• Title/Summary/Keyword: 미세 이송 장치

Search Result 11, Processing Time 0.023 seconds

An Effect of the Micro Bubble Formation Depending on the Saturator and the Nozzle in the Dissolved Air Flotation System (DAF 공정에서 공기포화장치와 노즐 특성 별 미세기포 발생에 미치는 영향)

  • Park, S.C.;Oh, H.Y.;Chung, M.K.;Song, S.L.;Ahn, Y.H.
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.12
    • /
    • pp.929-936
    • /
    • 2013
  • The saturator and injection nozzle are important facilities on the dissolved air flotation process. To increase the formation of micro bubble, it is required to improve the air dissolving performance in the saturator and keep the pressure uniform from the saturator to the nozzle. This study aimed to evaluate the performance of the saturator and the hydraulic effect of the nozzle and the pipe structure. The air volume concentration, bubble size and bubble residual time were measured in the test. The saturator, which had mounted with the spray nozzle, showed a good performance for bubble formation. Also, the characteristics of micro bubble formation were influenced by pressure uniformity and flow velocity through the orifice in the nozzle.

Fabrication of a Micro Fluidic Device for Micro-FACS and Test of Electroosmosis (Micro-FACS용 미세 유첼 소자의 저작 및 전기삼투 구동 시험)

  • Choi, Eun-Soo;Kim, Geun-Young;Park, Tae-Gyu;Yang, Sang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2001.11a
    • /
    • pp.69-71
    • /
    • 2001
  • 본 논문에서는 FACS(fluorescence activated cell sorting)의 초소형화를 위한 미세 유체소자들을 플라스틱 기판에 집적하여 제작하고 전기삼투를 이용해서 세포가 일렬로 이송되는 특성을 시험한다. 제작된 미세 유체 소자는 유리 하부 기판과 플라스틱 상부 기판 및 전원장치로 구성된다. 상부기판은 세포를 주입하기 위한 샘플 측 레저버와 세포를 운반 및 일렬 이송이 가능하게 하는 버퍼를 저장할 두 개의 레저버가 있고 이들이 배출되는 레저버로 구성된다. 마이크로머시닝 기술을 이용하여 실리콘 기판 위에 미세 채널 몰드를 제작한 후 PDMS(polydimethylsiloxane)로 주물을 제작한다. $O_2$ 플라즈마를 이용하여 유리 기판과 PDMS 주물을 접합하며 제작된 채널에 적색 잉크와 bead를 샘플 측에 충전하고 버퍼 측에 sodium borate를 충전한 후 전기삼투로 구동시킨다. bead가 일렬로 이송되도록 전장을 조절하고 이때의 유속과 유량을 측정한다. 다양한 전장에 따른 실험을 통하여 채널의 구조를 최적화한다.

  • PDF

플라즈마 연질화 처리된 마이크로 구동 요소부품의 표면미세구조 변화

  • Lee, Sang-Min;An, Gyeong-Jun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2013.05a
    • /
    • pp.125-125
    • /
    • 2013
  • 기계부품 및 자동차부품 등의 내마모나 내피로성의 향상을 위한 표면처리로서 고주파처리, 침탄처리, 질화처리 등이 사용되고 있다. 최근에는 변형을 최소화 함으로써 후가공을 생략할 수 있는 질화처리가 주목받고 있다. 질화처리종류로는 염욕질화나 가스질화법이 사용되고 있으나, 이들에 비해 환경오염 및 공해가 적고 인체에 무해한 플라즈마 연질화법이 사용되고 있다. 플라즈마 연질화 기술은 IT기기의 제품에 적용되는 표면경화의 공정개발은 미비한 실정이다. 마이크로 구동 요소 부품중의 하나인 Leadscrew는 이송장치를 구성하는 핵심 부품으로 IT기기의 정밀 이송 및 구동제어에 사용되는 핵심 부품으로 사용되고 있으며, 리드스크류의 소재인 SWCH1018A(냉간압조용강선)은 표면 경도가 낮고 변형이 쉽기 때문에 표면 경화를 위한 플라즈마 연질화 기술을 이용하고자 했다. 본 연구는 플라즈마 연질화 공정을 적용한 시편의 표면경도를 높혀주고 변형을 최소화 할 수 있는 공정을 확인하는 것이다. 공정변수를 변화 시키면서 얻어진 시편의 표면미세 구조를 미소경도측정, XRD, SEM분석을 통하여 확인하였으며, 이를 통해 시편 표면경도를 높여주는 공정 조건을 도출하였다.

  • PDF

Development of LGP Dry Cleaning Equipment using ESD and Adhesive Roll (ESD와 점착 롤 제진을 이용한 LGP 건식 세정 장치 개발)

  • Ku, Ja-Yl;Jun, SungHo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.8
    • /
    • pp.195-201
    • /
    • 2014
  • In this paper, we developed a LGP(Light Guide Panel) dry cleaning system for particle cleaning using corona discharge and dry adhesive roll. Therefore, we design a cleaning mechanism that can be applied dry adhesive dust removal roll and ESD(electrostatic discharge) by using corona discharge. Also, we design and implementation of equipment, which can loading, unloading and transfer LGP automatically. The developed equipment is dust and particle cleaning experimental results to demonstrate its stability.

Generation of Fine Droplets in a Simple Microchannel (유체 소자를 이용한 미세 액적 생성)

  • Kim, Su-Dong;Kim, Young-Won;Yoo, Jung-Yul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.7
    • /
    • pp.671-677
    • /
    • 2010
  • In the present study, we designed a microfluidic platform for generating monodisperse droplets with diameters ranging from hundreds of nanometers to several micrometers. To generate fine droplets, T-junction and flow-focusing geometry are integrated into the microfluidic channel. Relatively large aqueous droplets are generated at the upstream T-junction and transported to the flow-focusing geometry, where each droplet is broken into smaller droplets of the desired size by the action of pressure and viscous stress. In this configuration, the flow rate of the inner fluid can be made very low, and the ratio of the inner- and outer-fluid flow rates in the flow-focusing region can be made very high. It has been shown that the present microfluidic device can generate droplets with diameters of approximately $1\;{\mu}m$ (standard deviation: <3%).

Selection of Main Factors by Experimental Analysis for Profile Blast Machining Based on Microparticle Blasting Equipment with a Two-Axis Sequence Control Stage (2축 시퀀스 제어 스테이지와 미세입자 분사장치에 의한 형상 분사가공시 실험계획법에 의한 주요인자 검출)

  • Hwang, Chul-Woong;Lee, Sea-Han;Wang, Duck Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.11
    • /
    • pp.64-69
    • /
    • 2020
  • To determine the effective factors for microparticle blasting with precise sequence position control in the x-axis and y-axis directions, we conducted a statistical experimental analysis of blasted square shapes by considering five condition factors. The control input and output were operated simultaneously by rotation-linear motion conversion and fine particles were blasted onto the aluminum specimen by precise position control driving using multiple execution codes. The micro-driving device used for processing was capable of microparticle blasting and of controlling the system through contact with a limit sensor at high speed and a two-degree-of-freedom driving mechanism. Our experiments were conducted on 1,050 specimens of pure aluminum (containing <1% of other elements). The effects of several factors (e.g., particle and nozzle diameters, blasting pressure, and federate and blasting cycle numbers) on the surface roughness and blasted surface's depth were verified through a statistical experimental analysis by applying the dispersion analysis method. This statistical analysis revealed that the nozzle diameter, the blasting pressure, and the blasting cycle number were the dominant factors.

Development of a Movable Dust Collector with High Efficiency for Ladle in Foundry (주물공장의 레이들용 고효율 이동형 집진장치 개발)

  • Hong, Jun Ho;Lee, Sang Hwan
    • Journal of Korea Foundry Society
    • /
    • v.41 no.1
    • /
    • pp.16-25
    • /
    • 2021
  • The development of technology to prevent environmental pollutants and reduce energy consumption has already become a very significant issue not only for the foundry industry but also for society as a whole. In this paper, we introduce a new dust collector developed for low energy consumption and high performance compared to a roof top dust collector. The roof top dust collector which is using widely in the domestic foundry plant has a low performance about the dust suction ability in spite of high energy consumption because it is installed in a high place to collect the whole dust from all processes in foundry. A dust collector away from dust sources inevitably has low energy efficiency. The development of an efficient collector for foundry is very difficult because the position of the dust source continues to change from the melting process to the pouring process. New dust collector is installed on the ladle transfer equipment such as cranes, hoists, and monorails to effectively respond to moving dust sources. The movable device, attached close to the source of dust, provides high performance even with low energy consumption. The new dust collector is expected to be an environment-friendly device that can be applied to the foundry.

The Grinding Machining Characteristics of $ZrO_2$ Ceramics Ferrule in the Chucking Alignment Error (척킹 평형 정렬 오차에 따른 지르코니아 세라믹스 페룰의 연삭 가공 특성)

  • Lee S.W.;Kim G.H.;Choi Y.J.;Choi H.Z.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.19-22
    • /
    • 2005
  • As the optical communication industry is developed, the demand of optical communication part is increasing. $ZrO_2$ ceramic ferrule is very important part which can determines the transmission efficiency and information quality to connect the optical fibers. In general $ZrO_2$ ceramic ferrule is manufactured by grinding process because the demands precision is very high. And the co-axle grinding process of $ZrO_2$ ceramic ferrule is to make its concentricity all of uniform before centerless grinding. When co-axle grinding of ferrule supported by two pin, pin chucking alignment accuracy is very important. This paper deals with the analysis of the chucking alignment experiment with parallel error on the micro feeding equipment. Thus, if possible be finding highly good the chucking alignment of two pin.

  • PDF

A Study on the MHD Micropump with Mixing Function (혼합 기능을 갖는 마이크로 펌프의 연구)

  • Choi, Bum-Kyoo;Kang, Ho-Jin;Kim, Min-Sock
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.6
    • /
    • pp.579-586
    • /
    • 2010
  • With the development of micrototal analysis systems (${\mu}TAS$), which is a result of enhancement of MEMS technology, rapid progress has been achieved in medical and biological research. The study of lab-on-a-chip (LOC) devices, which are types of ${\mu}TAS$ and which integrate the functions of mixing and analyzing tiny amounts of samples and reagents on one chip, has actively progressed. An LOC comprises microfluidic components such as micromixers and micropumps. Because the flow in a microfluidic system is generally laminar, it is very difficult to efficiently mix and feed fluid reagents. This paper presents the design and the method of fabrication of an MHD micropump for mixing fluids. By using this micropump, fluids are simultaneously mixed and pumped; this is achieved by coupling the Lorentz force and force exerted by an electric charge moving in an electric field.

Adsorption Characteristics of Toluene Vapor According to Pore Structures of Zeolite 5A Modified with Hydrochloric Acid (산으로 개질한 Zeolite 5A의 세공구조에 따른 Toluene Vapor의 흡착특성)

  • Lee, Song-Woo;Bae, Sang-Kyu;Kwon, Jun-Ho;Na, Young-Soo;An, Chang-Doeuk;Yoon, Young-Sam;Song, Seung-Koo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.8
    • /
    • pp.807-812
    • /
    • 2005
  • This study is to investigate the correlation of pore structures of Zeolite 5As modified with acid and their adsorption capacity of toluene vapor using the dynamic adsorption method. The experimental results showed that the modification with acid allowed more micropores and enlarged the existing pores. Toluene vapor was mainly adsorbed on the surface of pores over $15\;{\AA}$ in diameter. The equilibrium adsorption capacity of toluene vapor of the modified Zeolite 5As was in the range of $15{\sim}70\;mg/g$ and the equilibrium adsorption capacity was increased to f times than that of the Zeolite 5A. The correlation between the total cumulative surface area and the equilibrium adsorption capacity was hard to say linear. The correlation in diameter between the cumulative surface area in the range of over $15\;{\AA}$ and the equilibrium adsorption capacity gate the highest correlation factor of 0.997.