• Title/Summary/Keyword: 물의 상태변화

Search Result 1,579, Processing Time 0.042 seconds

A Numerical Model of Reinforced Concrete Members Exposed to Fire and After-Cooling Analysis (화재 및 화재 후 냉각상태의 철근콘크리트 부재 수치해석)

  • Hwang, Ju-Young;Kwak, Hyo-Gyoung
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.1
    • /
    • pp.101-113
    • /
    • 2015
  • This paper introduces a numerical analysis method for reinforced-concrete(RC) members exposed to fire and proposes considerations in designing RC structures on the basis of the comparison between numerical results and design codes. The proposed analysis method consists of two procedures of the transient heat transfer analysis and the non-linear structural analysis. To exactly evaluate the structural behavior under fire, two material models are considered in this paper. One is "Under-Fire" condition for the material properties at the high temperature and the other one is "After-Cooling" condition for the material properties after cooling down to air temperature. The proposed method is validated through the correlation study between experimental data and numerical results. In advance, the obtained results show that the material properties which are fittable to the corresponding temperature must be taken into account for an accurate prediction of the ultimate resisting capacity of RC members. Finally, comparison of the numerical results with the design code of EN1992-1-2 also shows that the design code needs to be revised to reserve the safety of the fire-damaged structural member.

Misunderstanding and Understanding of the Phase Diagram for Water: Water Evaporation and Ice Sublimation in the Atmosphere (물의 상평형 그림에 대한 오해와 이해: 대기 중 물의 증발과 얼음의 승화)

  • Park, Jong-Yoon
    • Journal of the Korean Chemical Society
    • /
    • v.51 no.6
    • /
    • pp.577-584
    • /
    • 2007
  • The purpose of this study is to suggest how to use the phase diagram for water to explain the evaporation and sublimation in the atmospheric condition. In principle, the phase diagram for water represents a one component system so it cannot be applied to the water contact with the air. When the liquid or solid phase of water exists in the air, always water vapor also exists in the air. In this case, we cannot present this state as a single point on the phase diagram because the pressure of the liquid or solid is different from that of the vapor in the air. However, since the saturation vapor pressure of liquid or solid is altered by negligible amount due to the presence of air, the evaporation and sublimation in the atmospheric condition can be explained using the vapor pressure line and sublimation line on the phase diagram.

Microstructure Observation of Pd-Cu-Ga system Dental Alloy in Clinical Heat Treatment (치과용 Pd-Cu-Ga 계 함금의 임상조건에 따른 미세조직 관찰)

  • 김기주;이진형
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.4
    • /
    • pp.443-449
    • /
    • 1999
  • 현재 시판되고 있는 치과용 76.5%Pd-11.6%Cu-7.2^%GarP 합금의 주조상태 및 임상열처리에 따른 미세조직의 변화를 X-선 회절기, 광학현미경, 시차열분석기를 이용하여 관찰하였다. 주조상태, 탈개스 및 세리믹소성처리 후 미세조직은 Pd고용체와 금속간화합물 Pd2Ga으로 구성되어 나타났고, 이들 상들은 열처리에 따라 상당한 변화를 보였다. 또한 Pd은 아르곤 분위기 내의 산소와 반응하여 산화물 형성 및 분해로 인해 질량변화곡선(TG)이 변하였고, 시차열분석(DTA)에서는 약 815$^{\circ}C$ 정도에서 Pd2Ga에 기인하는 흡열피크를 확인하였다. 이러한 실험의 결과들은 Cu가 이원계 Pd-Ga 합금의 Ga의 고용량을 낮추어 공정반응이 저 Ga 쪽으로 이동하기 때문인 것으로 설명하였다. 그러나 앞으로 보다 명확한 상변태 규명을 위해서 TEM등의 분석장비를 사용하여 체계적인 연구가 요구된다.

  • PDF

States of Am in Aqueous Solution (수용액중의 Am의 상태)

  • Won Mok Jae
    • Nuclear Engineering and Technology
    • /
    • v.14 no.4
    • /
    • pp.172-177
    • /
    • 1982
  • The state of Am in the concentration of 10$^{-5}$M has been studied in the pH range of 5 to 10 by filtration and centrifugation method. By the experiments, we could estimate possible Am hydrolysis products and solubility constants. If the solubility of Am (OH)$_3$ estimated by Baes and Mesmer is increased about a factor of 10, i.e. changing logk=-l8.7 to logk=-17 5 it was found that the calculated curve of Am concentration versus pH agreed completely with experimental values.

  • PDF

Feasibility Study of Hyperspectral Image-based Remote Sensing Technique for Water Infrastructure Facilities (물 인프라 시설물의 초분광 영상 기반 원격탐사 기술 적용성 검토)

  • Ho Jun You;Dong Kyu Jung;Hyun Cheol Jo;Ki Young Kim
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.55-55
    • /
    • 2023
  • 물 인프라 시설물은 다양한 산업 및 지역 사회에 필요한 물 공급과 이와 관련된 인프라를 제공하는 현대 사회의 중요한 구성 요소 중 하나이다. 이러한 시설이 노후화 되면서 안전과 신뢰성에 대한 우려가 커지면서 과거 건설, 개발 중심에서 유지, 관리 중심으로 패러다임이 변화하고 있다. 이에 물 인프라 시설물의 상태를 정밀하게 조사하고, 정확한 계측하는 기술에 대한 수요가 지속적으로 증가하고 있다. 최근, 드론에 초분광 센서를 탑재하여 초분광 영상을 수집할 수 있는 기술이 개발되고 있으며, 물 인프라 시설물에 대한 원격탐사 및 모니터링이 이러한 수요를 만족시킬 수 있는 유망한 해결책으로 부상하고 있다. 특히, 이러한 초분광 영상 수집 기술을 이용하면 물 인프라 시설물 주변의수심, 수질, 온도 등 환경적 요인 뿐만 아니라 재료에 따른 상태를 파악할 수 있어, 잠재적으로 구조 결함을 감지하는데 필요한 상세한 분광 정보를 수집할 수 있다. 또한, "저수지·댐의 안전관리 및 재해예방에 관한 법률"에서 정기적인 정밀안전진단을 요구하고 있으며, "중대재해처벌법"에 따라 인력중심의 조사, 계측 방식의 어려움이 있는 상황에서 드론 기반의 초분광 원격탐사 기술은 매력적인 선택지이다. 본 연구는 안전과 신뢰성에 대한 우려가 커지고 있는 물 인프라 시설물에서 드론 기반 초분광영상 기술이 제공하는 새로운 해결책에 대한 연구로, "저수지·댐 안전관리 및 재해예방에 관한 법률"에서 제시하는 물 인프라 시설의 정기적인 검사 및 유지보수에 대한 중요성을 더욱 강조하는 것으로, 물 인프라 시설물을 정확하게 모니터링하고 조사, 계측하는 능력의 중요성을 증가시킬 수 있는 기술이다. 따라서 본 연구에서는 드론 기반의 초분광 영상 수집 기술을 활용하여 물 인프라시설물의 원격탐사 및 모니터링에 대한 적용성을 검토하고자 한다. 이를 통해 드론 기반 초분광영상 기술이 물 인프라 시설물의 조사 및 계측, 유지 보수에 대한 새로운 해결책이 될 수 있는지 검토한다. 또한 이 기술의 잠재적인 이점과 한계를 탐구하고, 정확하고 신뢰성 높은 계측, 조사 기술에 대한 증가하는 수요를 충족시키기 위한 능력을 평가 하고자 한다.

  • PDF

Analysis of electrical resistivity characteristics according to the mixing ratio of coarse fillings in artificial rock joint (인공 암반절리의 조립토 충진물 혼합비에 따른 전기비저항 특성 분석)

  • Haeju Do;Tae-Min Oh;Hangbok Lee
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.25 no.2
    • /
    • pp.141-155
    • /
    • 2023
  • Monitoring technology based on electrical resistivity is widely used for non-destructive data collection and health analysis of underground structures and tunnels. Vulnerable sections such as fault zone generates many problems during construction of the tunnel. These problems cause displacement and stress changes of the ground. Therefore, it is necessary to predict the state of the fault zone section to ensure the mechanical stability of the underground structure. Monitoring the size of joints and the porosity of the fillings is essential for rocks. Previous studies have not considered the variety of fillings in rock joints. In this study, electrical resistivity tests were conducted according to the particle mixing state of the sandy fillings. When the size of fillings is decreased at the constant porosity, the electrical resistivity tends to increase. The results of this study are expected to be useful as basic electrical resistivity data for predicting the ground conditions and evaluation of the ground behavior that is containing sandy fillings in the rock joint for tunnels.

Ecohydrological Effects of Climate and Land-Use Changes in Jeju Island using Ecosystem Demography Model (ED 모형을 활용한 제주도의 기후 변화 및 토지 이용 변화의 생태수문학적 영향)

  • Kim, Jeongbin;Kim, Yeonjoo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.107-107
    • /
    • 2018
  • 기후 변화가 심해짐에 따라 한반도의 기후 또한 온대에서 아열대로 변화하고 있다. 기후대가 변하게 되면 수문학적 순환 및 식생의 분포 또한 달라지게 된다. 식생의 분포는 결국 토지 이용을 의미하며, 서로 다른 토지 이용은 대기와의 상호작용을 통해 각기 다른 반응을 보이게 된다. 본 연구에서는 기후대가 가장 빠르게 변화하고 있는 제주도를 대상으로 기후 변화 및 토지 이용 변화에 따른 생태수문학적 영향을 Ecosystem Demography Model version 2.2(ED-2.2) 모형을 사용하여 살펴 본다. 제주도의 플럭스 타워 및 산림 조사 자료를 활용하여 ED-2.2 모형을 검증하였다. CRU-NCEP 기상자료 및 Land-Use Harmonization (LUH) 토지이용자료를 활용하여 과거기간(1500~2015)의 잠재 식생 및 실제 식생 상태를 산정하고 그 차이를 분석하였다. 산정된 최종 실제 식생 상태를 바탕으로 기후 및 토지이용 시나리오(RCP 3.0 및 6.0)를 적용하고, 다양한 전지구모형(GFDL-ESM2M, HadGEM2-ES, IPSL-CM5A-LR, MIROC5)의 기상자료에 따라 물 순환, 탄소 순환 및 식생의 분포가 어떻게 달라지는 지 분석한다.

  • PDF

A Study on the Motion Responses about Shape Variety of Semi-submersible Rig (반잠수식 Rig의 형상 변화에 따른 운동 성능에 관하여)

  • Park, Ro-Sik;Lee, Ok-Kyu;Kwak, Suk-Hwan
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.198-203
    • /
    • 2002
  • 본 연구에서는 반잠수식 Rig의 형상에 따른 최적 형상을 검토하기 위하여 최근 건조되고 있는 4-Column과 2-Lowhull을 가진 사각 Column에 원통형 Column을 혼합한 혼합형 과 4각 Column형을 공시모형으로 택하여 규칙파중 두 구조물에 작용하는 유체력과 유체력에 의한 운동 응답을 계산하고, 4각 Column을 가지는 구조물의 길이, 폭, 홀수를 변화시킨 Series 에 따른 유체 역학적 특성과 동요 진폭의 관계를 검토하였다. 수치계산은 3차원 특이점 분포법을 이용하여 정상상태에 대하여 실행하였다. 구조물의 형상과 역학적인 간섭의 영향을 이용, 보다 성능이 우수한 형상을 얻을 수 있음을 확인하였다.

  • PDF

The Influences of Bowel Condition with Lumbar Spine BMD Measurement (요추부 골밀도 측정 시 장내 변화가 골밀도에 미치는 영향)

  • Yoon, Joon;Kim, Yun-Min;Lee, Hoo-Min;Lee, Jung Min;Kwon, Soon-Mu;Cho, Hyung-Wook;Kang, Yeong-Han;Kim, Boo-Soon;Kim, Jung-Soo
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.273-278
    • /
    • 2014
  • Bone density measurement use of diagnosis of osteoporosis and it is an important indicator for treatment as well as prevention. But errors in degree of precision of BMD can be occurred by status of patient, bone densitometer and radiological technologist. Therefore the author evaluated that how BMD changes according to the condition of the patient. As Lumbar region, which could lead to substantial effects on bone density by diverse factors such as the water, food, intentional bowels. We recognized a change of bone mineral density in accordance with the height of the water tank and in the presence or absence of the gas using the Aluminum Spine Phantom. We also figured out the influence of bone mineral density by increasing the water and food into a target on the volunteers. Measured bone mineral density through Aluminum Spine Phantom had statistically significant difference accordance with increasing the height of water tank(p=0.026). There was no significant difference in BMD according to the existence of the bowl gas(p=0.587). There was no significant difference in a study of six people targeted volunteers in the presence or absence of the food(p=0.812). And also there was no significant difference according to the existence of water(p=0.618). If it is not difficult to recognize the surround of bone in measuring BMD of lumbar bone, it is not the factor which has the great effect on bone mineral density whether the test is after endoscopic examination of large intestine and patient's fast or not.

An Experimental Study on Electromagnetic Properties in Early-Aged Cement Mortar under Different Curing Conditions (양생조건에 따른 초기재령 시멘트 모르타르의 전자기 특성에 대한 실험적 연구)

  • Kwon, Seung-Jun;Song, Ha-Won;Maria, Q. Feng
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.5A
    • /
    • pp.737-746
    • /
    • 2008
  • Recently, NDTs (Non-Destructive Techniques) using electromagnetic(EM) properties are applied to the performance evaluation for RC (Reinforced Concrete) structures. Since nonmetallic materials which are cement-based system have their unique dielectric constant and conductivity, they can be characterized and changed with different mixture conditions like W/C (water to cement) ratios and unit cement weight. In a room condition, cement mortar is generally dry so that porosity plays a major role in EM properties, which is determined at early-aged stage and also be affected by curing condition. In this paper, EM properties (dielectric constant and conductivity) in cement mortar specimens with 4 different W/C ratios are measured in the wide region of 0.2 GHz~20 GHz. Each specimen has different submerged curing period from 0 to 28 days and then EM measurement is performed after 4 weeks. Furthermore, porosity at the age of 28 days is measured through MIP (Mercury Intrusion Porosimeter) and saturation is also measured through amount of water loss in room condition. In order to evaluate the porosity from the initial curing stage, numerical analysis based on the modeling for the behavior in early-aged concrete is performed and the calculated results of porosity and measured EM properties are analyzed. For the convenient comparison with influencing parameters like W/C ratios and curing period, EM properties from 5 GHz to 15 GHz are averaged as one value. For 4 weeks, the averaged dielectric constant and conductivity in cement mortar are linearly decrease with higher W/C ratios and they increase in proportion to the square root of curing period regardless of W/C ratios.