Development of Recycling Technique of Mill Reject Produce using Ttiboelectrostatic Separation (마찰하전형정전선별법을 이용한 Mill Reject 산물 재활용 기술개발)

  • 전호석;한오형;신선명;윤로한
    • Resources Recycling
    • /
    • v.11 no.2
    • /
    • pp.20-27
    • /
    • 2002
  • This study was to develop the triboelectrostatic separation technique to recycle the coal from about 20% of mill reject products remained by grinding process in the coal thermoelectric power plant. In this study, we get a test results that can product the cleaned coal of 15% ash content and 66.23% recovery from mill reject of 47% ash content. And then, from the result of the releases analysis, we proved the excellence of treatment method, after showing the treament processing which is able to get 80% of recovery of coal from 20% of ash content demanded in the power plant.

Regulatory Trend of USA on Nuclear Power Plants and Transmission System (원전과 송전계통의 미국규제동향)

  • Zhu, Oon-Pyo;Kim, Bok-Yeol;Kim, Nam-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.36_37
    • /
    • 2009
  • 2003년 8월14일 북미는 사상최대의 대정전 사고를 경험하였다. 입법과정을 통하여 전기신뢰도기구가 창설되고, 신뢰도 기준을 법제화하는 등 후속조치가 진행되었다. 미국 원자력규제기관은 송전망 관련사건 분석을 통해서 송전망사고가 점차 대형화되어, 소외전원 상실을 비롯한 발전소 교류전원상실이 안전을 위협할 수 있다는 것을 확인하였다. 비록 2003 대정전으로 인한 원전사고는 없었지만, 문제점을 인식하고, 원전연계요건을 포함한 원전-송전계통 사업자 조정 기준을 법제화하여 원전안전성을 보장하도록 하였다. 이와 같이 변화된 규제환경 및 동향과 아울러 전기신뢰도 확보를 비롯한 원전의 안전성을 확보하는 최근 미국 규제기관의 노력을 확인하여 교훈을 얻고져 한다.

  • PDF

Study on the Safety Analysis on the Cooling Performance of Hybrid SIT under the Station Blackout Accident (발전소 정전사고 시 Hybrid SIT의 냉각성능 평가를 위한 안전해석에 관한 연구)

  • Ryu, Sung Uk;Kim, Jae Min;Kim, Myoung Joon;Jeon, Woo Jin;Park, Hyun-Sik;Yi, Sung-Jae
    • Journal of Energy Engineering
    • /
    • v.26 no.3
    • /
    • pp.64-70
    • /
    • 2017
  • The concept of Hybrid Safety Injection Tank (Hybrid SIT) proposed by the Korea Atomic Energy Research Institute (KAERI) has been introduced for the purpose of application to the Advanced Power Reactor Plus (APR+). In this study, the SBO situation of the APR+ was analyzed by using the MARS-KS code in order to evaluate whether the operation of the Hybrid SIT has an effect on the cooling performance of the Reactor Coolant System (RCS). According to the analysis, when the actuation valve on the pressure balancing line (PBL) is opened, the Hybrid SIT's pressure rises rapidly, forming equilibrium with the RCS pressure; subsequently, a flow is injected from the Hybrid SIT into the reactor vessel through the direct vessel injection (DVI) line. The analysis showed that it is possible to keep the core temperature below melting temperature during the operation of a Hybrid SIT.

A Buoyant Combined Solar-Wave Power Generation and Its Application for Emergency Power Supply of Nuclear Power Plant (부유식 태양광-파력 복합발전 개념 및 원자력발전소 비상전원을 위한 응용)

  • Cha, Kyung-Ho;Kim, Jung-Taek
    • New & Renewable Energy
    • /
    • v.7 no.4
    • /
    • pp.37-41
    • /
    • 2011
  • This paper presents a Combined solar-wave Power Generation (CPG) concept that the CPG unit is maintained as buoyant at the level of sea water and it is also supported by a submerged tunnel, with the aim of supplying emergency electric power during the station blackout events of nuclear power plants. The CPG concept has been motivated from the 2011 Fukushima-Daiichi Accidents due to the loss of both offsite AC power and emergency diesel power caused by natural hazards such as earthquake and tsunami. The CPG is conceptualized by applying different types and different sites for emergency power generation, in order to reduce common cause failures of emergency power suppliers due to natural hazards. Thus, the CPG can provide a new mean for supplying emergency electric power during station blackout events of nuclear power plants. For this application, the CPG requirements are described with a typical configuration at the ocean side of a submerged tunnel.

시선집중, 안전경영 우수기업 - 철저한 안전관리 바탕으로 발전설비 명가로 우뚝, 한전 KPS(주) 서인천사업처

  • Kim, Seong-Dae
    • The Safety technology
    • /
    • no.195
    • /
    • pp.18-20
    • /
    • 2014
  • 전국 산업현장 어디에서나 안전은 중요하게 여겨진다. 하지만 안전이 더욱 각별하게 다가오는 곳이 있다. 바로 국가 산업의 기초가 되는 금속공업, 화학공업 등 국가기반산업 현장이 그곳이다. 이 가운데 특히 전력산업에서 안전은 한 나라의 경제와 사회를 좌지우지할 만큼 엄청난 영향을 미친다. 지난 2011년 9월 15일 발생한 대정전 사태를 생각해보면 쉽게 이해가 갈 것이다. 이에 따라 발전소의 안전운행을 위해 정비 및 유지 보수 등의 업무를 수행하는 한전KPS(주) 서인천 사업처에서는 남다른 안전관리활동을 전개하고 있다. 이곳에서 어떻게 안전을 확보해 나가고 있는지 살펴봤다.

  • PDF

A Study on the Design Parameters of the Static Ring in the Ultra-high Voltage Non-uniform Electric Field (초고압 불평등 전계에서 정전링 설계변수에 대한 연구)

  • Kim, Jin-Sung;Seo, Min-Seong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.7
    • /
    • pp.577-582
    • /
    • 2020
  • Electricity produced at power plants is distributed to consumers through several stages of substations. At this time, an ultra-high voltage transformer is needed in the initial transmission stage to transmit a voltage suitable for each consumer. A high voltage, non-uniform electric field is formed at the end of the winding of the ultra-high voltage transformer, which carries a risk of dielectric breakdown. The winding of the ultra-high voltage transformer is an electrode, which is the key to converting the magnitude of the voltage. A non-uniform electric field is formed along the shape of the winding end, resulting in high electrical stress. The static ring installed at the upper and lower ends of the winding is used to disperse the stress at the winding end. Several variables should be considered when designing a static ring. Among them, this study examined how the curvature of the static ring, the thickness of the insulating paper, the number of barriers, and barrier thickness affect the electrical stress of the static ring using the Finite Element Method. Suggestions to be considered when designing the static ring are proposed through the FEM results.

Separation of Unburned Carbon from Coal Fly Ash Using and Electrocyclone (電氣빠이클론을 이용한 石炭灰 중 미연탄소 저감기술 開發)

  • 조희찬;김정윤
    • Resources Recycling
    • /
    • v.10 no.3
    • /
    • pp.14-22
    • /
    • 2001
  • For the recycle of coal fly ash generated from power stations, we developed an electrocyclone system which can separate unburned carbon form coal fly ash, based on the fact that coarse fly ash particles contain higher amount of unburned carbon and unburned carbon particles are charged positively, and pure ash particles are charged negatively on contacting each other. Additionally, guide vanes were installed in the cyclone to control the cut size. Two types of electrode, stick and grid type, were designed to investigate the effect of electrode type. Results show that by introducing an electric field inside the cyclone, the yield increases by 5 to 15e1o. But the content of unburned carbon in the clean ash does not change significantly.

  • PDF

Development of New Techniques of Electrostatic Separation for Using of Clean Coal (청정석탄(淸淨石炭) 이용(利用)을 위한 정전선별(靜電選別) 기술개발(技術開發))

  • Baek, Sang-Ho;Jeon, Ho-Seok;Han, Oh-Hyung
    • Resources Recycling
    • /
    • v.14 no.5 s.67
    • /
    • pp.54-61
    • /
    • 2005
  • In 2006, the coal usage that is used as energy source of power plant will meet 16,000 MW which is 30% of the whole energy usage. A Coal deposits among the fossil fuels is very plentiful in natural resources and has high economical efficiency but application technique is very inconvenient. Also when burned for utilization, it generate various toxic and untoxic air pollution materials; fly ash, bottom ash, sulfurous acid gas etc. In this study, we could establish a preparation of clean coal by triboelectrostatic separation. In this study, we made a bench-scale's triboelectrostatic separation equipment using electrostatic technology, and got an optimum conditions of various factors for increasing recovery rate and purification in separation. A test result, we got a clean coal that recovery rate is 68.10%, rejection rate of ash and sulfur content is 31.23% and 28.33%.

A Study on Peak Load Prediction Using TCN Deep Learning Model (TCN 딥러닝 모델을 이용한 최대전력 예측에 관한 연구)

  • Lee Jung Il
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.12 no.6
    • /
    • pp.251-258
    • /
    • 2023
  • It is necessary to predict peak load accurately in order to supply electric power and operate the power system stably. Especially, it is more important to predict peak load accurately in winter and summer because peak load is higher than other seasons. If peak load is predicted to be higher than actual peak load, the start-up costs of power plants would increase. It causes economic loss to the company. On the other hand, if the peak load is predicted to be lower than the actual peak load, blackout may occur due to a lack of power plants capable of generating electricity. Economic losses and blackouts can be prevented by minimizing the prediction error of the peak load. In this paper, the latest deep learning model such as TCN is used to minimize the prediction error of peak load. Even if the same deep learning model is used, there is a difference in performance depending on the hyper-parameters. So, I propose methods for optimizing hyper-parameters of TCN for predicting the peak load. Data from 2006 to 2021 were input into the model and trained, and prediction error was tested using data in 2022. It was confirmed that the performance of the deep learning model optimized by the methods proposed in this study is superior to other deep learning models.

The Development of Pulverized Coal(PC) Flow-Meter using Capacitance (정전용량을 이용한 미분탄 유량계의 개발)

  • Gim, Jae-Hyeon;Lee, Yong-Sik;Hwang, Keon-Ho;Jeong, Sung-Won;Yeo, Jun-Ho;So, Ji-Young
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.4
    • /
    • pp.61-67
    • /
    • 2008
  • In this papar, the flow meter system for pulverized coal is developed for the pulverizer-burner system of the boiler or the blast furnace. The sensor of the system a lied the capacitance with a pair of electrode on the outer wall of the electric insulator pipe. The circuit is designed for the measurement of the granule flow density combining as a measuring electrode and a reference. In order to measure granule-flow density, the calibration curve between the weight measured from loadcell and the voltage from the circuit is created. It is verified that the flow meter system has reliability and accuracy using on-line test.