• Title/Summary/Keyword: 밀폐형 워터펌프

Search Result 4, Processing Time 0.022 seconds

Effect of Shape of Discharge Port on Hydraulic Performance of Automotive Closed Type Water Pump (자동차 밀폐형 워터펌프의 토출구 형상이 수력성능에 미치는 영향)

  • Heo, Hyung-Seok;Lee, Gee-Soo;Bae, Suk-Jung
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.1
    • /
    • pp.39-47
    • /
    • 2006
  • Recent trend in pursuit of high performance and effectiveness for automotive cooling system has changed the application of material for impeller of automotive water pump from metal to high ability engineering resin, which can achieve optimization of design of impeller geometry and realize lightweight high efficiency water pump. Closed type water pump improves hydraulic loss of fluid through the clearance between volute casing and impeller compared with that of the existing open type water pump(Although closed type is heavier than open type for the same size and same material, adoption of plastics can solve the problem.). In the present study, the characteristics of hydraulic performance of closed type water pump were investigated with respect to the angle between shroud and hub of impeller and the shape of discharge port of volute casing. Performance tests were carried out for 4 cases, that is, for 2 impellers and 2 casings. The modification of shape of only discharge port can enhance the hydraulic performance by 10 percent and the pump efficiency by 4-6 percent.

Reduction of the Axial Force of Water Pump Using CFD (전산유체역학을 이용한 워터펌프 축력 저감)

  • Jo, Sok-Hyun;Shin, Dong-Sung
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.3
    • /
    • pp.83-87
    • /
    • 2012
  • Computational Fluid Dynamics (CFD) method has been used to investigate the axial force of automotive water pump. As the excessive axial force can make some unexpected problems like impeller interference and coolant leakage we have focused on finding the cause of axial force and its reduction in this paper. First, we have tested the closed type water pump with and without balance hole by the calculation methods. By examining the pressure contour around the impeller, we have found that the axial force arises not only from the pressure difference around shroud but also from the pressure difference around hub. So we have tested two impellers - one is normal open type impeller and the other is open type impeller with modified hub. The results show that the axial force reduction is about 150~200N for normal one and 700N@3000RPM for modified impeller. And the hydraulic efficiency which is important in aspect of engine fuel efficiency is reduced about 6.5% for normal one but increased 4%@3000RPM for modified impeller.

Effects of the Balance Hole Diameter of an Automotive Closed Type Water Pump on Hydraulic Performance and Axial Force (자동차 워터펌프 밸런스 홀 직경이 수력성능 및 축추력에 미치는 영향)

  • Lee, Gee-Soo;Heo, Hyung-Seok;Kim, Hyun-Chul;Oh, Chang-Bok
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.3
    • /
    • pp.111-117
    • /
    • 2008
  • The aim of this paper was to investigate the fluid dynamic behavior of the automotive closed type water pump with balance hole in order to evaluate and justify its overall hydraulic performance and, in particular to analyze the effects of the balance hole on the reduction of hydraulic flow force of it. The analysis has been peformed by applying the commercial computational fluid dynamics (CFD) code, Fluent, to the solution of the 3-D turbulent flow fields of automotive closed type water pump. The reliability of the employed analysis was demonstrated by the comparison between numerical result and experimental data. Although, hydraulic head of the closed type water pump with 3mm diameter of balance hole decreased by 1.1%, axial flow force was effectively reduced by 13.3%, comparison of it with no hole at design point.

A Leak Inspection Automation System for Sealed SUS CAN Rotor (밀폐형 SUS CAN Rotor를 위한 Leak 검사 자동화 시스템)

  • Choi, Chang-min;Seo, Su-min;Shin, Gi-su;Park, Jong-won;Jung, Yeon-seok;Yoo, Nam-hyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2019.05a
    • /
    • pp.406-408
    • /
    • 2019
  • The motor applied to electric water pump used in automobiles is the canned type motor structure. The rotor, which is the driving component of the motor, is located in the bulkhead structure of the plastic injection molding, and rotates while immersed in the antifreeze. Plastic Injection Stator is placed on the outside of the bulkhead structure so that the rotor can rotate. The configuration of the rotor consists of magnet, core and shaft. In the case of magnet and core, it is very important to keep the parts sealed because it is a material that is corroded by moisture. When mounted on a vehicle, it must be capable of driving at $120^{\circ}C$ ambient conditions and should not leak under pressure of 1 bar or more. In this paper, we designed and implemented a Leak inspection automation system using helium to check the defects of the electric water pump developed satisfying this condition.

  • PDF