• Title/Summary/Keyword: 발산율

Search Result 54, Processing Time 0.02 seconds

600MW(e) CANDU PHTS Flow Instability and Interconnect Effect

  • Won Jae Lee;Jin Soo Kim;Goon Cherl Park
    • Nuclear Engineering and Technology
    • /
    • v.17 no.4
    • /
    • pp.290-301
    • /
    • 1985
  • 600MW(e) CANDU Primary Heat Transport System (PHTS) is composed of the two “figure-of-eight” loops and is designed to operate with the 4% Reactor Outlet Header (ROH) quality at its rated power. This existence of the two compressible regions and the positive flow-qualitly-void feedbacks are the sources of the PHTS flow instability. To ensure the PHTS stability, ROH-ROH interconnect pipes are installed as passive systems. This paper describes the investigation of the PHTS flow instability at its design full power condition. Also studied are the interconnect effect and the inherent system damping effect on the system stability. The time domain stability analyses are accessed by using the ATHER/MOD-I code which is the improved version of the KAERI developed ATHER code. Under the most adverse system modelling, the “figure-of-eight” symmetric loop shows divergent flow oscillations. Under with the interconnect, the PHTS stability is remarkably enhanced so that the system becomes stable. However, even under the conservative pressurizer modelling, the PHTS shows the more convergent flow oscillations. With the interconnect and the pressurizer modelling, its stability is highly credited. Conclusively, the inherent system damping by pressurizer itself can credit the PHTS stability without the interconnect.

  • PDF

Synthesis of Multi-Terminalized Magnetic-Cored Dendrimer for Adsorption of Chromium and Enhancement of Magnetic Recovery (크롬 흡착 및 자성회수율 향상을 위한 멀티터미널 자성코어 덴드리머의 합성)

  • Yeo, In-Hwan;Jang, Jun-Won;Kim, Lyung-Joo;Park, Jae-Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.9
    • /
    • pp.613-622
    • /
    • 2012
  • A chrome absorbent that is useful in rapid magnetic recovery and recycling was developed though a synthesis of Multi-Terminalized Magnetic-core Dendrimer (MTMD). Divergence through coprecipitation and rotation growth was used for synthesis. The dendrimer was multi-terminilized through methyl propionate and glutaric acid. The property analysis of the synthesized sample was performed through XRD, FT-IR, TEM, EDS, TGA and zeta potential analyzer. A magnetic-core of MTMD had a magnetite crystal and the size of 4th generation dendrimer was identified to be from 15 nm to 20 nm. Through the analysis of the TGA, the rate of the dendrimer branch for the first generation dendrimer was about 7% and 3% of diminished weight occurred as the generation grows. Also, the potential of the dendrimer when multi-terminalized, had variation from 25.26 mV to -6.53 mV. As a result of MTMD adsorption experiment, it absorbed more than 80% within 5 minutes and indicated absorptivity of 6.308 mg/g. When it was compared with COOH Dendrimer (COOH-D) after magnetic recovery, the recovery time was rapidly reduced by more than half and it could recover 100% within 30 minutes. In case of the regeneration experiment that used chrome, it was identified to maintain the same adsorptivity for four runs.

Outlook on Variation of Water Resources in Korea under SRES A2 Scenario (A2 시나리오에 따른 국내 수자원의 변동성 전망)

  • Bae, Deg-Hyo;Jung, Il-Won;Lee, Byong-Ju
    • Journal of Korea Water Resources Association
    • /
    • v.40 no.12
    • /
    • pp.921-930
    • /
    • 2007
  • The objective of this study is to present temporal-spatial variation of water resources on climate change impacts using the IPCC SRES A2 scenario and dynamical downscaling of the results (using the MM5 model with a resolution of 27km by 27km) at 139 sub-basins in Korea. The variation of runoff shows differences in the change of rate according to the each sub-basins and analysis durations. It has increased in the sub-basins located in Han river basin and east part of it, the other basins have decreased. In seasonal analysis, runoff in autumn and winter have increased, while in spring and summer have decreased. The results of frequency analyzing classified runoff(Low flow(Q$\leq$5mm), Normal flow(5$\geq$100mm)) show that low flow increase in most of the sub-basins for 2031-2060 and 2061-2090. In the case of high flow, it have higher frequency ranging from -100% to 500% than low flow. Regardless of the variation of mean runoff, maximum discharge appeared to be increase in process of time. The regression method is used to figure out the relationship between the rate of runoff change and mean temperature, mean precipitation under A2 scenario. The mean actual evapotranspirations from the regression equations increased by 3.4$\sim$5.3% for the change of $1^{\circ}C$. Also, for the precipitation change of $\pm$10%, runoff variety range is -18.2$\sim$+12.4% in Han River, -21.6$\sim$+14.6% in Nakdong River, -17.5$\sim$+11.5% in Gum River, -18.4$\sim$+10.6% in Sumjin River, -19.9$\sim$+12.7% Youngsan River basin.

The Characteristics of Retention and Evapotranspiration in the Extensive Greening Module of Sloped and Flat Rooftops (저토심 경사지붕과 평지붕 녹화모듈의 저류 및 증발산 특성)

  • Ryu, Nam-Hyong;Lee, Chun-Seok
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.41 no.6
    • /
    • pp.107-116
    • /
    • 2013
  • This study was undertaken to investigate the characteristics of retention and evapotranspiration in the extensive greening module of sloped and flat rooftops for stormwater management and urban heat island mitigation. A series of 100mm depth's weighing lysimeters planted with Sedum kamtschaticum. were constructed on a 50% slope facing four orientations(north, east, south and west) and a flat rooftop. Thereafter the retention and evapotranspiration from the greening module and the surface temperature of nongreening and greening rooftop were recorded beginning in September 2012 for a period of 1 year. The characteristics of retention and evapotranspiration in the greening module were as follows. The water storage of the sloped and flat greening modules increased to 8.7~28.4mm and 10.6~31.8mm after rainfall except in the winter season, in which it decreased to 3.3mm and 3.9mm in the longer dry period. The maximum stormwater retention of the sloped and flat greening modules was 22.2mm and 23.1mm except in the winter season. Fitted stormwater retention function was [Stormwater Retention Ratio(%)=-18.42 ln(Precipitation)+107.9, $R^2$=0.80] for sloped greening modules, and that was [Stormwater Retention Ratio(%)=-22.64 ln(X)+130.8, $R^2$=0.81] for flat greening modules. The daily evapotranspiration(mm/day) from the greening modules after rainfall decreased rapidly with a power function type in summer, and with a log function type in spring and autumn. The daily evapotranspiration(mm/day) from the greening modules after rainfall was greater in summer > spring > autumn > winter by season. This may be due to the differences in water storage, solar radiation and air temperature. The daily evapotranspiration from the greening modules decreased rapidly from 2~7mm/day to less than 1mm/day for 3~5 days after rainfall, and that decreased slowly after 3~5 days. This indicates that Sedum kamtschaticum used water rapidly when it was available and conserved water when it was not. The albedo of the concrete rooftop and greening rooftop was 0.151 and 0.137 in summer, and 0.165 and 0.165 in winter respectively. The albedo of the concrete rooftop and greening rooftop was similar. The effect of the daily mean and highest surface temperature decrease by greening during the summer season showed $1.6{\sim}13.8^{\circ}C$(mean $9.7^{\circ}C$) and $6.2{\sim}17.6^{\circ}C$(mean $11.2^{\circ}C$). The difference of the daily mean and highest surface temperature between the greening rooftop and concrete rooftop during the winter season were small, measuring $-2.4{\sim}1.3^{\circ}C$(mean $-0.4^{\circ}C$) and $-4.2{\sim}2.6^{\circ}C$(mean $0.0^{\circ}C$). The difference in the highest daily surface temperature between the greening rooftop and concrete rooftop during the summer season increased with an evapotranspiration rate increase by a linear function type. The fitted function of the highest daily surface temperature decrease was [Temperature Decrease($^{\circ}C$)=$1.4361{\times}$(Evapotranspiration rate(mm/day))+8.83, $R^2$=0.59]. The decrease of the surface temperature by greening in the longer dry period was due to sun protection by the sedum canopy. The results of this study indicate that the extensive rooftop greening will assist in managing stormwater runoff and urban heat island through retention and evapotranspiration. Sedum kamtschaticum would be the ideal plant for a non-irrigated extensive green roof. The shading effects of Sedum kamtschaticum would be important as well as the evapotranspiration effects of that for the long-term mitigation effects of an urban heat island.