무전극 형광램프용 안테나 설계를 위한 전기적 특성 시뮬레이션 (Electrical Characteristics of Antenna for Electrodeless Fluorescent Lamp Using the Electromagnetic Simulation)

  • 허인성;김광수;최용성;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 방전 플라즈마 유기절연재료 초전도 자성체연구회
    • /
    • pp.61-64
    • /
    • 2004
  • Recently, the RF inductive discharge or inductively coupled plasma (ICP) continues to attract growing attention as an effective plasma source in many industrial applications, the best known of which are plasma processing and lighting technology. To the point of lighting sources, the electrodeless fluorescent lamps utilizing an inductively coupled plasma (ICP) have been objects of interest and research during the last decades, mainly because of their potential for extremely long life, high lamp efficacies, rapid power switching response. The electrodeless fluorescent lamp that is dealt with in this work comprises a bulb filled with rare gas and amalgam of vaporizable metal and has a coil provided with a winding around the ferrite. Current through a coil produces a magnetic field in the discharge space. The changing magnetic flux then produces an azimuthal electric field E around the coil, according to Faraday's laws of magnetic induction.

  • PDF

둥근형 무전극 형광램프의 자계 분포 특성 (Magnetic Field Distribution Characteristics of Ring-Shaped Electrodeless Fluorescent Lamp)

  • 최용성;조재철;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 광주전남지부
    • /
    • pp.53-57
    • /
    • 2006
  • In this paper, maxwell 3D finite element analysis program (Ansoft) was used to obtain electromagnetic properties associated with the coil and nearby structures. The electromagnetic emitting properties were presented by 3D simulation software operated at 250 kHz and some specific conditions. The electromagnetic field in the ferrite core was shown to be high and symmetric. An LS-100 luminance meter and a Darsa-2000 spectrum analyzer were used in the experiment. According to data on the lamp tested using high magnetic field ferrite, the optical and thermal wave fields were shown to be high around the ring-shaped electrodeless fluorescent lamp. The optical or light field was high at the center of the bulb rather than around the ferrite core. The light conditions of the bulb were assumed to be complex, depending on the condition of the filler gas, the volume of the bulb, and the frequency of the inverter. Our results have shown coupling between the gas plasma and the field of the light emitted to be nonlinear.

  • PDF

무전극 형광램프용 안테나 설계를 위한 전기적 특성 시뮬레이션 (Electrical Characteristics of Antenna for Electrodeless Fluorescent Lamp Using the Electromagnetic Simulation)

  • 허인성;김광수;최용성;이종찬;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.285-288
    • /
    • 2004
  • Recently, the RF inductive discharge or inductively coupled plasma(ICP) continues to attract growing attention as an effective plasma source in many industrial applications, the best known of which are plasma processing and lighting technology. To the point of lighting sources, the electrodeless fluorescent lamps utilizing an inductively coupled plasma(ICP) have been objects of interest and research during the last decades, mainly because of their potential for extremely long life, high lamp efficacies, rapid power switching response. The electrodeless fluorescent lamp that is dealt with in this work comprises a bulb filled with rare gas and amalgam of vaporizable metal and has a coil provided with a winding around the ferrite. Current through a coil produces a magnetic field in the discharge space The changing magnetic flux then produces an azimuthal electric field E around the coil, according to Faraday's laws of magnetic induction.

  • PDF

무전극 램프 안테나의 권선수에 따른 휘도와 파라미터 특성 (Parameter and Brightness Characteristic of Antena according to Coil turns on Electrodeless Fluorescent Lamp)

  • 양종경;최기승;백광현;최용성;이종찬;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.281-284
    • /
    • 2004
  • In Recent, it became necessary to envelope the technology about electrodeless fluorescent lamp according to demand of the electrodeless fluorescent lamp system that used higher efficiency and advantage of long-lifetime. Especially, in the electrodeless fluorescent lamp which used H-mode, efficiency of lamp is decided from matching parameter of antena and inverter So it is of the utmost importance to design antena and inverter. Therefore, this paper used a transformer principle for efficiency rising of electrodeless fluorescent lamp and interpreted an equivalent circuit, used an impedance analyzer in order to confirm a performance enhancement of lamp along design of antenna, and confirmed parameter characteristic of R, L, C, Z, Phase, Q-factor along a change of magnetic flux density. Also, this paper confirmed a luminance characteristic of electrodeless lamp along parameter change with measuring optical characteristic along a change of magnetic flux density.

  • PDF

무전극 램프의 안테나 파라미터 변화에 따른 휘도특성 (Brightness Characteristic as a Change of Antena Parameter on Electrodeless Fluorescent Lamp)

  • 양종경;최기승;백광현;최용성;이종찬;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.164-166
    • /
    • 2004
  • In Recent, it became necessary to develope the technology about electrodeless fluorescent lamp according to demand of the electodeless fluorescent lamp system that used higher efficiency and advantage of long-lifetime. Especially, in the electordeless fluorescent lamp which used H-mode, efficiency of lamp is decided from matching parameter of antena and inverter, so it is of the utmost importance to design antena and inverter. Therefore, this paper used a transformer principle for an efficiency rising of electrodeless fluorescent lamp and interpreted an equivalent circuit, and confirmed a luminance characteristic by ferrite change of antenna and change of coil turns. Also, this paper used the thermoelectric element which can let you cool ferrite and antenna and confirmed the luminance characteristic along a change of ferrite and an antenna temperature.

  • PDF

2.5MHz급 무전극 램프 구동용 ZVS 인버터에 관한 연구 (2.5MHz Zero-Voltage-Switching Resonant Inverter for Electrodeless Fluorescent Lamp)

  • 박동현;김희준;조기연;계문호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.339-342
    • /
    • 1996
  • Driving the electrodeless fluorescent lamp, the high ac voltage with high frequency is required. The linear power amplifier has been widely used as a driving circuit of electrodeless fluorescent lamp. However, the low efficiency of the power amplifier causes the driving circuit to be replaced by a PWM switching inverter. In order to use a PWM switching inverter as the driving circuit of an electrodeless fluorescent lamp, the high switching frequency is required. But due to the switching loss at switches of the inverter, the limitation of high switching frequency appears in the inverter. One solution to this limitation is to reduce the switching loss by using the zero voltage switching technique. In this paper, zero voltage switching resonant inverter for driving an electrodeless fluorescent lamp is discussed. The results of analysis about the inverter are presented and the equations for design are established. And the validity of the analyzed results are verified through the experiment.

  • PDF

환형 무전극 형광램프의 전자계특성 (Electromagnetic Properties of Ring-Shaped Electrodeless Fluorescent Lamps)

  • 조주웅;이성진;최용성;김용갑;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.521-524
    • /
    • 2003
  • In recent, there have been several developments in lamp technology that promise savings in electrical power consumption and improved quality of the lighting space. Above all, the advantage of ring-shaped electrodeless fluorescent lamp is the removal of internal electrodes and heating filaments that are a light-limiting factor of conventional fluorescent lamps. The ring-shaped electrodeless lamp is intended as a high efficacy replacement for the incandescent reflector lamp in many applications. Therefore, the life time of ring-shaped electrodeless fluorescent lamps is substantially higher than that of conventional fluorescent lamps and last up to 60,000 hours. In this paper, maxwell 3D finite element analysis program (Ansoft) was used to obtain electromagnetic properties associated with the coil and nearby structures. The electromagnetic emitting properties were presented by 3D simulation software operated at 250kHz and some specific conditions.

  • PDF

환형 무전극 형광램프의 최적 설계를 위한 특성조건 분석 (A study on Properties Condition for the most suitable design of the Ring-shaped electrodeless fluorescent lamp)

  • 조주웅;이성진;남중희;최용성;김용갑;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.1
    • /
    • pp.211-214
    • /
    • 2004
  • The advantage of ring-shaped electrodeless fluorescent lamp is the removal of internal electrodes and heating filaments that are a light-limiting factor of conventional fluorescent lamps. Therefore, the life time of ring-shaped electrodeless fluorescent lamps is substantially higher than that of conventional fluorescent lamps and last up to 60,000 hours and is intended as a high efficacy replacement for the incandescent reflector lamp in many applications. In this paper, maxwell 3D finite element analysis program(Ansoft) was used to obtain electromagnetic properties associated with the coil and nearby structures. The electromagnetic emitting properties were presented by 3D simulation software operated at 250[kHz] and some specific conditions

  • PDF

무전극 램프의 효율향상을 위한 안테나의 파라미타 특성 및 휘도특성 (Parameter and Brightness Characteristic Analysis of Antena for Efficiency Improvement on Electrodeless Fluorescent Lamp)

  • 양종경;최기승;백광현;최용성;이종찬;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 추계학술대회 논문집 Vol.17
    • /
    • pp.531-534
    • /
    • 2004
  • In Recent, it became necessary to develope the technology about electrodeless fluorescent lamp according to demand of the electodeless fluorescent lamp system that used higher efficiency and advantage of long-lifetime. Especially, in the electordeless fluorescent lamp which used H-mode, efficiency of lamp is decided from matching parameter of antena and inverter. So it is of the utmost importance to design antena and inverter Therefore, this paper used a transformer principle for efficiency rising of electrodeless fluorescent lamp and interpreted an equivalent circuit, used an impedance analyzer in order to confirm a performance enhancement of lamp along design of antenna, and confirmed parameter characteristic of R, L, C, Z, Q-factor along a change of magnetic flux density. Also, this paper confirmed a luminance characteristic of electordeless lamp along parameter change with measuring optical characteristic along a change of magnetic flux density

  • PDF

환형 무전극 형광램프의 전자계 시뮬레이션, 전기적 및 광학적 특성 (Electromagnetic Simulation of Ring-shaped Electrodeless fluorescent Lamps and its Electrical and Optical Characteristics)

  • 최용성;조주웅;이영환;김광수;박대희
    • 한국전기전자재료학회논문지
    • /
    • 제17권5호
    • /
    • pp.552-559
    • /
    • 2004
  • In recent, there have been several developments in lamp technology that promise savings in electrical power consumption and improved quality of the lighting space. Above all, the advantage of ring-shaped electrodeless fluorescent lamp is the removal of internal electrodes and heating filaments that are a light-limiting factor of conventional fluorescent lamps. The ring-shaped electrodeless lamp is intended as a high efficiency replacement for the incandescent reflector lamp in many applications. Therefore, the life time of ring-shaped electrodeless fluorescent lamps is substantially higher than that of conventional fluorescent lamps and last up to 60,000 hours. In this paper, maxwell 3D finite element analysis program(Ansoft) was used to obtain electromagnetic properties associated with the coil and nearby structures. The electromagnetic emitting properties were presented by 3D simulation software operated at 250 KHz and some specific conditions. The optical characteristics were measured luminance and a temperature and an optical spectrum distribution for 10 min in a one minute interval at the same time. With a goal of finding alternative materials, we show measurement results of electrical characteristics of a ring-shaped electrodeless fluorescent lamp as a function of frequency and the number of coil turns using a highly permeable($\mu$$_{r}$(equation omitted) 2,000) Mn-Zn ferrite. These results are compared with those of conventional ring-shaped electrodeless fluorescent lamp. It is found that the resistance, inductance and impedance are increased while the quality factor decreases as frequency increases.s.