• Title/Summary/Keyword: 무효전력

Search Result 641, Processing Time 0.027 seconds

A Knowledge Based System for Reactive Power/Voltage Control Including Contingency (상정사고를 고려한 무효전력/전압제어 전문가 시스템)

  • 박영문;김두현
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.8
    • /
    • pp.779-791
    • /
    • 1990
  • This paper presents a knowledge based system to solve reactive power/voltage control problem in a power system. A need is recognized for new methods to alleviate a bus voltage limit violation more quickly when a power system becomes an emergency state due to contingency. To cope with this object, a set of indices concept which is used to make bus order list of reactive power injection priority is introduced. A set of indices, based on the overall system conditions, consists of steady state stability index, reactive power transmittance indes, voltage severity index and generator fuel cost index. This scheme and empirical rules of the knowledge on the basis of the human expert result in fast decision-making of the reactive power compensation devices since only the amount of devices is determined by the inference in the knowledge based system when the voltage violation is detected. In this approach, control devices such as shunt capacitor (reactor), transformer tap settings and generator voltages are utilized. Also the developed system herein can be used to minimize control action taken or generator fuel cost according to the user's option on the weighting factor. The results of a case study are also presented.

  • PDF

A STUDY ON THE REACTIVE POWER COMPENSATION OF THREE PHASE UNBALANCED LOAD FOR VAR SYSTEM (VAR 시스템에 의한 3 상 불평형 부하의 무효전력 보상에 관한 연구)

  • Jung, Yon-Taek;Seo, Young-Soo;Kim, Young-Bong;Kim, Han-Soo;Lee, Bong-Joo
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.531-534
    • /
    • 1989
  • In this paper, the way that input voltage and input line current as a control variable is provided as one unit is projected. Till no, have denied with three phase balanced load. But, in that case, total power factor compensation is difficult, for to control each phase at unbalanced load. Therefor, in this paper suggest of the scheme that three phase unbalanced load is controlled by each phase and input total power factor is compensated unit input factor. therefore, in this paper suggest that three phase unbalanced load is controlled and the method in compensation of unit input factor to be attended by unbalanced load. Besides, the object of control is calculating quantity for input voltage and input line current for the point at issuse make to improve of control method at unbalanced load. As a result, control system of each phase could maintain as a unit input total power factor has been state diviation error of 2% with unbalanced load.

  • PDF

OPTIMAL REACTIVE POWER AND VOLTAGE CONTROL USING A NEW MATRIX DECOMPOSITION METHOD (새로운 행렬 분할법을 이용한 최적 무효전력/전압 제어)

  • Park, Young-Moon;Kim, Doo-Hyun;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.202-206
    • /
    • 1989
  • A new algorithm is suggested to solve the optimal reactive power control(optimal VAR control) problem. An efficient computer program based on the latest achievements in the sparse matrix/vector techniques has been developed for this purpose. The model minimizes the real power losses in the system. The constraints include the reactive power limits of the generators, limits on the bus voltages and the operating limits of control variables- the transformer tap positions, generator terminal voltages and switchable reactive power sources. The method developed herein employs linearized sensitivity relationships of power systems to establish both the objective function for minimizing the system losses and the system performance sensitivities relating dependent and control variables. The algorithm consists of two modules, i.e. the Q-V module for reactive power-voltage control, Load flow module for computational error adjustments. In particular, the acceleration factor technique is introduced to enhance the convergence property in Q-module, The combined use of the afore-mentioned two modules ensures more effective and efficient solutions for optimal reactive power dispatch problems. Results of the application of the method to the sample system and other worst-case system demonstrated that the algorithm suggested herein is compared favourably with conventional ones in terms of computation accuracy and convergence characteristics.

  • PDF

Comparative Simulation of flicker Mitigating Efficiencies of Various Compensating Devices using Matlab/Simulink (Matlab/Simulink를 이용한 무효전력 보상장치의 플리커 저감 효과 연구)

  • Jung, Jae-Ahn;Cho, Soo-Hwan;Jang, Gil-Soo;Kang, Moon-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.83-84
    • /
    • 2008
  • Voltage fluctuation, also known as flicker, is a power quality problem caused by nonlinear loads like electric arc furnace. Since it is interpreted as a variation of the supplied electrical energy, it causes the residential customers to feel much annoyed visually through the lamps. Due to the statistical nature of IEC (International Electrotechnical Commission) short-term flicker severity index, Pst, it is not feasible to pre-evaluate the flicker level using the transient power system simulators such as Sim Power System in Matlab/Simulink. So this paper presents not only how to design the Matlab/Simulink IEC flickermeter to yield the Pst value, which considering electric distribution environments of South Korea, but also how to mitigate the voltage flicker at the Point of Common Coupling (PCC). In order to achieve this, the flicker mitigation efficiencies of various compensating devices, such as Static Var Compensator (SVC), STATCOM will be applied and compared. The simulated result demonstrates which compensating equipment is the most efficient method to mitigate the flicker phenomenon.

  • PDF

F-V Analysis and STATCOM Installation Method to Replace Constrained Generation (F-V 해석을 이용한 수도권 제약발전 대체를 위한 STATCOM 투입 위치 선정 방안)

  • Noh, Hyeok-Jin;Oh, Seung-Chan;Park, Bohyun;Choi, Jin-San;Lee, Byong-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.163-164
    • /
    • 2015
  • LNG복합발전은 수요지 인근에 건설이 가능한 장점이 있어 수도권 인근 발전소 중 상당한 부분을 차지하고 있다. 이러한 LNG 복합발전은 수도권 부하비율 감소에 따라 발전량이 줄어들게 된다. 2018년 계통데이터를 기반으로 수도권의 부하수준이 70%까지 떨어졌을 때, 거의 모든 수도권 복합발전이 정지함을 확인할 수 있다. 이 때, 신가평과 강원을 잇는 765kV급 융통선로의 2회선 상정사고 발생 시 수도권 무효전력 공급원이 줄어들어 전압이 불안정해진다. 이와 같은 상정사고를 대비해 수도권 복합발전 중 일부는 제약운전을 시행해야 한다. 본 논문에서는 제약운전을 하는 수도권 LNG복합발전의 발전량을 대체할 수 있는 대안으로 적절한 위치에 FACTS설비를 투입하고자 한다. FACTS설비를 효율적으로 운전시키기 위해 LNG복합발전의 발전량 감소에 따른 전압변화에 대해 Tangent Vector Component가 가장 큰 수도권 345kV 모선을 선정해 STATCOM을 투입하고 그 결과를 확인한다. 이를 확인하기 위한 방안으로 제약운전을 하는 복합발전의 발전량을 감소시키고 관찰하고자 하는 모선과 거리가 먼 비수도권 발전량을 증가시켜 수급을 맞춘 뒤 전압의 변화를 관찰한다. 이 때, 하나의 계통을 2개의 지역으로 구역화하여 전압을 확인할 수 있는 F-V 해석을 이용한다.

  • PDF

Analysis for the Operating Characteristics when the Induction Motor is Used as a Generator (유도전동기를 발전기로 사용시 동작 특성 해석)

  • Kim, Jong-Gyeum
    • New & Renewable Energy
    • /
    • v.10 no.2
    • /
    • pp.5-11
    • /
    • 2014
  • Squirrel cage induction motor is the main driving system of industrial field and familiar with its use in a large variety of applications. The structure and operating characteristics of induction generator is almost identical to induction motor, but the induction generator part is used restrictively from hydropower power and wind power development etc. Recently induction generator is commonly used for micro & small hydro power applications due to its simplicity, reliability, low cost and robustness. Input and output of induction motor has turned against at the induction generator operation. Rotation speed of induction generator is small faster than synchronous speed of induction motor. As output of induction machines increases with the increasement of speed, so loss is same. Actually, generator efficiency is lower than motor at this condition. If induction generator is connected with mechanical load such as increaser, total efficiency is decreased. Consequently the quality in compliance with an induction motor parameter applying like that in the generator is a possibility of having the error of some. In this paper, we analyzed that input, output, torque and efficiency of induction machine is different from each other above and below synchronous speed.

A study for the system voltage and reactive power control (계통전압.무효전력 제어에 관한 연구)

  • 송길영
    • 전기의세계
    • /
    • v.14 no.3
    • /
    • pp.10-17
    • /
    • 1965
  • This paper presents a method of the voltage-reactive power control in the long and short range operations and introduces a conception, "optimum control pattern." The optimum control pattern, aiming at the over-all system control, is defined as the optimum voltage distribution which minimizes the system operating cost under the conditions that the specified power be supplied and the system voltage be kept within the specified bounds. The following procedure was adopted to obtain this optimum pattern. In the first place, a power system was divided into three blocks, namely, load, substation and generator. Lagrange's, multiplier method is applied to each block in turn, paying attention only at the operating voltage distribution. Phase angles at each bus are then modified so that the continuity of active power is maintained. This procedure may be called "block relaxation method with Lagrange's multipliers." In a long range operation, this control pattern determines the optimum installation capacity of reactive power sources. In a short range operation, it also gives the reference state of real time control and the optimum switching capacity of reactive power souces. The real time control problem is also studied from the standpoint of cooperation of control devices such as generators, shunt capacitors, shunt reactors and ratio load controllers. A proposal for the real time control will contribute to the automation of power system operation in the near future. in the near future.

  • PDF

Cooperation Algorithms of LTC and SC for Distribution Volt/Var Regulation (배전계통 전압/무효전력 보상을 위한 LTC변압기와 SC의 협조운전 알고리즘)

  • Choi, Joon-Ho;Kim, Jae-Chul;Nam, Hae-Kon;Moon, Seung-Il
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.399-402
    • /
    • 2003
  • In this paper, the on line volt/var control algorithms of the food Load Tap Changer (LTC) transformer and Shunt Capacitor(SC) are proposed for distribution volt/var regulation. In the existing volt/var control of the distribution substation, the voltage of feeders and var of distribution systems is mainly controlled by the LTC transformer tap position and on/off status of the shunt capacitor. The LTC and shunt capacitor bank has discrete operation characteristics and therefore it is very difficult to control volt/var at the distribution networks within the satisfactory levels. Also there is limitation of the operation times of the LTC and shunt capacitor bank because it is affects on their functional lifetime. The proposed volt/var control algorithm determine an optimal tap position of LTC and on/off status of shunt capacitors at a distribution network with the multiple feeders. The mathematical equations of the proposed method are introduced. Simple case study was performed to verify the effectiveness of the proposed method.

  • PDF

The Optimal Volt/Var Control Algorithm with Distributed Generation of Distribution System (분산전원이 연계된 배전계통의 최적 전압/무효전력 제어 알고리즘)

  • Kim, Young-In;Lim, Il-Hyung;Choi, Myeon-Song;Lee, Seung-Jae;Lee, Sung-Woo;Ha, Bok-Nam
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.2
    • /
    • pp.298-305
    • /
    • 2010
  • In this paper, a new algorithm of optimal Volt/Var Control is proposed using Volt/Var control for the Distribution Automation System (DAS) with Distributed Generation (DG) based on the modeling of the distributed load and the distributed current. In the proposed, algorithm based on the modeling of the distributed load and the distributed current are estimated from constants of four terminals using the measurement of the current and power factor from a Feeder Remote Terminal Unit (FRTU) and DG data from RTU for DG. For the optimal Volt/Var Control, the gradient method is applied to find optimal solution for tap, capacity and power control of OLTC (On-Load Tap Changers), SVR (Step Voltage Regulator), PC (Power Condenser) and DG (Distributed Generation). In the case studies, the estimation and control of the voltages have been testified in a radial distribution system with DG using matlab program.

A Study on a Methodology of Determining an Appropriate Load Power Factor Effectively by the Use of Reactive Power Sensitivity and Load Duration Curve (무효전력 민감도와 부하지속곡선을 활용한 적정 부하역률의 효과적인 산정 기법에 관한 연구)

  • Lee, Byung Ha;Hwang, Sung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.12
    • /
    • pp.1782-1790
    • /
    • 2012
  • In this paper, a methodology to use load duration curve and the reactive power factor sensitivity of generation cost is proposed for analyzing the effects of load power factor effectively. A great deal of cases of power systems are classified into several patterns according to the characteristics using load duration curve, and the overall effects of load power factor are assessed by integrating the analysis results of load power factor in all the patterns. The reactive power sensitivity of generation cost and the integrated costs such as generation cost, investment cost, voltage variation penalty cost and CO2 emission cost are used for determining an appropriate load power factor. A systematic procedure for effective analysis of load power factor is presented. It is shown through the application to the practical power system of KEPCO(Korea Electric Power Corporation)that the effects of load power factor can be analyzed effectively using load duration curve and reactive power factor sensitivity.