• 제목/요약/키워드: 무효전력보상기

검색결과 24건 처리시간 0.019초

멀티레벨 직렬 전압형 인버터를 이용한 무효전력보상기(SVC)의 제어 (Control of Static Var Compensator Using A Cascade Typed Multilevel Voltage Source Inverter)

  • 민완기;박용배;김영한;최재호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.332-335
    • /
    • 1996
  • Multilevel voltage source inverters are emerging as a new breed of power inverter options for high power applications. This paper presents a cascade typed multilevel voltage source inverter which has separate de sources for high voltage. This inverter is proposed for flexible ac transmission systems (FACTS) including static var compensator(SVC), series compensation and phase shifting. It can solve the problems of conventional transformer-based multipulse inverters and the problems of multilevel diode-clamped inverters. To show the superiority of multilevel cascaded inverter, simulation results are discussed in detail.

  • PDF

전력계통의 미소신호안정도에 미치는 제어기의 영향에 관한 연구 (A Study on the Effect of Controllers in Small Signal Stability of Power Systems)

  • 권세혁;김덕영
    • 에너지공학
    • /
    • 제5권1호
    • /
    • pp.72-79
    • /
    • 1996
  • 본 논문은 전력계통의 안정도에 미치는 제어장치들의 영향과 안정도 개선에 대해 연구하였다. 제어장치로는 여자기와 전력계통안정기(PSS) 그리고 무효전력보상기(SVC)를 일기무한모선계통에 설치하고, 이때의 상태행렬의 구조를 제시하였다. 상태행렬의 구조식과 고유치, 고유벡터로부터 제동이 불량한 고유치에 대한 감도계수를 구하여 각 제어기별로 중요진동모드에 대한 영향을 수치적으로 나타내었다. 또한 계통의 운용조건을 달리하여 계통변화에 따라 제어장치들이 안정도에 미치는 영향을 관찰하였다. 계통의 안정도를 개선시키기 위해서 제어기정수의 일차고유치감도계수를 선형계획법인 심플렉스법에 적용하여 제어기정수의 최적화를 수행하였다 이때 일차고유치감도계수만으로 최적화를 하는데 따른 문제점을 해결하기 위해 각 제어기정수의 변화폭을 좁게 설정하고, 각 반복계산마다 전단계에서 구한 최적 정수값을 제어기정수의 변화범위를 달리하여 다시 최적화하는 방법을 사용하였다.

  • PDF

단일 인버터 기반 에어컨용 실외기 팬 모터 병렬운전에서의 무효전력보상기를 이용한 맥동저감 기법 (The Vibration Suppression using Reactive Power Compensator for Speed Control of Parallel Connected Dual Fan Motors fed by a Single Inverter)

  • 윤철;권우현;조내수
    • 전기학회논문지
    • /
    • 제65권12호
    • /
    • pp.2008-2013
    • /
    • 2016
  • This paper proposes analysis and suppression method for reactive power vibration of the slave motor caused by back-EMF mismatch between the master and the slave motor and stator resistance during middle-low speed operation. The master and slave motors are parallel connected dual SPMSMs(Surface mounted Permanent Magnet Synchronous Motors) fed by a single inverter. To suppress vibration of reactive power, RPC(Reactive Power Compensator) proposed in this paper analyzes flux-axis current vibration of the slave motor that occurs in middle-low speed operation using a mathematical model of the fan motor. And RPC adds vibration components detected from flux-axis current of the slave motor to flux-axis current of the master motor. The results of experiment conducted verify the efficacy of the proposed method.

스위치의 선형영역을 이용한 무효전력보상기의 돌입전류 억제 방안 (Inrush Current Suppression Method of the Reactive Power Compensator by using a Linear Region of the Switch)

  • 박성미;강성현;박성준
    • 조명전기설비학회논문지
    • /
    • 제27권3호
    • /
    • pp.55-64
    • /
    • 2013
  • In this paper, a new topology which can add a small reactor in series to a condenser-bank type reactive power compensator to limit current is proposed. And also the proposed topology can add or remove a power condenser safely without any addition of inrush-current suppression resistance. The proposed method tests variable resistance of the drain source of a switching device which is controlled by gate voltage in a two-way switch with a diode rectifier and FET switch. In other words, the proposed method is a inrush-current suppression method with the structure of variable resistance. In particular, the proposed method creates smooth current without any resonance in inrush-current as well as is not limited by the time of switch on and off.