• Title/Summary/Keyword: 무효전력

Search Result 641, Processing Time 0.03 seconds

Optimal Control of Voltage and Reactive Power in Local Area Using Genetic Algorithm (유전알고리즘을 이용한 지역계통의 전압 및 무효전력 최적제어)

  • 김종율;김학만;남기영
    • Journal of Energy Engineering
    • /
    • v.12 no.1
    • /
    • pp.42-48
    • /
    • 2003
  • In system planing and operation, voltage and reactive power control is very important. The voltage deviation and system losses can be reduced through control of reactive power sources. In general, there are several different reactive power sources, we used switched shunt capacitor to improve the voltage profile and to reduce system losses. Since there are many switched shunt capacitors in power system, so it if necessary to coordinate these switched shunt capacitors. In this study, Genetic Algorithm (GA) is used to find optimal coordination of switched shunt capacitors in a local area of power system. In case study, the effectiveness of the proposed method is demonstrated in KEPCO's power system. The simulation is performed by PSS/E and the results of simulation are compared with sensitivity method.

Reduction of PCC Voltage Variation using Reactive Power Control of Grid Connected Wind Turbine (풍력발전기의 계통연계 시 무효전력 제어를 통한 PCC 전압변동 저감)

  • Im, Ji-Hoon;Song, Seung-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2009.11a
    • /
    • pp.203-205
    • /
    • 2009
  • 풍력발전기가 계통에 연계되어 유효전력이 출력되면 PCC의 전압이 변동하며, 이러한 전압변동은 풍력발전기 출력에 비례한다. 전압변동의 발생요인은 전원에서 PCC지점까지의 선로 등가 임피던스의 크기와 풍력발전기 출력 전류의 곱의 형태로 표현 된다. 이러한 전압변동은 무효전력의 공급으로 억제할 수 있으며 필요로 하는 무효전력량은 풍력발전기 출력량에 비례한다. 이를 검증하는 방안으로 삽시도의 계통을 바탕으로 PSCAD/EMTDC 시뮬레이션과 실측데이터를 활용하였다.

  • PDF

Stabilization of High-Voltage Static Var Compensator Using Switching Velocity and Temperature Control (스위칭 속도 및 온도 제어를 사용한 고압용 정지형 무효전력 보상장치의 안정화)

  • Kim, Yong-Tae;Lee, Chang-Seok
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.23 no.2
    • /
    • pp.107-112
    • /
    • 2013
  • In the paper, velocity controller of switching module and temperature controller for the high-voltage static var compensator are proposed. Because of the continuous increase in demand for electric power, transmission and distribution facilities of power plant are required. There is a bottleneck problem of transportation routes according to new construction and expansion of power transmission facilities. Therefore there are researches to maximize the utilization of existing facilities and to increase transmission capacity without new construction. The previous static var compensator detects voltage of input circuit of power, switches the SCR directly and generates switching noise. The proposed method increases switching velocity and decreases noise using switching control based on the voltage between both sides of SCR. Also the proposed method enhance the stability using realtime temperature control for heating of the system from increase of switching velocity. We experiment the velocity and temperature control of the proposed high-voltage static var compensator in the real environment and verify the performance of the proposed system by applying in the real field.

A Study on Analysis and Application of Power Factor (부하역율 분석 및 적용에 관한 연구)

  • Kim, Tae-Ok;Chang, Jae-Won;Kwon, Tae-Won
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.41-43
    • /
    • 2002
  • 전력계통 해석의 정밀도 향상을 위해서는 배전용변압기 1차측 기준의 정확한 부하역율 데이터 입력이 요구되나, 현재 역율산정을 위한 유 무효전력 측정설비가 변압기 2차측에만 설치되어 변압기 자체에서 소모되는 무효전력에 대한 보다 정확한 고려방법 모색이 필요하다. 이와 관련하여 본 고에서는 변압기 OLTC 변화에 따른 소모 무효전력 변화량 고려방법, 변압기 2차측 유, 무효전력 측정치 및 조상설비 운전실적 등 제반 요소를 고려한 변압기 1차측 기준의 역율 산정방법을 제시하고, 현재 우리계통에서 운전되고 있는 154kV 전 변전소 전 변압기 및 154kV 직거래고객에 대하여 계절별, 요일별, 시간대별로 총 44개 케이스의 부하역율 특성분석 결과를 이용 계통해석시 적용되는 부하데이터의 정밀도 향상방안과 부하역율 변경 적용시 계통해석 결과에 미치는 영향 등에 대한 우리나라 실 계통 대상 모의 결과를 다루었다.

  • PDF

The present state of reactive technology research and importance (무효전력 기술연구 현황 및 중요성)

  • Won, Yun-Ah;Kim, Nam-Kyung;Cha, Jun-Min
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2261_2262
    • /
    • 2009
  • 에너지 손실 절감과 효과적인 에너지 사용 및 안정적인 전력계통 운영을 위한 전력계통 운용 전략을 알아보았다. 그리고 선진국의 무효전력운영 현황과 국내 계통운영 보조서비스정책의 비교를 통해 우리 나라의 경우는 단일 계통으로 구성되어 있기 때문에, 미국의 경우에 비하여 무효전력 종합 관리 시스템의 구축 및 운영을 보다 쉽게 구현할 수 있을 것으로 생각된다. 미국의 경우와 같이 지속적이며 실질적인 시험과 분석을 통하여 체계적이며 정기적인 무효전력 제어 및 감시체제가 구축되어야 할 것으로 판단된다.

  • PDF

Realtime Compensation of PCC Voltage Variation by Injection of Required Reactive Power in a Grid Connected Variable Speed Wind Turbine (계통 연계형 가변속 풍력발전기의 무효전력 주입을 통한 PCC 전압 변동량 실시간 보상)

  • Im, Ji-Hoon;Song, Seung-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.69-74
    • /
    • 2010
  • In a grid connected variable speed wind turbine, the PCC voltage and the wind power fluctuate as the wind velocity changed. And this voltage variation is changed due to location of PCC. This paper calculate the value of PCC voltage variation which is proportional to the product of the line impedance from the ideal generator to the PCC and the wind turbine output current. And to reduce this PCC voltage variation, this paper calculate the required reactive power analytically using the vector diagram method. Output reactive current is changed, if the reactive current is limited by inverter capacity or grid code have the margin of voltage variation. If the grid connected inverter is controlled by proposed algorithm, the PCC voltage variation is minimized though the wind turbine output change at random. To verify calculated voltage variation and required reactive power, this paper utilized Matlab and PSCAD/EMTDC simulation and real small wind turbine and power system in Sapsido, island in the Yellow Sea.

Reactive Power Control using Single Phase Grid-Connected PV Power System (단상 계통 연계형 태양광 발전을 이용한 무효전력 제어)

  • Kim, Seung-Tak;Kang, Byung-Kwan;Park, Jung-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.509_510
    • /
    • 2009
  • 태양광 발전 시스템은 그 특성에 따라 주로 주택, 빌딩 등 비선형 부하를 지니는 장소에 단상 계통으로 연결되는 경우가 많다. 계통 연계형 태양광 발전 시스템 설치가 증가함에 따라 태양광 발전 시스템의 무효전력 제어는 전력품질 향상에 대해 의미를 지니게 된다. 본 논문은 3kW급 단상 계통 연계형 태양광 발전 시스템에 대해 간편한 무효 전력 제어 방식을 보여준다.

  • PDF

Preliminary Design of AC/DC Converter Control System for ITER Superconducting Magnet (ITER 초전도자석 전원공급장치 제어시스템의 예비설계)

  • Suh, J.H.;Oh, J.S.;Choi, J.;Hwang, K.C.;Kang, J.B.;Lee, W.S.;Seo, E.;Kim, H.G.;kim, M.K.
    • Proceedings of the KIPE Conference
    • /
    • 2012.11a
    • /
    • pp.251-252
    • /
    • 2012
  • ITER(국제핵융합실험로) 제어시스템은 중앙제어와 Plant System으로 구성되며 CODAC, Central Interlock, Central Safety System으로 구분된다. 초전도자석에 전류를 공급하는 AC/DC 컨버터 시스템은 2상한, 4상한 구조의 전원 장치, 초기 플라즈마 발생에 필요한 Switching Network Unit, 코일에 저장된 에너지의 급속 방전을 위한 Fast Discharge Unit 및 무효 전력 보상장치로 구성된다. 4상한 전원장치는 1, 2, 4, 6대의 전원 장치가 직렬 접속되어 무효전력 발생이 최소로 하도록 제어된다. 대용량의 무효전력이 급격히 변화는 환경에서 계통 전압을 유지하기위해 무효전력보상장치는 각 전원 장치가 예측한 무효전력 값을 이용하여 제어한다. 본 논문은 ITER 전원 장치를 운전하기 위한 제어시스템의 개요와 예비설계 결과이다.

  • PDF

A Reactive Power Compensation Monitoring System for Factory Electrical Installation Using Active Database (능동 데이터베이스 기반 무효전력 보상장치 감시제어 시스템)

  • Choi, Sang-Yule
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.4
    • /
    • pp.189-194
    • /
    • 2012
  • The main purpose of reactive power compensation monitoring system is to manage factory electrical installation efficiently by On-Off switching reactive power compensation equipment. The existing reactive power compensation monitoring system is only able to be managed by operator whenever electrical installation needed reactive power. Therefore, it may be possible for propagating the installation's faults when operator make the unexpected mistakes. To overcome the unexpected mistakes, in this paper, the author presents a reactive power compensation monitoring system for factory electrical installation using active database. by using active database production rule, stated system can minimize unexpected mistake and can operate centralized monitoring system efficiently. Test results on the five factory electrical installations show that performance is efficient and robust.

A Study on Evaluation of Reactive Power Reserve Considering Connection of Large Scale Wind Farm in Jeju System (제주계통 대규모 풍력발전단지 연계에 따른 무효전력 예비력 산정에 관한 연구)

  • Kim, Do-Hyuk;Lee, Hwan-Ik;Shin, Hee-Won;Lee, Byong-Jun;Lee, Chang-Gun;Kang, Yong-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.167-168
    • /
    • 2015
  • 신재생 에너지에 대한 관심이 계속 증가하고 있고, 국가적으로도 신재생 에너지의 비율을 점차 늘려나가는 것을 목표로 하고 있다. 특히 풍력발전은 컨버터를 이용한 대규모 계통접속이 가능하여 유럽을 중심으로 빠르게 발전하고 있다. 국내에서는 제주 지역이 상대적으로 양호한 바람의 조건으로 풍력발전의 비중을 늘릴 수 있는 최적의 장소이다. 하지만 대규모 풍력발전단지의 계통연계 시 무효전력의 변화에 따른 전압불안정이 발생할 수 있다. 따라서 본 논문에서는 제주지역의 대규모 풍력발전단지 계통연계 시, 무효전력의 변화를 관찰한다. 또한 대규모 풍력발전의 계통연계에 따른 전압안정을 위해 무효전력 예비력을 산정한다.

  • PDF