• Title/Summary/Keyword: 미세대류

Search Result 30, Processing Time 0.02 seconds

Local Heat Transfer Characteristics in Convective Partial Boiling by Impingement of Free-Surface/Submerged Circular Water Jets (미세 원형 충돌수제트의 부분 대류비등에 있어서 자유표면/잠입 제트의 국소 열전달 특성)

  • 조형희;우성제;신창환
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.6
    • /
    • pp.441-449
    • /
    • 2002
  • Single-phase convection and partial nucleate boiling in free-surface and submerged jet impingements of subcooled water ejected through a 2-mm-diameter circular pipe nozzle were investigated by local measurements. Effects of jet velocity and nozzle-to-imping-ing surface distance as well as heat flux on distributions of wall temperature and heat transfer coefficients were considered. Incipience of boiling began from far downstream in contrast with the cases of the planar water jets of high Reynolds numbers. Heat flux increase and velocity decrease reduced the temperature difference between stagnation and far downstream regions with the increasing influence of boiling in partial boiling regime. The chance in nozzle-to-impinging surface distance from H/d=1 to 12 had a significant effect on heat transfer around the stagnation point of the submerged jet, but not for the free-surface jet. The submerged jet provided the lower cooling performance than the free-surface jet due to the entrainment of the pool fluid of which temperature increased.

Computer Simulation for the Thermal Analysis of the Energy Storage Board (에너지 축열보드 열해석을 위한 컴퓨터 수치해석)

  • 강용혁;엄태인;곽희열
    • Journal of Energy Engineering
    • /
    • v.8 no.2
    • /
    • pp.224-232
    • /
    • 1999
  • Latent heat storage system using micro-encapsuled phase change material is effective method for floor heating of house and building. The temperature profile in capsule block and flow rate of hot water are important parameters for the development of heat storage system. In the present study, a mathematical model based on 3-D, non-steady state, Navier-Stokes equations, scalar conservation equations and turbulence model ($\kappa$-$\varepsilon$), is used to predict the temperature profiles in capsule and the velocity vectors in hot water pipe. The multi-block grids and fine grids embedding are used to join the circle in hot water pipe and square in capsule block. The phase change process of the capsule is quite complex not only because the size of phase change material is very small, but also because phase change material is mixed with the cement to form thermal storage block. In calculation, it's assumed that the phenomena of phase change is limited only the thermal properties of phase change material and the change of boundary is not happened in capsule. The purpose of this study is to calculate the temperature profiles in capsule block and velocity vectors in hot water pipe using the numerical calculation. Two kinds of thermal boundary condition were considered, the first (case 1) is the adiabatic condition for the both outside surfaces of the wall, the second (case 2) is the case in which one surface is natural convection with atmosphere and another surface is adaibatic. Calculation results are shown that the temperature profile in capsule block for case 1 is higher than that for case 2 due to less heat loss in adaibatic surface. Specially, in the domain of near Y=0, the difference of temperature is greater in case 1 than in case 2. The detailed experimental data of capsule block on the temperature profile and the thermal properties such as specific heat and coefficient of heat transfer with the various temperature are required to predict more exact phenomena of heat transfer.

  • PDF

A COMPARATIVE STUDY ON THE PHYSICAL PROPERTIES OF ORTHODONTIC PLIERS ACCORDING TO TYPES OF STERILIZATION (멸균 방법에 따른 교정용 플라이어의 물성 변화에 대한 비교 연구)

  • Cho, Il-Je;Son, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.28 no.2 s.67
    • /
    • pp.329-341
    • /
    • 1998
  • Sterilization has received much attention in orthodontic practices over the past several years. The present study was undertaken to investigate the effects of sterilization on the physical properties of orthodontic pliers-AEZ, Unitek, and Dentronix ligature cutters. This study was designed to examine the tips of ligature cutters before and after 200 and 400 sterilization cycles using the Bowmar RHT-1000, the Dentronix DDS-5000, and the Eschmann SES-2000. The tip surface and the fracture surface were observed with a scanning electron microscope. The microstructure was observed with an optical microscope. The hardness test was carried out with the mic개-Vickers hardness tester and the Rockwell C Scale hardness tester. The chemical composition was analyzed by energy dispersive X-ray spectrometer. The results of this study were as follows : 1. The number and the size of corrosion products on the tip surface and the proportion of cleavage planes in fractured specimen increased, but the hardness of the tip decreased in proportion to sterilization cycles. From these observations, it was considered that mechanical properities decreased in proportion to sterilization cycles. 2. The number and the size of chromium carbides increased in proportion to sterilization cycles. Coarse microstructure decreased mechanical properities. 3. The AEZ and Unitek ligature cutters were Fe-Cr stainless steels, but the Dentronix ligature cutter was Co-Cr alloy. There were many differences among manufactures, but the chemical composition was .not changed after sterilization cycles. 4. The tip edge of ligature cutter used in a clinic revealed microcracks with the SEM observation. Clinical experience confirmed that ligature cutters were gradually degraded by sterilization.

  • PDF

A Study on the High Temperature Thermal Conductivity Measurement of Nanofluid Using a Two-Phase Model (2상 모델을 이용한 나노유체의 고온 열전도도 측정 연구)

  • Park, Sang-Il;Lee, Wook-Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.2
    • /
    • pp.153-156
    • /
    • 2010
  • The effective thermal conductivity of two-phase materials such as unbonded silica sands saturated with a nanofluid was measured at high temperature using the transient thermal probe method. The nanofluid used in this study was a water-based mixture of 0.1 vol% $Al_2O_3$ nanoparticles with a diameter of 45 nm. The convection problem for fluids was prevented with this measurement method because the fluid was confined to within very small pore spaces. Based on the prediction model for unbonded sands, the thermal conductivities of the saturating nanofluid at high temperatures could be determined with the measured effective thermal conductivities for the two-phase material. In the results, increases in the thermal conductivity ratios of the nanofluid to pure water when temperatures were varied from $30^{\circ}$ to $80^{\circ}C$ were within the range of 4.87%~5.48%.

Effects of Outflow Area on Pool Boiling in Vertical Annulus (출구유로 단면적이 수직 환상공간 내부의 풀비등에 미치는 영향)

  • Kang, Myeong-Gie
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.4
    • /
    • pp.377-385
    • /
    • 2013
  • To identify the effects of an outflow area on pool boiling heat transfer in a vertical annulus, three different flow restrictors were studied experimentally. For the test, a heated tube of smooth stainless steel and water at atmospheric pressure were used. Both annuli with open and closed bottoms were considered. To validate the effects of the outflow area on the heat transfer, the results of the annulus with the restrictor were compared with the data for the plain annulus without the restrictor. The reduction of the outflow area ultimately results in a decrease in the heat transfer. As the outflow area is very small, a slight increase in heat transfer is also observed. The major cause of this tendency is explained as the difference in the intensity of liquid agitation cause by the movement of coalesced bubbles. It is identified that the convective flow, pulsating flow, and evaporative mechanism are considered as the important mechanisms.

A Study on the Characteristics of Solid Capacitor According to the Pyrolysis Methods (열분해 방식에 따른 고체 커패시터의 특성연구)

  • Kim, Jaekun;Yu, Hyungjin;Hong, Woonghee
    • Korean Chemical Engineering Research
    • /
    • v.44 no.6
    • /
    • pp.614-622
    • /
    • 2006
  • A Study on the characteristics of $Ta/Ta_2O_5/MnO_2$ capacitor applied $MnO_2$ by means of pyrolysis of manganese nitrate solution was carried out. Single phase of $MnO_2$ was obtained in the pyrolysis temperature range of 230 to $250^{\circ}C$ by TG/DSC analysis on manganese nitrate solution. Temperature of pyrolysis, concentration of manganese nitrate solution and the number of pyrolysis were selected for the basic parameters of embodying $MnO_2$ solid electrolyte and then the effects of these parameters on the characteristics of capacitor were estimated. The characteristics of capacitor pyrolyzed radiationally was superior to that of capacitor pyrolyzed convectionally on the basis of these optimized parameter conditions. It was verified that radiational pyrolysis formed smaller spherical $MnO_2$ particles than those of convectional one relatively and these facts resulted in forming uniform and dense solid electrolyte layer into the microporous sintered body of capacitor.

Adsorption of p-Xylene by Expanded Graphite (팽창흑연을 이용한 p-Xylene 흡착)

  • Lee, Chae-Young;Jee, Hyeong-Sub;Chung, Jae-Woo;Kim, Sang-Hyoun;Cho, Yun-Chul;Kang, Seok-Tae
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.5
    • /
    • pp.35-40
    • /
    • 2012
  • In this study, adsorption characteristics of expanded graphite (EG) were investigated by a series of batch adsorption tests using p-Xylene as a model volatile organic compounds (VOCs). After acid treatment, graphite were expanded at various temperature from $600^{\circ}C$ to $1000^{\circ}C$ for one minute. The optimal temperature was $800^{\circ}C$, where the expansion ratio reached 195 times of original volume. The BET specific surface area of EG was $92.4m^2/g$, which was only 1/10 of granular activated carbon (GAC), however the adsorption of p-Xylene by EG was almost completed within 5 minutes while that of GAC continued for 7 days because the majority of pores of EG was consisted with meso- and macro-pores. According to the Langmuir isotherm analysis, the maximum specific adsorption of p-Xylene onto EG was 24.0 mg/L with the adsorption constant of 7.94. In conclusion, the adsorption capacity of EG was much less than that of GAC due to the significantly lower specific surface area, but the first order kinetic constant was more than 500 times larger than GAC. Overall, EG might be effective where the fast adsorption is required.

A Novel Cooling Method by Acoustic Streaming Induced by Ultrasonic Resonator (초음파 진동자에 의해 유도된 음향유동을 이용한 첨단 냉각법)

  • 노병국;이동렬
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.3
    • /
    • pp.217-223
    • /
    • 2003
  • A novel cooling method induced by acoustic streaming generated by ultrasonic vibration at 30㎑ is presented. Ultrasonic vibration is obtained by piezoelectric devices and the maximum vibration amplitude of 50 m is achieved by including a horn, mechanical vibration amplifier in the system and making the complete system resonate. To investigate the enhancement of heat transfer capability of acoustic streaming, the temperature variations of heat source and air in the vicinity of heat source are measured in real-time. It is observed that acoustic streaming is instantly induced by ultrasonic vibration, resulting in the significant temperature drop due to the bulk air flow caused by acoustic streaming. In addition, it is observed that the cooling effect on the heat source is maximized when the gap between the ultrasonic vibrator and heat source coincides with the multiples of half-wavelength of the ultrasonic wave. This fact results from the resonance of the sound wave. The theoretical analysis of the dependence on the gap is also accomplished and verified by experiment. The advantage of the proposed cooling method by acoustic streaming is noise-free due to the ultrasonic vibration and maintenance-free because of the absence of moving parts. Moreover. This cooling method can be utilized to the nano and micro-electro mechanical systems, where the fan-based conventional cooling method can not be employed.

Relief of Residual Stress and Estimation of Heat-Treatment Characteristics for Al6061 Alloy by Cryogenic Heat Treatment (극저온 열처리에 의한 Al6061 합금의 잔류응력 제거 및 열처리 특성 평가)

  • Ko, Dae-Hoon;Park, Ki-Jung;Cho, Young-Rae;Lim, Hak-Jin;Lee, Jung-Min;Kim, Min-Byung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.10
    • /
    • pp.1145-1153
    • /
    • 2011
  • The purpose of this study is to relieve the residual stress of Al6061 using cryogenic heat treatment. Experimental T6 and cryogenic heat treatments were carried out to define the convective heat-transfer coefficient, which was then applied in the finite-element method (FEM) to predict the residual stress. The predicted residual stress was compared with the residual stress measured by X-ray diffraction (XRD), and the results were in good agreement. The mechanical properties were estimated by measuring the electrical conductivity and hardness. In addition, the size and formation of the precipitations were observed by TEM and XRD analysis for both T6 and cryogenic heat treatments. The effects of the cryogenic heat treatment on the residual stress, mechanical properties, and precipitation of Al6061 alloys were thus confirmed.

Photochemical Ozone Research in Korea - Present Status, Problems and Tasks (우리나라 광화학 오존 연구의 현황과 문제점, 과제)

  • 김영성;김용표
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 1998.10a
    • /
    • pp.83-92
    • /
    • 1998
  • 오존 경보제와 예보제의 실시가 오존 오염에 관한 일반인의 관심을 증폭시키는 중요한 계기가 되었음에도 우리 연구계와 정책 당국의 대응은 이에 훨씬 못미치고 있다. 1990년 이래 학회지 관련 논문 편수는 연간 1∼3편에 그치고 있고, 다른 이차오염 현상과 달리 정책 당국은 여전히 지원을 고려하지 않고 있다. 오존 연구가 뿌리를 내리지 못한 가운데 강행된 경보제와 예보제의 와중에 책임을 떠맡은 지방자치단체는 조급하게 노련한 예보 모델을 찾고 있고 충분한 검토도 없이 외국의 사례에서 대책을 구하고 있다. 논란이 되고 있는 오존 예보의 부정확성은 모델 선택의 문제가 아니라 모델 이용이 잘못된 때문이다. 현재 오존 대책의 일환으로 검토되고 있는 차량 부제 실시와 같은 단기 대책은 역효과를 낼 수 있다는 연구결과도 있다. 선진국의 오존 연구는 도시 규모에서 지역 규모로 확대되고 있고, 구츰 등 액상반응의 효과 규명과 1 kin 이하 미세 변화 모델링이 시도되고 있고, 지구 단위 대류권 실험의 일환으로 태평양 상공의 오존과 오존 전구물질의 대기화학이 조사되고 있다. 우리는 우선 우리의 오존 문제를 정확히 이해하도록 노력하여야 한다 합리적 계획 아래 체계적으로 접근하여 갈 때 당장은 아니지만 우리의 오존에 대한 이해가 깊어갈수록 예보의 정확성은 향상될 수 있다. 많은 비용과 노력이 필요한 오존 대책의 시행은 충분히 신중하여야 한다. 서울과 같은 대도시라면 적합한 수치모델을 구비하여 효과를 점검할 수 있어야 한다. 일부에서는 예보의 정확성을 높일 수 있는 방안의 하나로 수치모델 이용을 거론하고 있으나 수치모델은 매일의 예보와 같이 일상적 목적을 위하여 사용될 수 있는 모델이 아니며, 현재와 같이 기초가 갖추어져 있지 않은 상황에서는 더욱 그러하다. 정상적 모델 이용이 가능할 수 있도록 배출원 자료 체계를 갖추어야 하고, 서을 등 특징적 지역에 대하여서는 집중적 현장 조사를 실시하여야 한다.3)와 NAS(National Academy of Sciences, 1983), 미국에서 발행되는 정부 지침서 (Federal Register)에 고시된 내용 등을 토대로 하였다. 연구는 당면현실로 다가온 정보화 및 세계화의 기업환경에서 예견되는 몰입(committment)의 약화에 대한 치유방안으로서, 정보화된 경영모의게임의 기업 교육훈련 시스템(Business Training System)으로의 발전 가능성을 제시한다 하겠다.암시하며, 따라서 우리 교육문화에 맞는 재택수업 형태의 개발이 시급함을 제시한다고 하겠다.column density of HCaN is (1-3):n1014cm-2. Column density at distant position from MD5 is larger than that in the (:entral region. We have deduced that this hot-core has a mass of 10sR1 which i:s about an order of magnitude larger those obtained by previous studies.previous studies.업순서들의 상관관계를 고려하여 보다 개선된 해를 구하기 위한 연구가 요구된다. 또한, 준비작업비용을 발생시키는 작업장의 작업순서결정에 대해서도 연구를 행하여, 보완작업비용과 준비비용을 고려한 GMMAL 작업순서문제를 해결하기 위한 연구가 수행되어야 할 것이다.로 이루어 져야 할 것이다.태를 보다 효율적으로 증진시킬 수 있는 대안이 마련되어져야 한다고 사료된다.$\ulcorner$순응$\lrcorner$의 범위를 벗어나지 않는다. 그렇기 때문에도 $\ulcorner$순응$\lrcorner$$\ulcorner$표현$\lrcorner$의 성격과 형태를 외형상으로 더욱이 공간