth. Also, it is not economically feasible because most anti-freeze agents are mainly composed of chlorides. Recent studies reported that magnesia-phosphate composites can be hardened very quickly and hydrated even in low temperatures, which can be used as an alternative of cold weather concrete for cold weathers and very cold places. As a preliminary study, to obtain the material properties, mortar specimens with different mixture proportions of magnesia-phosphate composites were manufactured and series of experiments were conducted varying the curing temperature. From the experimental results, an appropriate mixture design for cold weathers and very cold places is suggested.

Properties of Cold Weather Concrete Using Anti-freeze Agent Based Formate-acetate (포름산-아세트산염계 방동제를 사용한 콘크리트의 특성)

  • Jo, Hyun-Tae;Kim, Ho-Soo;Chun, Jun-Young;Ryu, Deuk-Hyun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.617-620
    • /
    • 2008
  • When fresh concrete is exposed to the cold weather, the concrete may happen frost damage because of freezing at early ages and the strength development may be go down. Therefore, this paper is intend to investigate the properties and availabilities of cold weather concrete using anti-freeze based formate-acetate for ensure of excellent concrete quality on cold temperature. According to test result for concrete in anti-freeze agent, strength properties in sub-zero temperature increases in comparison with concrete of non anti-freeze agent without decline of strength until later age. When anti-freezing agent is added by 3.0% to binder, it gives good effects on the performance of the fresh and harden concrete.

  • PDF

The Freezing Temperature of Chemical Admixtures for Concrete and the Quality Vareation of Concrete Using the Frozen Admixtures (콘크리트용 혼화제의 동결온도 및 동결된 혼화제의 사용에 따른 콘크리트의 품질변화)

  • 한천구;한경익;이건철
    • Magazine of the Korea Concrete Institute
    • /
    • v.10 no.4
    • /
    • pp.205-212
    • /
    • 1998
  • Frost damage of a storage tank for chemical admixtures caused by a low temperature in winter and quality deterioration of chemical admixtures have been often reported. However, there have been few regulations and researches related to the frost damage of chemical admixtures and facilities. Therefore, this paper is intend to investigate not only, the freezing points of chemical admixtures such as AE admixtures and water-reducing AE admixtures, etc., but also the quality variation of concrete used with chemical admixtures before freezing and after freeze-thaw cycles. According to the results of experiments, most chemical admixtures except anti-freezing agent and accelerating water-reducing AE admixtures should be kept from being frozen in low winter temperatures. However, full agitation of frozen chemical admixtures dose not cause the problems of concrete related to the quality of chemical admixtures.

Development Ultra Rapid Hardening Construction Materials on Cold Weather Environment Considering Curing Temperature (양생온도를 고려한 극한지용 초속경 건설재료 개발)

  • Cho, Hyun-Woo;Shin, Hyun-Seop;Lee, Jang-Hwa
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.5
    • /
    • pp.59-66
    • /
    • 2013
  • Because ordinary concrete cannot be hardened well under sub-zero temperatures, anti-freeze agents are typically added to prevent the frost damage and to ensure the proper hardening of concrete. With the advantage of a rapid exothermic reaction property, jet set concrete may be used as a cold weather concrete because it can reach the required strength before being damaged by cold weather. Recent studies are reported that magnesia-phosphate composites can be hardened very quickly and hydrated even in low temperature, which can be used as an alternative of severe cold weather concrete in arctic regions. This study developed the magnesia-phosphate composites that can be used in severe cold regions and suggested an appropriate mixture design from the experimental results.