• Title/Summary/Keyword: 몬테칼로 모사

Search Result 78, Processing Time 0.031 seconds

Monte Carlo simulation for the transport of ion in matter (물질내의 이온수송에 대한 Monte Carlo 전산모사)

    • Journal of the Korean Vacuum Society
    • /
    • v.5 no.4
    • /
    • pp.292-300
    • /
    • 1996
  • The scattering of incident ions and target atoms in the amorphous solid matters are calculated by Monte Carlo simulation method. The experimentally derived universal scattering cross-section of Kalbitzer and Oetzmann is used to describe nuclear scattering. For electronic energy loss, the Lindhard-Scharff and Bethe formula are used. Comparing the ion scattering formulas and ranges with the known results of experiment and other programs, we find our results are good agreement with others.

  • PDF

Characterization Study of Detector Module with Crystal Array for Small Animal PET: Monte Carlo Simulation (소동물 전용 양전자방출단층시스템의 섬광체 배열에 따른 특성 평가: 몬테칼로 시뮬레이션 연구)

  • Baek, Cheol-Ha
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.4
    • /
    • pp.350-356
    • /
    • 2015
  • The aim of this study is to perform simulations to design the detector module with crystal array by Monte Carlo simulation. For this purpose, a small animal PET scanner, employing module with 1~8 crystal array discrimination scheme, was designed. The proposed scanner has an inner diameter of 100 mm with detector modules in crystal array. Each module is composed of a 5.0 mm LSO crystal with a $2.0{\times}2.0mm^2$ sensitive area with a pitch 2.1 mm and 10.0 mm thickness. The LSO crystals are attached to the SiPM which has a dimension of $2.0{\times}2.0mm^2$. The detector module with crystal array of the designed PET detector was simulated using the Monte Carlo code GATE(Geant4 Application for Tomographic Emission). The detector is enough compensation for the loss of data in sinogram due to gaps between modules. The results showed that the high sensitivity and effectively reduced the problem about the missing data were greatly improved by using the detector module with 1 crystal array.

A Study on the Shielding of Iodine 131 Using Monte Carlo Simulation (몬테칼로 모사를 이용한 방사성옥소 I-131의 차폐체에 대한 효용성 연구)

  • Jang, Dong-Gun;Yang, Seoung-Oh;Kim, Jung-Ki;Lee, Sang-Ho;Choi, Hyung-Seok;Bae, Cheol-Woo
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.143-150
    • /
    • 2014
  • This study was designated to investigate the bremsstrahlung and radiation dose by beta rays. Radiation attenuation from I-131 treatment ward was analyzed using radio protective apron. Shielding materials which is included lead or water were simulated in Monte Carlo Simulation then the spectrum on interaction was analyzed. The shielding materials were categorized according to the thickness. 0.25mm and 0.5mm thick lead and 0.1mm and 0.2mm thick water shielding materials were configured in Monte Carlo Simulation for this study. Only lead shielding method and water plus lead shielding method were carried. As a results, when 0.5mm thick lead shielding method was performed, the radiation dose was similar to the results with water plus lead shielding method. In case of using 0.25mm thick lead shielding, the shielding effect was somewhat less. However, that shielding method cause dose reduction of about 60% compare with non-shielding material.

Application of Variance Reduction Techniques for the Improvement of Monte Carlo Dose Calculation Efficiency (분산 감소 기법에 의한 몬테칼로 선량 계산 효율 평가)

  • Park, Chang-Hyun;Park, Sung-Yong;Park, Dal
    • Progress in Medical Physics
    • /
    • v.14 no.4
    • /
    • pp.240-248
    • /
    • 2003
  • The Monte Carlo calculation is the most accurate means of predicting radiation dose, but its accuracy is accompanied by an increase in the amount of time required to produce a statistically meaningful dose distribution. In this study, the effects on calculation time by introducing variance reduction techniques and increasing computing power, respectively, in the Monte Carlo dose calculation for a 6 MV photon beam from the Varian 600 C/D were estimated when maintaining accuracy of the Monte Carlo calculation results. The EGSnrc­based BEAMnrc code was used to simulate the beam and the EGSnrc­based DOSXYZnrc code to calculate dose distributions. Variance reduction techniques in the codes were used to describe reduced­physics, and a computer cluster consisting of ten PCs was built to execute parallel computing. As a result, time was more reduced by the use of variance reduction techniques than that by the increase of computing power. Because the use of the Monte Carlo dose calculation in clinical practice is yet limited by reducing the computational time only through improvements in computing power, introduction of reduced­physics into the Monte Carlo calculation is inevitable at this point. Therefore, a more active investigation of existing or new reduced­physics approaches is required.

  • PDF

몬테칼로모사를 이용한 영광 3.4 호기 원자로 압력용기에 대한 중성자조사량 계산

  • 김종오;김종경
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05a
    • /
    • pp.905-910
    • /
    • 1995
  • 영광 3·4호기 원자로 압력용기에 대한 고속중성자 조사량을 계산하기 위하여 MCNP코드로 3차원 모델링을 하였다. 중성자선원은 출력분포에 의해 핵연료집합제 단위로 하였고 원자로심부터 원자로 압력용기 밖까지 핵분열 반응을 포함한 모든 반응에 대해 중성자를 수송시켰다. 원자로 압력용기 안쪽 면에서의 고속중성자 플루언스는 기존의 연구자와 비교할 때 큰 차이가 있었다. 그러나 이번 연구의 계산방법이 보다 신뢰할 수 있기 때문에 앞으로의 연구를 통하여 기존의 연구방법과 비교하는 것이 필요하다.

  • PDF

A Study on Non-proportionality of Phoswich Detector Using Monte Carlo Simulation (몬테칼로 전산모사를 이용한 Phoswich 계측기의 비선형성 연구)

  • Kim, Jae-Cheon;Kim, Jong-Kyung;Kim, Soon-Young;Kim, Yong-Kyun;Lee, Woo-Gyo
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.4
    • /
    • pp.263-268
    • /
    • 2004
  • Using the Monte Carlo simulation, a study on the lion-proportionality of the prototype phoswich detector with $2'{\times}2'$ CSI(Tl) and plastic scintillator, which was made by KAERI, has been carried. The defector response functions (DRFs) calculated by simulations were compared with the experimental measurement on the $^{137}Cs\;and\;^{60}Co$. To precisely simulate the DRF for the phoswich, the CSI(Tl) non-proportionality was calculated using the electron response and the simplified electron cascade sequence for treating the photoelectric absorption event. The resulting DRFs of $^{137}Cs\;and\;^{60}Co$ sources obtained by simulations were compared with experiments for verification. For $^{137}Cs$, gamma-ray responses simulated by MCNP5 are generally good agreement with the measured ones. But the DRF of $^{60}Co$ does not match well with the results of experiment in the energy region below second peak due to the coincidence effect of two gamma-rays (1.17 MeV and 1.33 MeV). Through the analysis of the non-proportionality of CsI(Tl) in the prototype phoswich, the improved DRFs considering non-proportionality were produced and the simulation results were verified using the experimental measurements. However, to more precisely reproduce the DRF for the phoswich, further studies in relation to the electron channeling effect and the Doppler broadening effect of a scintillator are still needed as well as considering that effect of the transfer contribution.

Assessment of Dose Distribution using the MIRD Phantom at Uterine Cervix and Surrounding Organs in High Doserate Brachytheraphy (자궁주위 방사선 근접치료시 MIRD 팬텀을 이용한 주변장기의 피폭환경평가)

  • Lee, Yun-Jong;Nho, Young-Chang;Lee, Jai-Ki
    • Korean Journal of Environmental Biology
    • /
    • v.24 no.4
    • /
    • pp.387-391
    • /
    • 2006
  • Computational and experimental dosimetry of Henschke applicator with respect to high dose rate brachytherapy using the MIRD phantom and a remote control afterloader were performed. A comparison of computational dosimetry was made between the simulated Monte Carlo dosimetry and GAMMADOT brachytherapy Planning system's dosimetry. Dose measurements was performed using ion chamber in a water phantom. Dose rates are calculated using Monte Carlo code MCNP4B and the GAMMADOT. Thecomputational models include the detailed geometry of Ir-192 source, tandem tube, and shielded ovoids for accurate estimation. And transit dose delivered during source extension to and retraction from a given dwell position was estimated by Monte Carlo simulations. Point doses at ICRU bladder/rectal pointswhich have been recommened by ICRU 38 was assessed. Calculated and measured dose distribution data agreed within 4% each other. The shielding effect of ovoids leads to 19% and 20% dose reduction at bladder surface and rectal points.

Analysis of Beam Hardening of Modulation Layers for Dual Energy Cone-beam CT (에너지 변조 필터로 구현한 이중 에너지 콘빔 CT의 에너지 스펙트럼 평가 연구)

  • Ahn, Sohyun;Cho, Sam Ju;Keum, Ki Chang;Choi, Sang Gyu;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.27 no.1
    • /
    • pp.8-13
    • /
    • 2016
  • Dual energy cone-beam CT can distinguish two materials with different atomic compositions. The principle of dual energy cone-beam CT based on modulation layer is that higher energy spectrum can be acquired at blocked x-ray window. To evaluate the possibility of modulation layer based dual energy cone-beam CT, we analyzed x-ray spectrum for various thicknesses of modulation layers by Monte Carlo simulation. To compare with the results of simulation, the experiment was performed on prototype cone-beam CT for 50~100 kVp with CdTe XR-100T detector. As the result of comparing, the mean energy of energy spectrum for 80 kVp are well matched with that of simulation. The mean energy of energy spectrum for 80 and 120 kVp were increased as 1.67 and 1.52 times by 2.0 mm modulation layer, respectively. We realized that the virtual dual energy x-ray source can be generated by modulation layer.

Monte Carlo Study of MOSFET Dosimeter Dose Correction Factors Considering Energy Spectrum of Radiation Field in a Steam Generator Channel Head (원전 증기발생기 수실 내 에너지 스펙트럼을 고려한 MOSFET 방사선검출기 선량보정인자 결정에 관한 몬테칼로 전산모사 연구)

  • Cho, Sung-Koo;Choi, Sang-Hyoun;Kim, Chan-Hyeong
    • Journal of Radiation Protection and Research
    • /
    • v.31 no.4
    • /
    • pp.165-171
    • /
    • 2006
  • In Korea, a real-time effective dose measurement system is in development. The system uses 32 high-sensitivity MOSFET dosimeters to measure radiation doses at various organ locations in an anthropomorphic physical phantom. The MOSFET dosimeters are, however, mainly made of silicon and shows some degree of energy and angular dependence especially for low energy photons. This study determines the correction factors to correct for these dependences of the MOSFET dosimeters for accurate measurement of radiation doses at organ locations in the phantom. For this, first, the dose correction factors of MOSFET dosimeters were determined for the energy spectrum in the steam generator channel of the Kori Nuclear Power Plant Unit #1 by Monte Carlo simulations. Then, the results were compared with the dose correction factors from 0.652 MeV and 1.25 MeV mono-energetic photons. The difference of the dose correction factors were found very negligible $(\leq1.5%)$, which in general shows that the dose corrections factors determined from 0.662 MeV and 1.25 MeV can be in a steam general channel head of a nuclear power plant. The measured effective dose was generally found to decrease bit $\sim7%$ when we apply the dose correction factors.