• Title/Summary/Keyword: 모듈형 스마트 의류 시스템

Search Result 2, Processing Time 0.016 seconds

Development of a Modular Clothing System for User-Centered Heart Rate Monitoring based on NFC (NFC 기반 사용자 중심의 모듈형 심박측정 의류 시스템 개발)

  • Cho, Hakyung;Cho, SangWoo;Cho, Kwang Nyun
    • Science of Emotion and Sensibility
    • /
    • v.23 no.2
    • /
    • pp.51-60
    • /
    • 2020
  • This study aimed to develop a modular smart clothing system for heart rate monitoring that reduces the inconvenience caused by battery charging and the large size of measurement devices. The heart rate monitoring system was modularized into a temporary device and a continuous device to enable heart rate monitoring depending on the requirement. The temporary device with near-field communication (NFC) and heart rate sensors was developed as a clothing attachment type that enables heart rate monitoring via smart phone tagging when required. The continuous device is based on Bluetooth Low Energy (BLE) communication and batteries and was developed to enable continuous heart rate measurement via a direct connection to the temporary device. Furthermore, the temporary device was configured to connect with a textile electrode made of a silver-based knitted fabric designed to be located below the pectoralis major muscle for heart rate measurement. Considering the user-experience factors, key functions, and the ease of use, we developed an application to automatically log through smart phone tagging to improve usability. To evaluate the accuracy of the heart rate measurement, we recorded the heart rate of 10 healthy male subjects with a modular smart clothing system and compared the results with the heart rate values measured by the Polar RS800. Consequently, the average heart rate value measured by the temporary system was 85.37, while that measured by the reference device was 87.03, corresponding to an accuracy of 96.73%. No significant difference was found in comparison with the reference device (T value = -1.892, p = .091). Similarly, the average heart rate measured by the continuous system was 86.00, while that measured by the reference device was 86.97, corresponding to an accuracy of 97.16%. No significant difference was found in terms of the heart rate value between the two signals (T value = 1.089, p = .304). The significance of this study is to develop and validate a modular clothing system that can measure heart rates according to the purpose of the user. The developed modular smart clothing system for heart rate monitoring enables dual product planning by reducing the price increase due to unnecessary functions.

A Design of Jacquard Woven Textile Electrode to Monitor the Electrical Activity of the Heart for Smart Clothing (스마트 의류의 전기적인 심장 활동을 모니터링 할 수 있는 자카드 텍스타일 전극 디자인)

  • Song, Ha-Young;Lee, Joo-Hyeon
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.12 no.2
    • /
    • pp.119-129
    • /
    • 2010
  • 오늘날 인간의 수명이 연장되고, 웰빙과 건강에 대한 관심이 증가됨에 따라서 언제 어디서나 건강을 모니터링 할 수 있는 건강 스마트 의류 시스템이 개발되고 있다. 이를 위하여 최근에는 생체신호의 모니터링이 가능하도록 디자인된 의류에 통합된 형태의 직물 전극이 개발되고 있다. 혁신적으로 의류 시스템에 통합되어 착용 가능한 니트, 우븐, 자수방식의 텍스타일 전극에 대한 다양한 연구가 개발 제시되고 있으며, 이의 일부는 상용화되어 있다. 이에 본 연구는 경위사의 일정한 직조제어 자동화 시스템이 가능한 컴퓨터 자카드 직기의 캐드(CAD) 직조디자인 방식을 통하여 생체신호 센싱 기능이 향상된 새로운 텍스타일 전극디자인을 연구하고자 하였다. 이를 위하여 본 연구에서는 기존 생체신호 센싱 전극의 개발 및 연구 동향, 비직물/전극 타입에 대한 단점과 장점에 대한 비교 분석을 이론적으로 살펴보고, 자카드 직조 직물 기반으로 심전도 센싱용 텍스타일 전극을 디자인하여 실험 연구하였다. 자카드 직조 방식의 심전도 센싱용 직물 전극은 전극 인터페이스 디자인 방식, 이중직물형 직조 디자인 방식, 사가공 등의 요인들을 고려하여 개발하였다. 본 연구에서 도출된 최종 자카드 직조 직물 기반의 텍스타일 전극은 스마트 의류에 통합시킨 텍스타일 전극 모듈로서 적용되여 향후 상용화 방안을 모색할 수 있다.

  • PDF