• Title/Summary/Keyword: 물 흡수선량 교정인수

Search Result 5, Processing Time 0.017 seconds

Development of a Dose Calibration Program Based on an Absorbed Dose-to-Water Standard (물 흡수선량 표준에 기반한 선량교정 프로그램 개발)

  • 신동오;김성훈;박성용;서원섭;이창건;최진호;전하정;안희경;강진오
    • Progress in Medical Physics
    • /
    • v.14 no.3
    • /
    • pp.175-183
    • /
    • 2003
  • Absorbed dose dosimetry protocols of high energy photon and electron beams, which are widely used and based on an air kerma (or exposure) calibration factors, have somewhat complex formalism and limitations for improving dosimetric accuracy due to the uncertainty of the physical parameters used. Recently, the IAEA and the AAPM published the absorbed dose to water-based dosimetry protocols(IAEA TRS-398 and AAPM TG-51). The dose calibration programs for these two protocols were developed. This program for high energy photon and electron beams was also developed for users to use in a window environment using the Visual C++ language. The formalism and physical parameters of these two protocols were strictly applied to the program. The tables and graphs of the physical data, and the information of ion chambers were numericalized for their incorporation into a database. This program can be useful in developing new dosimetry protocols in Korea.

  • PDF

웹에 기반한 선량교정 프로그램 개발

  • 신동오;서원섭;박성용;김성훈;지영훈;김근배;이창건;강진오;홍성언
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.66-66
    • /
    • 2003
  • 목적 : 선량측정의 정확성을 향상시키기 위하여 물 흡수선량 표준에 토대를 두고 있는 표준측정법, AAPM TG-51과 IAEA TRS-398, 이 발표되어 선량측정의 파라다임이 변화하고 있다. 본 연구에서는 이들 대표적인 표준측정법에 대하여 사용자 편의성을 고려하여 웹에 기반한 선량교정 프로그램을 개발하고자 한다. 대상 및 방법 : 미국의학물리학회 AAPM TG-51과 국제원자력기구 IAEA TRS-398 표준측정법에 선량교정 프로그램은 Microsoft IIS 6.0 웹서버와 .NET 플렛폼상에서 Visual Studio. NET 도구를 사용하여 개발하였다. 개발언어로는 C# 언어를 사용하였고 각 표준측정법에 대한 선량교정 작업서는 ASP. NET 페이지로 작성하였다. 웹페이지와 산량 교정 모듈을 분리하여서 개발 후 유지보수가 쉽게 설계하였다. 또한 기준점에서의 선량 계상에 사용하는 모든 물리적인 파라미터와 데이터는 데이터베이스에 저장하였다. 이로써 향후 수식체계의 변화 또는 물리적인 데이터의 변화로 인한 프로그램 수정이 최소화하도록 하였다. 결과 : 이들 표준측정법은 모두 물 흡수선량 교정인수에 토대를 두고 있으나 측정 조건 및 물리적인 자료 에 있어 약간의 차이를 보이고 있다. 그러므로 각 표준측정법간의 유사점 및 차이점을 비교 분석하기가 용이하였다. 그리고 개발된 프로그램을 이용하여 표준측정법에서 제시된 선량교정 작업서에 따라 선량 교정을 수행한 교정 결과 데이터를 XML 파일 형식으로 저장하여 이전의 측정 자료를 관리할 수 있게 하였다. 이 과거 측정 자료를 사용하여 출력 선량 교정의 변화 및 기타 중요한 물리적인 데이터 값의 변화를 분석할 수 있다. 결론 : 두 표준측정법에 대한 선량교정 프로그램은 사용자가 선호하는 표준측정법을 선택할 수 있고, 웹에 토대를 두고 있어 프로그램으로 전국 방사선종양학과의 방사선치료기기의 출력 및 물리적인 변화에 대한 자료를 비교 분석하기 용이하고 수작업으로 인해 발생할 수 있는 실수 및 오차를 줄일 수 있다. 또한 개발된 프로그램의 활용을 통하여 국내 실정에 적합한 물 흡수선량 표준에 기반한 표준측정법 개발에 토대를 마련하는데 있어 기여할 것으로 사료된다.

  • PDF

Development of Web-based Dosimetry Calibration Program for High Energy Radiation (웹 기반 고 에너지 방사선에 대한 흡수선량 교정 프로그램 개발)

  • Shin Dong Oh;Shin Dong Ho;Kim Sung Hoon;Park Sung Yong;Seo Won Seop;Ahn Hee Kyung;Kang Jin Oh;Hong Seong Eon
    • Progress in Medical Physics
    • /
    • v.16 no.3
    • /
    • pp.116-124
    • /
    • 2005
  • Absorbed dose dosimetry protocols of high energy photon and electron beams, which are widely used and based on an air kerma calibration factors, have somewhat complex formalism and limitations for improving dosimetric accuracy due to uncertainty of the physical parameters used. Recently the IAEA and the AAPM published the absorbed dose to water-based dosimetry protocol. In this work web-based dose calibration program for IAEA TRS-398 and AAPM TG-51 protocols were developed. This program developed using the Visual C$\#$ language can be used in the internet. User selectable dosimetry protocol on the web allows the absorbed dose to water data of the two protocols at a reference point to be easily compared, and enables to conveniently manage and understand the current status of the dosimetry calibration performed at participating institutions in korea. This program and the resultant database from the web-based calibration can be useful in developing new dosimetry protocols in Korea.

  • PDF

Practical Output Dosimetry with Undefined $N_{dw}{^{Co-60}}$ of Cylindrical Ionization Chamber for High Energy Photon Beams of Linear Accelerator ($N_{dw}{^{Co-60}}$이 정의되지 않은 원통형 이온전리함을 이용한 고에너지 광자선의 임상적 출력선량 결정)

  • Oh, Young-Kee;Choi, Tae-Jin;Song, Ju-Young
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.114-122
    • /
    • 2012
  • For the determination of absorbed dose to water from a linear accelerator photon beams, it needs a exposure calibration factor $N_x$ or air kerma calibration factor $N_k$ of air ionization chamber. We used the exposure calibration factor $N_x$ to find the absorbed dose calibration factors of water in a reference source through the TG-21 and TRS-277 protocol. TG-21 used for determine the absorbed dose in accuracy, but it required complex calculations including the chamber dependent factors. The authors obtained the absorbed dose calibration factor $N_{dw}{^{Co-60}}$ for reduce the complex calculations with unknown $N_{dw}$ only with $N_x$ or $N_k$ calibration factor in a TM31010 (S/N 1055, 1057) ionization chambers. The results showed the uncertainty of calculated $N_{dw}$ of IC-15 which was known the $N_x$ and $N_{dw}$ is within -0.6% in TG-21, but 1.0% in TRS-277. and TM31010 was compared the $N_{dw}$ of SSDL to that of PSDL as shown the 0.4%, -2.8% uncertainty, respectively. The authors experimented with good agreement the calculated $N_{dw}$ is reliable for cross check the discrepancy of the calibration factor with unknown that of TM31010 and IC-15 chamber.

Quality Assurance Program of Electron Beams Using Thermoluminescence Dosimetry (열형광선량계를 이용한 전자선 품질보증 프로그램에 관한 연구)

  • Rah Jeong-Eun;Kim Gwe-Ya;Jeong Hee-Kyo;Shin Dong-Oh;Suh Tae-Suk
    • Progress in Medical Physics
    • /
    • v.16 no.2
    • /
    • pp.62-69
    • /
    • 2005
  • The purpose of this study has been performed to investigate the possibility of external audit program using thermoluminescence dosimetry for electron beam in korea. The TLD system consists of LiF powder, type TLD-700 read with a PCL 3 reader. In order to determine a calibration coefficient of the TLD system, the reference dosimeters are irradiated to 2 Gy in a $^{60}CO$ beam at the KFDA The irradiation is performed under reference conditions is water phantom using the IAEA standard holder for TLD of electron beam. The energy correction factor is determined for LiF powder irradiated of dose to water 2 Gy in electron beams of 6, 9, 12, 16 and 20 MeV (Varian CL 2100C). The dose is determined according to the IAEA TRS-398 and by measurement with a PTW Roos type plane-parallel chamber. The TLD for each electron energy are positioned in water at reference depth. In this study, to verify of the accuracy of dose determination by the TLD system are performed through a 'blind' TLD irradiation. The results of blind test are $2.98\%,\;3.39\%\;and\;0.01\%(1\sigma)$ at 9, 16, 20 MeV, respectively. The value generally agrees within the acceptance level of $5\%$ for electron beam. The results of this study prove the possibility of the TLD quality assurance program for electron beams. It has contributed to the improvement of clinical electron dosimetry in radiotherapy centers.

  • PDF