• Title/Summary/Keyword: 모형실험시스템

Search Result 851, Processing Time 0.03 seconds

Real Scale Experiment for Suspended Solid Transport Analysis and Modeling of Particle Dispersion Model (부유 물질 거동 분석을 위한 실규모 실험 및 입자 분산 모형 적용)

  • Shin, Jaehyun;Park, Inhwan;Seong, Hoje;Rhee, Dong Sop
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.12
    • /
    • pp.236-244
    • /
    • 2020
  • In this research a suspended solid transport experiment was conducted in the river experiment center to find the characteristics and dispersion of the material. Modeling by the particle dispersion model was also executed to reproduce the suspended solid transport. The suspended solid was consisted of a mixture of silica and water using a mixing equipment, which was then introduced into a real-scale flume and measured with the laser-diffraction based particle size analyzer(LISST) to find the concentration of the material. The comparison between the measured suspended solid concentration using drone images and particle size analyzers, with the model showed a good match overall, which proved the applicability of the model. Along with finding the model applicability, the research showed the potential for suspended solid estimation in high flow situations with high rainfall.

A Experimental Study on the Stabilizing Effect of Anchors against Sliding (사면에 설치된 앵커의 활동억지효과에 대한 실험적 연구)

  • Song, Young-Suk;Hong, Won-Pyo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.3C
    • /
    • pp.171-180
    • /
    • 2006
  • To investigate the stabilizing effect of anchors against sliding, a series of the model test was carried out. An apparatus was developed to perform the model test of the slope reinforced by anchors. An instrumentation system has been applied on the anchors to measure the axial force during slope failure. The maximum stabilizing effect is revealed about 0.5% of the area ratio. The initial loss of anchor force is represented about 24% of initial jacking force. This result is equaled to the proposed range(10%~25%) of the field test result(Yun, 1997). The effective jacking force corresponds to 70% of the initial jacking force. Therefore, the initial jacking force should be determined more than 30% of the design jacking force. As the initial jacking force becomes increase, the reinforced slope is transferred to brittle failure behavior due to increasing the density of slope soils.

Assessment of Lateral Behavior of Steel-concrete Composite Piles Using Full-scale Model Tests (실대형 모형 실험을 이용한 강관합성 말뚝의 수평 거동 특성 평가)

  • Kwon, Hyungmin;Lee, Juhyung;Park, Jaehyu;Chung, Moonkyung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.5C
    • /
    • pp.199-206
    • /
    • 2009
  • This paper presents full scale model tests on the various types of model piles carried out to estimate the behavior of laterally loaded steel-concrete composite piles. Subgrade-reaction spring system was developed to simulate the reaction of ground in laboratory condition. In addition, lateral behavior of piles under working load condition was estimated using composite loading system, which is available for independent loading in vertical and horizontal direction. Steel-concrete composite piles showed higher efficiency in lateral resistance rather than drilled shaft made of reinforced concrete. The lateral resistance of composite pile was larger than the summation of steel pile and concrete pile due to the composite effect by steel casing. The effect of shear key or strength of concrete on the behavior of composite pile was examined. The substitution of reinforcing bar by steel casing was also investigated.

An Experimental Study on Runoff Reducing Effect of Infiltration-Storage System due to Rainfall Intensity (강우강도에 따른 침투-저류시스템의 우수유출저감효과에 관한 실험 연구)

  • Song, Jai-Woo;Im, Jang-Hyuk
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.7 no.4
    • /
    • pp.85-95
    • /
    • 2007
  • The variation of hydraulic and hydrologic aspect of urban area according to the strongly seasonal variation of rainfall and the increment of urbanization has caused the runoff variation and increased the flood damage, and thus made a difficulty to manage water resources in urban area. Recently, as a part of efforts to resolve these problems, the facilities for reducing runoff increasing due to urbanization have a tendency to install in our country. In this study, more effective Infiltration-Storage System(ISS) is proposed and its reducing effect is analyzed by hydraulic experimental study. The infiltration characteristics of runoff reduction facilities are examined as varying artificial rainfall and a material of infiltration layers being able to consider the influence of urban development. As a result of comparison of infiltration rate of the upper and lower parts, the infiltration rate in the lower part is larger than that of the upper part. Thus, the ISS is more available than existing runoff reduction facilities. Results obtained in this study can be provided fundamental data for improvement of existing runoff reduction facilities and practical use of ISS.

A Experimental Study on the Effect of Increasing Rudder Force on Turning Ability of Short Sea Shipping Ship (타력 향상이 근해운송선박의 선회 성능에 미치는 영향에 관한 실험적 연구)

  • Jun, Hee-Chul;Kim, Sang-Hyun;Kim, Hyun-Jun;Park, Hwa-Pyeong
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.18 no.6
    • /
    • pp.591-596
    • /
    • 2012
  • Recently, a vessel's maneuvering performance is considered to be an important subject to secure safety at short sea shipping. Especially the high turning performance, which is required to avoid the marine pollution by the ships that was grounded, becomes more severe. In this paper, we discuss the effect of increasing rudder force on turning performance of short sea shipping ship by free running test in towing tank. First of all, we make the 47K PC model ship and high-lift rudder using Coanda effect. And we make the free running test system for the turning test in towing tank. And also we perform the turing test of 47K PC model in several changes of Coanda jet momentum and evaluate the turing performance such as advance and tactical diameter. Finally, we confirm that the increasing of rudder force is very effective to improvement of turning performance of short sea shipping ship.

Dynamic Response Characteristics of Embankment Model for Various Slope Angles (다양한 경사를 가지는 제방모형의 지반 증폭 특성)

  • Kim, Hoyeon;Jin, Yong;Lee, Yonghee;Kim, Hak-sung;Kim, Daehyeon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.19 no.2
    • /
    • pp.35-46
    • /
    • 2020
  • In this study, the dynamic response characteristics of the embankment model were analyzed using shaking table experiments. Laminar shear box was used to minimize the boundary effect of the model. The ratio of the vertical length to horizontal length of the slopes were 1:1, 1:1.5, and 1:2. The sensor array which is consist of 12 accelerometers was used to measure acceleration time-histories at each location of the slope model. The dynamic response characteristics of the models were analyzed for sine wave, sinesweep wave, and artificial earthquake wave in this study. The experimental results show that the dynamic response of the embankment model is increased with the slope angle. Furthermore, the experimental setup used in this study was verified with the comparative analysis between experimental results and 1-D analytical simulation on the flat ground model.

Shaking Table Test of Isolated EDG Model (면진된 모형 비상디젤발전기의 지진응답 실험)

  • Kim, Min-Kyu;Choun, Young-Sun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.3 s.55
    • /
    • pp.33-42
    • /
    • 2007
  • In this study, for research on an improvement of the seismic safety of an EDG system, a small scale EDG system was manufactured. For the isolation system, the Coil Spring-Viscous Damper systems were selected. For the shaking table test, 3 kinds of seismic motions were selected which had different frequency contents. In this study, the isolation effects were different and they depended on the input seismic motion. In the case of an NRC earthquake which had low fiequency contents, the isolation effects of the horizontal direction were 20%. But for the seismic motions which had high fiequency contents, the isolation effects were $50{\sim}70%$. In the case of the vertical direction, poor isolation effects were observed. It was because the design properties and the real properties of the isolation system were a little different.

Numerical Study of Hybrid Base-isolator with Magnetorheological Damper and Friction Pendulum System (MR 감쇠기와 FPS를 이용한 하이브리드 면진장치의 수치해석적 연구)

  • Kim, Hyun-Su;Roschke, P.N.
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.2 s.42
    • /
    • pp.7-15
    • /
    • 2005
  • Numerical analysis model is proposed to predict the dynamic behavior of a single-degree-of-freedom structure that is equipped with hybrid base isolation system. Hybrid base isolation system is composed of friction pendulum systems (FPS) and a magnetorheological (MR) damper. A neuro-fuzzy model is used to represent dynamic behavior of the MR damper. Fuzzy model of the MR damper is trained by ANFIS (Adaptive Neuro-Fuzzy Inference System) using various displacement, velocity, and voltage combinations that are obtained from a series of performance tests. Modelling of the FPS is carried out with a nonlinear analytical equation that is derived in this study and neuro-fuzzy training. Fuzzy logic controller is employed to control the command voltage that is sent to MR damper. The dynamic responses of experimental structure subjected to various earthquake excitations are compared with numerically simulated results using neuro-fuzzy modeling method. Numerical simulation using neuro-fuzzy models of the MR damper and FPS predict response of the hybrid base isolation system very well.

Experimental Investigation on Behavior of Single Horizontal Buoyant Jet (단일수평부력제트의 거동에 관한 실험적 연구)

  • Seo, Il-Won;Kim, Ho-Jung;Kwon, Seok-Jae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.1011-1015
    • /
    • 2005
  • 본 실험에서는 부력 조건이 달라질 때 단공방류구에서 정체수역으로 수평방류되는 부력제트의 거동을 규명하였다. LIF (Laser Induced Fluorescence) 시스템을 이용하여 수행하였는데, LIF 시스템은 고해상도의 이미지를 취득할 수 있어 데이터의 정확도가 높으며, 동시에 한 평면상의 농도장을 일시에 측정할 수 있는 장점이 있는 기술이다. LIF 시스템은 크게 세부분으로 구성되어 있는데 방출시스템, 포착시스템, 처리시스템이 그것이다. 실험 조건을 고려해서 온수를 이용하여 주변수와의 밀도차를 재현하였으며, LIF 시스템의 추적입자로 형광염료 Rhodamine B를 사용하였다. 또한, 실험 데이터 취득과정에서 필요한 검정과정을 수행하였는데, LIF 시스템에서 검정과정은 레이저 입사광의 강도가 불균등한 분포를 가지는 점과 주변수의 매질에 의한 근의 감쇠가 발생하는 문제를 해결하기 위한 것이다. LIF 시스템은 부력제트의 농도장을 매우 정밀하게 측정할 수 있는데, 방류밀도 Froude 수가 변함에 따라 측정된 순간이미지를 통해 제트의 진화과정을 상세하고 가시적으로 확인할 수 있었다. 검정과정을 거친 농도 종단면에서 중심선의 연장선이 LIF 시스템에 의해 측정된 순간이미지의 중심선 궤적과 거의 일치하는 것도 알 수 있었다. 또한 LIF 시스템을 통해서 취득된 단일수평부력제트의 궤적과 중심선 희석률을 기존의 상용모형인 VISJET과 CORMIX1에 의해 예측된 결과와 비교$\cdot$분석한 결과, 제트 중심선 궤적의 경우, LIF 시스템을 이용한 측정값은 대체로 VISJET 모형의 결과와 일치하는 것으로 밝혀졌다. 중심선 희석률의 경우, LIF 측정값은 대체로 CORMIX1 모형, Cederwall(1968)의 경험식과 일치하는 경향을 보였다.0\%$일 때가 밸브를 $60\%$$80\%$ 개폐시켰을 때보다 $0.3kg/cm^2,\;0.29kg/cm^2$ 낮게 나타나 밸브를 전체 개방 했을 때 관로내의 수압이 상수설계기준에 적합한 수압을 유지함을 알 수 있다. 상수관로 설계 기준에서는 관로내 수압을 $1.5\~4.0kg/cm^2$으로 나타내고 있는데 $6kg/cm^2$보다 과수압을 나타내는 경우가 $100\%$로 밸브를 개방하였을 때보다 $60\%,\;80\%$ 개방하였을 때가 더 빈번히 발생하고 있으므로 대상지역의 밸브 개폐는 $100\%$ 개방하는 것이 선계기준에 적합한 것으로 나타났다. 밸브 개폐에 따른 수압 변화를 모의한 결과 밸브 개폐도를 적절히 유지하여 필요수량의 확보 및 누수방지대책에 활용할 수 있을 것으로 판단된다.8R(mm)(r^2=0.84)$로 지수적으로 증가하는 경향을 나타내었다. 유거수량은 토성별로 양토를 1.0으로 기준할 때 사양토가 0.86으로 가장 작았고, 식양토 1.09, 식토 1.15로 평가되어 침투수에 비해 토성별 차이가 크게 나타났다. 이는 토성이 세립질일 수록 유거수의 저항이 작기 때문으로 생각된다. 경사에 따라서는 경사도가 증가할수록 증가하였으며 $10\% 경사일 때를 기준으로 $Ro(mm)=Ro_{10}{\times}0.797{\times}e^{-0.021s(\%)}$로 나타났다.천성 승모판 폐쇄 부전등을 초래하는 심각한 선천성 심질환이다. 그러나 진단 즉시 직접 좌관상동맥-대동맥 이식술로 수술적 교정을 해줌으로써 좋은 성적을 기대할 수 있음을 보여주었다.특히

  • PDF

Assessment of Imaging Distortion in Magnetic Resonance Imaging for Stereotactic Radiosurgery: Through Phantom Study (뇌정위 방사선수술 시스템을 위한 자기공명영상의 공간적 왜곡의 측정 : 모형실험을 통한 연구)

  • 박선원;한문희;김동규;정현태;송인찬
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.1
    • /
    • pp.7-13
    • /
    • 2000
  • Purpose : To assess the distortion of MRI with the Leksell stereotactic radiosurgery system in variable pulse sequence and imaging plane through phantom study, to find most adequate imaging plane and pulse sequence for stereotactic radiosurgery system. Materials and methods : We made the phantoms for MRI and get images in variable conditions and analyzed the image distortion using image analysis program, and statistically using paired student t-test. Results : The transeverse plane images had acceptable error ranges bless than 1.5mm) in all pulse sequence in both the analysis of fiducial marker in stereotactic G-frame and the phantom study. The coronal plane images had unacceptable large errors (more than 1.7mm) in the analysis of fiducial marker in the stereotactic G-frame, but had corrected small errors (less than 1.5mm) in the phantom study. Conclusion : We find from the phantom study that the present MR machines are adequate for stereotactic surgery system in frequently used pulse sequences, and imaging planes.

  • PDF