• 제목/요약/키워드: 박세화

검색결과 32건 처리시간 0.026초

고급 분산 제어시스템을 위한 신경 회로망 제어 알고리즘의 개발 (Development of neural network algorithm for an advanced distributed control system)

  • 이승준;박세화;박동조;김병국;변증남
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1993년도 한국자동제어학술회의논문집(국내학술편); Seoul National University, Seoul; 20-22 Oct. 1993
    • /
    • pp.953-958
    • /
    • 1993
  • We develop a neural network control algorithm for the ACS (Advanced Control System). The ACS is an extended version of the DCS (Distributed Control System) to which functions of fault detection and diagnosis and advanced control algorithms are added such as neural networks, fuzzy logics, and so on. In spite of its usefulness proven by computer simulations, the neural network control algorithm, as far as we know, has no tool which makes it applicable to process control. It is necessary that the neural network controller should be turned into the function code for its application to the ACS. So we develop a general method to implement the neural network control systems for the ACS. By simulations using the simulator for the boiler of 'Seoul fire power plant unit 4', the methodology proposed in this paper is validated to have the applicability to process control.

  • PDF

실시간 운영체제 환경하에서 이중화된 제어시스템을 위한 소프트웨어의 구현 (Implementation of a software for a control system with dual structure under the real-time operating system)

  • 박세화;황동환;이재혁;김병국;변증남;문봉채;김은기
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1992년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 19-21 Oct. 1992
    • /
    • pp.61-66
    • /
    • 1992
  • In this paper, a method for implementing software for the control system with dual structure in processor module is proposed and implemented to enhance its reliability. In this implementation the multi-tasking function which is provided by a real-time operating system is applied. The overall softwre is divided into five tasks and is performed in each of the dual processor module, independently. By this, the processor module with dual structure can achieve a control objective and fault diagnostics effectively. An experimental result shows that the backup processor module can be substituted for the primary processor module immediately when it happens to fail, because data relating the failure information are exchanged continuously done via shared memories.

  • PDF

화력발전소 경보처리 시스템에 관한 연구 (A Study on the Alarm Processing System for Fossil Power Plant)

  • 신승철;박세화;이재혁
    • 전자공학회논문지B
    • /
    • 제32B권8호
    • /
    • pp.1045-1056
    • /
    • 1995
  • The purpose of multiple alarm processing is to give the operator the correct information and perception of the malfunction present in the plant. In this thesis, an APS(Alarm Processing System) is studied for fossil power plants. This APS is based on a cause-consequence trees in the knowledge representation aspect for alarm and plant and adapts alarm filtering methods using fired time information in the decision aspect. Through the cause-consequence trees and filtering methods, the Alarm Processing System finds the cause alarm among the fired multiple alarms and calculates the cause degree which represents the possibility of a fault occurring in the instruments of the plant with the information of fired alarm. The knowledge base is built via interviews and questionaries with the expert operators on the Seoul power plant unit 4. Finally, the validity of the studied APS is shown via simulations.

  • PDF

화력 발전소 드럼형 보일러 시스템의 고장 진단을 위한 퍼지 전문가 시스템의 개발 (Development of Fuzzy Expert System for Fault Diagnosis in a Drum-type Boiler System of Fossil Power Plant)

  • 변승현;박세화
    • 전자공학회논문지B
    • /
    • 제31B권10호
    • /
    • pp.53-66
    • /
    • 1994
  • In this paper, a fuzzy expert system is developed for fault diagnoisis of a drum-type boiler system in fossil power plants. The develped fuzzy espert system is composed of knowledge base, fuzzification module, knowledge base process module, knowledge base management module, inference module, and linguistic approximation module. The main objective of the fuzzy expert system is to check the states of the system including the drum level and detect faults such as the feedwater flow sensor fault, feedwater flow control valve fault, and water wall bube rupture. The fuzzy expert system diagnoses faults using process values, manipulated values, and knowledge base which is built via interviews and questionaries with the experts on the plant operations. Finally, the validity of the developed fuzzy expert system is shown via experiments using the digital simulator for boiler system is Seoul Power Plant Unit 4.

  • PDF

제철소 연속주조 공정에서의 퍼지제어를 위한 기능코드의 구현 연구 (A Study on Realization of Function Code for Fuzzy Control in the Continuous Casting Process of the Iron & Steel Works)

  • 허영기;박세화;이재혁
    • 전자공학회논문지B
    • /
    • 제32B권12호
    • /
    • pp.1545-1551
    • /
    • 1995
  • As the modern industrial processes become more complex, it is getting more difficult to model and control the processes. Naturally, an advanced type of DCS(Distributed Control System) with higher level functions is being sought. Advanced DCS is a DCS with advanced functions such as fault diagnosis, GPC(Generalized Predictive Control), NN(Neural Network), and Fuzzy Control. In this thesis, we have studied a fuzzy control algorithm for realizing an advanced DCS. Its algorithm is implemented in a form of function code which is a process control language, being used by the industrial engineers. To verify the realized function code of the fuzzy control, the function code is applied to a continuous casting process of the Pohang Iron & Steel Works in Kwangyang. The rules of the fuzzy control were collected via interviews of the field operators and their operation documents. Finally under a real-time operating system environment, usability of the function code of the fuzzy control is shown via simulation for the continuous casting process.

  • PDF

초점면 배열 방식의 열상카메라 시스템의 구현 (Implementation of a Thermal Imaging System with Focal Plane Array Typed Sensor)

  • 박세화;원동혁;오세중;윤대섭
    • 제어로봇시스템학회논문지
    • /
    • 제6권5호
    • /
    • pp.396-403
    • /
    • 2000
  • A thermal imaging system is implemented for the measurement and the analysis of the thermal distribution of the target objects. The main part of the system is a thermal camera in which a focal plane array typed sensor is introduced. The sensor detects the mid-range infrared spectrum of target objects and then it outputs a generic video signal which should be processed to form a frame thermal image. Here, a digital signal processor(DSP) is applied for the high speed processing of the sensor signals. The DSP controls analog-to-digital converter, performs correction algorithms and outputs the frame thermal data to frame buffers. With the frame buffers can be generated a NTSC signal and transferred the frame data to personal computer(PC) for the analysis and a monitoring of the thermal scenes. By performing the signal processing functions in the DSP the overall system achieves a simple configuration. Several experimental results indicate the performance of the overall system.

  • PDF

생체 임피던스 계측 방법의 구현에 관한 연구 (A Study on an Implementation of Bioelectric Impedance Instrumentation)

  • 김홍석;박세화
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.247-247
    • /
    • 2000
  • A new bioelectric impedance measurement method is proposed for the precise measurement of the bioelectric impedance. To obtain the impedance from the known applied a.c. current and the measured voltage signals, a frequency conversion circuit, like the mixer in heterodyne receivers, is introduced to reduce the frequency of the original current. It can be observed from several lines of derivation that the impedance is independent on the amplitude and phase of the mixing signals. This makes it possible to use low-speed analog-to-digital converters and thus utilize cheaper electronic parts in the implementation. The possibility of the method is shown by simulations, and a generic structure applicable to bioelectric impedance measurement devices is also proposed.

  • PDF

이중구조를 갖는 제어시스템의 구현과 신뢰도 분석에 관한 연구 (A Study on the Implementation of a Control System with Dual Structure and Its Reliability Analysis)

  • 박세화;문봉채;김병국
    • 대한전자공학회논문지
    • /
    • 제27권9호
    • /
    • pp.1351-1363
    • /
    • 1990
  • In this paper, a reliable control system structured with dual CPU modules and dual I/O modules is implemented as a means of achieving a highly reliable fault tolerant control system. For this, faults in the system modules are first examined, and a fault detection technique consisting of self diagnostic, comparison process, and exception processing is applied. Self diagnostic is used to locate which components in the modules have been failed, while comparison process is to cmpare control outputs computed by both CPU modules and protect the plant from malfunction by blocking failed control outputsin advance. Finally exception processing is used to determine the faults that are not detected immediately by the self diagnostic and comparison process, e.g. bus error processing when acknowledge signal for data transfer is not activeted in the I/O modules. Also reliability analysis is conducted for the discrete time Markov model with dual structure. It is shown quantitatively that the reliability is improved in the control system with dual structure in comparison with a system with single module structure.

  • PDF

냉각조건변화에 따른 폴리에틸렌의 트리잉 파괴 예지에 관한 연구 (A Study on the Treeing Breakdown Expectation due to Variation of Quenching in Polyethylene)

  • 박세화;심종탁;김성홍;백관현;박재준;김재환;박창옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1580-1582
    • /
    • 1994
  • In this study, when AC voltage is applied to block type treeing specimen which is fabricated with polyethylene which dielectric characteristics is excellent, from initial tree to final breakdown, Using acoustic emission method. we take statistically on parameter, which is skewness. We experimented on quenching condition and illustrated skewness locus plane so that studied interrelation of life expectation and parameter.

  • PDF

불확정성 선형시스템에 대한 $H_{\inf}$ 노옴 성능 경계를 만족하는 신뢰성 제어시스템의 설계 (Design of Reliable Control System Guaranteeing $H_{\inf}-norm$ Peformance Bound for Uncertain Linear System)

  • 박세화
    • 전자공학회논문지B
    • /
    • 제33B권8호
    • /
    • pp.1-14
    • /
    • 1996
  • Design of a reliable control systems is investigated for a class of uncertain linear plants. The uncertainty considered here is for the ase of uncertainty in the system matrix. A decentralized control scheme with two observer-based feedback controllers is developed, and it is shown that the resulting closed-loop system is reliable in the sense that the control scheme provides guaranteed stability and $H_{\infty}$-norm bounded performance in the event of sensor and/or actuator failures as well as in the presence of parameter uncertainties. We observed that soft-type failures were additional exogenous inputs to the closed-loop system. As a results, the sensor and/or actuator failures can be tolerated in the design, which is achieved by extending the methodology developed in.

  • PDF