• Title/Summary/Keyword: 반복 습윤

Search Result 47, Processing Time 0.026 seconds

Effect of Gravel Size on Shear Behavior of Sand with Dispersed Gravels (모래 지반 내에 포함된 자갈의 크기가 전단거동에 미치는 영향)

  • Park, Sung-Sik;Kim, Young-Su
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.1C
    • /
    • pp.39-51
    • /
    • 2011
  • A large number of small particles may surround large gravels which are non-contact and dispersed within the ground. The strength of such soil may be influenced by the mechanical properties of a few coarse gravels. A specimen or gravel size can impact the shear characteristics of sand with dispersed gravels. In this study, the size of gravel and specimen varies and its effect on shear characteristics of a granular soil was evaluated. Five sizes of gravels with 7, 12, 15, 18, and 22 mm were used repeatedly and inserted in the middle of each compacted layer. A specimen consists of five or ten equal layers depending on gravel size, which is 5 cm or 10 cm in diameter and 10 cm or 20 cm in height. An embedded gravel ratio by weight is 3% and constant for all cases with gravel. After consolidation, a series of undrained triaxial compression tests under three confining pressures was performed on sand with dispersed gravels. The maximum deviator stress of a specimen with 10 cm in diameter was at average 30% higher than that with 5 cm in diameter and increased up to 90% for a specimen with gravel. When a gravel size of 7 and 12 mm used, the maximum deviator stress of a specimen with 10 cm in diameter was higher than that of one without gravel, whereas the maximum deviator stress of a specimen with 5 cm was higher or lower than that without gravel. The gravel size and specimen diameter influenced the undrained behavior of sand. The maximum deviator stress of a specimen with gravel either increased or decreased compared to that without gravel, depending on the ratio of gravel size to specimen diameter, 1/5.

Assessment on the Monitoring System for KURT using Optical Fiber Sensor Cable (광섬유센서케이블을 이용한 지하처분연구시설의 감시시스템 운영 평가)

  • Kim, Kyung-Su;Bae, Dae-Seok;Koh, Yong-Kwon;Kim, Jung-Yul
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.8 no.4
    • /
    • pp.293-301
    • /
    • 2010
  • Optical fiber cable, as a sensor, was installed on the wall of KAERI(Korea Atomic Energy Research Institute) Underground Research Tunnel(KURT) in order to monitor the physical stability of the tunnel, which was constructed for technical development and demonstration of radioactive waste disposal. This monitoring system has two simultaneous measurements of temperature and strain over time using Brillouin backscatter. According to the results of the monitoring from Jan. 2008 to Nov. 2009, there is no significant displacement or movement at the tunnel wall However, the cumulative volume of total strain increased slightly as time passes with the comparison of the reference observation, which was measured in Jan. 2008. The change in cumulative volume of total strain indicates that the strain level had been affected by saturation and de-saturation phenomena due to groundwater fluctuation at several points at KURT. This system is based on the distributed sensing technique concept, not point sensing. By using this system, a displacement can be detected with the range from $20{\mu}{\varepsilon}$ to $28,000{\mu}{\varepsilon}$ every 1m interval in minimum. A temperature variation can be monitored at every 0.5m interval with the resolution of 0.01 in minimum. Based on the study, this monitoring system is potentially applicable to long term monitoring systems for radioactive waste disposal project as well as other structures and underground openings.

Development of Analytical Method for Propylene Glycol in Foods (식품 중 프로필렌글리콜의 분석법 개발)

  • Kim, Hee-Yun;Hong, Ki-Hyoung;Choi, Jang-Duck;Park, Sung-Kwan;Jung, Si-Sub;Choi, Woo-Jeong;Lee, Shin-Ho;Moon, Dong-Chul
    • Korean Journal of Food Science and Technology
    • /
    • v.37 no.6
    • /
    • pp.889-892
    • /
    • 2005
  • Standardized method based on extraction, filtration, and gas chromatography (GC) was developed far propylene glycol analysis to set hygienic norm of safety measure for foods under governmental control. Various columns were tested fur propylene glycol analysis by GC with flame ionization detector. Known amount of propylene glycol was spiked into wheat flour dough and analyzed by developed method. Results showed 101.60% recovery rate for propylene glycol with HP-5 column. Reproducibility test of standards recorded 0.30 for standard variation and 0,42% for relative variation. Using analytical method established, contents of propylene glycol in more than hundred different foods were monitored. Propylene glycol was detected in most foods, indicating propylene glycol is not only commonly added during food preparation, but also is contained naturally in food.

A Geomorphological Study on the Locational Characteristics and Construction Method of Dolmens in Hyosanri·Daesinri (지석묘의 입지특성과 축조방식에 대한 지형학적 고찰 - 효산리·대신리를 중심으로 -)

  • PARK, Cheol-Woong;KIM, In-Cheol
    • Journal of The Geomorphological Association of Korea
    • /
    • v.19 no.3
    • /
    • pp.23-36
    • /
    • 2012
  • This study aims to think about the problem of dolmens: the reasons for the presence of dolmens and how to construct it, at the point of view of geographical and geomorphological. The subjects of this study is the dolmens which locate between at Dogok Hyosanri and Chunyang Daesinri Hwasoon-gun, Jeonlanamdo. The study areas in Hyosanri, Daesinri has been observed as follows. First, the long axis direction of Dolmen upper stone and the slope one are the same. Second, tor, block stream, hockey stick, etc. Third, Composition of the soil silt> sand> clay is distributed in the order. Forth, The soil of high quality silt and the roundness of angular, sub-angular-level and the high frequency, peaks of quarts and illite clay minerals show. Fifth, in the result of $SiO_2/Al_2O_3$, $SiO_2/R_2O_3$, and CIA(Chemical Index of Alteration), Hyosanri, Daesinri areas show mechanical weathering was dominant and chemical weathering environment was not being progressed. The blocks used in construction of dolmens had moved to the bottom of slopes by mass movement such as solifluction then them which had been placed in the position seem to be used by people of Bronze. Based on the above results, the process of construction of dolmens can be estimated as follows. They would dig up the ground under the upper stone of dolmens, put the supporting stone in the place, then dig up earth, place into remains, close the obturating stones, then heal up earth.

EVA Sheet and Butyl Rubber based Waterproofing·Anti-Corrosion Sheet for Corrosion Maintenance and Repairing in the Interior Side of the Large Steel Pipes in Water Treatment Facilities (상수도용 대구경 녹 발생 강관 내부의 보수 및 성능 유지를 위한 EVA 시트와 부틸고무를 합지한 자착식 방수방식 시트의 부착성능 평가)

  • An, Ki-Won;Kim, Byoung-Il;Oh, Sang-Keun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.3
    • /
    • pp.267-274
    • /
    • 2017
  • This study discusses the applicability of environmental friendly EVA based butyl rubber self-adhesive waterproof sheet designed to prevent corrosion of large scale pipes used in the water treatment facilities during th water treatment process. The experiments conducted tested the waterproofing sheet's adhesion strength on the steel surface of the pipes and checked for whether the material has the proper response properties against the various environmental conditions. In addition, it the sheet adhered to the steel pipe was to see if the adhesion hold against the water pressure due to the ingress of inflow water. Finally, the waterproofing sheet's adhesion strength was tested on a rusted steel surface to confirm whether the material has the necessary properties to secure stable adhesion strength and prevent corrosion of steel pipes at the same time during the process of installation or maintenance. As a result, the self-adhesive waterproof sheets showed that all attachments in the untreated, long term pressuring, immersion in chemical substance (hydrochloric acid, hypochlorous acid, sodium hydroxide), low temperature ($-20^{\circ}C$) conditions showed a adhesion performance of higher than 1.5N/mm, which is the performance standard of KS F 4934. Also, in the testing to check for the adhesion property against inverse water pressure, it was observed that the adhesion failure did not occur even up to $3.0N/mm^2$ pressure. Also, in the process of assessing the adhesion performance on rusted steel surface, specimens after 12 hours of corrosion treatment was shown to have 2.1N/mm, and specimens after 168 hours of corrosion treatment was shown to have 2.0N/mm adhesion strength performance.

Analysis of Slope Stability Considering the Saturation Depth Ratio by Rainfall Infiltration in Unsaturated Soil (불포화토 내 강우침투에 따른 포화깊이비를 고려한 사면안정해석)

  • Chae, Byung-Gon;Park, Kyu-Bo;Park, Hyuck-Jin;Choi, Jung-Hae;Kim, Man-Il
    • The Journal of Engineering Geology
    • /
    • v.22 no.3
    • /
    • pp.343-351
    • /
    • 2012
  • This study proposes a modified equation to calculate the factor of safety for an infinite slope considering the saturation depth ratio as a new variable calculated from rainfall infiltration into unsaturated soil. For the proposed equation, this study introduces the concepts of the saturation depth ratio and subsurface flow depth. Analysis of the factor of safety for an infinite slope is conducted by the sequential calculation of the effective upslope contributing area, subsurface flow depth, and the saturation depth ratio based on quasi-dynamic wetness index theory. The calculation process makes it possible to understand changes in the factor of safety and the infiltration behavior of individual rainfall events. This study analyzes stability changes in an infinite slope, considering the saturation depth ratio of soil, based on the proposed equation and the results of soil column tests performed by Park et al. (2011 a). The analysis results show that changes in the factor of safety are dependent on the saturation depth ratio, which reflects the rainfall infiltration into unsaturated weathered gneiss soil. Under continuous rainfall with intensities of 20 and 50 mm/h, the time taken for the factor of safety to decrease to less than 1.3 was 2.86-5.38 hours and 1.34-2.92 hours, respectively; in the case of repeated rainfall events, the time taken was between 3.27 and 5.61 hours. The results demonstrate that it is possible to understand changes in the factor of safety for an infinite slope dependent on the saturation depth ratio.

Laboratory Tests for Trichloroethylene (TCE) and Toluene Remediation in Soil Using Soil Vapor Extraction (토양증기추출(Soil Vapor Extraction)을 이용한 토양 내 Trichloroethylene (TCE)과 Toluene정화 실험)

  • 이민희;강현민
    • Economic and Environmental Geology
    • /
    • v.35 no.3
    • /
    • pp.221-227
    • /
    • 2002
  • Column experiments were performed to evaluate the removal efficiency of soil vapor extraction (SVE) iota TCE (trichloroethylene) and toluene in soil. Homogeneous Ottawa sands and real soils collected from contaminated area were used to investigate the effect of soil properties and SVE operation conditions on the removal efficiency. In column teats with two different sizes of Ottawa sand, the maximum effluent TCE concentration in a coarse sand column was 442 mg/L and 337 mg/L in a fine sand column. However, after 20 liter gas flushing, the effluent concentrations were very similar and more than 90% of initial TCE mass were removed from the column. For two real contaminated soil columns, the maximum effluent concentration decreased 50% compared with that in the homogeneous Ottawa coarse sand column, but 99% of initial TCE mass were extracted from the column within 40 liter air flushing, suggesting that SVE is very available to remove volatile NAPLs in the contaminated soil. To investigate the effect of contaminant existing time on the removal efficiency, an Ottawa sand column was left stable for one week after TCE was injected and the gas extraction was applied into the column. Its effluent concentration trend was very similar to those for other Ottawa sand columns except that the residual TCE after the air flushing showed relatively high. Column tests with different water contents were performed and results showed high removal efficiency even in a high water content sand column. Toluene as one of BTEX compounds was used in an Ottawa sand column and a real soil column. Removal trends were similar to those in TCE contaminated columns and more than 98% of initial toluene mass were removed with SVE in both column.