• Title/Summary/Keyword: 목표슬럼프

Search Result 50, Processing Time 0.024 seconds

A Study on the Chemical Admixture According to Target Slump Value by Crushed Sand Replacement Rate (부순모래 치환율별 목표슬럼프 값 고정에 따른 화학혼화제의 특성에 관한 연구)

  • Ryu, Hyun-Gi;Cho, Myeong-Ken
    • Journal of the Korea Institute of Building Construction
    • /
    • v.8 no.4
    • /
    • pp.87-93
    • /
    • 2008
  • With an increased use of alternative aggregate due to exhaustion of quality aggregate resources, the amount of used crushed aggregates have been increased and as a result, development of admixture materials has also been improved and its amount of use is increasing from day to day in order to secure quality in concrete. Accordingly, the purpose of this study is to make concrete of good quality by using chemical admixture developed in this study by replacement rate of fine aggregate. At first, susceptibility, compressive strength ratio and length change ratio in both fresh and hardened concrete were evaluated according to corresponding regulation. As for high performance related regulation, APC NO.3 and PC series were going to rule, and as for AE agent regulation, replacement ratio of fine aggregate of high performance chemical admixture was 10:0 and other chemical admixture met quality regulation for AE agent.

Study on the Performance Evaluation of CS-H Wall composed of Steel Fiber (강섬유를 이용한 CS-H 벽체의 성능 평가에 관한 연구)

  • YU, Nam-Jae;Lee, Kang-Il
    • Journal of the Korean Geosynthetics Society
    • /
    • v.16 no.2
    • /
    • pp.89-96
    • /
    • 2017
  • In this study, CS-H walls with large stiffness were constructed using geosythetics for use in excavation at a depth of 30 m or more in Korea, and in order to construct the CS-H wall suitable for the site conditions, the formulation was examined according to the change in the mixing ratio of the geosythetics and the slump value (slump flow) and as a result, in the target slump 180 mm and the slump flow 500 mm, the formulation was confirmed to meet the mechanical properties such as the initial bending strength, the long-term behavior, and the elastic modulus as well as the economic efficiency. However, in the slump flow 600 mm, the result indicated that the formulation was inappropriate in the mechanical properties such as the initial bending strength, the long-term behavior, and the elastic modulus.

Prediction on Mix Proportion Factor and Strength of Concrete Using Neural Network (신경망을 이용한 콘크리트 배합요소 및 압축강도 추정)

  • 김인수;이종헌;양동석;박선규
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.4
    • /
    • pp.457-466
    • /
    • 2002
  • An artificial neural network was applied to predict compressive strength, slump value and mix proportion of a concrete. Standard mixed tables were trained and estimated, and the results were compared with those of the experiments. To consider variabilities of material properties, the standard mixed fables from two companies of Ready Mixed Concrete were used. And they were trained with the neural network. In this paper, standard back propagation network was used. The mix proportion factors such as water cement ratio, sand aggregate ratio, unit water, unit cement, unit weight of sand, unit weight of crushed sand, unit coarse aggregate and air entraining admixture were used. For the arrangement on the approval of prediction of mix proportion factor, the standard compressive strength of $180kgf/cm^2{\sim}300kgf/cm^2$, and target slump value of 8 cm, 15 cm were used. For the arrangement on the approval of prediction of compressive strength and slump value, the standard compressive strength of $210kgf/cm^2{\sim}240kgf/cm^2$, and target slump value of 12 cm and 15 cm wore used because these ranges are most frequently used. In results, in the prediction of mix proportion factor, for all of the water cement ratio, sand aggregate ratio, unit water, unit cement, unit weight of sand, unit weight of crushed sand, unit coarse aggregate, air entraining admixture, the predicted values and the values of standard mixed tables were almost the same within the target error of 0.10 and 0.05, regardless of two companies. And in the prediction of compressive strength and slump value, the predicted values were converged well to the values of standard mixed fables within the target error of 0.10, 0.05, 0.001. Finally artificial neural network is successfully applied to the prediction of concrete mixture and compressive strength.

Physical Properties of Self-healing Concrete Mixed with Hydrogel Carrier of Microorganism (미생물 혼입 하이드로젤 지지체 첨가에 따른 자기치유 콘크리트의 물성 변화)

  • Chu, Inyeop;Woo, Jinho;Woo, Sang-Kyun;Lee, Byungjae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.6
    • /
    • pp.24-29
    • /
    • 2018
  • The properties of concrete with addition of microgel - containing hydrogel support were investigated. As a result of measuring the slump of the self - healing concrete, the target slump was satisfied in all the mixing conditions, but the slump was decreased as the mixing amount of the hydrogel support increased. The change of porosity due to incorporation of hydrogel support was minimal. As a result of the evaluation of the compressive strength of the self - healing concrete, the incorporation of the hydrogel support did not affect the strength. However, under the same mixing condition, the dispersion value of the specimens tended to increase with increasing hydrogel support contents. As a result of the permeability test of self-healing concrete according to the incorporation of hydrogel support, it was confirmed that the mixing ratio of hydrogel support was effective to decrease the permeability coefficient.

The Fundamental Properties of High-Strength Concrete Using Pre-mixed Cement Corresponding to Water Binder Ratio (물 결합재비 변화에 따른 프리믹스 시멘트를 사용한 고강도 콘크리트의 기초적 특성)

  • Jin, Cheong-Ri;Han, Dong-Yeop;Kim, Ki-Hoon;Hwang, Yin-Seong;Kim, Sung-Su;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.369-372
    • /
    • 2008
  • This study analysis fundamental properties of high-strength concrete corresponding to W/B ratio for suggested table of high strength concrete, mixed with premixed cement. As a result of this study, the amount of using air entraining and high-range water reducing agent for intended slump flow and air content decreased as W/B increased, and the setting time corresponding to the W/B ratio delayed as W/B ratio increased except 20% W/B ratio. The compressive strength according to W/B ratio decreased as W/B ratio increased, and there was no great deferent as the intended slump flow. Also it could possible to use this study at work as the correlation coefficient is high enough as 0.9646 substituting B/W and compressive strength for the regression formula.

  • PDF

The Quality Properties of Self-Compacting Concrete Mixed with Tailing from the Sangdong Tungsten Mine (상동광산 광미를 혼합한 자기충전 콘크리트의 품질 특성)

  • Choi, Yun-Wang;Kim, Yong-Jic;Choi, Wook
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.6 s.96
    • /
    • pp.777-783
    • /
    • 2006
  • This study has focused on the possibility for recycling of tailings from the Sangdong tungsten mine as powder(TA) of self-compacting concrete(SCC). The experimental tests for slump-flow, time required to reach 500 mm of slump flow(sec), time required to flow through V-funnel(sec) and filling height of U-box test(mm) were carried out in accordance with the specified by the Japanese Society of Civil Engineering(JSCE). The results of this study, slump-flow of SCC was satisfied a prescribed range. And time required to reach 500 mm of slump flow(sec) and time required to flow through V-funnel(sec) decreased with increasing replacement of TA. But filling height of U-box test(mm), replacement of TA up to 30% were satisfied a prescribed range. The mechanical properties including compressive strength, splitting tensile strength and elastic modulus were checked with the requirements specified by Korean Industrial Standards(KS). The compressive strength of SCC decreased with increasing replacement of TA, splitting tensile strength and elastic modulus were similar to those of normal concrete. The fundamental durability was reviewed through the dry shrinkage rate and accelerated carbonation tests. As the result dry shrinkage rate and accelerated carbonation depth increased with increasing replacement of TA.

Durability of Concrete Using Insulation Performance Improvement Materials (단열성능 향상 재료를 사용한 콘크리트의 내구성에 관한 연구)

  • Park, Young-Shin;Kim, Jung-Ho;Kim, Se-Hwan;Kim, Sang-Heon;Jeon, Hyun-Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.3
    • /
    • pp.22-29
    • /
    • 2015
  • In this study, we tested to develop and apply structural insulation performance improvement concrete to field, which had compressive strength in 24 MPa and thermal conductivity twice as much as normal concrete. After experiment about slump and air contents, combination product of Plain and calcined diatomite powder showed reduction of slump and air contents and combination product with micro foam cell admixture, we cannot find result of slump and air contents reduction. Unit weight of combination product with insulation performance improvement materials decreased more than that of Plain. In the test of compressive strength, compressive strength of insulation performance improvement concrete decreased more than that of Plain but was content with 24 MPa. thermal conductivity of insulation performance improvement concrete tended to decrease. Freezing and thawing resistance of insulation performance improvement concrete was similar to that of Plain. In carbonation resistance test, combination product with calcined diatomite powder showed the result which was similar to that of Plain. In carbonation resistance test, combination product with micro foam cell admixture showed a increase compared to that of Plain and length variation of combination product generally increased.

Evaluation on Mechanical and Mixing Properties of Ultra-high Strength Concrete with fck=150MPa (150MPa 초고강도 콘크리트의 배합 및 재료역학특성 평가 연구)

  • Kang, Hoon;Ahn, Jong-Mun;Shin, Sung-Woo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.3
    • /
    • pp.113-120
    • /
    • 2010
  • Ultra-High Strength Concrete (UHSC) demands a clear presentation of its mechanical properties, as distinct from normal strength concrete, and an evaluation of the serviceability of high-rise buildings that use ultra-high strength concrete. Ultra-high strength concrete fck=150MPa was manufactured with pre-mix cement, and an experimental study was conducted to evaluate the mixing properties and compressive strength, with the major variables being unit cement contents, water-binder ratio, and type of pre-mix cement. The test result showed that 150MPa concrete requires about 6~7 minutes of mixing time until each of the materials (ordinary Portland cement, silica fume, blast-furnace slag powder and anhydrite) are sufficiently revitalized. The slump flow of fresh concrete was shown to be about 700~800mm with the proper viscosity. The average value of concrete compressive strength was shown to be about 70% in 7 days, 85% in 14 days, and 95% in 28 days, for 56 days of concrete material age.

An Experimental Study for Improving the Applicability of High-Strength Concrete (고강도 콘크리트의 실용성 향상을 위한 실험적 연구)

  • 유영찬;민병렬
    • Magazine of the Korea Concrete Institute
    • /
    • v.4 no.2
    • /
    • pp.83-92
    • /
    • 1992
  • 본 연구의 목적은 현장에서 구입 가능한 저품질의 재료를 사용한 일련의 실험을 통하여 28일 압축강도와 물\ulcorner시멘트비와 관계를 유출함으로써 고강도 콘크리트의 배합설계식을 얻기 위한 것이다. 목표슬럼프는 고층건물에서의 시공성을 고려하여 15$\pm$2cm로 하였으며 혼화제로는 고성능감수제를 사용하였다. 실험결과로부터 고강도콘크리트의 응력-변형도 특성을 비롯하여 탄성계수, 포아송비, 단위중량 등 고강도 콘크리트의 일반적인 재료성질을 얻었으며 본 연구에서 제안한 고강도콘크리트의 배합설계식은 국내현장조건을 고려한 실용식으로 고강도콘크리트으 설계 및 시공을 위한 기초자료로 사용 가능하다고 판단된다.

An Economic Mix Design Methodology for the Development of Concrete Strength at Low Temperature (저온에서의 콘크리트 강도 확보를 위한 경제적 배합 방안)

  • Kim, Sang-Chel;Kim, Yong-Jic;Kim, Young-Jin
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.7 no.4
    • /
    • pp.95-103
    • /
    • 2012
  • Precast concrete method is known to have advantages of minimizing works in the construction, controlling concrete quality easily and saving construction period due to only fabrication work in the construction field, but it needs to apply steam curing to accelerate early concrete strength. In the meanwhile, the oil cost for steam curing has been continuously increased because of political instability in the middle East and international economic shaky. Thus, this study addresses the development of precast/ prestressed concrete which has over 14MPa at 1 day age and specified concrete strength of 40MPa at low temperature, not applying steam curing. Tests were carried out in terms of material characteristics in fresh concrete and compressive strength using 3 types of cement such as Type I, Type III and rapid hardening compound cement. As results of tests, it is found that cements for rapid hardening had disadvantages with respect to slump, slump loss, and air content, but showed higher compressive strength than specified one, especially the highest value when using rapid hardening compound.

  • PDF