• Title/Summary/Keyword: 반응보정인자

Search Result 30, Processing Time 0.01 seconds

Study on the Characteristics of Response Correction Factor of Ionization Chamber in RW3 Solid Phantom for High Energy X-rays (RW3 고체팬텀에서 고에너지 X-선에 대한 전리함 반응보정인자의 특성에 관한 연구)

  • Lee, Jeong-Ok;Jeong, Dong-Hyeok;Kim, Bu-Gil
    • Journal of radiological science and technology
    • /
    • v.32 no.2
    • /
    • pp.205-212
    • /
    • 2009
  • The response correction factor ( h) is a factor to convert the response of the chamber in solid phantom to the response in water. In RW3 solid phantom, the dependency of beam quality and depth for high energy X-rays are known characteristics, however the dependency of field size, SSD, and chamber type are unknown. In this work we have studied the unknown characteristics on the dependency of response correction factor. The farmer type chamber (FC65G) and small chamber (CC13) were used and two beam qualities of 6 and 15 MV were evaluated. The measured response correction factors at the depth of 5 cm and 10 cm were h = 1.015 and 1.021 for 6 MV X-rays, and h = 1.024 and 1.029 for 15 MV X-rays. In conclusion the response correction factor did not depend on the field size and SSD while depending on the beam quality and depth. In the chambers, there are small differences between the two chambers used in this study but we think additional study for more chambers should be required. The results in this study can be used for analyzing the measured values from ionization chamber dosimetry in RW3.

  • PDF

Element Correction Method of Thermoluminescent Dosimeters (개인 피폭선량계 소자 보정법)

  • 송명재
    • Progress in Medical Physics
    • /
    • v.2 no.1
    • /
    • pp.17-28
    • /
    • 1991
  • Generally, it is an accurate radiation measurement technique for processors fo thermoluminescent dosimenters(TLDs) to characterize each element they use by producing element correction factors(FCFs). TLDs are classified into three groups such as reference. control, and field TLDs. Reference TLDs are used only for the production of ECFs for the control and field TLDs. They are kept locked in a safe place except when it is necessary to use a subset of them to produce ECFs for the control and field TLDs. The ECF of a given element is a measure of the response of the element relative to the mean response of an arbitrarily selected group of reference elements. As TLDs are used in the field, their relative responses to radiation might be decreased due to muliple readings and physical abuse. Therefore, the producditon of ECFs are performed initially and periodically during the field use. This element correction method provides an excellent tool to examine new TLDs and to monitor the reliability of old TLDs. This paper discuss the 10 step procedures developed to produce and examine ECFs.

  • PDF

Correction Factor for the Eenergy Dependence of a Optically Stimulated Luminescent Dosimeter in Diagnostic Radiography (진단방사선촬영에서 광자극형광선량계의 에너지의존성에 대한 보정인자)

  • Kim, Jong-Eon;Im, In-Chul;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.5
    • /
    • pp.261-265
    • /
    • 2011
  • The purpose of this study is to calculate correction factors for energy dependence of a nanoDotdosimeter to measure patient's skin dose in diagnostic radiography. The correction factors were calculated by using the values of mean energy for the RQR standard radiation qualities of IEC publicated by Rosado et al. and the energy response graph of dosimeter relative X-ray on phantom calibration provided by landaur corporation. Results showed the correction factors of 1-1.33 over the tube voltage range of 40-50 kVp. Acquired correction factors are considered to be useful in the clinics for the measurement of accurate skin dose at each tube voltage.

Measurement of ECF for $CaSO_4:Dy$ Thermoluminescent Dosimeters ($CaSO_4:Dy$ 열형광선량계의 소자보정인자(ECF) 산출)

  • Lim, Kil-Sung;Kim, Jang-Lyul
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.4
    • /
    • pp.231-236
    • /
    • 2005
  • Dosimeters are manufactured from same process in the manufacturer but the deviation of TL raw counts exists among the dosimeters. TL raw counts are also gradually degrade due to multiple readings and physical abuse. ECF (Element Correction Factor) correct the degradation and deviation of TL raw counts to the average TL raw counts of reference dosimeters. Procedures for producing ECF of thermoluminescent dosimeters were described In detail. ECFs of 319 reference, control and field dosimeters were measured three times and average of three ECF values was calculated. Also, % CV(Coefficient of Variation) of three ECF values was calculated to verify ECF. ECF & % CV distributions for the field and control dosimeters are presented. TL raw counts of field dosimeters, being used about 6 times for the past 3 years, were almost unchanged, but those of control dosimeters being used more frequently, were degraded about 4.7 %.

Three-dimensional Sensitivity Analysis of Dynamic Agricultural Nonpoint Source Assessment Tool (DANSAT) (동적 농업 비점오염 평가모델 (DANSAT)의 3차원 민감도 분석)

  • Cho, Jae-Pil;Hwang, Sye-Woon;Saied, Mostaghimi
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.51 no.1
    • /
    • pp.41-52
    • /
    • 2009
  • 새로 개발된 모형에 대한 민감도 분석은 입력변수의 선정 및 보정을 위한 필요한 지침을 제공하기 위해 수행되어야 할 필수적인 과정이다. 동적 농업비점오염 평가모델 (dynamic agricultural nonpoint source assessment tool, DANSAT)은 농업 최적관리기법(BMP)의 지표 및 지하수에 대한 영향을 평가하기 위해 개발된 3차원 모델이다. 본 연구의 목적은 서로 다른 토층 및 유역내 위치에서 입력변수의 변화에 따른 지표 및 지하관련 출력들의 반응을 토대로 DANSAT의 일반적인 민감도 분석을 수행하는 것이다. 선정된 입력변수들의 변화에 따른 세가지의 지표관련 출력 (유출량, 유사량, 유출수중 농약 부하량) 및 두가지의 지하관련 출력 (지하수로의 유입 유량 및 지하수로의 농약 유입량)의 반응이 고려되었다. 민감한 입력변수들은 하나의 격자만을 이용한 예비 민감도 분석을 통하여 선정되었는데, 대체로 토양 관련 인자들이 지표 및 지하에서 양적/질적으로 민감하게 작용하는 것으로 나타났다. 예비민감도 분석을 통해 선정된 토양입력변수들의 서로 다른 토층에서의 변화에 따른 모형 출력들의 반응을 고려한 수직적 민감도 분석결과, 지표관련 출력들의 경우 지표 부근의 상층 토양의 인자가, 지하관련 출력들의 경우 하부 토층의 인자가 각각 민감하게 작용하는 것으로 평가되었다. 유역내에서 입력변수들의 공간적 위치의 변화에 따른 반응을 고려하는 수평적 민감도 분석결과, 유역 경계의 주변보다 하천 주변에서의 입력변수 변화가 모형의 지표 및 지하관련 출력들에 민감한 것으로 나타났다. 본 연구 결과는 BMP의 지표 및 지하의 수문/수질에 미치는 영향을 평가하기 위해 개발된 DANSAT 모형의 입력변수 선정 및 보정에 유용한 자료로 활용될 것으로 기대된다.

Subcriticality Evaluation Using the Modified Neutron Source Multiplication Method (개선된 중성자 선원 증배법을 이용한 미임계도 평가)

  • Yoon, Seok-Kyun;Naing, Win;Kim, Myung-Hyun
    • Journal of Energy Engineering
    • /
    • v.16 no.4
    • /
    • pp.155-163
    • /
    • 2007
  • To insure nuclear reactor safety, the reactivity of control rods should be calculated by measuring the criticality of reactor core and it is regularly performed during the annual physics test period. Also, the core criticality should be monitored during the start-up operation to avoid reactivity induced accidents. Many research works on control rod reactivity measurement and subcriticality measurement have been accomplished throughout the world for decades and recently a new method named "Modified Neutron Source Multiplication Method (MNSM)" was proposed in Japan which is known to be improved overcoming limitations of traditional Neutron Source Multiplication Method (NSM). In this study, MNSM was tested in calculation of subcriticalities and in evaluation of application validity using the educational reactor in Kyung Hee University, AGN-201. For this study, a revised nuclear data library and a neutron transport code system TRANSX - PARTISN were established. Correction factors for various control rod positions were produced using the k-effective values and the corresponding flux distributions and adjoint flux distributions. Experimental values of the core criticality were obtained using the neutron count rates of the BF3 proportional counters. The results showed that the expected reactivity worth of control rods by MNSM agreed well with the theoretical values and the correction factors contributed much for this purpose.

Kinetics of Catalytic Reactions Occurring in a Small Reaction Volume (작은 반응 매질에서 일어나는 촉매 반응 속도에 관한 연구)

  • Kim, Jung-Han;Sung, Jae-Young
    • Journal of the Korean Chemical Society
    • /
    • v.52 no.3
    • /
    • pp.217-222
    • /
    • 2008
  • We investigate the kinetics of diffusion-influenced catalytic reactions occurring in small reaction volume. From a simple exact model study, we find that the reaction rate coefficient decreases with the size of reaction volume. The explicit expression for the average reaction rate constant is presented, which can be regarded as a generalization of well-known Collins-Kimball rate constant into the reactions occurring in a small reaction volume. It turns out that the traditional diffusion influenced reaction dynamics is followed by a single exponential relaxation phase with a rate constant dependent on the reaction volume for the catalytic reactions occurring in small reaction volumes.

A Study on the Transducer Calibration for Acoustic Emission Measurement (AE 측정을 위한 탐촉자의 보정에 대한 고찰)

  • 김교원
    • The Journal of Engineering Geology
    • /
    • v.6 no.2
    • /
    • pp.53-58
    • /
    • 1996
  • In order to investigate the source mechanism of micro cracks through acoustic emission measurement induced by rock fracture, careful calibration of the entire linkage of the detecting system, from the transducers to transient recorder, is an essential requirement prior to testing. Transducers and digitiging system are generally the weakest links in the measurement system because they must translate mechanical motions into digital electric signals. In this study, PAC piezoelectric pressure transducers are calibrated with a standard NBS conical shaped displacement transducer and a DG piezoelectric displacement transducer. The NBS and PAC transducers are insensitive to changes in horizontal impingement angle but sensitive to changes in incident angle. The ray path along the logitudinal axis of the tranducer produced a maximum response while the ray path perpendicular to the transducer axis gave a minimum. And a difference in individual transducers factor for a peak-to-peak amplitude of PAC transducers was within 40%. An average PAC transducer coefficient was determined as 77mv/pm by an absolute calibration test using NBS transducer.

  • PDF

The Collection of Atmospheric Sulfur Gases Using Tedlar Bag: Preliminary Study for the Application of Correction Factors (테들러 백을 이용한 대기 중 황성분의 채취: 보정인자의 적용을 위한 예비연구)

  • Lim, Gye-Gyu;Kim, Ki-Hyun
    • Journal of the Korean earth science society
    • /
    • v.25 no.4
    • /
    • pp.265-269
    • /
    • 2004
  • 본 연구에서는 대기 중 황성분을 채취하는데 가장 널리 활용되는 방법 중의 하나인 테들러 백 방식의 채취와 관련된 오차요인을 여러 가지 관점에서 검정하고자 하였다. 이를 위해, 표준시료를 백과 백간에 이동시켜 주므로서, 백의 벽면을 통해 초래될 수 있는 성분별 손실율을 비교하였다. 상대습도 0 %, 실온 조건에서 실험한 결과, 황화수소와 멀캡턴과 같은 성분들은 백과의 접촉이 일어나면서, 20 %에 가까운 손실율이 확인되었다. 반면, 상대적으로 이들에 비해 반응성이 높지 않은 DMS, DMDS와 같은 성분들도 10 %내외의 손실율이 확인되었다. 이들 성분의 정확한 정량을 위해서는 테들러 백의 흡착손실 등에 대한 특성을 정확하게 파악하는 것이 중요하다. 특히, 습도나 온도와 같은 환경조건의 변화에 대한 고려도 동시에 수반되어야 할 것이란 점을 확인할 수 있었다.

The Effect of Temperature with Substrate and Sludge Adaptation on Biological Phosphorus Release (생물학적 인 방출시 유기물 및 슬러지 적응에 따른 온도의 영향)

  • Min, Kyung-Kook;Weon, Seung-Yeon;Park, Seung-Kook;Lee, Sang-Ill
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.7
    • /
    • pp.1205-1212
    • /
    • 2000
  • The effect of temperature on the sources of organic acids and sludge when phosphorus was biologically released was evaluated in this study. The sludge used in this study was obtained from sequencing batch reactor processing the swine wastewater. Temperature is one of the most important parameters influencing the phosphorus release. As a result, the rate of phosphorus released was increased as the temperatures were increased from 5 to $30^{\circ}C$ regardless of the sources of organic acids used. Under anaerobic conditions, as acetate, propionate, glucose, and domestic wastewater were used as the sources of organic acids, the corresponding activation energy($E_a$) values were 49.83, 55.82, 54.61, and 45.44 KJ/mol, respectively. Temperature coefficient($\theta$) values were 1.0676, 1.0826, 1.0748, and 1.0698, respectively. Therefore, the rate of phosphorus released was increased as temperature was increased, whereas, the effect, of the sources of organic acids and temperature on the activation energy and temperature coefficient values were minimal. When the sludge previously adapted to acetate as external organic source was used, the activation energy and temperature coefficient values were 44.94 KJ/mol and 1.0570 respectively. The effect of temperature was minimal. These values obtained from the sludge previously adapted to acetate were smaller than those from the sludge not previously adapted to the same organic acid. This suggest that the sludge previously adapted to acetate was less dependent on temperature than that not adapted to the acetate.

  • PDF