• Title/Summary/Keyword: 물벼룩 감시장치

Search Result 3, Processing Time 0.019 seconds

Application of Daphnia magna Monitoring System for Real-time Ecotoxicity Assessment (실시간 생태독성 평가를 위한 물벼룩 감시장치 적용성 검토)

  • Lee, Jang-Hoon;Ko, Woong-Tae
    • Journal of Digital Convergence
    • /
    • v.17 no.10
    • /
    • pp.1-12
    • /
    • 2019
  • In this study, TI(Toxic Index) of Daphnia toximeter corresponded to ecological toxicity standard 1 TU(Toxic Unit) was set up using Daphnia toximeter and when operating NOEC(water quality standards for drinking water) and $EC_{50}$ Daphnia toximeter alarm was issued appropriately, which enables real time ecological toxicity evaluation. I studied to get a good shot and the research was conducted by investigating domestic and international related data and conducting a preliminary study. 6 of 59 hazardous substances (As, Hg, Cr, Diazinon, Dioxane, and Phenol) recommended by the water quality monitoring items for artificial river water were selected and static, dynamic and quality management test, TI was shown to be good in other materials except Diazinon, and as a result of $EC_{50}$ spiking test, TI was matched to TU by distinguishing between 1 TU and 1 TU. in suggesting the complementary point of ecological toxicity management system and the future of research on water Daphnia toximeter.

Implementation of Real-time Measurement Hardware for Activity of Water Flea and Remote Monitoring System using CCD Camera (CCD 카메라를 사용한 물벼룩의 실시간 활동량 측정 하드웨어와 원격 모니터링 시스템 구현)

  • Park, Se-Huyn;Park, Se-Hoon;Kim, Eung-Soo
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.5
    • /
    • pp.30-37
    • /
    • 2007
  • Hardware for monitoring the water quality is developed using water fleas. Water flea is a frequently used biological sensor for monitoring the water quality. Water fleas quickly respond to the incoming toxic water by changing their activity when they are exposed. By measuring the activity of water fleas, the incoming toxic water is instantly detected in real time. So far the measurement of activity of water fleas has been done with a system equipped with a light source of LED and a light detector of photo transistor. Water flea itself is, however, sensitive to light resulting in incorrect response and the system has two inconvenient separate parts of the light source and the detector. This paper suggests a system using a CCD camera instead of a light source and a detector. The suggested system processes the image data from the CCD camera in real time without any delay. The developed system becomes a part of the remote water monitoring embedded system.

Study on Improving Reliability of Biomonitor by Using CCD Camera (CCD카메라를 이용한 생물감시장치의 독성자료 신뢰성 향상에 관한 연구)

  • Kim, Hyun-Chang;Kim, Young-Suk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.10
    • /
    • pp.1351-1357
    • /
    • 2010
  • Water monitoring equipments using daphnia can be used to monitor the pollution levels of a country's main rivers. Such equipments should be capable of providing a prompt warning about increase in the contamination levels, which is evaluated on the basis of impulse number or toxicity index. As unmanned remote control equipments, they must provide reliable pollution monitoring results for each season and for the annual physical changes in each river. Two different equipments based on the impulse number and toxicity index showed different results for the operating rates and for the number of emergency checks required even though both were operated at the same conditions. The results are affected by many parameters such as the presence of any air bubbles and the microscopic pressure. The purpose of this study is to develop a method that can reduce the effect of bubbles or microscopic pressure on the monitoring data. We expect to achieve reliable monitoring data for water pollutants irrespective of the location of the equipment setup.