• Title/Summary/Keyword: 반사측정법

Search Result 383, Processing Time 0.025 seconds

Index of refraction measurement using the reflection characteristics of terahertz electromagnetic pulses (테라헤르츠 전자기 펄스의 반사특성을 이용한 굴절률 측정)

  • 전태인
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.1
    • /
    • pp.1-4
    • /
    • 2001
  • Via terahertz (THz) reflection radar, the characterizations of reflected THz electromagnetic pulses are reported. Quasi-optical techniques are used to efficiently reflect pulses of THz electromagnetic radiation from an aluminum mirror and several conducting and nonconducting materials. An incident THz pulse is reflected up to 9 times to know the magnitude change of a reflected pulse from the aluminum mirror. Using this method, aluminum board, undoped silicon, quartz, and LDPE samples' reflection coefficient and index of refraction can be measured. These results suggest a possible application of transient THz reflection spectroscopy without surface contact.ontact.

  • PDF

Measurement of Reflection Patterns inside Automotive Cabin (차량의 실내 반사음패턴 측정기법)

  • 두세진
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1998.06e
    • /
    • pp.11-14
    • /
    • 1998
  • 근접 4점법을 이용하여 음원으로부터 측정점까지 음파가 전달되어 오는 공간상의 반사음 패턴을 구할 수 있다. 그러나 차량과 같이 협소한 공간에서는 반사음간의 시간차가 매우 작게 되고 따라서 단지 몇 개의 초기 반사음을 제외하고는 측정이 어렵게 된다. 본 연구에서는 측정에 사용된 스피커의 특성을 역필터링하여 차실 내의 펄스 반사음 자체 특성만을 추출함으로써 좁은 공간에서도 반사음 패턴의 측정이 가능하도록 하였다. 실내 반사음 패턴은 음파의 경로를 보여 주는 것이므로 본 측정법은 차량의 실내 음향 특성 파악과 음질 개선에 중요한 도구로 활용될 수 있다.

  • PDF

Ultrasonic Velocity Measurements of Engineering Plastic Cores by Pulse-echo-overlap Method Using Cross-correlation (다중 반사파 중첩 자료의 상호상관을 이용한 엔지니어링 플라스틱 코어의 초음파속도 측정)

  • Lee, Sang Kyu;Lee, Tae Jong;Kim, Hyoung Chan
    • Geophysics and Geophysical Exploration
    • /
    • v.16 no.3
    • /
    • pp.171-179
    • /
    • 2013
  • An automated ultrasonic velocity measurement system adopting pulse-echo-overlap (PEO) method has been constructed, which is known to be a precise and versatile method. It has been applied to velocity measurements for 5 kinds of engineering plastic cores and compared to first arrival picking (FAP) method. Because it needs multiple reflected waves and waves travel at least 4 times longer than FAP, PEO has basic restriction on sample length measurable. Velocities measured by PEO showed slightly lower than that by FAP, which comes from damping and diffusive characteristics of the samples as the wave travels longer distance in PEO. PEO, however, can measure velocities automatically by cross-correlating the first echo to the second or third echo, so that it can exclude the operator-oriented errors. Once measurable, PEO shows essentially higher repeatability and reproducibility than FAP. PEO system can diminish random noises by stacking multiple measurements. If it changes the experimental conditions such as temperature, saturation and so forth, the automated PEO system in this study can be applied to monitoring the velocity changes with respect to the parameter changes.

레이저 표면 거칠기 측정에서 가중 함수에 의한 반사광 성분의 블렌딩

  • 서영호;안중환
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.171-171
    • /
    • 2004
  • 반사광은 표면에 대한 다양한 정보를 포함하고 있다. 반사광 속에서 표면의 거칠기 정보를 알아내 기 위한 노력이 계속되었고, 이를 통해 여러 표면 거칠기 측정법 중에서도 인프로세스 측정에 큰 장 점이 있는 것으로 밝혀졌다. 알려진 바로는 하나의 반사광을 정반사 성분와 난반사 성분으로 구분할 수 있으며 정반사 성분은 광 강도가, 난반사 성분은 광 분포가 중요하다. 매끈한 면에서는 정반사 성분이 지배적이며, 거친 면에서는 난반사 성분이 지배적이고, 그 중간 단계의 면에서는 두 성분이 합해져서 동시에 나타난다.(중략)

  • PDF

중성자 산란을 이용한 나노기공 측정

  • 최성민;이지환;조성민
    • Proceedings of the Korea Crystallographic Association Conference
    • /
    • 2002.11a
    • /
    • pp.51-51
    • /
    • 2002
  • 나노기공물질은 특정 기반물질(matrix) 내부에 대략 나노미터크기의 기공을 함유하고 있는 물질이며 나노기공물질의 특성은 기반물질의 특성과 더불어 기공의 형태, 크기, 분포에 의해서 결정된다. 나노기공물질의 기공에 대한 정보를 측정하는 방법으로는 TEM, 흡착법, FE-SEM과 더불어 중성자 또는 X-ray 빔의 산란을 이용하는 소각중성자산란 (Small-Angle Neutron Scatering, SANS), 소각 X-ray 산란 (Small-Angle X-ray Scattering, SAXS), 중성자반사율측정 (Neutron Relfectimetry, NR), X-ray 반사율측정 (X-Ray Reflectometry, XRR) 등이 사용되고 있다. 본 발표는 대략 1 nm - 100 nm 영역의 bulk 구조와 층상구조를 측정할 수 있는 소각 중성자 산란과 중성자 반사율 측정기법을 이용한 나노기공 측정기술을 다룬다.

  • PDF

Microwave Reflective Properties of Carbon Fiber-Epoxy Composites (탄소섬유-에폭시 복합재료의 전파반사 특성)

  • Kim, Seong-Su
    • Korean Journal of Materials Research
    • /
    • v.8 no.2
    • /
    • pp.161-164
    • /
    • 1998
  • 탄소섬유-에폭시 복합재료의 전파 반사특성을 전파전송 이론에 근거하여 해석하였다. 탄소섬유 복합재료의유전상수를 투과/반사법에 의해 4-12GAz 주파수 범위에서 측정하였다. 측정된 재료정수로부터 반사손실을 시편의두께와 주파수의 함수로 계산하였다. 탄소섬유 복합재료는 높은 유전상수와 도전손실 특성에 의해 전파의 반사율이 매우 높았다. 그러나 파장에 비해 시편의 두께가 작은 경우 반사손실은 두께에 매우 민감하였으며, 이는 입력 임피던스의 변화에 기인하는 것으로 해석되었다. 이러한 결과로부터 전자파 차폐를 극대화시키기 위해서는 특히 저주파 대역에서 시편의두께 조절이 매우 중요함을 제시할 수 있었다.

  • PDF

Measurement System for Phosphor Dispensing Shape of LED Chip Package Using Machine Vision (머신비전에 의한 LED Chip Package 형광물질 토출형상 측정)

  • Ha, Seok-Jae;Kim, Jong-Su;Cho, Myeong-Woo;Choi, Jong-Myung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.5
    • /
    • pp.2113-2120
    • /
    • 2013
  • In this study, an efficient machine vision based inspection system is developed for the in-line measurement of phosphor resin dispensing shapes on LED chip package. Since the phosphor resin (target material) has semitransparent characteristics, illuminated light beam is reflected from the bottom of the chip as well as from the surface. Since such phenomenon can deteriorate inspection reliability, a white LED and a 635nm laser slit beams are experimentally tested to decide suitable illumination optics. Also, specular and diffuse reflection methods are tested to decide suitable optical triangulation. As a result, it can be known that the combination of a white slit beam source and specular reflection method show the best inspection results. The Catmull-Rom spline interpolation is applied to the obtained data to form smoother surface. From the results, it can be conclude that the developed system can be sucessfully applied to the in-line inspection of LED chip packaging process.

A Stability Study of Three Open-Ended Coaxial Probe Conversion Models under the Error Situations (오차에 대한 3가지 개방단말 동축선 프로브의 환산모델들간 안정성 연구)

  • 조유선;현승엽;김상욱;김세윤
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2001.11a
    • /
    • pp.300-303
    • /
    • 2001
  • 개방단말 동축선 프로브는 임의의 매질에 접촉하여 복소 유전율을 구하므로 사용이 용이한 측정법이다. 복소 유전율의 측정 과정은 두 단계로 구성된다. 먼저 프로브의 개구면을 미지의 매질에 접촉시켜서 반사계수를 측정한다. 다음에는 반사계수를 환산모델에 대입하여 복소 유전율을 구한다. 그러나 실제 측정시 발생하는 오차들에 대해 취약하다는 단점을 가지고 있다. 정확성을 떨어뜨리는 주요 오차 요인으로는 프로브의 개구면과 측정매질 사이의 공극으로 인한 불완전 접촉오타와 프로브의 제작 한계로 인한 오차를 들 수 있다. 본 논문에서는 이런 오차상황에서 유한 차분 시간영역법으로 반사계수를 계산하고나서 환산모델에 의해 복소 유전율로 환산함으로써 오차에 대한 환산모델들간의 안정성을 살펴보고자 한다.

  • PDF

Characterization of Some Mineralogical Parameters of the Au-Ag Alloys (금-은 고용체의 광물학적 특성연구)

  • 김원사
    • Journal of the Mineralogical Society of Korea
    • /
    • v.3 no.2
    • /
    • pp.98-108
    • /
    • 1990
  • 전자현미분석외에 금-은 고용체의 금 또는 은 성분을 결정할 수 있는 간편하고도 신뢰성 높은 측정법 개발은 응용 광물학자들에게 오랜 연구과제가 되어 왔다. 이를 달성하기 위한 방법으로 정량적으로 측정할 수 있는 단위포 상수, 반사도, 비중, 미경도 측정연구를 실시하였다. 이 실험을 위해 순수한 원소 금과 은을 5 at.% 간격으로 혼합하여 시료를 제작한 후 석영관을 사용하여 진공하에서 밀봉하였다. 고온에서 가열하여 용융시킨 후 서냉하여 얻어진 반응물을 각종 현미경, X 선 회절분석기, 전자현미분석기, 반사도측정기, 비중저울, 미경도측정기를 사용하여 분석하였다. 직경이 114.6 nm 인 Debye-Scherrer 카메라를 사용해 얻은 X 선분말회절자료로 계산한 단위포 상수의 크기는 은함량이 증가함에 따라 일정하게 증가한다. 반사도 측정에는 480nm와 546nm 두파장을 사용하였는데 두 파장 모두에 대해 은 함량이 증가할수록 반사도가 증가한다. 또한 480nm를 사용했을 때의 반사도 변화가 현저하므로 유용하다. 비중은 은 함량이 증가할수록 오히려 일정하게 감소한다. 한편, 25g과 50g 추를 사용하여 측정한 미경도 값은 금-은고용체내의 성분변화에 관계없이 불규칙하게 변하여 어떤 경향을 나타내지 않는다.

  • PDF

Basic Investigation for the Won-invasive Measurement of Blood Glucose Concentrations by Millimeter Waves (밀리미터파를 이용한 무혈 혈당 측정에 관한 기초 연구)

  • Kim Dong Kyun;Won Jong Hwa;Potapov Sergey N.;Meriakri Viacheslav V.;Chigryai Evgenii E.
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.42 no.1
    • /
    • pp.39-45
    • /
    • 2005
  • As a basic research for the development of a non-invasive blood glucose sensor using millimeter waves, we have presented a method for measuring the dielectric properties of high loss dielectrics, based on the reflection method, and investigated the variation of the dielectric properties of glucose-water and glucose -0.9% NaCl solutions in the 10~90 GHz range. In the proposed method, a minimal reflection condition is formed by placing a specially-chosen low-loss plane-parallel plate in front of a high-loss medium under test at a given frequency range. Using the minimal power reflection coefficient and the corresponding frequency at this condition, tile dielectric properties of the medium can be determined. The measured results on pure water have shown the adequacy of the proposed method. The measured results on glucose-water and glucose -0.9% NaCl solutions in the 10~90 GHz range showed that the variations of the dielectric properties of glucose solutions according to the change of their glucose concentration were maximum in the 30~45 GHz range. From these facts we concluded that the variation of about 3 mole/L in the glucose solutions must be distinguished With the measurement accuracies of ±0.1 dB and ±0.01 GHz.