• 제목/요약/키워드: 방냉성능

검색결과 5건 처리시간 0.016초

관외착빙형 빙축열조의 방열성능 모델링 (Modelling of Thermal Discharge Performance for Ice-on-coil Type Ice-Storage Tank)

  • 이상렬;이경호;최병윤;한승호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.280-285
    • /
    • 2001
  • This paper presents a modelling of thermal discharge performance for a static ice-on-coil ice-storage tank. Through the present study, discharging characteristics were examined with the existing results of theoretical and numerical heat transfer analyses. Also, an experiment was conducted to obtain a real set of discharge performance. The thermal effectiveness, the ratio of the actual heat transfer rate to the maximum possible heat transfer rate, decreased when the stored energy decreased during discharging period. And the effectiveness increased as the coolant flow rate through the storage increased, of which increasing rate decreased abruptly near the maximum and the minimum stored energy. An empirical correlation was obtained from the experimental and the numerical analysis data.

  • PDF

냉동트럭용 강제대류방식 PCM 냉동모듈의 방냉성능 최적화에 관한 연구 (The Discharge Performance Optimization of a Forced Convection Type PCM Refrigeration Module Used in a Refrigeration Truck)

  • ;김원욱;이상렬;김용찬
    • 설비공학논문집
    • /
    • 제25권11호
    • /
    • pp.624-630
    • /
    • 2013
  • A truck refrigeration system using phase change material (PCM) is expected to have a lower noise level, reduced energy cost, and much lower local greenhouse gas emission. Recently, a forced convection type PCM refrigeration module has been developed. As the operation time increases, the PCM around the air inlet melts, because of a large temperature difference between the PCM and air. Therefore, the latent heat transfer area decreases and the heat transfer rate of the module decreases even though there is a lot of PCM which does not melt around the air outlet. A computational fluid dynamic modeling of the PCM refrigeration module was developed and validated by the experiment. Using the CFD, the design parameters, such as the mass flow rate of the air and roughness of the slab, were investigated to improve the heat transfer inhomogeneity. As a result, the adoption of partial roughness on the slabs improved the heat transfer inhomogeneity and reduced a fan power.

단일캡슐 축방냉성능을 이용한 캡슐형 빙축열조 모델 (Model of Encapsulated Ice 510 Storage Tanks Using Charge and Discharge Performance of Single Ice Capsule)

  • 이경호;주용진;최병윤;김상준
    • 설비공학논문집
    • /
    • 제12권4호
    • /
    • pp.337-344
    • /
    • 2000
  • The present study describes a one-dimensional modeling of encapsulated ice storage tanks. The thermal transmittance of capsules in this model uses the results from the Arnold's experimental $study^{(2-3)}$.In this model, ice storage tank is partitioned by several control volumes for the analysis, each having same number of capsules. The model is validated by the comparison of the measured data from an ice storage tank installed at a building with the capacity of 1200 ton-hrs and the simulated results with the same inlet brine temperature conditions into the tank.

  • PDF

수중 빙제조형 빙축열시스템의 성능특성 특성 (Experimental Study on the Performance Characteristic in Underwater Harvest-Type Ice Storage System)

  • 장용식;이호생;최인수;김재돌;김은필;윤정인
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.298-303
    • /
    • 2001
  • A fundamental study on the under water harvest-type ice storage system and its temperature characteristics in ice storage system was performed experimentally. The experiments were conducted by changing the inlet refrigerant temperature of an evaporator to analyzing the thermal fluid motion inside the ice storage tank. From the experimental results, the cold storage characteristics were investigated by measuring the axial and radial temperature variations inside the ice storage tank with respect to the inlet and outlet refrigerant temperatures of an evaporator. In case of the under water harvest-type ice storage system, thermal fluid. motion inside the ice storage tank was shown differently in comparison with that of other ice storage systems. During the cooling storage process, there was no supercooling phenomenon in the ice storage tank. These results show the characteristic of this system and the possibility of application to other fields.

  • PDF

밀폐식 빙축열시스템의 축열 및 방열과정에 관한 실험 (Experiment on the Charging and Discharging Processes of a Closed Ice-Thermal-Energy-Storage System)

  • 김경환;윤영환;김연규
    • 에너지공학
    • /
    • 제16권4호
    • /
    • pp.164-169
    • /
    • 2007
  • 우리나라에서 여름철 피크전력부하의 감소는 매우 중요하다. 정부는 피크전력부하를 저감하기 위하여 많은 지원 정책과 법률을 제정하여 시행하고 있다. 그리고 빙축열시스템은 이런 대안 중의 하나로서 알려지고 있다. 이 논문의 목적은 축열운전, 병렬운전과 축열조 단독운전이 수행된 밀폐식 빙축열시스템의 축열조 성능과 전체 효율을 평가하는 것이다. 설계조건에서 운전된 빙축열시스템의 자료를 이용하여 축열조의 축열밀도와 방냉효율 그리고 시스템의 총괄에너지 이용효율을 계산하면 $18.4\;USRT-h/m^3$, 96.2% 그리고 2028.7 kcal/kWh이다. 빙축열시스템의 축열조에 공급되는 에너지를 설계조건보다 많게 공급하면 과냉각효과에 의해 설계조건보다 시스템 효율이 낮게 평가되어진다.