• Title/Summary/Keyword: 모터구동밸브

Search Result 68, Processing Time 0.022 seconds

System Design and Fundamental Experiment for Thrust Control of $GO_2$/PE Hybrid Rocket ($GO_2$/PE 하이브리드 로켓의 추력제어를 위한 시스템 설계 및 기초실험)

  • Lee, Yong-Wu;Kang, Wan-Kyu;Huh, Hwan-Il
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.14 no.1
    • /
    • pp.40-47
    • /
    • 2010
  • In this study, basic research on the thrust control by controling oxidizer mass flow rate of a $GO_2$/PE hybrid rocket is presented. For this purpose, hybrid rocket system including oxidizer flow control system and data acquisition system was developed. To control oxidizer mass flow rate, we used needle valve with stepping motor which was controled by LabVIEW program. During the fundamental experiments, this system managed to follow the pre-programmed (20 N - 10 N - 20 N - 0 N) thrust level.

A Development of Web-based Safety Evaluation System of Motor-Operated-Valve in Nuclear Power Plant (웹기반 원전 동력구동밸브 안정성 평가 시스템 개발)

  • Bae, J.H.;Lee, K.N.;Kim, W.M.;Park, S.K.;Lee, D.H.;Kim, J.C.;Hong, J.S.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.903-908
    • /
    • 2001
  • A web-based client/server program, MOVIDIK(Motor-Operated-Valve Integrated Database Information of KEPCO) has been developed to perform a design basis safety evaluation for a motor-operated-valve(MOV) in the nuclear power plant. The MOVIDIK consists of seven analysis modules and one administrative module. The analysis module calculates a differential pressure on the valve disk, thrust/torque acting at a valve stem, maximum allowable stress, thermal-overload-relay selection, voltage degradation, actuator output and margin. In addition, the administrative module manages user information, approval system and code information. MOVIDIK controls a huge amount of evaluation data and piles up the safety information of safety-related MOV. The MOVIDIK will improve the efficiency of safety evaluation work and standardize the analysis process for the MOV.

  • PDF

Evaluation of the Disk-to-Body Friction Load by the Side Flow in Motor-Operated Globe Valves (모터구동 글로브밸브의 Side Flow에 의한 디스크-몸체 마찰부하 평가)

  • Jeoung, Rae-Hyuck;Park, Sung-Keun;Lee, Do-Hwan;Song, Seok-Yoon;Kang, Shin-Cheul
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.549-554
    • /
    • 2003
  • EPRI PPM (Performance Prediction Methodology), a method used for the prediction of required thrust of valves, can not be applied to unbalanced-disk globe valves operated in the fluid when the fluid temperature is above $150^{\circ}F$ because the thrust increase caused by the friction between the valve disk and body is not considered in the PPM. In order to apply PPM to the valves, EPRI suggested new friction prediction method to be added in the code. This paper analyzes the applicability of the prediction method comparing the disk-to-body friction load predicted from the method with the measured friction load from the field tests. The maximum values from the prediction method and those obtained from the test were 268lbs and about 1500lbs, respectively. It is included that the prediction method should be improved for the realistic prediction of disk-to-body friction load.

  • PDF

Study on Improvement in Steering Performance of an Auto-Guided Tractor using a Laboratory-made HILS simulator (HILS 시뮬레이터를 이용한 자율주행 트랙터 조향시스템 개선 연구)

  • Lee, Chang-Joo;Han, Xiongzhe;Jeon, Chanwoo;Kim, Junghoon;Kim, Hakjin
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.19-19
    • /
    • 2017
  • 자율주행 트랙터를 위한 트랙터 조향제어는 일반적으로 전자모터를 이용한 EPS(Electric Power Steering) 시스템을 스티어링 휠에 연결하여 회전변위를 변경하고 그 결과 오비트롤(Orbitrol) 밸브의 토출유량을 바꾸고 호스로 연결된 조향실린더의 변위를 조절하여 최종적으로 전방 타이어의 방향각을 변경하면서 이루어진다. 이러한 조향방식은 시스템 구조상 조향실린더와 오비트롤 밸브가 상대적으로 멀리 떨어져 있으며, 밸브 특성상 약 ${\pm}5^{\circ}$의 오버랩이 포함되어 있다. 또한, EPS의 전자모터는 관성력, 마찰, 백래시 등의 영향을 가진다. 이와 같은 복합적인 영향은 조향 응답을 느리게 만들어 상대적으로 빠른 속도에서 주행에서 추종성능이 떨어지는 문제가 발생한다. 본 연구에서는 자율주행 트랙터의 조향성능 개선 연구의 일환으로 조향 HILS 시뮬레이터를 설계제작하여 조향 성능의 요인을 실험적으로 구명하고자 하였으며 이를 바탕으로 조향 시스템의 설계개선 방안을 수립하고자 하였다. 시뮬레이터는 동양물산 80 마력급 TX803 트랙터에 사용되는 오픈센터방식의 오비트롤 유압회로 시스템을 기어펌프가 장착된 AC모터로 구동되게 구성하였으며, 유량은 모터의 주파수를 조절 회전속도를 조절 변경하였다. 추가적으로 EPS와 오비트롤 조합의 조향성능을 비교 및 개선하기 위해 비례제어밸브(PVG 32, Danfoss)를 추가 장착하였다. 실제 트랙터 조향 시 나타나는 마찰저항을 모사하기 위해 부하 실린더를 구성하였으며, 조향 실린더의 부하의 크기는 부하 실린더를 폐회로를 구성하고 유량비례제어밸브를 이용한 유로의 개구량 조절을 통해 부하의 크기를 약 4000 N 까지 증가시킬 수 있도록 하였다. EPS와 비례제어밸브를 제어하기 위해 CANoe 8.0 소프트웨어를 이용하여 CAN통신 기반 가상 조향ECU를 구성하였으며 오비트롤의 기본 성능을 확인하기 위해 조향휠에 따른 실린더 동특성 및 계단 추종성능을 비례제어밸브와 비교하였다. 오비트롤 밸브는 약 ${\pm}5^{\circ}$이상 동작 시 실린더 압력이 상승하기 시작하였으며, 이후 약 ${\pm}10^{\circ}$이상 동작 시 조향실린더가 동작하기 시작하였다. 계단 추종성능실험에서는 비례제어밸브가 약 2배 이상의 응답개선을 나타냈다. 자율주행 경로추종 성능을 향상시키기 위해서는 순간적인 출력밀도가 높은 비례제어밸브를 통해 응답개선이 필요한 것으로 나타났다.

  • PDF

Modelling and Characteristic Analysis of a Servo Valve using Linear Force Motor (리니어 포스모터를 사용한 서보밸브의 모델링 및 특성해석)

  • Huh, J.Y.;Kim, C.J.;Park, C.S.
    • 유공압시스템학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.1-6
    • /
    • 2010
  • Direct Drive Valves (DDV) with electric closed loop spool position control are suitable for electrohydraulic position, velocity, pressure or force control systems including those with high dynamic response requirements. The spool drive device is a permanent magnet linear force motor which can actively stroke the spool from its spring centered position in both directions. This basic study is carried out to drive the design parameters for developing a domestic DDV. The static and dynamic characteristics of DDV are examined. The simulation results are compared with data of manufacture's catalog to show the validity of the modelling.

  • PDF

Performance Analysis of an Electro-Hydrostatic Actuator (Electro-Hydrostatic Actuator의 성능해석)

  • Kim, Do-Hyun;Kim, Doo-Man;Hong, Yeh-Sun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.35 no.4
    • /
    • pp.316-322
    • /
    • 2007
  • The EHA(Electro-hydrostatic Actuator) reveals completely different characteristics from the conventional valve-controlled Electro-hydraulic actuators. In this paper, its mathematical model including nonlinear elements was derived to be verified by experiments. Based on this, a simulation program was developed for the EHAs consisting of an electric motor driven hydraulic pump, pipe lines and a cylinder. The influence of important design parameters such as peak motor torque and rotational inertia moment of the hydraulic pump on control performance was investigated, where the test condition was intentionally selected so that the motor torque was saturated during the transient phase. As a result, design requirements for improving the control accuracy under full speed operation conditions of the EHAs were investigated.

A STUDY OF VALVE DESIGN PROCEDURE IN HERMETIC COMPREESOR (왕복동식 압축기 밸브의 설계)

  • 조성욱;박성근;김형석;임종윤
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1992.10a
    • /
    • pp.98-103
    • /
    • 1992
  • 전세계적인 에너지 절약과 환경보존에 대한 관심과 요구가 증가함에 따라 소비전력규제와 CFC삭감에 대응한 국제경쟁력 확보가 중요한 과제로 대두 되고 있다. 이러한 상황변화에 따라 냉동 공조기기의 심장부인 압축기에 대 해서도 고효율 및 저소음화의 요구가 한층 높아졌다. 따라서 가혹한 환경에 도 견딜 수 있는 압축기의 개발은 필수적이라 할 수 있다. 소형밀폐형 압축 기는 크게 두 부분으로 나뉘어진다. 그 하나는 모터에 의한 회전구동부이고, 다른 하나는 실린더와 피스톤 그리고 밸브로 구성된 압축기구부이다. 그 중 에서 밸브는 진동 및 소음에 영향을 미치는 기본요소가 된다. 압축기의 밸브 는 근본적으로 밸브포트와 실린더 형상에 의해 결정되며, 이런 형상조건하에 서 밸브는 연속적인 운전이 되어야 하므로, 그 응답성이 좋아야 하고 무엇보 다도 자체의 신뢰성도 확보되어야 한다. 따라서 밸브의 동적특성과 응력 분 포를 정확히 예측하는 것이 중요한 과제가 된다. 본 논문에서는 컴퓨터를 이 용한 밸브의 동적특성과 응력해석을 위해 밸브의 형상을 유한요소 패키지인 ANSYS를 이용하여 해석하고, 그 모델링 및 해석이 타당성을 검토하기 위하 여 동적 특성해석은 홀로그래피(Holography) 기술을 이용하여 실험하고, 응 력해석은 스트레인 게이지(strain gage)를 이용하여 결과를 얻어서 서로 비 교하여 보았다.

  • PDF

Shape Design Sensitivity Analysis Case of the Valves installed in the Hydraulic Driving Motor (사판식 구동모터에 장착된 밸브의 설계변수 민감도 해석 사례)

  • Noh, Dae-Kyung;Jang, Joo-Sup
    • Journal of the Korea Society for Simulation
    • /
    • v.22 no.3
    • /
    • pp.81-87
    • /
    • 2013
  • This paper is about study how to decrese surge pressure that is occurred in excavator driving motor. We used computer simulation program SimulationX. It is also about the way finding design problem and approaching a solution through interpreting shape design sensitivity analysis. Programmes are below. First of all, finding shape fault by analyzing dynamic behavior of valves installed in hydraulic driving motor which is designed now. And drawing variable which is considered sensitive to improve dynamic efficiency among a lot of shape variables. Then, targeting that variable and examining dynamic efficiency stabilization tendency with controlling it. Finally, suggesting the most effective tuning method through variable combination as there are a lot of sensitive variables.

A Mathematical Model of Liquid Rocket Engine Using Simulink (Simulink를 이용한 액체로켓 엔진의 수학적 모델링)

  • Park, Soon-Young;Cho, Won-Kook;Seol, Woo-Seok
    • Aerospace Engineering and Technology
    • /
    • v.8 no.1
    • /
    • pp.82-97
    • /
    • 2009
  • In this study, a linearlized model of liquid rocket engine specifically for the gasgenerator cycle one was developed to serve as a basic control model. A commercial software Simulink was used for the modeling. Using this tool we studied the throttling characteristic of engine around its nominal mode. To obtain the effect of the throttle valve design on the engine's control characteristic, we included mathematical model of the control valve with driving motor and the pressure stabilizer which installed on the gas-generator fed line to sustain the mixture ratio of the gas-generator.

  • PDF

Flow Rate Control System Design for the Industrial Valve (산업용 밸브의 유량제어 시스템 설계)

  • Choi, Jeongju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.387-392
    • /
    • 2020
  • This paper proposes a flow-rate control system for industrial valves. Industrial valves are used in piping systems to control the flow rate and pressure. In general, valves used in pipelines are classified into globe valves, butterfly valves, and ball valves according to the shape. Motor, hydraulic, and pneumatic systems are used for operating valves. The flow meter should measure the flow rate when configuring the flow-rate control system. On the other hand, because the flow rate of the valve can be expressed by flow coefficient, a control scheme is proposed using the pressure deviation, which measures at the front and rear of the valve. The transfer function for the valve, according to the control input, was estimated using the signal compression method. Based on the induced transfer function, the disturbance observer was designed to improve the command following the performance of the valve stem. The performance of the proposed control method is compared with the flow-rate control result using the flow meter used.