• Title/Summary/Keyword: 목 부위

Search Result 560, Processing Time 0.177 seconds

Postoperative Adjuvant Chemoradiotherapy in Rectal Cancer (직장암의 근치적 수술 후 보조 화학방사선요법)

  • Chang, Sei-Kyung;Kim, Jong-Woo;Oh, Do-Yeun;Chong, So-Young;Shin, Hyun-Soo
    • Radiation Oncology Journal
    • /
    • v.24 no.3
    • /
    • pp.157-163
    • /
    • 2006
  • [ $\underline{Purpose}$ ]: To evaluate the role of postoperative adjuvant chemoradiotherapy in rectal cancer, we retrospectively analyzed the treatment outcome of patients with rectal cancer taken curative surgical resection and postoperative adjuvant chemoradiotherapy. $\underline{Materials\;and\;Methods}$: A total 46 patients with AJCC stage II and III carcinoma of rectum were treated with curative surgical resection and postoperative adjuvant chemoradiotherapy. T3 and T4 stage were 38 and 8 patients, respectively. N0, N1, and N2 stage were 12, 16, 18 patients, respectively. Forty patients received bolus infusions of 5-fluorouracil ($500\;mg/m^2/day$) with leucovorin ($20\;mg/m^2/day$), every 4 weeks interval for 6 cycles. Oral Uracil/Tegafur on a daily basis for $6{\sim}12$ months was given in 6 patients. Radiotherapy with 45 Gy was delivered to the surgical bed and regional pelvic lymph node area, followed by $5.4{\sim}9\;Gy$ boost to the surgical bed. The follow up period ranged from 8 to 75 months with a median 35 months. $\underline{Results}$: Treatment failure occurred in 17 patients (37%). Locoregional failure occurred in 4 patients (8.7%) and distant failure in 16 patients (34.8%). There was no local failure only. Five year actuarial overall survival (OS) was 51.5% and relapse free survival (RFS) was 58.7%. The OS and RFS were 100%, 100% in stage N0 patients, 53.7%, 47.6% in N1 patients, and 0%, 41.2% in N2 patients (p=0.012, p=0.009). The RFS was 55%, 78.5%, and 31.2% in upper, middle, and lower rectal cancer patients, respectively (p=0.006). Multivariate analysis showed that N stage (p=0.012) was significant prognostic factor for OS and that N stage (p=0.001) and location of tumor (p=0.006) were for RFS. Bowel complications requiring surgery occurred in 3 patients. $\underline{Conclusion}$: Postoperative adjuvant chemoradiotherapy was an effective modality for locoregional control of rectal cancer. But further investigations for reducing the distant failure rate are necessary because distant failure rate is still high.

Division of the N2 Stage According to the Multiplicity of the Involved Nodal Stations May be Necessary in the N2-NSCLC Patients Who are Treated with Postoperative Radiotherapy (비소세포성 폐암으로 수술 후 방사선치료가 시행된 N2병기 환자들에서 다발 부위 종격동 림프절 전이 여부에 따른 N2병기 구분의 임상적 의미)

  • Yoon, Hong-In;Kim, Yong-Bae;Lee, Chang-Geol;Lee, Ik-Jae;Kim, Song-Yih;Kim, Jun-Won;Kim, Joo-Hang;Cho, Byung-Chul;Lee, Jin-Gu;Chung, Kyung-Young
    • Radiation Oncology Journal
    • /
    • v.27 no.3
    • /
    • pp.126-132
    • /
    • 2009
  • Purpose: We wanted to evaluate the prognostic factors for the pathologic N2 non-small cell lung cancer (NSCLC) patients who were treated by postoperative radiotherapy. Materials and Methods: We retrospectively reviewed 112 pN2 NSCLC patients who underwent surgery and postoperative radiotherapy (PORT) From January 1999 to February 2008. Seventy-five (67%) patients received segmentectomy or lobectomy and 37 (33%) patients received pneumonectomy. The resection margin was negative in 94 patients, and it was positive or close in 18 patients. Chemotherapy was administered to 103 (92%) patients. Nine (8%) patients received PORT alone. The median radiation dose was 54 Gy (range, 45 to 66), and the fraction size was 1.8~2 Gy. Results: The 2-year overall survival (OS) rate was 60.2% and the disease free survival (DFS) rate was 44.7% for all the patients. Univariate analysis showed that the patients with multiple-station N2 disease had significantly reduced OS and DFS (p=0.047, p=0.007) and the patients with an advanced T stage ($\geq$T3) had significantly reduced OS and DFS (p<0.001, p=0.025). A large tumor size ($\geq$5 cm) and positive lymphovascular invasion reduced the OS (p=0.035, 0.034). Using multivariate analysis, we found that multiple-station N2 disease and an advanced T stage ($\geq$T3) significantly reduced the OS and DFS. Seventy one patients (63.4%) had recurrence of disease. The patterns of failure were loco-regional in 23 (20.5%) patients, distant failure in 62 (55.4%) and combined loco-regional and distant failure in 14 (12.5%) patients. Conclusion: Multiple involvement of mediastinal nodal stations for the pN2 NSCLC patients with PORT was a poor prognostic factor in this study. A prospective study is necessary to evaluate the N2 subclassification and to optimize the adjuvant treatment.

Skin Damage Sustained During Head-and-Neck and Shoulder Radiotherapy Due to the Curvature of Skin and the Use of Immobilization Mask (머리-목 그리고 어깨의 방사선 치료 시 피부곡면과 고정장치로 인한 피부손상연구)

  • Kim, Soo-Kil;Jeung, Tae-Sig;Lim, Sang-Wook;Park, Yeong-Mouk;Park, Dahl
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.86-92
    • /
    • 2010
  • The purpose of this study was to measure curvature contour skin dose using radiochromic film and TLD for a conventional open field. We also attempted to quantify the degradation of skin sparing associated with use of immobilization devices for high energy photon beams and to calculate the skin dose with a help of Monte Carlo (MC) simulation. To simulate head-and-neck and shoulder treatment, a cylindrical solid water phantom 11 cm in diameter was irradiated with 6 MV x-rays using $40{\times}40\;cm^2$ field at 100 cm source axis distance (SAD) to the center of the phantom. Aquaplastic mesh mask was placed on the surface of the cylindrical phantom that mimicked relevant clinical situations. The skin dose profile was obtained by taking measurements from $0^{\circ}$ to $360^{\circ}$ around the circumference of the cylindrical phantom. The skin doses obtained from radiochromic film were found to be 47% of the maximum dose of $D_{max}$ at the $0^{\circ}$ beam entry position and 61% at the $90^{\circ}$ oblique beam position without the mask. Using the mask (1.5 mm), the skin dose received was 59% at $0^{\circ}$ incidence and 78% at $80^{\circ}$ incidence. Skin dose results were also gathered using thin thermoluminescent dosimeters (TLD). With the mask, the skin dose was 66% at $0^{\circ}$ incidence and 80% at $80^{\circ}$ incidence. This method with the mask revealed the similar pattern as film measurement. For the treatments of the head-and-neck and shoulder regions in which immobilization mask was used, skin doses at around tangential angle were nearly the same as the prescription dose. When a sloping skin contour is encountered, skin doses may be abated using thinner and more perforated immoblization devices which should still maintain immoblization.

Habitation of the Insect Vector, Monochamus alternatus of Pine Wood Nematode on Height Sound Stumps by Felling Seasons (벌채시기와 그루터기 높이가 소나무재선충병의 매개충인 솔수염하늘소의 서식에 미치는 영향)

  • Jeon, Kwon-Seok;Park, Nam-Chang;Lee, Sung-Min;Choi, Hae-Woong;Hong, Sung-Cheon
    • Journal of Korean Society of Forest Science
    • /
    • v.102 no.2
    • /
    • pp.170-175
    • /
    • 2013
  • This study was conducted to investigate the effect on the habitation of Monochamus alternatus, a vector insect of Pine wood nematode by the tended sound stumps for the developing forestry control methods of Pine wilt disease controls. Field cage plots (1 m ${\times}$ 1 m ${\times}$ 1 m) were established 12 units (Experiment1:4 units, Experiment2:8 Units) and were treated 4 kinds(February in 2010, February, April, June in 2011). The adults of M. alternatus were put into 4~5couples each the cage June in 2011. Presence or absence of the larva entrance holes and larva were detailed November in 2011. The larva were appeared in the sound stumps of sapling and young trees tended at February, April, June, the current emergence year of M. alternatus, but were not appeared in the sound stumps of sapling and young trees tended February in 2010, one year before the emergence of M. alternatus. The larva habitated in stumps of sapling were likely to be smaller in size in compare to the larva in stumps of young trees. In case of young tree, the larva were found at the cleft part of bark, but were not found at ridge part of bark. All observed larva appeared at part of bark and between the bark and the woody parts, but were not found at the woody parts. To develop the control guiding principal of sound stump after forest tending practice, further experiment need is in existence oviposition and larvae of vectors by height of stemps.

The Usefulness of Diagnostic Scan Using Technetium-99m Pertechnetate Scintigraphy prior to the First Ablative Radioiodine Treatment in Patients with Well Differentiated Thyroid Carcinoma: A Comparative Study with Iodine-131 (분화된 갑상선암 수술 후 초치료에 있어서 Tc-99m Pertechnetate을 이용한 진단 스캔의 유용성: Iodine-131 스캔과의 비교)

  • Yoon, Seok-Nam;Park, Chan-H.;Hwang, Kyung-Hoon;Kim, Su-Zy;Soh, Eui-Young;Kim, Kyung-Rae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.4
    • /
    • pp.285-293
    • /
    • 2000
  • Purpose: A prospective comparison was made between imaging with Tc-99m pertechnetate (Tc-99m) and Ioine-131 (I-131) for the detection of residual and metastatic tissue after total thyroidectomy in patients with well-differentiated thyroid carcinoma. Materials and Methods: Initially our patients had imaging with Tc-99m, followed by I-131 within 3 days. The study included 21 patients who had ablation with high dose of I-131 ranging from 100 mCi to 150 mCi. Planar and pinhole images were acquired for both Tc-99m and I-131. Diagnostic images of Tc-99m and I-131 were compared with post-therapy images. Degree of uptake on Tc-99m and I-131 images was scored by four point scale and compared. Results: The results of the Tc-99m study were: 16 of 19 studies (84%) were positive on simple planar images, but 19 of 20 studies (95%) were positive on pinhole images. Conventional I-131 diagnostic imaging on the other hand showed that all studies (100%) were positive on both planar and pinhole images. There was a significant difference in degree of uptake between Tc-99m and I-131 planar images (p<0.05). Only one case of Tc-99m scintigraphy was negative on both planar and pinhole studies (false negative). There was no distant metastasis on the therapeutic I-131 images. Conclusion: Tc-99m scan using pinhole in certain clinical situations is an alternative to the I-131 scan in detecting thyroid or lymph node metastasis prior to the first ablative treatment after thyroidectomy for well-differentiated thyroid carcinoma.

  • PDF

Incase of Same Region Treatment by using a Tomotherapy and a Linear Accelerator Absorbed Dose Evaluation of Normal Tissues and a Tumor (토모테라피와 선형가속기를 이용한 동일 부위의 치료 시 종양 및 정상조직의 흡수선량 평가)

  • Cheon, Geum-Seong;Kim, Chang-Uk;Kim, Hoi-Nam;Heo, Gyeong-Hun;Song, Jin-Ho;Hong, Joo-Yeong;Jeong, Jae-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.97-103
    • /
    • 2010
  • Purpose: Treating same region with different modalities there is a limit to evaluate the total absorbed dose of normal tissues. The reason is that it does not support to communication each modalities yet. In this article, it evaluates absorbed dose of the patients who had been treated same region by a tomotherapy and a linear accelerator. Materials and Methods: After reconstructing anatomic structure with a anthropomorphic phantom, administrate 45 Gy to a tumor in linac plan system as well as prescribe 15 Gy in tomotherapy plan system for make an ideal treatment plan. After the plan which made by tomoplan system transfers to the oncentra plan system for reproduce plan under the same condition and realize total treatment plan with summation 45 Gy linac treatment plan. To evaluate the absorbed dose of two different modalities, do a comparative study both a simple summation dose values and integration dose values. Then compare and analyze absorbed dose of normal tissues and a tumor with the patients who had been exposured radiation by above two differents modalities. Results: The result of compared data, in case of minimum dose, there are big different dose values in spleen (12.4%). On the other hand, in case of the maximum dose, it reports big different in a small bowel (10.2%) and a cord (5.8%) in head & neck cancer patients, there presents that oral (20.3%), right lens (7.7%) in minimum dose value. About maximum dose, it represents that spinal (22.5), brain stem (12%), optic chiasm (8.9%), Rt lens (11.5%), mandible (8.1%), pituitary gland (6.2%). In case of Rt abdominal cancer patients, there represents big different minimum dose as Lt kidney (20.3%), stomach (8.1%) about pelvic cancer patients, it reports there are big different in minimum dose as a bladder (15.2%) as well as big different value in maximum dose as a small bowel (5.6%), a bladder (5.5%) in addition, making treatment plan it is able us to get. Conclusion: In case of comparing both simple summation absorbed dose and integration absorbed dose, the minimum dose are represented higher as well as the maximum dose come out lower and the average dose are revealed similar with our expected values data. It is able to evaluate tumor & normal tissue absorbed dose which could had been not realized by treatment plan system. The DVH of interesting region are prescribed lower dose than expected. From now on, it needs to develop the new modality which are able to realize exact dose distribution as well as integration absorbed dose evaluation in same treatment region with different modalities.

  • PDF

Evaluation of compensator to reduce thermal sensation in oncological hyperthermia (고주파 온열암 치료 시 열감감소를 위해 자체 제작한 보상체의 유효성 평가)

  • Lee, Yeong Cheol;Kim, Sun Myung;Jeong, Deok Yang;Kim, Young Bum
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.27-32
    • /
    • 2017
  • Objectives: Oncological hyperthermia is a treatment to selectively kill cancer cells by directly applying heat to cancer cells or indirectly demage cancer cells. One of the most side effects of treatment is burn that can appear on the skin. In areas with irregularities such as the umbilicus, the patient feels a sense of hot and treatment may be discontinued. Therefore, in order to eliminate the irregularities of these areas, compensators are manufactured and measured to decrease in temperature. Materials and Methods: The temperature of the four sites (umbilicus, near the umbilicus, 5 cm below the umbilicus, back) was measured five times around the umbilicus in patients who were treated at oncological hyperthermia treatment device(EHY-2000, Oncotherm Kft, Hungary). The temperature sensor (TM-100, Oncotherm Kft, Hungary) was attached to four sites and the changes were observed at 5, 15, 25, 35, and 50 minutes after treatment. Compensators of three materials were used(Vaseline, Bolus, Dental resin). The data measured five times were compared for each compensator. Results: The temperature change when the compensator was not used increase from 34.65 degrees to 42.9 degrees on average. The near umbilicus was changed from 32.20 degrees to 37.00 degrees, and the 5 cm below the umbilicus was changed from 31.90 to 34.41 degrees. When the compensator material was inserted into the umbilicus, the temperature change was measured as 5.42 degrees for bolus, 6.55 degrees for vaseline, and 6.83 degrees for resin. Conclusion: Using the compensator in the region where the irregularities such as the umbilicus, the heat sensation could be reduced. the use of a resin that can be customized not only lowers the temperature but also significantly reduces the feeling of the patient. It will be possible to reduce the heat sensation in the treatment and to treat it in a more comfortable condition.

  • PDF

The Clinical Aspects of Acute Septic Arthritis and Acute Osteomyelitis in Children (소아기 급성 화농성 관절염과 급성 골수염의 임상적 고찰)

  • Kim, Jin-Man;Lee, So-Yeon;Kim, Young-Ho;Shin, Eon-Woo;Oh, Phil-Soo;Kim, Kwang-Nam
    • Pediatric Infection and Vaccine
    • /
    • v.12 no.2
    • /
    • pp.149-156
    • /
    • 2005
  • Purpose : Acute septic arthritis and acute osteomyelitis are not rare diseases in pediatric population. But when the diagnosis is delayed or inappropriate treatments are given, permanent disabilities of joint or bone can be followed. We analysed clinical manifestations, laboratory findings, X-ray findings, causative microorganisms and antibiotic susceptibility results of the two diseases in children. Methods : During January 1992 and May 2002, we conducted a retrospective study of 103 children who were diagnosed as acute septic arthritis and acute osteomyelitis. We selected out 34 children who had positive culture results in the blood or involved sites. Results : 19 cases were diagnosed as acute septic arthritis and 15 cases were acute osteomyelitis. These diseases were most common in preschool children and next in neonates. Hip joints and tibia were the most common sites in each disease. X-ray findings showed abnormalities in 6 cases(36%) of acute septic arthritis and 7 cases(50%) of acute osteomyelitis on admission. The most common microorganism isolated from the involved sites was Staphylococcus aureus; 12 out of 14 cases in acute septic arthritis and 6 out of 13 cases in acute osteomyelitis. Conclusion : It is difficult to make a clear initial diagnosis of the two diseases. We could not find any differences between these two diseases on clinical manifestations such as fever, swelling, tenderness and limitation of movements in joint and bone. The most common microorganism was Staphylococcus aureus.

  • PDF

Quantitative Assessment of Myocardial Tissue Velocity in Normal Children with Doppler Tissue Imaging : Reference Values, Growth and Heart Rate Related Change (소아에서 도플러 조직영상을 이용한 최대 심근 속도의 계측 : 정상 추정치 및 성장 및 심박동수에 따른 변화)

  • Kim, Se Young;Hyun, Myung Chul;Lee, Sang Bum
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.8
    • /
    • pp.846-856
    • /
    • 2005
  • Purpose : To measure the peak myocardial tissue velocities and patterns of longitudinal motion of atrioventricular(AV) annuli and assess body weight and heart rates-related changes in normal children. Methods : Using pulsed wave Tissue Doppler Imaging(TDI), we measured peak systolic, early and late diastolic myocardial velocities in 72 normal children at six different sites in apical-4 chamber (A4C) view and at four different sites in apical-2 chamber(A2C) view and compared those values with each other, also observing effects with body weights and heart rates. Longitudinal motions of the AV annuli were measured at three different sites in A4C. Results : There were no significant differences of the TDI parameters between gender, ECHO-machines and among the three Doctors performing TDI. Peak myocardial velocities were significantly higher at the base of the heart than in the mid-ventricular region and in the right lateral ventricular wall than in the left lateral ventricular wall or IVS. The TDI parameters showed no significant correlation with fractional shortening(%). Peak systolic and early diastolic myocardial velocities had no correlation with heart rates, but peak late diastolic velocities and A/E ratio correlated positively with heart rates. Correlations between the TDI parameters and body weight were inconsistent. Absolute longitudinal displacement and % displacement were not differ between gender and not correlated with the TDI parameters. Conclusion : We measured the peak myocardial velocities with TDI and the longitudinal motion of the AV annuli using M-mode echocardiography in normal children. With more large scale evaluation, we may establish reference values in normal children and broaden clinical applicabilities in congenital and acquired heart diseases.

Comparison and Evaluation of radiotherapy plans by multi leaf collimator types of Linear accelerator (선형가속기의 다엽콜리메이터 형태에 따른 치료계획 비교 평가)

  • Lim, Ji Hye;Chang, Nam Joon;Seok, Jin Yong;Jung, Yun Ju;Won, Hui Su;Jung, Hae Youn;Choi, Byeong Don
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.129-138
    • /
    • 2018
  • Purpose : An aim of this study was to compare the effect of multi leaf collimator(MLC) types for high dimension radiotherapy in treatment sites used clinically. Material and Method : 70 patients with lung cancer, spine cancer, prostate cancer, whole pelvis, head and neck, breast cancer were included in this study. High definition(HD) MLC of TrueBeam STx (Varian Medical system, Palo Alto, CA) and millenium(M) MLC of VitalBeam (Varian Medical system, Palo Alto, CA) were used. Radiotherapy plans were performed for each patient under same treatment goals with Eclipse (Version 13.7, Varian Palo Alto USA, CA). To compare the indicators of the radiotherapy plans, planning target volume(PTV) coverage, conformity index(CI), homogeneity index(HI), and clinical indicators for each treatment sites in normal tissues were evaluated. To evaluate low dose distribution, $V_{30%}$ values were compared according to MLC types. Additionally, length and volume of targets for each treatment sites were investigated. Result : In stereotatictic body radiotherapy(SBRT) plan for lung, the average value of PTV coverage was reduced by 0.52 % with HD MLC. With SBRT plan using HD MLC for spine, the average value of PTV coverage decreased by 0.63 % and maximum dose decreased by 1.13 %. In the test of CI and HI, the values in SBRT plan with HD MLC for spine were 1.144, 1.079 and the values using M MLC were 1.160, 1.092 in SBRT plan for lung, The dose evaluation of critical organ was reduced by 1.48 % in the ipsilateral lung mean dose with HD MLC. In prostate cancer volumetric modulated arc therapy(VMAT) with HD MLC, the mean dose and the $V_{30}$ of bladder and the mean dose and the $V_{25}$ of rectum were reduced by 0.53 %, 1.42 %, 0.97 %, and 0.69 %, respectively (p<0.05). The average value of heart mean dose was reduced by 0.83 % in breast cancer VMAT with M MLC. Other assessment indices for treatment sites showed no significant difference between treatment plans with two types of MLC. Conclusion : Using HD MLC had a positive impact on the PTV coverage and normal tissue sparing in usually short or small targets such as lung and spine SBRT and prostate VMAT. But, there was no significant difference in targets with long and large such as lung, head and neck, and whole pelvis for VMAT.

  • PDF