• Title/Summary/Keyword: 밀폐공간진입

Search Result 3, Processing Time 0.016 seconds

Effect of Virtual Reality Training for the Enclosed Space Entry (밀폐공간진입을 위한 가상현실(VR) 훈련의 효과)

  • Chae, Chong-Ju;Lee, Jin-Woo;Jung, Jin-Ki;Ahn, Young-Joong
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.2
    • /
    • pp.232-237
    • /
    • 2018
  • According to the MAIIF report, from 1998 to 2009, 101 incidents involving entering enclosed spaces aboard ships resulted in 93 deaths and 96 casualties. IMO has therefore amended the Recommendations for entering Enclosed Spaces Entry and SOLAS 1974 Convention Chapter 3 Regulation 19, which mandates enclosed spaces entry and rescue drill on a regular basis. The training of entering such enclosed spaces should be practical, recognizing all possible risks of entering enclosed spaces aboard ships, while also considering the safety of trainees during the training. Recently, educational contents utilizing virtual reality (VR) have been applied in various fields to improve education and training effects, and these methods have proven to have advantages in actual and repetitive learning without being limited to physical space. In this study, the effectiveness, characteristics and differentiation of training of entering enclosed spaces aboard ships using VR were compared with traditional class room lectures through quantitative evaluation and questionnaires of training participants. Through the evaluation and questionnaire, it was found that participants using VR understood and learned the required training elements better than the control group, all of whom were trained through the normal class room lecture. Moreover, participants reported to display preference for training with the help of VR. As a result of the study, it was confirmed that the learning effects of VR onboard training can be used as an effective training method, especially by using video and other types of simulators.

The study on performance evaluation of heat resistance and smoke control system using air-curtain system in tunnel (터널용 에어커튼 시스템의 내열 및 제연 성능 평가 연구)

  • Park, Byoung-Jik;Shin, Hyun-Jun;Yoo, Yong-Ho;Park, Jin-Ouk;Kim, Yang-Kyun;Kim, Hwi-Seong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.4
    • /
    • pp.743-755
    • /
    • 2018
  • Tunnel is a semi-closed structure similar to underground space where the smoke generated from fire fills the space fast while escaping from the space slow. Because of such characteristics, when the fire breaks out by traffic accident, the vehicles are jammed making it difficult for the people to evacuate from the scene as well as for the fire engine to gain access to the scene. For such reasons, tunnels are globally categorized into some disaster classes for differentiated facilities and operation approaches. In Korea, less than a 1 km-long tunnel accounts for 80.0% and such a short tunnel which is categorized into Class III is not required to have smoke control system. In this study, a full-scale fire test was conducted in a bid to apply air curtain system using heat-resistant sirocco fan to a less than 1 km-long tunnel. To that end, heat resistance test to verify the normal operation at $250^{\circ}C$ for 60 minutes was conducted. Consequently, despite of rapid rising-temperature and increasing-carbon dioxide inside the air curtain (direction of fire in tunnel), initial condition was found to have been sustained outside the air curtain (opposite direction of fire in tunnel).

A Study on the Fire Prevention Activities and Suppression Measures of Utility-Pipe Conduit (지하공동구 화재예방활동 및 진압대책에 관한 연구)

  • Lee, Jung-Il
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.4
    • /
    • pp.63-68
    • /
    • 2010
  • Utility-Pipe Conduit is, Housing and city effectively accommodate what they absolutely need power, communications, gas, pipeline, water supply, drainage, energy facilities etc, according to expansion of urban infrastructure are derived, several ways to solve problems in, collection facilities in place are maintained and managed facility. If Utility-Pipe Conduit is damaged, as well as national security, because their impact on society as a whole, by introducing large vulnerability in the fire prevention activities and suppression measures and disaster for our situation by introducing measures, comprehensive analysis of the fire risk, it shall establish fire prevention activities and suppression through analysis of Utility-Pipe Conduit design, institutional issues, the problem of fire protection facilities, fire spread phenomenon etc. Because of Utility-Pipe Conduit is an enclosed place, so incomplete combustion due to lack of oxygen supply that there are problem such dark smoke, carbon monoxide etc, toxic combustion products and heat generation and visual impairment is an issue difficult to enter. As well as fire prevention activities, the fire In light of the particularity of the under ground than above ground fire, so this phenomenon is weak fire fighting that fire to become effective fire fighting tactics, basically it is necessary difficulty softening, non-burn softening and prevent combustion expansion of the cable is installed on the Utility-Pipe Conduit, having to considering the specificity of the response command system and relevant organizations to establish an on-site, Structural identification and other information gathering required to record of Response agencies, keep air conditioning system 24 hours and strengthening Virtual Total Training of Response agen