• Title/Summary/Keyword: 바닥구조

Search Result 948, Processing Time 0.029 seconds

Temperature-Induced Stresses and Deformation in Composite Box Girder Bridges (합성 박스형 교량의 온도에 의한 응력 및 변형)

  • Chang, Sung Pil;Im, Chang Kyun
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.4 s.33
    • /
    • pp.659-672
    • /
    • 1997
  • Thermal response induced from nonlinear temperature distribution in composite box gilder bridges depends on several variables(environmental conditions, physical and material properties, location and orientation of bridge, and cross-section geometry). In this paper, parametric study are conducted in order to find the effects of variations of seasons, location and orientation of bridge, sectional geometry and some material properties on the axial deformation, curvature and stresses in composite box girder bridge. A two-dimensional transient finite element model to conduct this parametric studies is briefly presented. Firstly, the effects of the parameters on the diurnal variation of curvature are considered, and for the time of maximum curvature, on the distribution of temperature and stresses of composite box girder sectional are considered. Finally, some considerations about the influence of the parameters on the daily maximum values of axial deformation, curvature and stresses are carried out. The influence of thermal effect on structures is important as much as the influence of live or dead load in some cases. In the design of steel composite bridges, the thermal stresses calculated on the supposition that the temperature difference between the concrete slab and steel girder is $10^{\circ}C$ and the temperature distributions are uniform in concrete slab and steel girder can be underestimated.

  • PDF

A Numerical Study on Load Distribution Factors for Simplified Composite H-Beam Panel Bridges (강합성 초간편 H형강 교량의 하중분배계수에 관한 해석적 연구)

  • Park, Jong Sup;Kim, Jae Heung
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.3
    • /
    • pp.221-232
    • /
    • 2009
  • The load distribution factor (LDF) values of simplified composite H beam panel bridges (SCHPBs) that were subjected to one lane and two lane loads were investigated using three dimensional finite element analyses with the computer program ABAQUS (2007). This study considered some design parameters such as the slab thickness, the steel plate thickness, the span length, and the continuity of the SCHPBs in the development of new LDFs. The distribution values that were obtained from these analyses were compared with those from the AASHTO Standard, LRFD, and the equations presented by Tarhini and Frederick, Huo et al., Back and Shin, and Cai. The AASHTO Standard distribution factors for SCHPBs were found to be very conservative. Sometimes, the distribution values from the finite element analyses for interior girders were similar to the results of the AASHTO LRFD, whereas the values for exterior girders were conservative in most cases. The new distribution values that were presented in this study produced LDFs that are more conservative than those from the finite element method. For the simple application of the design to SCHPBs, bridge engineers can use 0.42 for the interior girder and 0.32 for the exterior girder. The proposed values improve the current design procedure for the LDF problem and increase SCHPB design efficiency.

A Study on the Application Scheme of Fire Identification Considering the Heat Release Rate Characteristics of Inflammable Material (가연물의 발열량 특성을 고려한 화재감식 적용방안에 관한 연구)

  • Kang, Jung-Ki;Oh, Jin-Hee;You, Woo-Jun;Ryou, Hong-Sun;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.28 no.6
    • /
    • pp.52-57
    • /
    • 2014
  • The present study suggests the fundamental method for the prediction time of the fire origin by analyzing the combustion phenomenon of inflammable material in the building structure. The heat release rate (HRR) with time variant is evaluated for the interphone as a inflammable material, which is opted from the fire incidents in the stairwell. the fire dynamics simulator (FDS ver. 6.1) is applied in order to analyze the difference of the smoke inflow time to the downstair from the fire event area with various fire pattern. The results show that the maximum inflow time difference for the case of the interphone made from ABS materials is about 4.93 times with the input conditions of heat flux values and the environment in the FDS for the fixed stairwell which composed of total volume $291.3m^3$, floorage $23.3m^2$ and the height of each floor 2.5 m. This research can be practical information for the application method of simulation scheme with experimental data to the fire Identification.

Ultrastructural Changes of the Bruch's Membrane and the Pigment Epithelial Cells of the Mouse Retina with Age (노화에 따른 마우스 망막의 바닥복합층과 색소상피세포의 미세구조 변화)

  • Ko, Jeong-Sik;Park, Byung-Lok;Ahn, E-Tay;Park, Kyung-Ho;Kim, Jin-Gook
    • Applied Microscopy
    • /
    • v.27 no.4
    • /
    • pp.357-372
    • /
    • 1997
  • To study the age-related morphological differences of the retinal pigment cells and Bruch's membrane of mouse, retinae of one week-old, five weeks-old, eight weeks-old, six months-old, twelve months-old, eighteen months-old, twenty-four months-old and thirty months-old ICR mice were dissected out under anesthesia. Pieces of the tissue taken from the posterior region of the retina were fixed in 2.5% glutaraldehyde-1.5% paraformaldehyde (0.1 M Millonig's phosphate buffer, pH 7.3), and 1% osmium tetroxide (0.1 M Millonig's phosphate buffer, pH 7.3), and embedded in araldite mixture. The ultrathin sections were stained with uranyl acetate and lead citrate, and were observed under a JEM 100 CX-II electron microscope. Observed results were as follows: 1. Retinae of one week old mouse exhibit that some parts of the pigment cell provided with basal foldings, whereas other parts of the one contain without basal foldings. After (ive weeks-old, all retinal pigment cells have the basal infoldings. 2. In the one week-old, stage 1 and stage 2 melanosomes were observed in the retinal pigments cells, but after five weeks-old, most of the retinal pigment cells contain some matured stage melanosomes (stage III and stage IV). 3. The phagosomes in the retinal pigment cells were increased during aging. 4. After eighteen months-old, electron dense materials are observed within the basal infoldings. 5. After eighteen months-old, the thickness of the Bruch's membrane is prominently increased. The thickness of the basal laminae of the pigment cell and the choriocapillary endothelium is more prominently increased as compared with that of the other components of the Bruch's membrane. 6. The thickness of the basal lamina of the pigment cell is more prominently increased as compared with that of the choriocapillary endothelium on aging. From the above results, it was suggested that the pigment cell and Bruch's membrane matures structurally In five weeks, and the function of the pigment cell is prominently suppressed around eighteen months-old, and thereafter the functional suppression is continued on aging.

  • PDF

The Effects of Confined Rates Side Wall of Pen for Evacuation Behaviors of Pigs (돈방 측벽마감율이 돼지의 배분 특성에 미치는 영향)

  • 송준익;최홍림
    • Journal of Animal Environmental Science
    • /
    • v.7 no.3
    • /
    • pp.147-154
    • /
    • 2001
  • An experiment was conducted to examine environmental influences upon the behavioral pattern of pigs. The resting areas of an enclosed growing-finishing pig house were checked in two seasonal ventilation systems, and the excretion habit of pigs influenced by the different closing rates (50, 75 and 100%) of side walls of pens was surveyed. 1. The excretion habit of pigs was not influenced by temperature, humidity and the flow speed of running air as they excreted in a fixed area of the side walls. However, the lighting effects on the excretion habit was observed because pigs excreted in the darkest area of the pig pen. 2. The accumulated height and width of feces showed 10 and 30 cm; 5 and 25cm; and 3 and 20cm for 50, 75 and 100% of closing rates of side walls, respectively. It indicates that pigs excrete all over the floor in the pen with 100% closed side walls. 3. Ammonia concentrations of the resting areas on the pen floor were determined to 4.2, 5.1 and $5.8mg/{\ell}$ for 50, 75 and 100% of closing rates of side walls, respectively. It indicates that the ammonia concentration was highest in the pen with 100% closed side walls. Thus, the high ammonia concentration of the resting areas could be reduced by illuminating the darker areas with relation to the excretion habit. 4. The flow speed of running air was likely the biggest factor influencing the resting areas of pigs; pigs took a rest at the place of 0.04 m/s air flow speed point during midwinter, and at the place of 0.24 m/s air flow speed point during midsummer.

  • PDF

Case Study on Optimization of Send-out Operation in Liquefied Natural Gas Receiving Terminal (LNG 터미널 송출 운전 최적화 사례 연구)

  • Park, Chansaem;Han, Chonghun
    • Korean Chemical Engineering Research
    • /
    • v.53 no.2
    • /
    • pp.150-155
    • /
    • 2015
  • Recently, LNG receiving terminals have been widely constructed and expanded for an increase in LNG demand. Selection of the storage tank for send-out and estimation of send-out flow rate have significant influence to process operation and economics. In this study, a send-out flow rate of each storage tank is optimized in order to minimize the total BOG generation rate. Considering a size and characteristic of each storage tanks, BOG flow rates are estimated using a dynamic simulation with varying liquid levels in the tanks. The regression model is developed fitting BOG flow rates and tank liquid levels, which are boil off rate model to predict BOG flow rates with particular level data. The objective function and constraints including required total send-out flow rate and level limit in the tanks are formulated to optimize a send-out flow rate of each tank. This method for optimization of send-out operation is applied to the Incheon LNG receiving terminal considering two scenarios for various liquid levels and maximum and minimum required send-out flow rates. For maximum required send-out flow rate, this method achieves BOG reduction of 9% comparing with assumed conventional operation.

Analysis of C-V Characteristics of MIS Structure Based on OTFT Technology for Flexible AM-OLED (Flexible AM-OLED를 위한 OTFT 기술 기반의 MIS 구조 C-V 특성 분석)

  • Kim, Jung-Seok;Kim, Byoung-Min;Chang, Jong-Hyeon;Ju, Byeong-Kwon;Pak, Jung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2006.10a
    • /
    • pp.77-78
    • /
    • 2006
  • 최근 flexible OLED의 구동에 사용하기 위한 유기박막트랜지스터(Organic Thin Film Transistor, OTFT)의 연구에서는 용매에 용해되어 spin coating이 가능한 재료의 개발에 관심을 두고 있다. 현재 pentacene으로는 아직 spin coating으로 제작할 수 있는 상용화된 제품이 없고 spin coating이 가능한 활성층 물질(active material)로 P3HT가 쓰이고 있다. 본 연구에서는 용해 가능한 P3HT 활성층 물질과 여러 종류의 용해 가능한 게이트 절연물(gate insulator, Gl)을 사용하여 안정된 소자를 구현할 수 있는 공정을 개발하는 목적으로 metal-insulator-semironductor(MIS) 소자를 제작하여 C-V 특성을 측정하고 분석하였다. 먼저 7mm${\times}$7mm 크기의 pyrex glass 시편 위에 바닥 전극으로 $1600{\AA}$ Au을 증착하고 spin coating 방식을 이용하여 PVP, PVA, PVK, BCB, Pl의 5종류의 게이트 절연층을 각각 형성하였고 그 위에 같은 방법으로 P3HT를 코팅하였다. P3HT 코팅 시 bake 공정의 유무와 spin rpm의 변화에 따른 P3HT의 두께를 측정하였다. Gl의 종류별로 주파수에 따른 capatltancc를 측정하여 비교, 분석하였다. C-V 측정 결과 PVP, PVA, PVK, BCB, Pl의 단위 면적당 capacitance 값은 각각 1.06, 2.73, 2.94, 3.43, $2.78nF/cm^2$로 측정되었다. Threshold voltage, $V_{th}$는 각각 -0.4, -0.7, -1.6, -0.1, -0.2V를 나타냈다. 주파수에 따른 capacitance 변화율을 측정한 결과 Gl 물질 모두 주파수가 높을수록 capacitance가 점점 감소하는 경향을 보였으나 1${\sim}$2nF 이내의 범위에서 작은 변화율만 나타냈다. P3HT의 두께와 bake 온도를 변화시켜 C-V 값을 측정한 결과 차이는 없었다. FE-SEM으로 관찰한 결과에서도 두께나 온도에 따른 P3HT의 표면 morphology 차이를 확인할 수 없었다. 본 연구에서 PVK와 P3HT의 조합이 수율(yield)면에서 가장 안정적이면서 $3.43\;nF/cm^2$의 가장 높은 capacitance 값을 나타내고 $V_{th}$ 값 또한 -1.6V로 가장 낮은 값을 보였다.

  • PDF

Stability analysis of an existing utility tunnel due to the excavation of a divergence tunnel emerging from double-deck tunnel (복층터널의 분기터널 굴착에 따른 지하 공동구의 안정성 분석)

  • Nam, Kyoung-Min;Choi, Min-ki;Kim, Jung-Joo;Jafri, Turab H.;Yoo, Han-Kyu
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.2
    • /
    • pp.231-248
    • /
    • 2017
  • Government plans to construct a double-deck tunnel under a portion of Gyeongbu Expressway that will solve traffic problems and could also be used as a flood storage facility. Divergence tunnels connect the main tunnel to the urban areas and their construction effects on adjacent structures at shallow depth need to be analyzed. This study primarily includes the numerical analysis of construction effects of divergence tunnels on utility tunnels. The utility tunnel was analyzed for three cases of volume loss applied to the divergence tunnel and two cases of the angle between main tunnel and divergence tunnel ($36^{\circ}$ and $45^{\circ}$). The results show that the more the volume loss was applied and the shorter the distance was between utility tunnel and divergence tunnel, the more the utility tunnel was affected in terms of induced displacements, angular displacement and stability. The worst scenario was found out to be the one where the angle between main tunnel and divergence tunnel was $36^{\circ}$ and the distance between divergence tunnel and utility tunnel was 10 m, resulting in the largest displacement and differential settlement at the bottom of the utility tunnel. A relationship between the angular displacement and the distance to diameter ratio was also established.

Anisotropy Angle Dependence of Interlayer Exchange Coupling of Perpendicular Magnetic [CoFe/Pt/CoFe]/IrMn Multilayers ([CoFe/Pt/CoFe]/IrMn 다층박막의 수직자기 이방성 각도에 따른 상호교환결합력 특성)

  • Lee, Sang-Suk;Choi, Jong-Gu;Hwang, Do-Guwn;Rhee, Jang-Roh
    • Journal of the Korean Magnetics Society
    • /
    • v.18 no.6
    • /
    • pp.232-236
    • /
    • 2008
  • Dependence of interlayer exchange coupling on antiferromagnetic IrMn thickness, thermal stability, and parallel anisotropy angle in perpendicular anisotropy [CoFe/Pt/CoFe]/IrMn multilayers was investigated. The magnetic property of [CoFe($10{\AA}$)/Pt($8{\AA}$)/CoFe($10{\AA}$)] induced by antiferromagnetic ordering of IrMn layer was maintained a stable perpendicular anisotropy up to $250^{\circ}C$ and from $7{\AA}$ to $160{\AA}$ of IrMn thickness. The value of interlayer exchange coupling of [CoFe/Pt/CoFe]/IrMn multilayers with perpendicular anisotropy increased to 1.5 times at anisotropy angle of $60^{\circ}$ more than of $0^{\circ}$. On the other side, the interlayer exchange coupling at anisotropy angle of $90^{\circ}$ was $\infty$ Oe, it was likely diverted to a parallel shape magnetization.

Analysis on Energy Demand Resulting From the Change in Window Area & Installation of Interior Exterior Blinds (기존 노후건축물의 최적 리모델링 개선안 연구)

  • Kim, Dae-Won;Chung, Kwang-Seop;Kim, Young-Il;Nam, Ariasae;Oh, Se Min
    • Journal of Energy Engineering
    • /
    • v.23 no.2
    • /
    • pp.207-216
    • /
    • 2014
  • The energy loss can be divided into the loss caused by heat transfer and the loss caused by air flow. Heat transfer is the loss resulting from the heat transmittance of external wall, roof, and floor, and represents one of the most vulnerable elements of existing buildings. To prevent such loss, it is necessary to increase the mean heat transmittance of entire external wall, including the window, to a level above the standard regional value and ensure the air-tightness of window. The old buildings have the structure which is prone to the loss of greater air flow due to the air infiltration through the exit/entrance door upward along the stairway by the stack effect and simultaneous suction of air from each floor, and becomes even vulnerable to the loss of heat insulation for each floor, although the external wall and windows are the most vulnerable parts. The improvement plans for each floor need to be submitted in tandem with the diagnosis of whole building, regarding the diagnosis plan and energy improvement measures based on the survey of site, rather than adhering to the misconception that the replacement of window alone will result in energy-savings.