• Title/Summary/Keyword: 모세관 팽창장치

Search Result 12, Processing Time 0.029 seconds

Prediction of Adiabatic Capillary Tube Length of Heat Pump Using Carbon Dioxide (CO2 히트펌프용 단열 모세관 길이 예측에 관한 연구)

  • Oh, Hoo-Kyu;Choi, Kwang-Hwan;Jeon, Min-Ju;Son, Chang-Hyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.5
    • /
    • pp.576-581
    • /
    • 2011
  • In this paper, the prediction of adiabatic capillary tube of heat pump using carbon dioxide is investigated theoretically and experimentally to offer the basic design data for the operating parameters of this system. The operating parameters considered in this study include evaporation temperature, cooling pressure of gas cooler, mass flowrate, and the length and diameter of capillary tube. Based on study results of several researchers, the correlation predicting the length of capillary tube of $CO_2$ heat pump was proposed. And the experimental results of evaporation temperature, mass flowrate and cooling pressure in adiabatic capillary tube have an good agreement to those calculated from Eq. (3) within 0.63~10.9%. Therefore, the prediction calculating the length of adiabatic capillary tube of $CO_2$ heat pump was proposed at the given conditions such as cooling pressure, evaporation temperature and capillary tube diameter.

Design of Capillary Tube for a Refrigeration Systems (냉동시스템의 모세관 설계)

  • 정백영;함성훈;김태진
    • Journal of the KSME
    • /
    • v.33 no.11
    • /
    • pp.966-972
    • /
    • 1993
  • 모세관(capillary tube)은 일정면적식 팽창기구의 대표적인 것으로서 사용역사가 길고, 신뢰성이 높고, 가격이 저럼하므로 냉동공조시스템의 냉매제어장치로 매우 많이 사용되고 있다. 이것은 냉동시스템의 응축기와 증발기 사이에서 유입하는 고압의 액상냉매를 증발기에서 증발하기 쉬운 증발압력까지 압력을 강하시키는 감압팽창작용과 증발기의 증발 용량에 적당한 냉매 질량유량을 공급하는 역할 (이 작용은 냉동시스템의 용량과 작동범위를 결정하는데 매우 중요하다.)을 한다. 이 글에서는 모세관의 형상, 재질 및 그장 . 단점과 작동원리, 내부 유동현상 등 일반적인 사항에 관하여 기술한다.

  • PDF

Comparison of refrigerant flow through capillary with short tube orifice (모세관과 오리피스 팽창장치의 냉매유량 조절특성의 비교)

  • 김용찬;최종민
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.1
    • /
    • pp.118-128
    • /
    • 1998
  • Capillary and short tube orifice have been widely used as an expansion device in refrigeration and air-conditioning system. To improve the system performance, expansion devices need to be optimized with the components of a refrigeration system. In the present study, a numerical model for a capillary, which can predict properties along a tube and flow rate through a tube, was developed by assuming homogeneous two-phase flow, A semi-empirical flow model that can be used to evaluate the flow rate through a short tube orifice was also developed by summarizing the experimental data. Finally, the results of the numerical model for capillaries were compared with those of the semi-empirical model for short tube orifices to verify dominant flow factors for the expansion devices.

  • PDF

The Effects of the Refrigerant Charge on the Performance of an Air Conditioner with Capillary Tube Expansions (냉매충전량이 모세관 팽창장치를 가진 공기조화기의 성능에 미치는 영향)

  • 최은수;김종배
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.5
    • /
    • pp.359-364
    • /
    • 2002
  • A popular type of residential air conditioner is the split system which has two separate units: indoor and outdoor units During field installation of the split system, the potential exists for not setting the charge exactly to the manufacturer´s specifications. The objective of this study is to investigate the effects of the refrigerant charge on the performance of the air conditioner. An air conditioner with capillary tube expansions was tested for various refrigerant charges. The results indicated that the more charge resulted in the more flowrate of the refrigerant. The flowrate of the refrigerant was one of the most important factors to understand the e(sects of the charge on the performance of the air conditioner with capillary tube expansions. Under-charge results in wide region of superheated vapor of the refrigerant in the evaporator, while over-charge results in high temperature of the liquid refrigerant in the evaporator.

Prediction of adiabatic capillary tube length of a vehicle heat pump using carbon dioxide (수송기계 $CO_2$ 히트펌프용 단열 모세관 길이 예측에 관한 연구)

  • Oh, Hoo-Kyu;Choi, Kwang-Hwan;Son, Chang-Hyo;Jeon, Min-Ju
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2011.06a
    • /
    • pp.277-277
    • /
    • 2011
  • 본 논문은 $CO_2$ 히트펌프용 모세관의 기초 설계자료를 제공하기 위해서 모세관 길이 예측에 대해서 이론 및 실험적으로 조사하였다. 본 연구에서 고려된 작동변수로는 증발온도, 가스냉각기 냉각압력, 냉매유량, 모세관의 관경 등이다. 몇몇연구자들의 자료를 바탕으로 $CO_2$ 모세관 길이를 예측할 수 있는 수학적 모델식을 작성하였다. 그리고 단열 모세관 팽창장치내 $CO_2$의 증발온도, 냉매유량, 냉각압력 등에 대해서 실험한 결과, Fig. 1에 나타낸 것처럼, 모세관 길이가 증가할수록 증발온도는 감소하는 것을 알 수 있다. 그리고 증발온도에 대한 실험값과 예측값의 비교 결과, 실험값이 예측값보다 약간 높게 나타났다. $CO_2$냉매가 모세관내를 통과할 때 플래쉬 가스(flash gas)의 발생으로 인해 액상의 양보다 기상의 양이 많아지고 액상의 압력강하보다 기상의 압력강하가 휠씬 더 크기 때문이다. 또한 증발온도에 대한 실험값과 예측값은 6.5~9.9% 이내에서 좋은 일치를 보였다. Fig. 2에 나타낸 것처럼, 모세관 길이가 증가할수록 냉매유량은 감소하는 것을 알 수 있다. 이는 전술한 바와 같이 모세관 길이가 증가할수록 냉매 압력강하가 더욱더 증가하기 때문이다. 그리고 냉매유량에 대한 실험값과 예측값의 비교 결과, 실험값이 예측값보다 약간 높게 나타났다. 이는 전술한 증발온도와 동일한 이유로 실제 $CO_2$냉매가 모세관내를 통과할 때 플래쉬 가스의 발생량이 많아지기 때문이다. 또한 냉매유량에 대한 실험값과 예측값은 0.64~10.9% 이내에서 좋은 일치를 보였다. Fig. 3에 나타낸 것처럼, 모세관 길이가 증가할수록 냉각압력은 증가하는 것을 알 수 있다. 이는 증발온도가 일정한 경우 모세관 길이가 증가할수록 냉매유량이 감소하여 압축기 토출측 온도(압력)가 상승하기 때문이다. 그리고 냉각압력에 대한 실험값과 예측값의 비교 결과, 실험값이 예측값보다 약간 낮게 나타났으며 실험값과 예측값은 1.04~3.7% 이내에서 좋은 일치를 보였다. 따라서 본 연구에서는 수송기계용 $CO_2$ 열펌프 단열 모세관에 대한 기초설계 자료로서, 냉각압력, 증발온도, 모세관 직경, 냉매유량 등의 조건으로부터 모세관 길이를 계산해낼 수 있는 예측 상관식을 제안하였다.

  • PDF

Development of simulation program for TXV and capillary tube performance analysis (감온 팽창밸브 및 모세관 성능 시뮬레이션 프로그램 개발)

  • 박봉수;한창섭
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.2
    • /
    • pp.170-180
    • /
    • 2000
  • The equation which is related to TXV performance was investigated. On the basis of this equation, the TXV simulation program was developed. Results of the developed TXV simulation program were proven by the experiment on the influence of pressure difference between TXV entrance and exit and equalizing pressure. Simulation results show very good agreement with experimental results, the RMS error between them was 1.83%. The capillary tube simulation program was made by the basic equation of fluid dynamics. Results of this program were proven by data which were experimented previously. The RMS error between simulation results and experimental results was 4.13% .

  • PDF

Performance of an inverter refrigeration system with a change of expansion devices (인버터형 냉동시스템의 팽창장치 변경에 따른 성능특성)

  • 이용택;김용찬;박윤철;김민수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.6
    • /
    • pp.928-936
    • /
    • 1999
  • An experimental study was performed to investigate characteristics of an inverter driven water-to-water refrigeration system with a variation of compressor frequencies and expansion devices. The frequency of a compressor varied from 30Hz to 75Hz, and performance of the systems applying three different expansion devices such as capillary tube, thermostatic expansion valve(TXV), and electronic expansion valve(EEV) were measured. The load conditions were altered by varying the temperature of the secondary fluid entering condenser and evaporator with a constant flow rate. When the test conditions were deviated from the standard value(rated value), TXV and EEV showed better performance than capillary tube due to optimum control of mass flow rate and superheat. In the present study, it was observed that the variable area expansion device had better performance than constant area expansion device in an inverter refrigeration system due to active control of flow area with a change of compressor frequency and load conditions.

  • PDF

Expansion Valves Characteristics for Development of Control System on Air Conditioning and Refrigeration Systems (공조.냉동장치의 제어시스템 개발을 위한 팽창밸브 특성)

  • Kim, J.D.;Jang, J.E.;Yoon, J.I.
    • Journal of Power System Engineering
    • /
    • v.2 no.3
    • /
    • pp.34-40
    • /
    • 1998
  • Performance characteristics of a refrigeration systems with various expansion valves and superheat changes were investigated experimentally. Experimental data have been taken utilizing three different devices; a thermostatic expansion valve, a linear type electronic expansion valve and a solenoid type electronic expansion valve. The data taken from tile three types of expansion valves were discussed with the temperature distribution of each zone in the evaporator and the superheat changes of the evaporator outlet In each zone temperature distribution fluctuated larger with the thermostatic expansion valve than with the electronic expansion valves. The optimum superheat ranged from $5^{\circ}C\;to\;15^{\circ}C$, and the superheat with the thermostatic expansion valve showed hunting phenomenon, which affected the evaporating and condensing temperature.

  • PDF

An Empirical Correlation of Refrigerant Flow Rate Through Coiled Capillary Tubes (코일 형상을 고려한 모세관 냉매유량 예측 상관식)

  • Park, Cha-Sik;Jang, Yong-Hee;Lee, Young-Soo;Kim, Yong-Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.1 s.256
    • /
    • pp.91-98
    • /
    • 2007
  • Air-conditioners use a spirally coiled capillary tube as an expansion device to enhance compactness of the unit. However, most empirical correlations in open literature were developed for straight capillary tubes without considering coiled effects on the mass flow rate. The objectives of this study are to investigate the flow characteristics of coiled capillary tubes and to develop a generalized correlation for mass flow rate through coiled capillary tubes. The mass flow rates through the coiled capillary tubes and straight capillary tubes were measured by varying operating conditions and tube geometry. The condensing temperatures varied at 40.5, 47.5 and $54.5^{\circ}C$, and subcoolings altered at 3.5, 6.5 and $11.5^{\circ}C$. The mass flow rates of the coiled capillary tubes decreased by 5 to 16% compared with those of the straight capillary tubes at the same operating conditions. An empirical correlation was developed by introducing equivalent length of capillary tube with non-dimensional parameters for coiled shape. The present correlation predicts the data with average and standard deviations of 0.33% and 3.24%, respectively.

Simulation of the flow characteristics of R1234yf flowing through capillary tubes (냉매 R1234yf의 모세관내 유동 특성에 관한 해석적 연구)

  • Kim, Daeyeong;Park, Chasik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.11
    • /
    • pp.6452-6457
    • /
    • 2014
  • R1234yf has been developed as an alternative refrigerant to R134a, which has been associated with global warming. The capillary tubes as expansion valves control the mass flow rate and balance system pressure in the refrigeration cycle. The present numerical model used the governing equations including the law of conservation of mass, momentum, and energy in a capillary tube. The mass flow rate of R1234yf decreased by 47.0% as the capillary tube length was increased from 1 to 4 m. As the inner diameter of the capillary tubes was changed from 1.3 to 1.7 mm, the mass flow rate of R134a and R1234yf increased by 117.9% and 121.0%, respectively. The mass flow rate of the R134a and R1234yf increased by 28.3% and 29.1% with subcooling increasing from 0 to $7^{\circ}C$. In addition, when the inlet temperature of the capillary tubes was changed from 35 to $60^{\circ}C$, the mass flow rate of R134a and R1234yf increased by 31.0% and 45.4%, respectively.