• Title/Summary/Keyword: 물결합재비

Search Result 45, Processing Time 0.025 seconds

Characteristics of the floor impact sound by water to binder ratio of mortar (마감모르타르 물결합재비에 따른 바닥충격음 특성 변화)

  • Lee, Won-Hak;Haan, Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.6
    • /
    • pp.671-677
    • /
    • 2021
  • The present study aims to investigate the influence of the water to binder ratio of finishing mortar on the floor impact sound of apartments. For this, same resilient materials Expanded Polystyrene (EPS) with constant dynamic stiffness and different mortar layers with 52 %, 66 % and 72 % water to binder ratio respectively were used to build floating floor structures on which floor impact sounds were measured in standard testing facilities. As a result, it was found that light-weight floor impact sound was transmitted well when the water to binder ratio was 52% due to the high density. In case of heavy-weight floor impact sounds, since water to binder ratio of finishing mortar becomes higher as the weight of upper layer of resilient material lighter, it was shown that the natural frequency of floating floor structure moves to 63 Hz bandwidth which eventually cause a higher sound pressure level of floor impact sound. Thus, effect of water to binder ratio of mortar on the heavy-weight floor impact sounds was investigated.

An Experimental Study on the Properties of High Flowing Concrete according to Water/Binder Ratio(W/B) (물결합재비에 따른 고유동콘크리트의 특성에 관한 실험적 연구)

  • 김무한;최세진
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.4
    • /
    • pp.329-335
    • /
    • 2001
  • Recently, in many laboratories and institutes it is being studied on the high flowing concrete widely, which has high fluidity, non-segregation ability and fillingability, and sometimes being applied to the construction field actually. And the fluidity properties of high flowing concrete are influenced according to the several factors ; binder content, water/binder ratio and water content etc. This is an experimental study to compare and analyze the effect of water/binder ratio and water content on the properties of high flowing concrete. For this purpose, the mix proportion of high flowing concrete according to water/binder ratio(W/B : 0.30, 0.35, 0.40, 0.45) and water content (W : 155, 165, 175, 185 kg/㎥) was selected. And then slump-flow, V-lot, L-passing test in fresh concrete, and compressive strength, freezing and thawing test in hardened concrete were peformed. According to test results, it was found that the viscosity of all those high flowing concrete with the water content 175 kg/㎥ was satisfied with 50 cm pass time of slump flow prescribed by Japanese Architectural Standard Specification (JASS 5) - from 3 to 8 seconds. And non-segregation ability of concrete with W/B 0.35 was better than the other mix proportions. Especially, the compressive strength after curing 24 hours(1 day) of all high flowing concrete was higher than that prescribed by JASS 5(50 kgf/㎠).

Compressive and Tensile Properties of Highly Ductile Composites According to Water-binder Ratio and Fiber Type (물-결합재 비율과 섬유 종류에 따른 고연성 복합재료의 압축 및 인장특성)

  • Se-Eon Park;Bang Yeon Lee
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.12 no.2
    • /
    • pp.135-142
    • /
    • 2024
  • The purpose of this study is to experimentally investigate the effect of water-binder ratio and fiber type on the compressive strength and tensile performance of fiber reinforced highly ductile composites. To achieve this, four different mixtures were prepared by varying the water-binder ratio and fiber type, and compression and tension tests were conducted. The test results showed that the influence of fiber type on compressive strength was minimal, however, the WB50 series mixture exhibited a 29 % lower strength compared to the WB40 series mixture, indicating a significant effect of the water-binder ratio. On the other hand, the effect of fiber type on tensile properties was found to be more significant than that of the water-binder ratio. Tensile strain capacity ranged from 2.9 % to 6.2 %, with PE series mixtures showing 1.63 to 2.14 times higher performance compared to PVA series mixtures. Additionally, the crack patterns of the PE series mixtures were superior than those of the PVA series mixtures.

An Experimental Study on the Acid-Resistance of Concrete ―Focused on concrete with silica sand particles (콘크리트 내산성에 관한 실험적 연구-규사 분말 치환 콘크리트를 중심으로-)

  • 윤보현;부척량
    • Magazine of the Korea Concrete Institute
    • /
    • v.9 no.5
    • /
    • pp.127-135
    • /
    • 1997
  • This paper is an experimental study of the acid-resistance of concrect which contains silica sand particles. In the concerete sample experiment. the workability and strengh as well as the acid-resistance of the hardended concrect is inverstigated.

A Study on the Properties of Foamed Concrete with Plaster Using the Experimental Design (실험계획법을 이용한 석고 혼입 기포콘크리트의 특성에 관한 연구)

  • Lee, Sang-An;Kim, Wha-Jung;Yoon, Sang-Chun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.6
    • /
    • pp.130-137
    • /
    • 2013
  • This research was performed through the experimental design to get the statistical analysis on foamed concrete mixed plaster with hydrogen peroxide. In this experiment, we set the ratio of each material, which part of lightweight concrete, as experimental factors and evaluated on the mechanical properties by statistical analysis for response variables obtained from experiments. Experimental factors are plaster replacement, water binder ratio, and hydrogen peroxide ratio. Response variables are dry density, compressive strength, and flexural strength. Mixing design of the foamed concrete set up a total of 15 experimental points by Box-Behnken (BB) method of the response surface analysis. Thus, the results of a study were summarized as follows. Values of the probability in experimental factors (plaster replacement, water binder ratio and hydrogen peroxide ratio) on the response variables were estimated to be significant at the 95% of confidence limit. On response surface analysis for dry density of foamed concrete, water binder ratio and hydrogen peroxide ratio were estimated to be significant (${\alpha}$ = 0.05), and the relationship between the amount of void and the water content for dry density is inverse proportional. On response surface analysis for the compressive strength of foamed concrete, water binder ratio, hydrogen peroxide ratio and (hydrogen peroxide ratio)$^2$ was estimated to be significant (${\alpha}$ = 0.05). On response surface analysis for the flexural strength of foamed concrete, water binder ratio, hydrogen peroxide ratio was estimated to be significant (${\alpha}$ = 0.05). Through multi response surface analysis, we found the optimal area that meets performance goals.

A Study on Chloride Diffusion in Concrete Containing Lightweight Aggregate Using Crushed Stone-powder (폐석분을 활용한 경량골재 콘크리트의 염화물 확산에 관한 연구)

  • Lee, Dae-Hyuk;Yoon, Sang-Chen;Jeong, Yong;Shin, Jae-Kyung;Jee, Nam-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.2
    • /
    • pp.255-262
    • /
    • 2010
  • The purpose of this study is to provide preliminary data on chloride diffusion of lightweight aggregate concrete containing crushed stone-powder. Accordingly, the study performed experiments using concrete aggregates of Crushed Aggregate (CG), Single-sized Lightweight Aggregate (SLG), Continuous Graded Lightweight Aggregate (CLG), and using water-binder ratio of 0.4, 0.5, 0.6, and using binder of FA and BFS. The chloride diffusion coefficient is calculated according to the NT BUILD 492. Diffusion coefficient of SLG and CLG were higher than that of CG concrete, but the difference was not significant. Also, chloride diffusion coefficient data indicated that it was highly affected by water-binder ratio, and it decreased with the decrease in waterbinder ratio. The admixture substitution of FA15% was effective in decreasing the diffusion coefficient only with water-binder ratio of 0.4 while admixture substitution of FA10+BFS20% was effective with all levels of water-binder ratio. The result of study shows lightweight aggregate concrete containing crushed stone-powder has slightly higher chloride diffusion coefficient than CG concrete, but the difference is not significant such that it can be overcome by adjusting water-binder ratio and admixture substitution. In addition, the data indicate the chloride diffusion coefficient of lightweight aggregate concrete can be estimated from the strength of lightweight aggregate.

Estimation on the Durability of Metakaolin Concrete According to the W/B Ratio (물결합재비를 달리하여 제작한 메타카올린 혼입 콘크리트의 내구성능 평가)

  • Kim, Chun-Ho;Kim, Nam-Wook
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.4
    • /
    • pp.84-91
    • /
    • 2014
  • In this study, in order to find the improvement effect of metakaolin for using improvement of strength in concrete structures, it is investigated the diffusion coefficient of chloride ions and adiabatic temperature rise test. As a result, due to the mixing of metakaolin, it has been confirmed reducing diffusion coefficient of chloride ions and could prevent down of slump for use of adding fly ash. Therefore, ensuring resistance to chloride ion penetration into concrete, it is possible to enlarge the W/B ratio and reduce the adiabatic temperature rise by mixing of metakaolin. So, it is confirmed that the durability of concrete structures is increased.

Spalling Properties of High Strength RC Column in accordance with Various W/B and Fiber Types (물결합재비 및 섬유종류 변화에 따른 고강도 모의 구조체의 폭렬특성)

  • Han, Cheon-Goo;Kim, Seoung-Soo;Kim, Sang-Shik;Jee, Suk-Won;Oh, Won-Young;Song, Yong-Won
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.11a
    • /
    • pp.83-86
    • /
    • 2007
  • This study provides the practical application of the concrete using fiber to protect from fire studied by previous research. The fluidity and air content is satisfied with the targets, and the compressive strength is over 60MPa on W/B 35% and 80MPa on W/B 20 and 25%. For the properties of the spalling after the fire test, there is no spalling or slight occurrence on the specimens. However, for the RC column, the covering concrete fall off caused by spalling occurrence. Based on the results, it is thought that the fiber content should be put into the safety factor to prevent spalling for the structures.

  • PDF

Fresh and Hardened Properties of Structural Lightweight Concrete according to the Physical Properties of Artificial Lightweight Aggregates (인공경량골재의 물리적 특성에 따른 구조용 경량콘크리트의 프레쉬 및 경화성상)

  • Shin, Jae-Kyung;Choi, Jin-Man;Jeong, Yong;Kim, Yang-Bea;Yoon, Sang-Chun;Jee, Nam-Yong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.377-380
    • /
    • 2008
  • Structural lightweight concrete will reduced total loads of supporting sections and foundations in archtectural and civil structures. So, the lightweight concrete can use widely for various purpose in the archtectural and civil structures. However, the performance of lightweight concrete is essentially dependent of properties of used lightweight aggregates. So, in this paper were examined the fresh and hardened properties of lightweight concrete that are used 3types of the differences properties of lightweight aggregates from lower water-ratio to higher water-ratio of concrete mixing regions. Lightweight concrete was somewhat exhibit larger slump loss than ordinary concrete. Also, the development of compressive strength was lower than ordinary concrete, however it was not showed a marked difference. According to types of lightweight aggregates, the case of synthetic lightweight aggregate are highest performance in fresh and hardened concrete, but it is should be to evaluate the structural performance testing as anchoring and bond strength with reinforcing steel bars.

  • PDF