• Title/Summary/Keyword: 박리성 대동맥류

Search Result 28, Processing Time 0.018 seconds

Composite Graft Aortic Root Replacement with Coronary Button Reimplantation: The Early and Mid-Term Results (Composite graft를 이용한 대동맥근부 치환술: Button 술식의 중단기 결과)

  • 나찬영;백만종;김웅한;오삼세;김수철
    • Journal of Chest Surgery
    • /
    • v.35 no.5
    • /
    • pp.356-364
    • /
    • 2002
  • Background: This study was undertaken to investigate the outcome of composite graft aortic root replacement using coronary button reimplantation technique for the treatment of aneurysms of the ascending aorta involving the aortic root. Material and Method: Between April 1995 and September 2001, 54 patients having aortic root replacement with a composite valve graft using direct coronary button reimplantation were reviewed retrospectively. Left ventricular dysfunction was present in 14 patients(25.9%), aortic regurgitation in 48(89%), and Marfan's syndrome in 17(31.5%). The indications for operation were annuloaortic ectasia in 29 patients(53.7%), aortic dissection in 11(20.4%), aneurysms of the ascending aorta involving aortic root in 12(22.2%), and aortitis in 2(3.7%). Six patients(11.1%) had previous cardiac or ascending aortic operations. Concomitant procedures were arch replacement in 21 patients(38.9%), coronary artery bypass graft in 7(13%), mitral valve repair or replacement in 4(7.4%), and others in 6. The mean time of circulatory arrest, total bypass, and aortic crossclamp were 18 $\pm$ 9 minutes, 177 $\pm$ 42 minutes, and 127 $\pm$ 31 minutes, respectively. Result: There was 1 early death(1.9%). Mean follow-up was 24.6$\pm$ 19.5 months. There were two late deaths(3.8%) including one death due to the traumatic cerebral hemorrhage. The Kaplan-Meier survival rate was 98.0 $\pm$ 2.0% and 93.1 $\pm$ 5.1% at 1 and 6 years, respectively. Two patients required reoperation owing to a false aneurysm at the root anastomosis site and a malfunction of prosthetic aortic valve(3.8%). Staged operation for dissection of the remaining thoracoabdominal aorta was performed in 1 patient. The freedom rate from reoperation was 97.8 $\pm$ 2.0% and 65.3 $\pm$ 26.7% at 1 and 6 years, respectively.

Percutaneous Endovascular Stent-graft Treatment for Aortic Disease in High Risk Patients: The Early and Mid-term Results (고위험군의 대동맥류 환자에서 경피적으로 삽입이 가능한 스텐트 그라프트를 이용한 치료: 조기 및 중기성적)

  • Choi, Jin-Ho;Lim, Cheong;Park, Kay-Hyun;Chung, Eui-Suk;Kang, Sung-Gwon;Yoon, Chang-Jin
    • Journal of Chest Surgery
    • /
    • v.41 no.2
    • /
    • pp.239-246
    • /
    • 2008
  • Background: Aortic surgery for high risk patients has high mortality and morbidity rates, and the necessity of performing aortic surgery in cancer patients is questionable because of their short life expectancy. Endovascular repair of aneurysm repair can be considered for high risk patients and cancer patients because it has relatively lower invasiveness and shorter recovery times than aortic surgery does. Especially, percutaneous endovascular stent graft treatment is more useful for high risk patients because it does not require general anesthesia. Material and Method: From July 2003 to September 2007, twelve patients who had inoperable malignancy or who had a high risk of complication because of their combined diseases during aortic surgery underwent endovascular aortic aneurysm repair. he indications for endovascular repair were abdominal aortic aneurysm in 5 patients, descending thoracic aortic aneurysm in 6 patients and acute type B aortic dissection in one patient. The underlying combined disease of these patients were malignancy in 3 patients, respiratory disease in 6 patients, old age with neurologic disease in 6 patients, Behcet's iseae in one patient and chronic renal failure in one patient. Result: Stent grafts were inserted percutaneously in all cases. There were 4 hospital deaths and there were 3 delayed deaths during the follow-up periods. There were no deaths from aortic disease, except one hospital death. There were several complications: a mild cerebrovascular accident occurred in one patient, acute renal failure occurred in 2 patients and ischemic bowel necrosis occurred in one patient. Mild type I endoleak was observed in 2 patients and type II endoleak was observed in a patient after stent graft implantation. Newly developed type I endoleak was observed in a patient during the follow-up period. Conclusion: Percutaneous endovascular stent graft insertion is relatively safe procedure for high risk patients and cancer patients. Yet it seems that its indications and its long term results need to be further researched.

Endovascular Aortic Balloon Clamping for Various Heart Disease (대동맥 내 풍선 차단법을 이용한 여러 가지 심장수술)

  • Choi, Jin-Ho;Park, Pyo-Won
    • Journal of Chest Surgery
    • /
    • v.41 no.1
    • /
    • pp.61-67
    • /
    • 2008
  • Background: Conventional ascending aortic cross clamping is often limited. This study was carried out to evaluate the safety and efficacy of an endovascular aortic clamping technique with an intraaortic balloon catheter. Material and Method: From April 2004 to January 2007, surgery with endoaortic clamping was performed in seven patients. A retrograde access perfusion (RAP) catheter was used in six patients and a Pruitt's balloon catheter in two patients. The indication for the operation was a retrosternal pseudoaneurysm of the aortic root in six patients, diffuse calcification of the ascending aorta with aortic regurgitation in 2 patients and an atrial septal defect in one patient. Five patients had at least two prior cardiac surgeries. Result: Successful insertion of the catheter and endoaortic clamping was achieved in all patients. Conclusion: The endovascular aortic clamping technique with a balloon catheter was a useful alternative method for patients in whom conventional cardiac surgery was limited.

Comparision of Inclusion TechnicRue with Open Technique in Patients with Bentall Procedures (Bentall수술에서 inclusion technique 과 open technique의 비교)

  • 김정택;문준호
    • Journal of Chest Surgery
    • /
    • v.30 no.5
    • /
    • pp.506-511
    • /
    • 1997
  • To understand the clinical results of aortic root replacement with either inclusion or open technique, we analysed 53 patients who underwent replacement of the aortic root with composite graft between October,1980, and May, 1995. Annuloaortic ectasia was the most common indication for operation(29 patients), follwed by aortic dissection(22 patients). Among 53 patients, 19(35%) had Marfan syndrome. Three patients died during hospitalization (Mortality: 5.5%). The follow up was possible in 48 patients(Follow-up rate; 94%,mean duration;37 months). The actuarial survival rate at 24 months was 95% in open technique group, and 87% in inclusion technique group. Late complications developed in 10 patients. Dissecting aneurysm in the remaining aorta was noted in 3 patients with inclu ion 1,schnique, and a pseudoaneurysm from coronary artery anastomosis site developed in a patient with inclusion technique. In conclusion, there was no statistical differences in survival for 24 months between inclusion technique and open technique group. But late problems in the remaining aorta or death from unknown cause occurred with moderate frequency : careful follow-up after aortic root replacement thought to be important for long term survival.

  • PDF

Surgical Treatment for Dissecting Aneurysm of the Aorta using Sutureless Intraluminal graft (무봉합 혈관내 인조이식혈관을 이용한 박리성 대동맥류의 수술요법)

  • 이재원
    • Journal of Chest Surgery
    • /
    • v.18 no.2
    • /
    • pp.305-313
    • /
    • 1985
  • Surgical therapy for dissection of the aorta has had a high mortality. One contributing factor has been hemorrhage from the prosthesis and the suture lines. Recently, a new method of treatment with an intraluminal graft that requires no end-to-end anastomosis has been developed. Of the four patients with dissecting aneurysm of the aorta treated by inserting sutureless ringed intraluminal graft at the Department of Thoracic and Cardiovascular Surgery, S.N.U.H., three were DeBakey type I [one with associated aortic insufficiency] and the other was DeBakey type III. Suspected etiology of the dissection was Marfan`s syndrome in one and hypertension in the others. Total cardiopulmonary bypass was utilized in repairing dissecting aneurysms of the ascending aorta [type A] and simple aortic crossclamping was used for the patient with dissecting aneurysm of the descending aorta. The basic technique consists of inserting the whole ringed graft into the true lumen of the dissected aorta and circumferentially ligating the aorta against the groove in the rings. The proximal ring of the graft effectively stabilized the flail aortic valve in patient with aortic insufficiency associated with dissection of the ascending aorta. There were no hospital deaths and one patient with type III dissecting aneurysm developed postoperative paraparesis and renal insufficiency which was resolved. Follow-up has been from 1 month to 16 months with no evidence of prosthetic problems, such as erosion, migration, or thrombosis.

  • PDF

Chronic Dissecting Aortic Aneurysm with Right Coronary Artery Perfused Solely by False Lumen of Asceading Aorta (가성 내강에서 우측 관상동맥으로 혈류가 공급되는 원인 미상의 만성 박리성 대동맥류 1례 보고)

  • Go, Myeong-Gu;Kim, Jong-Myung;Lee, Kwan-Ho;Kim, Young-Jo;Shim, Bong-Sup;Lee, Hyun-Woo;Hwang, Mee-Soo
    • Journal of Yeungnam Medical Science
    • /
    • v.5 no.1
    • /
    • pp.159-166
    • /
    • 1988
  • Dissecting aortic aneurysm is relatively rare in those under 40 years of age without high risk factors. After dessecting aortic aneurysm is occured, the coronary artery is rarely perfused by false lumen. We present a thirty two-year-old man who showed Debakey type 1 dissecting aortic aneurysm with right coronary artery perfused by false lumen of ascending aorta and with congestive heart failure due to aortic insufficiency without discernible risk factor. Medical and surgical treament(Modified Bentall's operation) were successfully performed. The pathologic report showed combined cystic medial necrosis. Now he is well tolerated and stable only with anticoagulation during follow up 18 months.

  • PDF

Operation of Ascending Aorta and/or Aortic Arch (상행대동맥 및 대동맥궁의 수술)

  • 구본원;허동명;전상훈;장봉현;이종태;김규태;이응배
    • Journal of Chest Surgery
    • /
    • v.29 no.11
    • /
    • pp.1212-1217
    • /
    • 1996
  • From Dec. 1993 to May 1995, 9 male and 5 female patients ranging in age from 25 to 65 years, were operated on for ascending aorta and/or aortic arch diseases. Six patients had acute aortic dissection, type A(ruptured in 4 cases); four had ruptured ascending aortic aneurysm; three had annuloaortic ectasia(ruptured in 1 cases); one had aortic arch aneurysm. The diagnostic procedures were echo cardiography and dynamic CT scan in all patients having acute dissection or rupture. The aortic angiography was performed in two cases. Indications for operations were rupture in five cases, acute aortic dissection in five cases, severe congestive heart failure in two cases, progressive aortic insufficiency in one case and impending rupture in one case. The emergent repair was performed in ten cases(71%). The surgical treatment consisted of 6 Cabrol operations, a Cabrol operation combined with arch replacement, a modified Bentall operation, 4 replacement of ascending aorta, a replacement of aortic arch, and a replacement of ascending aorta and aortic arch. Complications were a hypoxic encephalopathy, two atrial fibrillations, a sternal deheiscence, and a mediastinitis. Two early mortality(14%) were due to intractable bleeding and multiple organ failure, and one late mortality(7%) was due to ventricular arrhythmia. In eleven survivors, follow-up period was from 2 months to 12 months and the course was uneventful.

  • PDF

Composite valve graft Replacement of the Aortic Root (Composite valve graft를 이용한 대동맥근부 치환술)

  • 백만종;나찬영;김웅한;오삼세;김수철
    • Journal of Chest Surgery
    • /
    • v.35 no.2
    • /
    • pp.102-112
    • /
    • 2002
  • This study was undertaken to analyze the outcome of composite valve graftreplacement(CVGR) for the treatment of aneurysms of the ascending aorta involving the aortic root. Material and Method: Between April 1995 and June 2001, 56 patients had replacement of the ascending aorta and aortic root with a composite graft valve and were reviewed retrospectively. Aortic regurgitation was present in 50 patients(89%), Marfan's syndrome in 18 patients(32%), and bicuspid aortic valve in 7(12.5%). The indications for operation were annuloaortic ectasia(AAE) in 30 patients(53.6%), aortic dissection in 13(23.2%), aneurysms of the ascending aorta involving aortic root in 11(19.6%), and aortitis in 2(3.6%). Cardiogenic shock due to the aortic rupture was present in 2 patients. Nine patients(16%) had previous operations on the ascending aorta or open heart surgery. The operative techniques used for CVGR were the aortic button technique in 51 patients(91%), the modified Cabrol technique in 4, and the classic Bentall technique in 1. The concomitant procedures were aortic arch replacement in 24 patients(43%), coronary artery bypass graft in 8(14.3%), mitral valve repair in 2, redo mitral valve replacement in 1, and the others in 7 The mean time of circulatory arrest, total bypass, and aortic crossclamp were 21$\pm$14 minutes, 186$\pm$68 minutes, and 132$\pm$42 minutes, respectively. Result: Early mortality was 1.8%(1/56). The postoperative complications were left ventricular dysfunction in 16 patients(28.6%), reoperation for bleeding in 7(12.5%), pericardial effusion in 2, and the others in 7. Fifty-three patients out of 55 hospital survivors were followed up for a mean of 23.2 $\pm$ 18.7 months(1-75 months). There were two late deaths(3.8%) including one death due to the traumatic cerebral hemorrhage, and CVGR-related late mortality was 1.9%. The 1- and 6-year actuarial survival was 98.1$\pm$1.9% and 93.2$\pm$5.1%, respectively. Two patients required reoperation for complication of CYGR(3.8%) and two other patients required subsequent operations for dissection of the remaining thoracoabdominal aorta. The 1- and 6-year actuarial freedom from reoperation was 97.8$\pm$2.0% and 65.3$\pm$26.7%, respectively.

The Thracoabdominal Aortic Replacement Using Deep Hypothermic Circulatory Arrest Technique (흉복부대동맥치환술에서 극저체온하순환정지법의 효과)

  • Woo, Jong-Su;Bang, Jung-Hee;Kim, Si-Ho;Choi, Pil-Jo;Cho, Kwang-Jo
    • Journal of Chest Surgery
    • /
    • v.39 no.3 s.260
    • /
    • pp.194-200
    • /
    • 2006
  • Background: Thoracoabdominal aortic replacement is an extensive operation that opens both the pleural cavity and abdominal cavity, which has high mortality and morbidity rate. The authors have reported 9 cases of the thoracoabdominal aortic replacement in 2001. Since 2003 we have applied the deep hypothermic circulatory arrest to the Crawford type I and II thoracoabdominal aortic replacement. Therefore, we analysed the effect of the changes in operative techniques. Material and Method: Between 1996 and 2005, we have performed 20 cases of thoracoabdominal aortic replacement. The underlying diseases were 8 cases of atherosclerotic aneurysm with 4 cases of ruptured aneurysm and 12 cases of aortic dissection with 10 cases of a previous operations. According to Crawford classification, there were 2 cases of type I, 7 cases of type II, 1 case of type III, 7 cases of type IV, and 3 cases of type V. We compaired the results of the patients who underwent thoracoabdmoninal replacement before 2001 which already has been reported and after then. Result: Before 2001 we have performed 9 cases of thoracoabdominal replacement and 5 patients were died of the operation. All three patients with type I and II were died. There was no case of thoracoabdominal replacement between 2001 and 2002, but after 2003 we have performed 11 cases of thoracoabdominal replacement which involved 1 case of type I, 5 cases of type II, 1 case of type III, 2 cases of type IV and 2 cases of type V. There was no mortality and no fetal complications. Conclusion: The deep hypothermic circulatory arrest is a safe method of extended thoracoabdominal aortic replacement.

Use of Intraluminal Sutureless Graft in the Surgical Treatment of Dissecting Aneurysm(Debakey type III) of the Thoracic Aorta (무봉합 혈관내 인조혈관을 사용한 박리성 하행흉부대동맥류의 치료 -2례 보고-)

  • 홍순필
    • Journal of Chest Surgery
    • /
    • v.27 no.10
    • /
    • pp.862-867
    • /
    • 1994
  • We experienced two cases of dissecting aneurysm[DeBakey type III] of the thoracic aorta treated using intraluminal sutureless graft. Controversy still exists about the exact timing of surgical intervention for dissection of the descending thoracic aorta. The surgical indication of dissecting aneurysm[DeBakey type III] is continuous flow in the false lumen, continuous chest pain, compromise of arterial supply to a specific organ or limb, or extension of the dissection while the patient is receiving satisfactory medical treatment. Surgical therapy for dissection of the aorta has had a high mortality. One contributing factor has been hemorrhage from the prosthesis and the suture lines. Recently, a new method of treatment with a intraluminal sutureless graft that requires no end-to-end anastomosis has been developed. In our cases, cardiopulmonary bypass and circulatory arrest was utilized in repairing dissecting aneurysm of descending aorta[DeBakey type III] in order to avoid the aortic cross clamping because of friable aortic intima. The basic technique consists of vertical incision of descending aorta in the area of intimal tear and inserting the whole ringed graft into the true lumen of the dissected aorta and circumferentially ligating the aorta against the groove in the rings. Postoperative course was uneventful.

  • PDF