• 제목/요약/키워드: 미터아웃 유량제어

검색결과 2건 처리시간 0.015초

전기체 구조시험의 덤프밸브 조절절차 개발; (Setup Procedure of Dump Valve for Full-Scale Airframe Test)

  • 김성찬;김성준;황인희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1252-1257
    • /
    • 2003
  • This paper present a procedure of meter-out flow control method for dump valve in full-scale airframe test. Emergency stop, which results in dump state, can be happened during full-scale airframe test by several causes. Because servo valve can't control hydraulics actuator in the dump state, pressure in cylinder chamber may rise abruptly and overload can be acted to the test article. In this paper, the procedure and technology of orifice setting are investigated to protect the test article from unexpected loads by dump. The test results show that the presented methods decrease peak loads and improve unloading characteristics of hydraulic actuators in the dump state.

  • PDF

과하중 방지기의 전기체 구조시험 적용에 관한 연구

  • 김성찬;채동철;김성준;황인희
    • 항공우주기술
    • /
    • 제2권2호
    • /
    • pp.11-17
    • /
    • 2003
  • 항공기 전기체 구조시험에 과하중 방지 밸브로 사용되는 미터-아웃방식의 유량제어 방법을 본 보고서로 소개하고자 한다. 전기체 구조시험에서는 여러 요인에 의해 비상시험 중지상태(덤프상태)가 발생하며, 이 상태가 되면 서보밸브의 전원이 차단되어 하중을 가하던 실린더의 양단에 외부조건에 따른 급격한 압력변화가 발생되고, 이 변화는 시험체에 과하중으로 가해진다. 본 연구에서는 덤프로 기인한 하중으로부터 시험체를 보호하기 위해 사용되는 오리피스 면적조절 기술에 대해 소개하였고 실제 시험에서 유압작동기의 덤프특성이 효과적으로 감소되고 있음을 확인하였다.

  • PDF