삼차원 유동해석을 통한 침전조의 침전효율 예측 및 형상설계 (Shape Design and Prediction of Efficiency of Sedimentation Bed using Three-Dimensional Flow Analysis)

  • 최상철;김홍민;김광용
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.95-98
    • /
    • 2002
  • Three-dimensional flow analyses for two different ratios of radius to height of sedimentation bed are implemented to evaluate the effect of blockage ratio of center feed wall and angle of distributor on sedimentation efficiency, and to find the optimal value of those parameters. Sedimentation efficiencies for three different shapes are compared with and without rotation speed. And then, five different combinations of blockage ratio of center feed wall and angle of distributor are compared It reveals that the effect of blockage ratio of center fled wall and angle of distributor is considerable to sedimentation efficiency while rotation effect can be neglected and $0.55 and 33^{\circ}$for blockage ratio of center food wall and angle of distributor, respectively, ive the best sedimentation efficiency.

  • PDF

유턴 흐름을 갖는 차량공조용 플레이트형 증발기의 전열특성에 관한 연구 (A study on the characteristics of heat transfer and pressure drop in plate type evaporator with U-turn for automotive air conditioner)

  • 강정길;김종수
    • 설비공학논문집
    • /
    • 제11권4호
    • /
    • pp.472-483
    • /
    • 1999
  • The evaporation heat transfer and pressure drop characteristics for HFC-l34a in flat plate type heat exchangers with enhanced beads were experimentally investigated. Three plate type evaporators with different geometric condition of U-turn area were tested. Mass fluxes were tested over the range of 83kg/$m^2$s to 166kg/$m^2$s, and heat fluxes were varied from 4㎾/$m^2$ to 12㎾/$m^2$. Evaporation temperature was 5$^{\circ}C$ with inlet qualities of 0.1 to 1.0. There was no notable difference in the heat transfer coefficient by geometric variation of U-turn area, but the third plate with cross-ribbed channel at U-turn area was better than others in the evaluation using volume goodness factor comparison. Also, the mixtures of HFC-l34a and PAG oil was tested to determine oil effects on heat transfer and pressure drop. As oil concentration was increased, heat transfer coefficient was increased by 22~48% up to the 3wt.%, but decreased by 14~22% at the 4wt.%. The pressure drop was increased by the maximum of 100% as oil concentration was increased.

  • PDF

연료 송출용 제트펌프 3차원 전산해석 모델 (Three Dimensional Simulation Model of Fuel Delivery Jet Pump)

  • 박다인;윤진원;유상석
    • 한국수소및신에너지학회논문집
    • /
    • 제28권3호
    • /
    • pp.308-314
    • /
    • 2017
  • Jet pump in automotive fuel tank module is used to deliver fuel to fuel pump so that the pump is operated without aeration in suction side. In this study, three dimensional simulation model of jet pump is developed to understand performance variation over design parameters. Performance of jet pump is also investigated experimentally in terms of operating pressures. The experimental data is used to verify the three dimensional simulation model of jet pump. Verification results show that the three dimensional simulation model of jet pump is about 1% error with experiment. The simulations are conducted in terms of throat ratio and primary flow induction angle. As the throat ratio is increased, the flux ratio is trade-off at 3 times of throat diameter. On the other hand, as primary flow induction angle is increased, vapor pressure inside the nozzle is decreased. In summary, the results show that liquid jet pump has to be optimized over design parameters. Additionally, high velocity of induced flow is able to evolve cavitation phenomena inside the jet pump.

자동차 공조용 증발기의 고성능화에 관한 연구 (Study on Development of High Performance Evaporator for Automotive Air Conditioner)

  • 강정길;김기효;박태영;김종수
    • 설비공학논문집
    • /
    • 제7권1호
    • /
    • pp.73-80
    • /
    • 1995
  • The object of the present study is to develop a high performance evaporator for automotive air conditioner. The experiment has been conducted on evaporative heat transfer coefficient inside a plate type heat exchanger with a sharp 180-degree turn flow. The test plates have different formed surface, cross-ribbed channel and elliptical-ribbed channel. Also experimental study has been performed to determine optimal design in elliptical-ribbed plate heat exchanger with different turn clearance. In addition to the above experiments, refrigerant behavior and surface temperature distribution in the plate heat exchanger were observed using color thermoviewer(infrared thermometer). In this experiment, working fluid was used R-12 and test conditions were as follows : (1) saturation pressure of $2.116kg/cm^2$, (2) mass fluxes of 40 to $70kg/m^2s$, (3) heat fluxes of 4,500 to $7,300W/m^2$, (4) inlet quality of 0.1 to 0.7. The results indicated that the evaporative heat transfer coefficient of an elliptical-ribbed plate heat exchanger was higher than that of cross-ribbed plate heat exchanger. Also optimal turn clearance in an elliptical-ribbed plate heat exchanger was determined.

  • PDF

요소·멜라민 접착제의 수지 조성에 따른 마루판의 천연무늬단판 접착성 및 포름알데히드 방출에 대한 연구 (Studies on Adhesion of Fancy Veneer and Formaldehyde Emission of Wood-Based Floorings by Mole Ratios of Urea and Melamine)

  • 강은창;박종영;박헌
    • Journal of the Korean Wood Science and Technology
    • /
    • 제30권2호
    • /
    • pp.165-171
    • /
    • 2002
  • 본 연구는 마루판의 천연무늬단판 접착에 이용되고 있는 요소-멜라민 접착제의 수지조성에 따른 접착성능 및 포름알데히드 방출량의 변화를 알아보고자 하였다. 요소에 멜라민에 대한 포름알데히드의 몰비 1.0, 1.1, 1.2, 1.4를 기준으로 제조된 접착제로 마루판용 합판과 섬유판에 천연무늬단판을 접착한 목질마루판에 의해 시험을 실시하였다. 그 결과는 화학양론적으로 멜라민-요소와 포름알데히드간의 비율이 적정한 조건에서 반응이 충분히 일어난 경우에 상태접착력, 준내수접착력, 포름알데히드 방출량 등이 가장 양호하게 나타났다. 복합마루판의 평면인장강도는 각 몰비에서 14 kgf/cm2를 상회하였으며, 포름알데히드 방출량은 1.0몰비에서 9.53 mg/L로 가장 낮게 나타났다. 합판마루판의 평면인장 접착력 시험에서는 1.4몰비에서 14.02 kgf/cm2로 가장 높은 값을 보였다. 합판마루판의 포름알데히드 방출량 조사에서도 1.0목비에서 0.26 mg/L로 가장 낮게 나타났다.